ML20147D684: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot insert) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter:~ | {{#Wiki_filter:~ | ||
ATTACHMENT 2 Detroit Edison | ATTACHMENT 2 Detroit Edison Date: | ||
Date: | December 23, 1987 To: | ||
S. K. Sharma Fermi 2 From: | |||
R. L. Colvell d## | |||
P.M.Beckwith)44(i Engineering Research | P.M.Beckwith)44(i Engineering Research | ||
==Subject:== | ==Subject:== | ||
Chemical and Physical Testing of Fasteners for Fermi 2 Fermi Test Req. 610143 Engineering Research Report 87C71-21, Revision 2 Ten items were delivered to Engineering Research for material analysis. They are described as follows. | Chemical and Physical Testing of Fasteners for Fermi 2 Fermi Test Req. 610143 Engineering Research Report 87C71-21, Revision 2 Ten items were delivered to Engineering Research for material analysis. They are described as follows. | ||
Item i | Item i DENB i Description 1 | ||
8 1/2"Bolt A193 Gr. B8 | 1 3/8" 13/16" Bolt A193 Gr. B7 2 | ||
Test Piocedurca | 2 7/8" 5" Bolt A307 Gr. B 3 | ||
3 5/8" 2-15/16"Bolt A307 Gr. B 8 1/2"Bolt A193 Gr. B8 4 | |||
4 1" | |||
Analysis | 8 ;/2" Bolt A307 Gr. B 5 | ||
5 1" | |||
b 6 | |||
6 5/8" 3-1/4" Bolt SAE J429 Gr. 2 7 | |||
7 3/4" 4" Bolt SAE J429 Gr. 5 8 | |||
8 | |||
.1/2" 13 - 5" Bolt 9 | |||
9 3/8" 2" Bolt SAE J429 Gr. 2 10 10 5/16" 5/8" Bolt SAE J429 Gr. 5 The test results are displayed on attached NRC Data Summary Form alon.g with the apprepriate specifications for each item. | |||
Test Piocedurca 1. | |||
TP-FL-609 Rev. O Test Procedure for the Determination of Carbon in Steel. | |||
2. | |||
TP-FL-032 Rev. O Tast Procedure for Dissolution of Material by Acid Digestion for Total Metals Analysis I | |||
3. | |||
TP-FI,-045 Rev. O Test Procedure for Determination of Sulfur in Steel and Cast Iron. | |||
4. | |||
TP-FL-046 Rev. O Test Procedure for the Analysis of Steel and Cart iron Samples by Inductively Coupled Plasma Spectroscopy 5. | |||
TP-AM-003 Rev. 2 Test Procedure for Material Evaluation in f | |||
Accordance with ASTM, ANSI, ASIT AWS, and i | |||
SAE Test Methods. | |||
? | ? | ||
PE.14/22 8801200261 880114 PDR | PE.14/22 8801200261 880114 PDR ADCCK 05000341 PDR Q | ||
ATTACHMENT 2 87C71-21 Rev. 2 | ATTACHMENT 2 87C71-21 Rev. 2 2. | ||
Test Requisition #610143 DATA SL99fARY Mechanical Analysis | Test Requisition #610143 DATA SL99fARY Mechanical Analysis Chemical Analysis (wt. Z) | ||
Item i | Item i Crade Hardness C | ||
Mn P | |||
S Si Mo Cr Ni 1 | |||
A193 B7 0.390 0.86 | |||
5 | <0.020 0.018 0.30 0.15 0.87 0.14 Spec | ||
6 | (--) | ||
Spec | (.37.49) | ||
Hardness Core | (.65-1.10) (<0.035) | ||
(HRC) | (<0.040) | ||
* denotes deviation from specificatio.a. | (.15.35) | ||
(.15.25) | |||
8 | (.75-1.2) 4 A193 B8 77.6 HRB 0.063 1.23 | ||
<0.02 0.024 0.27 0.35 19.0 9.0 Spec | |||
10A | (<96 HRB) | ||
(<0.08) | |||
10B | (<2.0) | ||
(<0.045) (<0.03C) | |||
(<l.0) | |||
'(---) | |||
(18.0-20.0) | |||
(8.0-10,5) 2 A307 Gr. B | |||
*98.4 HRB | |||
<0.020 0.020 3 | |||
84.7 | |||
<0.020 0.030 | |||
~ | |||
5 80.6 | |||
<0.020 0.025 | |||
~ | |||
Spec (69-95 HRB) | |||
(---) | |||
( | |||
) | |||
(<0.040) (<0.050) | |||
(---) | |||
(---) | |||
( | |||
) | |||
(---) | |||
6 SAE J429 Gr.2 91.9 0.21 | |||
<0.020 0.034 9 | |||
SAE J429 Gr.2 *40.4 HF.C 0.37 | |||
<0.020 0.028 l | |||
Spec 80-100 HRB (<0.55) | |||
( | |||
) | |||
(<0.048) (<0.058) ( | |||
) | |||
( | |||
) | |||
( | |||
) | |||
(- -) | |||
Hardness Core Super. | |||
Chemical Analysis (wt.Z) | |||
(HRC) | |||
(30-N) | |||
C, P, | |||
S, 7 | |||
SAE J429 Gr.5 25.3 51 0.36 0.020 0.026 | |||
* denotes deviation from specificatio.a. | |||
~ | |||
8 29.1 53 0.35 | |||
<0.020 0.033 Higher hardness values indicate higher | |||
~ | |||
10A 29.9 51 0.40 | |||
<0.020 0.012 strength bolts. Although stronger, | |||
~ | |||
10B 29.9 51 0.40 | |||
<0.020 0.013 bolts with hardness values above 20 HRC | |||
~ | |||
Spec (25-34) | |||
(<54) | |||
(.28.55) | |||
(<0.048) (<0.058) are more suseptible to S.C.C.. | |||
. PE.14/22 | . PE.14/22 | ||
ATTACHMENT 2 j | |||
87C71-21 Rsv. 2 | 87C71-21 Rsv. 2 3. | ||
I MT&E Equipment. | I MT&E Equipment. | ||
ER0013 | ER0013 Wilson Rockwell Hardness Tester ER0014 Wilson Rockwell Hardness Tester ER7025 LECO Carbon Analyzer I | ||
ER7027 Sulfur Analysis System ER7000 Analytical' Balance ER0553 Balance Weights ER7002 Inductively Coupled Plasma Spectrometer All work was performed in accordance with the Engineering Research Quality Assurance Program. | |||
R. L. Gamble Copies to: | Approved by: | ||
hf 4fJ bM J.D.Cplewski J. C. CUillaumin Supervisor i | |||
QA Administrator:_ | |||
R. L. Gamble Copies to: | |||
R. L. McIntyre (File) | |||
Fermi 2 Dist. | Fermi 2 Dist. | ||
l l | l l | ||
| Line 68: | Line 147: | ||
4 l | 4 l | ||
RLC/gc PE.14/22 l | RLC/gc PE.14/22 l | ||
-}} | |||
Latest revision as of 13:15, 11 December 2024
| ML20147D684 | |
| Person / Time | |
|---|---|
| Site: | Fermi |
| Issue date: | 12/23/1987 |
| From: | Cyrulewski J, Gamble R, Guillaumin J DETROIT EDISON CO. |
| To: | |
| Shared Package | |
| ML20147D645 | List: |
| References | |
| 87C71-21, 87C71-21-R02, 87C71-21-R2, NUDOCS 8801200261 | |
| Download: ML20147D684 (3) | |
Text
~
ATTACHMENT 2 Detroit Edison Date:
December 23, 1987 To:
S. K. Sharma Fermi 2 From:
R. L. Colvell d##
P.M.Beckwith)44(i Engineering Research
Subject:
Chemical and Physical Testing of Fasteners for Fermi 2 Fermi Test Req. 610143 Engineering Research Report 87C71-21, Revision 2 Ten items were delivered to Engineering Research for material analysis. They are described as follows.
Item i DENB i Description 1
1 3/8" 13/16" Bolt A193 Gr. B7 2
2 7/8" 5" Bolt A307 Gr. B 3
3 5/8" 2-15/16"Bolt A307 Gr. B 8 1/2"Bolt A193 Gr. B8 4
4 1"
8 ;/2" Bolt A307 Gr. B 5
5 1"
b 6
6 5/8" 3-1/4" Bolt SAE J429 Gr. 2 7
7 3/4" 4" Bolt SAE J429 Gr. 5 8
8
.1/2" 13 - 5" Bolt 9
9 3/8" 2" Bolt SAE J429 Gr. 2 10 10 5/16" 5/8" Bolt SAE J429 Gr. 5 The test results are displayed on attached NRC Data Summary Form alon.g with the apprepriate specifications for each item.
Test Piocedurca 1.
TP-FL-609 Rev. O Test Procedure for the Determination of Carbon in Steel.
2.
TP-FL-032 Rev. O Tast Procedure for Dissolution of Material by Acid Digestion for Total Metals Analysis I
3.
TP-FI,-045 Rev. O Test Procedure for Determination of Sulfur in Steel and Cast Iron.
4.
TP-FL-046 Rev. O Test Procedure for the Analysis of Steel and Cart iron Samples by Inductively Coupled Plasma Spectroscopy 5.
TP-AM-003 Rev. 2 Test Procedure for Material Evaluation in f
Accordance with ASTM, ANSI, ASIT AWS, and i
SAE Test Methods.
?
PE.14/22 8801200261 880114 PDR ADCCK 05000341 PDR Q
ATTACHMENT 2 87C71-21 Rev. 2 2.
Test Requisition #610143 DATA SL99fARY Mechanical Analysis Chemical Analysis (wt. Z)
Item i Crade Hardness C
Mn P
S Si Mo Cr Ni 1
A193 B7 0.390 0.86
<0.020 0.018 0.30 0.15 0.87 0.14 Spec
(--)
(.37.49)
(.65-1.10) (<0.035)
(<0.040)
(.15.35)
(.15.25)
(.75-1.2) 4 A193 B8 77.6 HRB 0.063 1.23
<0.02 0.024 0.27 0.35 19.0 9.0 Spec
(<96 HRB)
(<0.08)
(<2.0)
(<0.045) (<0.03C)
(<l.0)
'(---)
(18.0-20.0)
(8.0-10,5) 2 A307 Gr. B
- 98.4 HRB
<0.020 0.020 3
84.7
<0.020 0.030
~
5 80.6
<0.020 0.025
~
Spec (69-95 HRB)
(---)
(
)
(<0.040) (<0.050)
(---)
(---)
(
)
(---)
6 SAE J429 Gr.2 91.9 0.21
<0.020 0.034 9
SAE J429 Gr.2 *40.4 HF.C 0.37
<0.020 0.028 l
Spec 80-100 HRB (<0.55)
(
)
(<0.048) (<0.058) (
)
(
)
(
)
(- -)
Hardness Core Super.
Chemical Analysis (wt.Z)
(HRC)
(30-N)
C, P,
S, 7
SAE J429 Gr.5 25.3 51 0.36 0.020 0.026
- denotes deviation from specificatio.a.
~
8 29.1 53 0.35
<0.020 0.033 Higher hardness values indicate higher
~
10A 29.9 51 0.40
<0.020 0.012 strength bolts. Although stronger,
~
10B 29.9 51 0.40
<0.020 0.013 bolts with hardness values above 20 HRC
~
Spec (25-34)
(<54)
(.28.55)
(<0.048) (<0.058) are more suseptible to S.C.C..
. PE.14/22
ATTACHMENT 2 j
87C71-21 Rsv. 2 3.
I MT&E Equipment.
ER0013 Wilson Rockwell Hardness Tester ER0014 Wilson Rockwell Hardness Tester ER7025 LECO Carbon Analyzer I
ER7027 Sulfur Analysis System ER7000 Analytical' Balance ER0553 Balance Weights ER7002 Inductively Coupled Plasma Spectrometer All work was performed in accordance with the Engineering Research Quality Assurance Program.
Approved by:
hf 4fJ bM J.D.Cplewski J. C. CUillaumin Supervisor i
QA Administrator:_
R. L. Gamble Copies to:
R. L. McIntyre (File)
Fermi 2 Dist.
l l
l i
4 l
RLC/gc PE.14/22 l
-