ML16343A408: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 14: Line 14:
| document type = Updated Final Safety Analysis Report (UFSAR)
| document type = Updated Final Safety Analysis Report (UFSAR)
| page count = 2
| page count = 2
}}
=Text=
{{#Wiki_filter: IINNDDIIAANNAA  AANNDD  MMIICCHHIIGGAANN  PPOOWWEERR  DD.. CC.. CCOOOOKK  NNUUCCLLEEAARR  PPLLAANNTT  UUPPDDAATTEEDD  FFIINNAALL  SSAAFFEETTYY  AANNAALLYYSSIISS  RREEPPOORRTT  Revision: 23Table: 14.2.5-3 Page: 1 of 2 UNIT 1 PARAMETERS USED FOR THE OFFSITE RADIOLOGICAL CONSEQUENCE ANALYSIS OF A MAIN STEAM LINE BREAK Parameter Value Core Power Level 3480 MWt Primary Coolant Limit for Normal Operation  Iodines 1.0 µCi/gm DE I-131  Noble Gases 1% failed fuel Secondary Coolant Limit for Normal Operation  Iodines 0.1 µCi/gm DE I-131 Pre-Accident Iodine Spike  Primary Coolant Iodine Concentration 60 µCi/gm DE I-131 Concurrent Iodine Spike  Primary Coolant Iodine Appearance Rate Multiplier 500  Spike Duration 8 hr Primary Coolant Mass 2.265E+08 g Initial Faulted Steam Generator Mass 7.303E+07 g Initial Intact Steam Generator Mass 1.238E+08 g Primary-to-Secondary Leak Rate 150 gpd per Steam Generator Break Location Upstream of MSIV  Faulted Steam Generator Steam Release    0 hr Entire Steam Generator Inventory  0 - 8 hr Primary-to-Secondary Leakage  Release Location Containment Building Break Location Downstream of MSIV  Faulted Steam Generator Steam Release    0 min Entire Steam Generator Inventory  0 - 30 min Primary-to-Secondary Leakage  Release Location for EAB Turbine Building  Release Location for LPZ Auxiliary Building Intact Steam Generator Steam Release  0 - 2 hr 456,000 lbm  2 - 8 hr 1,186,000 lbm  Release Location Containment Building Partition Coefficients  Iodines in Faulted Steam Generator  1  Iodines in Intact Steam Generator  100  Noble Gases 1 IINNDDIIAANNAA  AANNDD  MMIICCHHIIGGAANN  PPOOWWEERR  DD.. CC.. CCOOOOKK  NNUUCCLLEEAARR  PPLLAANNTT  UUPPDDAATTEEDD  FFIINNAALL  SSAAFFEETTYY  AANNAALLYYSSIISS  RREEPPOORRTT  Revision: 23Table: 14.2.5-3 Page: 2 of 2 UNIT 1 PARAMETERS USED FOR THE OFFSITE RADIOLOGICAL CONSEQUENCE ANALYSIS OF A MAIN STEAM LINE BREAK Parameter Value Iodine Chemical Form  Elemental 97%  Organic 3% Breathing Rate 3.5E-04 m3/sec 
}}
}}

Revision as of 13:34, 1 May 2018

Donald C. Cook Nuclear Plant, Units 1 & 2, Revision 27 to Updated Final Safety Analysis Report, Chapter 14, Table 14.2.5-3
ML16343A408
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16343A408 (2)


Text

IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 23Table: 14.2.5-3 Page: 1 of 2 UNIT 1 PARAMETERS USED FOR THE OFFSITE RADIOLOGICAL CONSEQUENCE ANALYSIS OF A MAIN STEAM LINE BREAK Parameter Value Core Power Level 3480 MWt Primary Coolant Limit for Normal Operation Iodines 1.0 µCi/gm DE I-131 Noble Gases 1% failed fuel Secondary Coolant Limit for Normal Operation Iodines 0.1 µCi/gm DE I-131 Pre-Accident Iodine Spike Primary Coolant Iodine Concentration 60 µCi/gm DE I-131 Concurrent Iodine Spike Primary Coolant Iodine Appearance Rate Multiplier 500 Spike Duration 8 hr Primary Coolant Mass 2.265E+08 g Initial Faulted Steam Generator Mass 7.303E+07 g Initial Intact Steam Generator Mass 1.238E+08 g Primary-to-Secondary Leak Rate 150 gpd per Steam Generator Break Location Upstream of MSIV Faulted Steam Generator Steam Release 0 hr Entire Steam Generator Inventory 0 - 8 hr Primary-to-Secondary Leakage Release Location Containment Building Break Location Downstream of MSIV Faulted Steam Generator Steam Release 0 min Entire Steam Generator Inventory 0 - 30 min Primary-to-Secondary Leakage Release Location for EAB Turbine Building Release Location for LPZ Auxiliary Building Intact Steam Generator Steam Release 0 - 2 hr 456,000 lbm 2 - 8 hr 1,186,000 lbm Release Location Containment Building Partition Coefficients Iodines in Faulted Steam Generator 1 Iodines in Intact Steam Generator 100 Noble Gases 1 IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 23Table: 14.2.5-3 Page: 2 of 2 UNIT 1 PARAMETERS USED FOR THE OFFSITE RADIOLOGICAL CONSEQUENCE ANALYSIS OF A MAIN STEAM LINE BREAK Parameter Value Iodine Chemical Form Elemental 97% Organic 3% Breathing Rate 3.5E-04 m3/sec