{{#Wiki_filter:FACILITY COMMENTS TO THE NRC-PROPOSED PALISADES INITIAL WRITTEN EXAMINATION MAY 2005 THE FACILITY DID NOT PROVIDE ANY WRITTEN COMMENTS TO THE NRC-PROPOSED OPERATING TEST.
{{#Wiki_filter:FACILITY COMMENTS TO THE NRC-PROPOSED PALISADES INITIAL WRITTEN EXAMINATION - MAY 2005 THE FACILITY DID NOT PROVIDE ANY WRITTEN COMMENTS TO THE NRC-PROPOSED OPERATING TEST.  


PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS
PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS  
                ~~
~~
Comment                               Resolution
Comment
: 1) Revise question stem for clarity by stating PT-01028     Comments incorporated.
: 1) Revise question stem for clarity by stating PT-01028 fails low and no operator action is taken, as opposed to knowing that the channel was placed in trip after 8 days of being inoperable.
fails low and no operator action is taken, as opposed to knowing that the channel was placed in trip after 8 days of being inoperable.
: 2) Also, in distractors A and B revise NI RPS function to affected RPS trip function.
: 2) Also, in distractors A and B revise NI RPS function to affected RPS trip function.
Remove Quench tank temp is 106F and increasing very       Comment incorporated.
Remove Quench tank temp is 106F and increasing very slowly from the question stem.
slowly from the question stem.
Tech incorrect. As Pzr level rises, charging flow lowers and letdown flow will rise.
Tech incorrect. As Pzr level rises, charging flow lowers   Comment incorporated.
Distractor D was also a correct answer per EOP-4.0.
and letdown flow will rise.
Question resived.
Distractor D was also a correct answer per EOP-4.0.     Comment incorporated Question resived.
RVLMS design cannot indicate in given increments, stem should indicate RVLMS reading of 71 Remove Turbine Building temperature and pressure are increasing from the question stem, since it adds no value.
RVLMS design cannot indicate in given increments,         Comment incorporated stem should indicate RVLMS reading of 71 Remove Turbine Building temperature and pressure         Comment incorporated, are increasing from the question stem, since it adds no value.
: 1) In the question stem, change Main Control Board indication(s) to indication(s).
: 1) In the question stem, change Main Control Board       Comments incorporated.
indication(s) to indication(s).
: 2) Change distractor C to: ONLY Amperage indications for Battery No. 1 can be used.
: 2) Change distractor C to: ONLY Amperage indications for Battery No. 1 can be used.
Power level was included to clarifv mode of applicability. Comment incorporated.
Power level was included to clarifv mode of applicability.
Conflicting references between DBD 5.02, 3.3.2 and         Comment incorporated.
Conflicting references between DBD 5.02, 3.3.2 and ONP-2.3. Sys. Eng. was contacted regarding question and auestion was revised.
ONP-2.3. Sys. Eng. was contacted regarding question and auestion was revised.
Revise question to state that the CC system is unavailable as opposed to stating a total loss of CCW has occurred.
Revise question to state that the CC system is             Comment incorporated unavailable as opposed to stating a total loss of CCW has occurred.
A plant modification has changed the way the Instrument Air System is operated. Alter question to reflect current way plant operates (1 SAC running as opposed to 2 SACS running).
A plant modification has changed the way the               Comment incorporated.
Resolution Comments incorporated.
Instrument Air System is operated. Alter question to reflect current way plant operates (1 SAC running as opposed to 2 SACS running).
Comment incorporated.
Page 1 of 6
Comment incorporated.
Comment incorporated Comment incorporated Comment incorporated, Comments incorporated.
Comment incorporated.
Comment incorporated.
Comment incorporated Comment incorporated.
Page 1 of 6  


PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRllTEN EXAM COMMENTS Comment                                     Resolution Revise from asking what makes a control rod operable         Zomment incorporated.
PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRllTEN EXAM COMMENTS Comment Revise from asking what makes a control rod operable to asking if given conditions make the rod inoperable.
to asking if given conditions make the rod inoperable.
In distractors A and B, change 525°F to 524°F to agree with EOPs.
In distractors A and B, change 525°F to 524°F to           Zomment incorporated.
The condenser becomes unavailable for turbine bypass valve operation at 5 Hg condenser vacuum, thus the condenser will be available for use for the given plant conditions. The correct answer is thus B and not D.
agree with EOPs.
Question revised by changing distractor C & D to 1.I times for alarm setpoint Alarm part of question was not required from memory so it was eliminated from question.
The condenser becomes unavailable for turbine bypass         Zomment incorporated.
Switch question 27 with question 92 because with suggested changes to the stem of question 27 associated with A!%
valve operation at 5 Hg condenser vacuum, thus the condenser will be available for use for the given plant conditions. The correct answer is thus B and not D.
flow rate being at maximum and S/G levels at 40% and lowering, this question could be an SRO level question.
Question revised by changing distractor C & D to 1 . I       Zompromised on current times for alarm setpoint                                     question form during 5/6 neetina w/ Palisades.
Questions were not switched. New question replaces Q#27
                                                                ~          ~          ~
: 1) Remove A plant fire drill is in progress just outside of the Turbine Building from the question stem, since it adds no value.
Alarm part of question was not required from memory so       Zompromised on current it was eliminated from question.                            question form during 516 neeting w/ Palisades.
: 2) In the question stem, change the phrase how will Primary Coolant Pump (PCP) parameter(s) change to how will Primary Coolant Pumps be affected, since distractors C and D are not associated with parameters.
Switch question 27 with question 92 because with             Zan NOT switch questions suggested changes to the stem of question 27                 27 and 92, since Q27 is a associated with A!% flow rate being at maximum and           3roup 2 Tier 1 Generic S/G levels at 40% and lowering, this question could be       question and Q92 is a an SRO level question.                                        Sroup 2 Tier 2 A2 question. Switching juestions would result in Questions were not switched. New question                    :he skyscrape? number replaces Q#27                                                ,equirements on form ES-
In distractors A, B, and D, delete mention of an Action Request.
                                                              $01-2 not being met.
Resolution Zomment incorporated.
Zomment incorporated.
Zomment incorporated.
Zompromised on current question form during 5/6 neetina w/ Palisades.
~
~
~
Zompromised on current question form during 516 neeting w/ Palisades.
Zan NOT switch questions 27 and 92, since Q27 is a 3roup 2 Tier 1 Generic question and Q92 is a Sroup 2 Tier 2 A2 question. Switching juestions would result in
:he skyscrape? number  
,equirements on form ES-  
$01-2 not being met.
Ruestion to be replaced.
Ruestion to be replaced.
Question has been reDlaced.
Question has been reDlaced.
: 1) Remove A plant fire drill is in progress just outside of Zomments incorporated.
Zomments incorporated.
the Turbine Building from the question stem, since it adds no value.
Zomment incorporated.
: 2) In the question stem, change the phrase how will Primary Coolant Pump (PCP) parameter(s) change to how will Primary Coolant Pumps be affected, since distractors C and D are not associated with parameters.
Page 2 of 6  
In distractors A, B, and D, delete mention of an Action      Zomment incorporated.
Request.
Page 2 of 6


PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS Comment                                   Resolution Replace question because flow would not have been       Question was replaced isolated to the CC Hx for the given set of conditions     with question suggested by stated in the auestion stem.                              the facility.
PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS Comment Replace question because flow would not have been isolated to the CC Hx for the given set of conditions stated in the auestion stem.
Terminology changes incorporated.                        Comments incorporated.
Terminology changes incorporated.
One of the distractors changed from 1690 to 1695 psia. Comments incorporated.
One of the distractors changed from 1690 to 1695 psia.
: 1) Change distractor B to Pressurizer steam quality     Comments NOT increases.                                               incorporated, since would
: 1) Change distractor B to Pressurizer steam quality increases.
: 2) Change distractor D to Pressurizer steam enthalpy     make distractors 6 and D will remain the same.                                    also correct answers.
: 2) Change distractor D to Pressurizer steam enthalpy will remain the same.
: 1) Add to question stem thatPZR level is off scale low Comments incorporated.
: 1) Add to question stem thatPZR level is off scale low as clarifying information to ensure applicants realize PZR pressure should be below the SI setpoint.
as clarifying information to ensure applicants realize PZR pressure should be below the SI setpoint.
: 2) Add to question stem that NO immediate actions have been taken.
: 2) Add to question stem that NO immediate actions have been taken.
In the distractors change Train 1 to Left Train and Comment incorporated.
In the distractors change Train 1 to Left Train and chanae Train 2 to Right Train.
chanae Train 2 to Right Train.
Question is not accurate. PCS needs to be vented. It does not need to be < 200F and vented.
Question is not accurate. PCS needs to be vented. It     Comments incorporated.
Recommend change that is more operationally complete and valid. (Stroke times of valves changed)
does not need to be < 200F and vented.
Revise distractors to incorporate plant nomenclature.  
Recommend change that is more operationally complete Compromised on current and valid. (Stroke times of valves changed)               question form during 5/6/05 meeting with Palisades.
~
Revise distractors to incorporate plant nomenclature. Comment incorporated.
Alter question slightly to ask what plant service water loads have the greatest flow rates associated with them as opposed to which components are isolated per an attachment in ONP-6.1, Loss of Service Water Drocedure.
                    ~
Resolution Question was replaced with question suggested by the facility.
Alter question slightly to ask what plant service water Comment incorporated.
Comments incorporated.
loads have the greatest flow rates associated with them as opposed to which components are isolated per an attachment in ONP-6.1, Loss of Service Water Drocedure.
Comments incorporated.
Page3of 6
Comments NOT incorporated, since would make distractors 6 and D also correct answers.
Comments incorporated.
Comment incorporated.
Comments incorporated.
Compromised on current question form during 5/6/05 meeting with Palisades.
Comment incorporated.
Comment incorporated.
Page3of 6  


PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS Comment                                   Resolution Change distractors to reflect that P-8C may not trip       Comment incorporated.
PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS Comment Change distractors to reflect that P-8C may not trip based on the conditions in the question stem.
based on the conditions in the question stem.
Valve numbers changed to include zero. CV-736 was changed to CV-0736 Change question stem so that C-2C Station Air Compressor is 00s instead of running (to reflect the current practice of having only one SAC normally running).
Valve numbers changed to include zero. CV-736 was changed to CV-0736 Change question stem so that C-2C Station Air             Comment incorporated.
: 1) Since main feedwater is always isolated following a Rx trip, AFW will be controlling S/G levels following a Rx trip. Thus, distractor B is the correct answer and not distractor D.
Compressor is 00s instead of running (to reflect the current practice of having only one SAC normally running).
: 2) In the question stem, add EOP-I.O Immediate Actions have been ComDleted.
: 1) Since main feedwater is always isolated following a     Comments incorporated.
Need to specify ALL Containment Spray pumps are operatina.
Rx trip, AFW will be controlling S/G levels following a Rx trip. Thus, distractor B is the correct answer and not distractor D.
Tech. issue. Recommended change to align with procedure.
: 2) In the question stem, add EOP-I .O Immediate Actions have been ComDleted.
An applicant should have to know which CW Pump feeds which side (east or west) of the condenser. The distractors should be changed to eliminate this requirement from the question.
Need to specify ALL Containment Spray pumps are           Comment incorporated.
In the question stem, change Containment air temperature is currently at Tech Spec limit to 140&deg;F to eliminate the need to know the max allowable containment air temperature from memory.
operatina.
Operationally invalid. Revise question.
Tech. issue. Recommended change to align with             Comment incorporated.
Recommend replacement question that is more operational in nature.
procedure.
Change distractors to delete mention of isolating CCW to the SFP Hx, due to the way ONP-6.2 is implemented, with no CCW available.
An applicant should have to know which CW Pump             Comment incorporated.
Resolution Comment incorporated.
feeds which side (east or west) of the condenser. The distractors should be changed to eliminate this requirement from the question.
Comment incorporated.
In the question stem, change Containment air             Comment incorporated.
Comments incorporated.
temperature is currently at Tech Spec limit to 140&deg;F to eliminate the need to know the max allowable containment air temperature from memory.
Comment incorporated.
Operationally invalid. Revise question.                    Revision incorporated.
Comment incorporated.
Recommend replacement question that is more               Revision incorporated.
Comment incorporated.
operational in nature.
Comment incorporated.
Change distractors to delete mention of isolating CCW     Comment incorporated.
Revision incorporated.
to the SFP Hx, due to the way ONP-6.2 is implemented, with no CCW available.
Revision incorporated.
Page 4 of 6
Comment incorporated.
Page 4 of 6  


PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS 1
PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS 82 1
Comment                                 Resolution In the question stem, add that Bus 1D de-energized       Comment incorporated.
Change distractor D (correct answer) from a Reactor trip due to High PZR pressure instead of from High PZR level.
following the Reactor trip (this will indicate that boric acid pumps will not be available due to Bus 1D being de-eneraized).
Comment In the question stem, add that Bus 1 D de-energized following the Reactor trip (this will indicate that boric acid pumps will not be available due to Bus 1 D being de-eneraized).  
                                  ~~
~~
did not think the original question was       Revision incorporated.
83 Resolution Comment incorporated.
: 1) In the question stem, add that shutdown rods are being withdrawn.
: 2) In distractors B and D, add the word Immediately at the beginning of the distractors.
~~
did not think the original question was Revision incorporated.
operationallv valid. Replaced auestion.
operationallv valid. Replaced auestion.
79 I Distractor D is the correct answer for this question and not distractor C.
88 Recommend changes to improve clarity.
Distractor D is the correct answer for this question and Comment incorporated.
79 I not distractor C.
Comments incorporated.
Comment incorporated.
Comment incorporated.
82  Change distractor D (correct answer) from a Reactor trip  Comment incorporated.
Comments incorporated.
due to High PZR pressure instead of from High PZR level.
1 Recommend changes to enhance accuracy & clarity.
~~
Change distractors A and D to indicate PCP P-50A is a possible pump that could supply spray valve CV-1057.
83  1) In the question stem, add that shutdown rods are      Comments incorporated.
Comments incorporated Comment partially incorporated. Revised distractors so that one must determine which PCP (A, B, C, or D) must be tripped if spray valve CV-IO57 fails open.
being withdrawn.
Page 5 of 6  
: 2) In distractors B and D, add the word Immediately at the beginning of the distractors.
1 Recommend changes to enhance accuracy & clarity.         Comments incorporated Change distractors A and D to indicate PCP P-50A is a     Comment partially possible pump that could supply spray valve CV-1057.     incorporated. Revised distractors so that one must determine which PCP (A, B, C, or D) must be tripped if spray valve CV-IO57 fails open.
88  Recommend changes to improve clarity.                    Comments incorporated.
Page 5 of 6


PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRllTEN EXAM COMMENTS Comment                               Resolution Switch question 27 with question 92 because with     Can NOT switch questions juggested changes to the stem of question 27         27 and 92, since Q27 is a msociated with AFW flow rate being at maximum and     Group 2 Tier 1 Generic YG levels at 40% and lowering, this question could be question and Q92 is a Sn SRO level question.                                Group 2 Tier 2 A2 question. Switching questions would result in the "skyscraper" number requirements on form ES-401-2 not being met.
PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRllTEN EXAM COMMENTS Comment Switch question 27 with question 92 because with juggested changes to the stem of question 27 msociated with AFW flow rate being at maximum and YG levels at 40% and lowering, this question could be Sn SRO level question.
Need to revise old Question 92 to add procedure transition Westion was not switched with 27. Original           references.
Westion was not switched with 27. Original question was revised to make it an SRO level guestion.
question was revised to make it an SRO level guestion.
Recommend a more ODerationallv valid auestion.  
Recommend a more ODerationallv valid auestion.        Comment incorporated.
~  
~       ~
~
Shange question stem to indicate that Unidentified   Open item: Verify
Shange question stem to indicate that Unidentified  
-eakage is occurring. Site indicated that any leakage Palisades leak rate nto the Quench tank is considered Unidentified     procedure states that Leakage, and thus distractor B is the correct answer leakage into Quench tank and not distractor A.                                is unidentified. Item closed.
-eakage is occurring. Site indicated that any leakage nto the Quench tank is considered Unidentified Leakage, and thus distractor B is the correct answer and not distractor A.
Based on Palisades input question was changed to reflect leakage into Quench Tank as Unidentified.
Based on Palisades input question was changed to reflect leakage into Quench Tank as Unidentified.
Palisades recommends a more operationally valid       New question incorporated.
Palisades recommends a more operationally valid westion.
westion.
Resolution Can NOT switch questions 27 and 92, since Q27 is a Group 2 Tier 1 Generic question and Q92 is a Group 2 Tier 2 A2 question. Switching questions would result in the "skyscraper" number requirements on form ES-401-2 not being met.
Need to revise old Question 92 to add procedure transition references.
Comment incorporated.
Open item: Verify Palisades leak rate procedure states that leakage into Quench tank is unidentified. Item closed.
New question incorporated.
Page 6 of 6}}
Page 6 of 6}}

Latest revision as of 16:08, 15 January 2025

Facility Comments to the NRC-Proposed Palisades Initial Written Examination - May 2005 the Facility Did Not Provide Any Written Comments to the NRC-Proposed Operating Test
ML052240175
Person / Time
Site: Palisades 
Issue date: 05/23/2005
From: Domonique Malone
Nuclear Management Co
To:
NRC/RGN-III/DRS/OLB
Shared Package
ML051930236 List:
References
50-255/05-301 50-255/05-301
Download: ML052240175 (7)


Text

FACILITY COMMENTS TO THE NRC-PROPOSED PALISADES INITIAL WRITTEN EXAMINATION - MAY 2005 THE FACILITY DID NOT PROVIDE ANY WRITTEN COMMENTS TO THE NRC-PROPOSED OPERATING TEST.

PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS

~~

Comment

1) Revise question stem for clarity by stating PT-01028 fails low and no operator action is taken, as opposed to knowing that the channel was placed in trip after 8 days of being inoperable.
2) Also, in distractors A and B revise NI RPS function to affected RPS trip function.

Remove Quench tank temp is 106F and increasing very slowly from the question stem.

Tech incorrect. As Pzr level rises, charging flow lowers and letdown flow will rise.

Distractor D was also a correct answer per EOP-4.0.

Question resived.

RVLMS design cannot indicate in given increments, stem should indicate RVLMS reading of 71 Remove Turbine Building temperature and pressure are increasing from the question stem, since it adds no value.

1) In the question stem, change Main Control Board indication(s) to indication(s).
2) Change distractor C to: ONLY Amperage indications for Battery No. 1 can be used.

Power level was included to clarifv mode of applicability.

Conflicting references between DBD 5.02, 3.3.2 and ONP-2.3. Sys. Eng. was contacted regarding question and auestion was revised.

Revise question to state that the CC system is unavailable as opposed to stating a total loss of CCW has occurred.

A plant modification has changed the way the Instrument Air System is operated. Alter question to reflect current way plant operates (1 SAC running as opposed to 2 SACS running).

Resolution Comments incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated Comment incorporated Comment incorporated, Comments incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated Comment incorporated.

Page 1 of 6

PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRllTEN EXAM COMMENTS Comment Revise from asking what makes a control rod operable to asking if given conditions make the rod inoperable.

In distractors A and B, change 525°F to 524°F to agree with EOPs.

The condenser becomes unavailable for turbine bypass valve operation at 5 Hg condenser vacuum, thus the condenser will be available for use for the given plant conditions. The correct answer is thus B and not D.

Question revised by changing distractor C & D to 1.I times for alarm setpoint Alarm part of question was not required from memory so it was eliminated from question.

Switch question 27 with question 92 because with suggested changes to the stem of question 27 associated with A!%

flow rate being at maximum and S/G levels at 40% and lowering, this question could be an SRO level question.

Questions were not switched. New question replaces Q#27

1) Remove A plant fire drill is in progress just outside of the Turbine Building from the question stem, since it adds no value.
2) In the question stem, change the phrase how will Primary Coolant Pump (PCP) parameter(s) change to how will Primary Coolant Pumps be affected, since distractors C and D are not associated with parameters.

In distractors A, B, and D, delete mention of an Action Request.

Resolution Zomment incorporated.

Zomment incorporated.

Zomment incorporated.

Zompromised on current question form during 5/6 neetina w/ Palisades.

~

~

~

Zompromised on current question form during 516 neeting w/ Palisades.

Zan NOT switch questions 27 and 92, since Q27 is a 3roup 2 Tier 1 Generic question and Q92 is a Sroup 2 Tier 2 A2 question. Switching juestions would result in

he skyscrape? number

,equirements on form ES-

$01-2 not being met.

Ruestion to be replaced.

Question has been reDlaced.

Zomments incorporated.

Zomment incorporated.

Page 2 of 6

PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS Comment Replace question because flow would not have been isolated to the CC Hx for the given set of conditions stated in the auestion stem.

Terminology changes incorporated.

One of the distractors changed from 1690 to 1695 psia.

1) Change distractor B to Pressurizer steam quality increases.
2) Change distractor D to Pressurizer steam enthalpy will remain the same.
1) Add to question stem thatPZR level is off scale low as clarifying information to ensure applicants realize PZR pressure should be below the SI setpoint.
2) Add to question stem that NO immediate actions have been taken.

In the distractors change Train 1 to Left Train and chanae Train 2 to Right Train.

Question is not accurate. PCS needs to be vented. It does not need to be < 200F and vented.

Recommend change that is more operationally complete and valid. (Stroke times of valves changed)

Revise distractors to incorporate plant nomenclature.

~

Alter question slightly to ask what plant service water loads have the greatest flow rates associated with them as opposed to which components are isolated per an attachment in ONP-6.1, Loss of Service Water Drocedure.

Resolution Question was replaced with question suggested by the facility.

Comments incorporated.

Comments incorporated.

Comments NOT incorporated, since would make distractors 6 and D also correct answers.

Comments incorporated.

Comment incorporated.

Comments incorporated.

Compromised on current question form during 5/6/05 meeting with Palisades.

Comment incorporated.

Comment incorporated.

Page3of 6

PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS Comment Change distractors to reflect that P-8C may not trip based on the conditions in the question stem.

Valve numbers changed to include zero. CV-736 was changed to CV-0736 Change question stem so that C-2C Station Air Compressor is 00s instead of running (to reflect the current practice of having only one SAC normally running).

1) Since main feedwater is always isolated following a Rx trip, AFW will be controlling S/G levels following a Rx trip. Thus, distractor B is the correct answer and not distractor D.
2) In the question stem, add EOP-I.O Immediate Actions have been ComDleted.

Need to specify ALL Containment Spray pumps are operatina.

Tech. issue. Recommended change to align with procedure.

An applicant should have to know which CW Pump feeds which side (east or west) of the condenser. The distractors should be changed to eliminate this requirement from the question.

In the question stem, change Containment air temperature is currently at Tech Spec limit to 140°F to eliminate the need to know the max allowable containment air temperature from memory.

Operationally invalid. Revise question.

Recommend replacement question that is more operational in nature.

Change distractors to delete mention of isolating CCW to the SFP Hx, due to the way ONP-6.2 is implemented, with no CCW available.

Resolution Comment incorporated.

Comment incorporated.

Comments incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Revision incorporated.

Revision incorporated.

Comment incorporated.

Page 4 of 6

PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRITTEN EXAM COMMENTS 82 1

Change distractor D (correct answer) from a Reactor trip due to High PZR pressure instead of from High PZR level.

Comment In the question stem, add that Bus 1 D de-energized following the Reactor trip (this will indicate that boric acid pumps will not be available due to Bus 1 D being de-eneraized).

~~

83 Resolution Comment incorporated.

1) In the question stem, add that shutdown rods are being withdrawn.
2) In distractors B and D, add the word Immediately at the beginning of the distractors.

~~

did not think the original question was Revision incorporated.

operationallv valid. Replaced auestion.

88 Recommend changes to improve clarity.

Distractor D is the correct answer for this question and Comment incorporated.

79 I not distractor C.

Comments incorporated.

Comment incorporated.

Comments incorporated.

1 Recommend changes to enhance accuracy & clarity.

Change distractors A and D to indicate PCP P-50A is a possible pump that could supply spray valve CV-1057.

Comments incorporated Comment partially incorporated. Revised distractors so that one must determine which PCP (A, B, C, or D) must be tripped if spray valve CV-IO57 fails open.

Page 5 of 6

PALISADES MAY/JUNE 2005 INITIAL LICENSE EXAM FACILITY WRllTEN EXAM COMMENTS Comment Switch question 27 with question 92 because with juggested changes to the stem of question 27 msociated with AFW flow rate being at maximum and YG levels at 40% and lowering, this question could be Sn SRO level question.

Westion was not switched with 27. Original question was revised to make it an SRO level guestion.

Recommend a more ODerationallv valid auestion.

~

~

Shange question stem to indicate that Unidentified

-eakage is occurring. Site indicated that any leakage nto the Quench tank is considered Unidentified Leakage, and thus distractor B is the correct answer and not distractor A.

Based on Palisades input question was changed to reflect leakage into Quench Tank as Unidentified.

Palisades recommends a more operationally valid westion.

Resolution Can NOT switch questions 27 and 92, since Q27 is a Group 2 Tier 1 Generic question and Q92 is a Group 2 Tier 2 A2 question. Switching questions would result in the "skyscraper" number requirements on form ES-401-2 not being met.

Need to revise old Question 92 to add procedure transition references.

Comment incorporated.

Open item: Verify Palisades leak rate procedure states that leakage into Quench tank is unidentified. Item closed.

New question incorporated.