ATTACHMENT 2 Deholt Edison Date:

December 21, 1987 To:

S. K. Sharma Fermi 2 From:

R. L. Colwell

/f/"d' P.M.BeckwithfgQh U

Engineering Research

Subject:

Chemical and Physical Testing of Fasteners for Fermi 2 Fermi Test Req. 610145 Engineering Research Report 87C71-22. Revision 1 Ten items were delivered to Engineering Research for material analysis. They are described below.

Item i DENN i Description 1

2 5/16" - 14 Nut A563 Gr. A 2

3 5/8" - 10 Nut A563 Gr. A 3

4 7/16" - 13 Nut A563 Gr. A l

4 5

9/16" - 11 Nut A563 Gr. A 5

6 (Two) 3/8" - 16 Nuts A563 Gr. A 6

7 5/8" - 11 Nut A563 Gr. A 7

8 (Two) 3/8" - 16 Nuts A563 Gr. A 8

9 1/2" - 13 Nut A-194 Gr. 2H l

9 Nut A563 Gr. A 9

10 7/8" 10 11 7/8" - 11 Nut A563 Gr. A The testing results are displayed on attached NRC Data Summary Form along with the appropriate specifications for each item.

Test Procedures 1.

TP-FL-009 Rev. O Test Procedure for the Determination of Carbon in Steel.

2.

TP-FL-032 Rev. O Test Procedure for Dissolution of Material by Acid Digestion for Total Metals Analysis 3.

TP-FL-045 Rev. O Test Procedure for Determination of Sulfur in Steel and Cast iron.

4.

TP-FL-046 Rev. O Test Procedure for the Analysis of Steel and Cast Iron Samples by Inductively Coupled Plasma Spectroscopy 5.

TP-AM-003 Rev. 2 Test Procedure for Material Evaluation in Accordance with ASTM, ANS1, ASKE, AWS, and SAE Test Methods.

PE.14/20 88o1200266 880114 PDR ADOCK 05000341

}

G PDR

ATTACHMENT 2 87C71-22 Rev. l.

2.

DATA

SUMMARY

Mechanical Analysis Chemical Analysis (Wt. I)

Ites #

Crade Bardness Engi 0.2% Y.S.

j{

P, '

ji, 1

A563 Gr. A 90.7 (HRB)

N/A N/A

.058

<.02 0.0146 2

82.0 N/A N/A

.340 0.02 0.0152 3

93.0 N/A N/A

.062

<0.02 0.0136 4

81.4 N/A N/ A

.221

<0.02 0.0328 5A 94.1 N/A N/A

.080

<0.02 0.0155 SB 95.1 N/A N/A

.068

<0.02 0.0156 6

96.6 N/A N/A

.055

<0.02 0.0252 7A 90.5 N/A N/A

.020

<0.02 0.0183 7B 98.5 N/A N/A

.142

<0.02 0.0129 9

77.8 N/A N/A

.197

<0.02 0.0223 10 77.5 N/A N/A

.205

<0.02 0.022 Spec (B68-C32)

N/A N/A

(.55 max)

(.12 max) (.15 max) 6 A194 Gr. 2H 29.8 (HRC)

N/A N/A

.479

.023

.016 Spec (24-38 HRC) N/A N/A

(.400 min) (.04 max) (.050 max)

Corresponding Specifications in brackets (

).

PE.14/20 1

l

ATTACHMENT 2 87C71-22 R9v. I 3.

Iff6E Equipment ER0013 Wilson Rockwell Hardness Tester ER7025 LECO Carbon Analyzer ER7027 Sulfur Analysis System ER7000 Analytica,1 Balance ER0553 Balance Weights ER7002 Inductively Coupled Plasma Spectrometer All work was performed in accordance with the Engineering Research Quality Assurance Program.

\\

v Approved by:_ 4 01a1 n

[3. D. fyrulewski J. C. GtT11Taumin

(

Supfrvisor i-QA Administrator:

R. L. Gamble Copies to:

R. L. McIntyre (File)

Fermi 2 Dist.

s i

f

[

RLC/ge

[

i PE.14/20 1

_.,