05000334/FIN-2009005-01: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 1: Line 1:
{{finding
{{finding
| title = Failure to Properly Verify Valve Line-up Results in an Overpressurization of the Isolated CIS" Reactor Coolant Loop.
| title = Failure to Properly Verify Valve Line-up Results in an Overpressurization of the Isolated CIS\" Reactor Coolant Loop.


| docket = 05000334, 05000413
| docket = 05000334, 05000413
Line 13: Line 13:
| identified by = Self-Revealing
| identified by = Self-Revealing
| Inspection procedure = IP 71153
| Inspection procedure = IP 71153
| Inspector = J D,'Antonio J, Tomlinson P, Kaufman R, Bellamy T, Moslak T, O'Hara D, Spindler D, Werkheiser E, Burke
| Inspector = J D, 'Antonioj Tomlinson, P Kaufman, R Bellamy, T Moslak, T O, 'Harad Spindler, D Werkheiser, E Burket
| CCA = H.8
| CCA = H.8
| INPO aspect = WP.4
| INPO aspect = WP.4

Revision as of 20:38, 20 February 2018

01
Site: Beaver Valley
Report IR 05000334/2009005 Section 4OA3
Date counted Dec 31, 2009 (2009Q4)
Type: NCV: Green
cornerstone Initiating Events
Identified by: Self-revealing
Inspection Procedure: IP 71153
Inspectors (proximate) J D
'Antonioj Tomlinson
P Kaufman
R Bellamy
T Moslak
T O
'Harad Spindler
D Werkheiser
E Burket
CCA H.8, Procedure Adherence
INPO aspect WP.4
'