Entergy Pre-Filed Hearing Exhibit ENT000382, Program Section No. SEP-IP3-IST-2, Rev. 0, Indian Point 3 Fourth Ten-Year Interval Inservice Testing Program Plan (June 2011)
ML12090A654
Person / Time
Site: Indian Point  
Issue date: 06/09/2011
From:
Entergy Nuclear Operations
To:
Office of Nuclear Reactor Regulation
SECY RAS
Shared Package
ML12090A648 List:
References
RAS 22150, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12090A654 (13)


Text

--::::=-Entergy ENT000382 Submitted: March 3D, 2012 SEP-IP3-IST -2 I Rev. 0 lnservice Testing Program Plan Fourth Interval Indian Point Unit 3 I Page 1 OF 194 PROGRAM SECTION No. SEP-IP3-IST-2 Revision No. 0 Page 1 of 194 INDIAN POINT 3 FOURTH TEN-YEAR INTERVAL INSERVICE TESTING PROGRAM PLAN ENTERGY NUCLEAR ENGINEERING PROGRAMS APPLICABLE SITES All Sites: D Specific Sites: ANO D GGNS D IPEG [gJ JAF D PLP D PNPS D RBS D VY D W3 D HQN D Safety Related:

Yes D

No Program Section Revision Summary Current Description of Change Revision 0

This Site Engineering Program (SEP) supercedes the previous 1ST Program Plan, SEP-IST-IP3-1 rev. 2.

Entergy SEP-IP3-IST -2 Rev. 0 Inservice Testing Program Plan Fourth Interval Indian Point Unit 3 Page 2 OF 194 REVIEW ANI) CONCURRENCE Section Nt", $I~f':W')-ISI~2 ReV!!HOU No<< """.""",."":',:,.""",.,.,_,,.

Dille _,. __

~_~_., ___

(Additional' Reviewed ny' lines m.ay be added as needed)

Reviewed By (or Nf/I.)

SEP-IP3-IST -2 Rev. 0 Entergy Inservice Testing Program Plan Fourth Interval Indian Point Unit 3 Page 5 OF 194

1.0 INTRODUCTION

This revision of the Indian Point Unit 3 (IP3) Inservice Testing Program Plan will be in effect for the applicable duration of the fourth 120-month (1 O-year) inspection interval (7/21/09-7120119), unless changed for other reasons. The Plan will be updated prior to the start of the fifth inspection interval in accordance with the requirements of 10 CFR 50.55a(g).

1.1 Purpose To provide requirements for the performance and administration of assessing the operational readiness of those ASME Class 1, 2, and 3 pumps and valves whose specific functions are required to:

  • To mitigate the consequences of an accident.

IP3 was designed and licensed to operate as a Hot Shutdown plant. For the purposes of the 1ST Program, Cold Shutdown is defined as the "safe" shutdown condition (Unit 3 UFSAR, Table 5.2-3).

The Inservice Inspection (lSI) Classification Boundaries are identical to the Quality Group Boundaries shown on the plant Piping and Instrument Diagrams (P&IDs) listed in. This Inservice Testing (1ST) Program was developed using the following documents:

Title 10, Code of Federal Regulations, Part 50, Paragraph 50.55a Standard Review Plan 3.9.6, "Inservice Testing of Pumps and Valves" Safety Analysis Report, Indian Point Plant Technical Specifications, Indian Point, Unit 3 Technical Requirements Manual; Past program correspondence; Operating Procedures (Normal, Emergency and Off-Normal);

Design Basis Documents.

NUREG-1482, Rev. 1 "Guidelines for Inservice Testing at Nuclear Power Plants"

SEP-IP3-IST -2 Rev. 0

~

I Inservice Testing Program Plan

-~=-Entergy Fourth Interval Indian Point Unit 3 I Page 6 OF 194 1.2 Scope All references to the ASME OM Code within this document are intended to apply to the 2001 OM Code through the 2003 Addenda. The program plan was prepared to meet the requirements of the following subsections of the American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants, 2001 Edition through 2003 Addenda as follows:

ASME OM Code, Subsection ISTA, "General Requirements" ISTA contains the requirements directly applicable to inservice testing including the Owner's Responsibility and Records Requirements.

ASME OM Code, Subsection ISTS, "In service Testing of Pumps in Light-Water Reactor Nuclear Power Plants" ISTS establishes the requirements for inservice testing of pumps in light-water reactor nuclear power plants. The pumps covered are those provided with an emergency power source, that are required in the shutting down the reactor to the safe shutdown condition, in maintaining the safe shutdown condition, and/or in mitigating of the consequences of an accident.

ASME OM Code, Subsection ISTC, "Inservice Testing of Valves in Light-Water Reactor Nuclear Power Plants" ISTC establishes the requirements for inservice testing of valves in light-water reactor nuclear power plants.

The valves covered include those which provide overpressure protection and those which are required to perform a specific function, either actively through the changing of valve obturator position or passively by maintaining required obturator position in shutting down a reactor to the safe shutdown condition, in maintaining the safe shutdown condition, or in mitigating the consequences of an accident.

ASME OM Code, Mandatory Appendix I, "In service Testing of Pressure Relief Devices in Light-Water Reactor Nuclear Power Plants" Appendix I provides the requirements for performance testing and monitoring of nuclear plant pressure relief devices. Methods, intervals, and record requirements for monitoring and testing are established, as well as guidelines for the evaluation of results.

The Appendix applies to safety valves, safety relief valves, pilot-operated pressure relief valves, power-actuated pressure valves, nonreclosing pressure relief devices and vacuum relief devices, including all accessories and appurtenances.

Inservice Testing Program Plan Fourth Interval SEP-IP3-IST -2 Indian Point Unit 3 Rev. 0 Page 7 OF 194 The IP3, Pump and Valve Inservice Testing Plan will be in effect through the fourth 120-month interval.

Unit Three:

Begin: July 21, 2009 End: July 20,2019

~-- Entergy SEP-IP3-IST -2 Inservice Testing Program Plan Fourth Interval Indian Point Unit 3 ATTACHMENT 12 INSERVICE TESTING PUMP TABLE Rev. 0

e SEP-IP3-IST -2 I Rev. 0

~- Entergy Inservice Testing Program Plan Fourth Interval Indian Point Unit 3 I Page 119 OF 194 Pump Table Pump Tag P&ID P&ID Cat Code Pump Pump Test Test

. Relief Tech Zone Class Type Driver Type Freq Request Position ACC-31 F-27513-1 G-5 B

3 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Aux Component Cooling Pump #31 ACC-32 F-27513-1 G-5 B

3 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Aux Component Cooling Pump #32 ACC-33 F-27513-1 G-6 B

3 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Aux Component Cooling Pump #33 ACC-34 F-27513-1 G-6 B

3 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Aux Component Cooling Pump #34 ACC-CW-31 F-2751 3-1 C-4 B

3 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y SI Pump Cire Water Pump #31

Inservice Testing Program Plan SEP-IP3-IST -2 Rev. 0 Fourth Interval Indian Point Unit 3 Page 120 OF 194 Pump Table Pump Tag P&ID P&ID Cat Code Pump Pump Test Test Relief Tech Zone Class Type Driver Type Freq Request Position ACC-CW-32 F-27513-1 8-4 8

3 Centrifugal Motor bdP M3 edP 2Y cO 2Y eV 2Y SI Pump Cire Water Pump #32 ACC-CW-33 F-27513-1 A-4 8

3 Centrifugal Motor bdP M3 edP 2Y cO 2Y eV 2Y SI Pump Cire Water Pump #33 AFW-31 F-20193 8-5 A

3 Centrifugal Motor adP M3 edP 2Y aO M3 cO 2Y aV M3 eV 2Y Motor Driven Aux Feed Pump #31 AFW-32 F-20193 A-5 A

3 Centrifugal Turbine adP M3 edP 2Y aO M3 cO 2Y aN M3 eN 2Y aV M3 cV Aux

e SEP-IP3-IST -2 I Rev. 0 Inservice Testing Program Plan

~ Entergy Fourth Interval Indian Point Unit 3 I Page 121 OF 194 Pump Table Pump Tag P&ID P&ID Cat Code Pump Pump Test Test Relief Tech Zone Class Type Driver Type Freq Request Position AFW-33 F-20193 8-6 A

3 Centrifugal Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Motor Driven Aux Feed Pump #33 CCW-31 F-27513-1 C-7 A

3 Centrifugal Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Component Cooling Pump #31 CCW-32 F-27513-1 8-7 A

3 Centrifugal Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Component Cooling Pump #32 CCW-33 F-27513-1 8-7 A

3 Centrifugal Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Component Cooling Pump #33

e SEP-IP3-IST -2 I Rev. 0 Inservice Testing Program Plan

~ ETZtergy Fourth Interval Indian Point Unit 3 I Page 122 OF 194 Pump Table Pump Tag P&ID P&ID Cat Code Pump Pump Test Test Relief Tech Zone Class Type Driver Type Freq Request Position CS-31 F-27503 0-4 8

2 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Containment Spray Pump #31 CS-32 F-27503 0-4 8

2 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Containment Spray Pump #32 REC-31 F-27353 8-5 8

2 Centrifugal Motor cdP 2Y Oc 2Y cV 2Y Recirculation Pump #31 REC-32 F-27353 8-4 B

2 Centrifugal Motor cdP 2Y cO 2Y cV 2Y Recirculation Pump #32 RHR-31 F-27513-1 F-3 A

2 Centrifugal Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y RHR Pump #31

SEP-IP3-IST-2 Rev. 0

-- Entergy Inservice Testing Program Plan Fourth Interval Indian Point Unit 3 Page 123 OF 194 Pump Table Pump Tag P&ID P&ID Cat Code Pump Pump Test Test Relief Tech Zone Class Type Driver Type Freq Request Position RHR-32 F-27513-1 G-3 A

2 Centrifugal Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y RHR Pump #32 SIS-31 F-27503 F-4 B

2 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Safety Injection Pump #31 SIS-32 F-27503 F-4 B

2 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Safety Injection Pump #32 SIS-33 F-27503 G-4 B

2 Centrifugal Motor bdP M3 cdP 2Y cO 2Y cV 2Y Safety Injection Pump #33 Vert Line SWN-31 F-20333 B-2 A

3 Shaft Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Service Water Pump #31

~

SEP-IP3-IST -2 I Rev. 0

[nservice Testing Program Plan

~ Entergy Fourth Interval Indian Point Unit 3 I Page 124 OF 194 Pump Table Pump Tag P&ID P&ID Cat Code Pump Pump Test Test Relief Tech Zone Class Type Driver Type Freq Request Position Vert Line SWN-32 F-20333 8-3 A

3 Shaft Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Service Water Pump #32 Vert Line SWN-33 F-20333 8-4 A

3 Shaft Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Service Water Pump #33 Vert Line SWN-34 F-20333 8-5 A

3 Shaft Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Service Water Pump #34 Vert Line SWN-35 F-20333 8-6 A

3 Shaft Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Service Water Pump #35

A SEP-IP3-IST-2 I Rev. 0 Inservice Testing Program Plan

-:::;=-. Entergy Fourth Interval Indian Point Unit 3 I Page 125 OF 194 Pump Table Pump Tag P&ID P&ID Cat Code Pump Pump Test Test Relief Tech Zone Class Type Driver Type Freq Request Position Vert Line SWN-36 F-20333 8-7 A

3 Shaft Motor adP M3 cdP 2Y aO M3 cO 2Y aV M3 cV 2Y Service Water Pump #36