ML16343A408: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 14: | Line 14: | ||
| document type = Updated Final Safety Analysis Report (UFSAR) | | document type = Updated Final Safety Analysis Report (UFSAR) | ||
| page count = 2 | | page count = 2 | ||
}} | |||
=Text= | |||
{{#Wiki_filter: IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 23Table: 14.2.5-3 Page: 1 of 2 UNIT 1 PARAMETERS USED FOR THE OFFSITE RADIOLOGICAL CONSEQUENCE ANALYSIS OF A MAIN STEAM LINE BREAK Parameter Value Core Power Level 3480 MWt Primary Coolant Limit for Normal Operation Iodines 1.0 µCi/gm DE I-131 Noble Gases 1% failed fuel Secondary Coolant Limit for Normal Operation Iodines 0.1 µCi/gm DE I-131 Pre-Accident Iodine Spike Primary Coolant Iodine Concentration 60 µCi/gm DE I-131 Concurrent Iodine Spike Primary Coolant Iodine Appearance Rate Multiplier 500 Spike Duration 8 hr Primary Coolant Mass 2.265E+08 g Initial Faulted Steam Generator Mass 7.303E+07 g Initial Intact Steam Generator Mass 1.238E+08 g Primary-to-Secondary Leak Rate 150 gpd per Steam Generator Break Location Upstream of MSIV Faulted Steam Generator Steam Release 0 hr Entire Steam Generator Inventory 0 - 8 hr Primary-to-Secondary Leakage Release Location Containment Building Break Location Downstream of MSIV Faulted Steam Generator Steam Release 0 min Entire Steam Generator Inventory 0 - 30 min Primary-to-Secondary Leakage Release Location for EAB Turbine Building Release Location for LPZ Auxiliary Building Intact Steam Generator Steam Release 0 - 2 hr 456,000 lbm 2 - 8 hr 1,186,000 lbm Release Location Containment Building Partition Coefficients Iodines in Faulted Steam Generator 1 Iodines in Intact Steam Generator 100 Noble Gases 1 IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 23Table: 14.2.5-3 Page: 2 of 2 UNIT 1 PARAMETERS USED FOR THE OFFSITE RADIOLOGICAL CONSEQUENCE ANALYSIS OF A MAIN STEAM LINE BREAK Parameter Value Iodine Chemical Form Elemental 97% Organic 3% Breathing Rate 3.5E-04 m3/sec | |||
}} | }} |
Revision as of 13:34, 1 May 2018
ML16343A408 | |
Person / Time | |
---|---|
Site: | Cook |
Issue date: | 10/24/2016 |
From: | Indiana Michigan Power Co |
To: | Office of Nuclear Reactor Regulation |
Shared Package | |
ML16336A263 | List:
|
References | |
AEP-NRC-2016-42 | |
Download: ML16343A408 (2) | |
Text
IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 23Table: 14.2.5-3 Page: 1 of 2 UNIT 1 PARAMETERS USED FOR THE OFFSITE RADIOLOGICAL CONSEQUENCE ANALYSIS OF A MAIN STEAM LINE BREAK Parameter Value Core Power Level 3480 MWt Primary Coolant Limit for Normal Operation Iodines 1.0 µCi/gm DE I-131 Noble Gases 1% failed fuel Secondary Coolant Limit for Normal Operation Iodines 0.1 µCi/gm DE I-131 Pre-Accident Iodine Spike Primary Coolant Iodine Concentration 60 µCi/gm DE I-131 Concurrent Iodine Spike Primary Coolant Iodine Appearance Rate Multiplier 500 Spike Duration 8 hr Primary Coolant Mass 2.265E+08 g Initial Faulted Steam Generator Mass 7.303E+07 g Initial Intact Steam Generator Mass 1.238E+08 g Primary-to-Secondary Leak Rate 150 gpd per Steam Generator Break Location Upstream of MSIV Faulted Steam Generator Steam Release 0 hr Entire Steam Generator Inventory 0 - 8 hr Primary-to-Secondary Leakage Release Location Containment Building Break Location Downstream of MSIV Faulted Steam Generator Steam Release 0 min Entire Steam Generator Inventory 0 - 30 min Primary-to-Secondary Leakage Release Location for EAB Turbine Building Release Location for LPZ Auxiliary Building Intact Steam Generator Steam Release 0 - 2 hr 456,000 lbm 2 - 8 hr 1,186,000 lbm Release Location Containment Building Partition Coefficients Iodines in Faulted Steam Generator 1 Iodines in Intact Steam Generator 100 Noble Gases 1 IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 23Table: 14.2.5-3 Page: 2 of 2 UNIT 1 PARAMETERS USED FOR THE OFFSITE RADIOLOGICAL CONSEQUENCE ANALYSIS OF A MAIN STEAM LINE BREAK Parameter Value Iodine Chemical Form Elemental 97% Organic 3% Breathing Rate 3.5E-04 m3/sec