{{#Wiki_filter:TECHNICAL SPECIFICATIONS TASK FORCE TSTF                                          A JOINT OWNERS GROUP ACTIVITY DATE                                                           DRAFT TSTF-17-01 REVISION 3 PROJ0753 Attn: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
{{#Wiki_filter:11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301-984-4400, Fax: 301-984-7600 Administration by EXCEL Services Corporation TECHNICAL SPECIFICATIONS TASK FORCE A JOINT OWNERS GROUP ACTIVITY TSTF DATE DRAFT TSTF-17-01 REVISION 3 PROJ0753 Attn: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001  


==SUBJECT:==
==SUBJECT:==
Response to NRC Questions on TSTF-505-A, "Provide Risk-Informed Extended Completion Times"
Response to NRC Questions on TSTF-505-A, "Provide Risk-Informed Extended Completion Times"  


==Reference:==
==Reference:==
Line 28: Line 28:
: 1. The industry will pursue development of a companion traveler for TSTF-505-A that addresses the NRC issues with Actions related to inoperability of all trains of a TS required system. Following approval, plants that have adopted TSTF-505-A without these Actions could submit a LAR to adopt the companion traveler. Following NRC approval of the companion traveler, plants that have not adopted TSTF-505-A can adopt TSTF-505-A and the companion traveler in a single LAR.
: 1. The industry will pursue development of a companion traveler for TSTF-505-A that addresses the NRC issues with Actions related to inoperability of all trains of a TS required system. Following approval, plants that have adopted TSTF-505-A without these Actions could submit a LAR to adopt the companion traveler. Following NRC approval of the companion traveler, plants that have not adopted TSTF-505-A can adopt TSTF-505-A and the companion traveler in a single LAR.
: 2. TSTF-505-A allows licensees to choose which Action changes are included in their LAR.
: 2. TSTF-505-A allows licensees to choose which Action changes are included in their LAR.
The TSTF will recommend to the industry that until the companion traveler is approved by the NRC, licensees submitting LARs to adopt TSTF-505 follow the guidance in the attachments to this letter. Actions related to the inoperability of all trains of a TS required system should not be included in LARs submitted prior to approval of the companion traveler. Omitting these Actions and incorporating the other changes recommended in the 11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301-984-4400, Fax: 301-984-7600 Administration by EXCEL Services Corporation
The TSTF will recommend to the industry that until the companion traveler is approved by the NRC, licensees submitting LARs to adopt TSTF-505 follow the guidance in the attachments to this letter. Actions related to the inoperability of all trains of a TS required system should not be included in LARs submitted prior to approval of the companion traveler. Omitting these Actions and incorporating the other changes recommended in the  


TSTF-17-01 DATE attachments to this letter should allow timely approval of LARs. Attachment 1 contains a list of the Actions revised by TSTF-505-A that should be omitted in LARs submitted prior to approval of the companion traveler. Attachment 1 also includes conforming changes to the TSTF-505-A Section 1.3 TS example and the TS Section 5.5 Administrative Controls program. Attachment 2 contains a list of Actions revised by TSTF-505-A that have conditions on their inclusion in a plant-specific LAR. Attachment 3 contains a revised Mode Application for requesting adoption of TSTF-505-A.
TSTF-17-01 DATE attachments to this letter should allow timely approval of LARs. Attachment 1 contains a list of the Actions revised by TSTF-505-A that should be omitted in LARs submitted prior to approval of the companion traveler. Attachment 1 also includes conforming changes to the TSTF-505-A Section 1.3 TS example and the TS Section 5.5 Administrative Controls program. Attachment 2 contains a list of Actions revised by TSTF-505-A that have conditions on their inclusion in a plant-specific LAR. Attachment 3 contains a revised Mode Application for requesting adoption of TSTF-505-A.
Line 34: Line 34:
The TSTF requests that the NRC rescind the suspension of the approval of TSTF-505-A, Revision 1, and accept LARs to adopt TSTF-505-A that follow the recommendations in the attachments to this letter.
The TSTF requests that the NRC rescind the suspension of the approval of TSTF-505-A, Revision 1, and accept LARs to adopt TSTF-505-A that follow the recommendations in the attachments to this letter.
Should you have any questions, please do not hesitate to contact us.
Should you have any questions, please do not hesitate to contact us.
James R. Morris (PWROG/W)                             Lisa L. Williams (BWROG)
James R. Morris (PWROG/W)
Otto W. Gustafson (PWROG/CE)                           Jordan Vaughan (PWROG/B&W)
Lisa L. Williams (BWROG)
Otto W. Gustafson (PWROG/CE)
Jordan Vaughan (PWROG/B&W)
Jason P. Redd (APOG)
Jason P. Redd (APOG)
Enclosure cc:     Mirella Gavrilas, Director of the Division of Safety Systems Anne T. Boland, Director of the Division of Operating Reactor Licensing Jennifer Whitman, Acting Chief of the Technical Specifications Branch Michelle Honcharik, Technical Specifications Branch
Enclosure cc:
 
Mirella Gavrilas, Director of the Division of Safety Systems Anne T. Boland, Director of the Division of Operating Reactor Licensing Jennifer Whitman, Acting Chief of the Technical Specifications Branch Michelle Honcharik, Technical Specifications Branch Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Page 1 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.1.C RPS Instrumentation Do not include Action 3.3.2.A Reactor Protection System (RPS) Manual Reactor Trip Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Specification                     Specification Title                       Notes 1.3                       Completion Times                               See attached recommended changes Action 3.3.1.C           RPS Instrumentation                           Do not include Action 3.3.2.A           Reactor Protection System (RPS) Manual Reactor Do not include.
Action 3.3.5.B ESFAS Instrumentation Do not include Action 3.3.6.B ESFAS Manual Initiation Do not include Action 3.3.11.D EFIC System Instrumentation Do not include Action 3.3.13.B EFIC Logic Do not include Action 3.3.14.B EFIC-EFW-Vector Valve Logic Do not include Action 3.4.10.A Pressurizer Safety Valves Do not include.
Trip Action 3.3.5.B           ESFAS Instrumentation                         Do not include Action 3.3.6.B           ESFAS Manual Initiation                       Do not include Action 3.3.11.D           EFIC System Instrumentation                   Do not include Action 3.3.13.B           EFIC Logic                                     Do not include Action 3.3.14.B           EFIC-EFW- Vector Valve Logic                   Do not include Action 3.4.10.A           Pressurizer Safety Valves                     Do not include.
Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.
Action 3.4.14.C           RCS Pressure Isolation Valve (PIV) Leakage     Do not include.
Action 3.5.1.A CFTs Do not include Action 3.5.1.B CFTs Do not include Action 3.5.1.C CFTs Do not include Action 3.5.2.C ECCS - Operating Do not include Action 3.5.3.B ECCS - Shutdown Do not include.
Action 3.5.1.A           CFTs                                           Do not include Action 3.5.1.B           CFTs                                           Do not include Action 3.5.1.C           CFTs                                           Do not include Action 3.5.2.C           ECCS - Operating                               Do not include Action 3.5.3.B           ECCS - Shutdown                               Do not include.
Action 3.5.4.A BWST Do not include Action 3.5.4.B BWST Do not include Action 3.6.3.B Containment Isolation Valves Do not include Action 3.6.3.D Containment Isolation Valves Do not include Action 3.6.6.F Containment Spray and Cooling Systems Do not include Action 3.7.2.C MSIVs Do not include Action 3.7.4.B AVVs Do not include.
Action 3.5.4.A           BWST                                           Do not include Action 3.5.4.B           BWST                                           Do not include Action 3.6.3.B           Containment Isolation Valves                   Do not include Action 3.6.3.D           Containment Isolation Valves                   Do not include Action 3.6.6.F           Containment Spray and Cooling Systems         Do not include Action 3.7.2.C           MSIVs                                         Do not include Action 3.7.4.B           AVVs                                           Do not include.
Action 3.7.5.C EFW System Do not include Action 3.7.6.A CST Do not include.
Action 3.7.5.C           EFW System                                     Do not include Action 3.7.6.A           CST                                           Do not include.
Action 3.7.8.B SWS Do not include Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Page 2 Specification Specification Title Notes Action 3.7.9.C UHS Do not include Action 3.7.11.B CREVS Do not include Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.
Action 3.7.8.B           SWS                                           Do not include Page 1
Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached recommended changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Page 3 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.1.C RTS Instrumentation Do not include Action 3.3.1.E RTS Instrumentation Do not include Action 3.3.1.G RTS Instrumentation Do not include Action 3.3.1.I RTS Instrumentation Do not include Action 3.3.1.Q RTS Instrumentation Do not include Action 3.3.1.S RTS Instrumentation Do not include Action 3.3.1.T RTS Instrumentation Do not include Action 3.3.1.V RTS Instrumentation Do not include Action 3.3.1.W RTS Instrumentation Do not include Action 3.3.1.Z RTS Instrumentation Do not include Action 3.3.1.CC RTS Instrumentation Do not include Action 3.3.1.EE RTS Instrumentation Do not include Action 3.3.1.JJ RTS Instrumentation Do not include Action 3.3.2.C ESFAS Instrumentation Do not include Action 3.3.2.E ESFAS Instrumentation Do not include Action 3.3.2.G ESFAS Instrumentation Do not include Action 3.3.2.I ESFAS Instrumentation Do not include Action 3.3.2.K ESFAS Instrumentation Do not include Action 3.3.2.M ESFAS Instrumentation Do not include Action 3.3.2.O ESFAS Instrumentation Do not include Action 3.3.2.Q ESFAS Instrumentation Do not include Action 3.3.2.S ESFAS Instrumentation Do not include Action 3.3.2.U ESFAS Instrumentation Do not include Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Page 4 Specification Specification Title Notes Action 3.3.2.V ESFAS Instrumentation Do not include. Required Action outside the scope of TSTF-505.
 
Action 3.3.9.B BDPS Do not include Action 3.4.9.C Pressurizer Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Specification                     Specification Title               Notes Action 3.7.9.C           UHS                                   Do not include Action 3.7.11.B           CREVS                                 Do not include Action 3.8.1.E           AC Sources - Operating                 Do not include Action 3.8.1.G           AC Sources - Operating                 Do not include Action 3.8.4.A.1         DC Sources - Operating                 Do not include. Required Action outside the scope of TSTF-505.
Action 3.4.10.A Pressurizer Safety Valves Do not include.
Action 3.8.4.D           DC Sources - Operating                 Do not include Action 3.8.7.B           Inverters - Operating                 Do not include Action 3.8.9.D           Distribution Systems - Operating       Do not include 5.5.18                   Risk Informed Completion Time Program See attached recommended changes Page 2
Action 3.4.11.E Pressurizer Power Operated Relief Valves (PORVs)
 
Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification                     Specification Title                 Notes 1.3                       Completion Times                       See attached recommended changes Action 3.3.1.C             RTS Instrumentation                   Do not include Action 3.3.1.E             RTS Instrumentation                   Do not include Action 3.3.1.G             RTS Instrumentation                   Do not include Action 3.3.1.I             RTS Instrumentation                   Do not include Action 3.3.1.Q             RTS Instrumentation                   Do not include Action 3.3.1.S             RTS Instrumentation                   Do not include Action 3.3.1.T             RTS Instrumentation                   Do not include Action 3.3.1.V             RTS Instrumentation                   Do not include Action 3.3.1.W             RTS Instrumentation                   Do not include Action 3.3.1.Z             RTS Instrumentation                   Do not include Action 3.3.1.CC           RTS Instrumentation                   Do not include Action 3.3.1.EE           RTS Instrumentation                   Do not include Action 3.3.1.JJ           RTS Instrumentation                   Do not include Action 3.3.2.C             ESFAS Instrumentation                 Do not include Action 3.3.2.E             ESFAS Instrumentation                 Do not include Action 3.3.2.G             ESFAS Instrumentation                 Do not include Action 3.3.2.I             ESFAS Instrumentation                 Do not include Action 3.3.2.K             ESFAS Instrumentation                 Do not include Action 3.3.2.M             ESFAS Instrumentation                 Do not include Action 3.3.2.O             ESFAS Instrumentation                 Do not include Action 3.3.2.Q             ESFAS Instrumentation                 Do not include Action 3.3.2.S             ESFAS Instrumentation                 Do not include Action 3.3.2.U             ESFAS Instrumentation                 Do not include Page 3
Action 3.4.11.F Pressurizer Power Operated Relief Valves (PORVs)
 
Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification                       Specification Title                   Notes Action 3.3.2.V             ESFAS Instrumentation                     Do not include. Required Action outside the scope of TSTF-505.
Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.
Action 3.3.9.B             BDPS                                       Do not include Action 3.4.9.C             Pressurizer                               Do not include.
Action 3.5.1.A Accumulators Do not include.
Action 3.4.10.A           Pressurizer Safety Valves                 Do not include.
Action 3.5.1.B Accumulators Do not include.
Action 3.4.11.E           Pressurizer Power Operated Relief Valves   Do not include.
Action 3.5.1.C Accumulators Do not include.
(PORVs)
Action 3.5.2.B ECCS - Operating Do not include.
Action 3.4.11.F           Pressurizer Power Operated Relief Valves   Do not include.
Action 3.5.3.B ECCS - Shutdown Do not include.
(PORVs)
Action 3.5.4.A RWST Do not include.
Action 3.4.14.C           RCS Pressure Isolation Valve (PIV) Leakage Do not include.
Action 3.5.4.B RWST Do not include.
Action 3.5.1.A             Accumulators                               Do not include.
Action 3.5.6.A Boron Injection Tank Do not include.
Action 3.5.1.B             Accumulators                               Do not include.
Action 3.6.3.B Containment Isolation Valves Do not include.
Action 3.5.1.C             Accumulators                               Do not include.
Action 3.6.3.C Containment Isolation Valves Do not include.
Action 3.5.2.B             ECCS - Operating                           Do not include.
Action 3.6.3.D Containment Isolation Valves Do not include.
Action 3.5.3.B             ECCS - Shutdown                           Do not include.
Action 3.6.3.E Containment Isolation Valves Do not include.
Action 3.5.4.A             RWST                                       Do not include.
Action 3.6.6A.E Containment Spray and Cooling Systems (Atmospheric and Dual)
Action 3.5.4.B             RWST                                       Do not include.
Do not include.
Action 3.5.6.A             Boron Injection Tank                       Do not include.
Action 3.6.6B.G Containment Spray and Cooling Systems (Atmospheric and Dual)
Action 3.6.3.B             Containment Isolation Valves               Do not include.
Do not include.
Action 3.6.3.C             Containment Isolation Valves               Do not include.
Action 3.6.6C.B Containment Spray System (Ice Condenser)
Action 3.6.3.D             Containment Isolation Valves               Do not include.
Do not include.
Action 3.6.3.E             Containment Isolation Valves               Do not include.
Action 3.6.6D.B QS System (Subatmospheric)
Action 3.6.6A.E           Containment Spray and Cooling Systems     Do not include.
Do not include.
(Atmospheric and Dual)
Action 3.6.6E.F RS System (Subatmospheric)
Action 3.6.6B.G           Containment Spray and Cooling Systems     Do not include.
Do not include.
(Atmospheric and Dual)
Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Page 5 Specification Specification Title Notes Action 3.6.9.B Hydrogen Mixing System Do not include.
Action 3.6.6C.B           Containment Spray System (Ice Condenser)   Do not include.
Action 3.6.10.C HIS (Ice Condenser)
Action 3.6.6D.B           QS System (Subatmospheric)                 Do not include.
Do not include.
Action 3.6.6E.F           RS System (Subatmospheric)                 Do not include.
Action 3.6.14.B ARS (Ice Condenser)
Page 4
Do not include.
 
Action 3.6.15.A Ice Bed Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Specification                       Specification Title                         Notes Action 3.6.9.B             Hydrogen Mixing System                           Do not include.
Action 3.6.17.A Divider Barrier Integrity (Ice Condenser)
Action 3.6.10.C           HIS (Ice Condenser)                             Do not include.
Do not include.
Action 3.6.14.B           ARS (Ice Condenser)                             Do not include.
Action 3.6.17.B Divider Barrier Integrity (Ice Condenser)
Action 3.6.15.A           Ice Bed                                         Do not include.
Do not include.
Action 3.6.17.A           Divider Barrier Integrity (Ice Condenser)       Do not include.
Action 3.6.18.A Containment Recirculation Drains (Ice Condenser)
Action 3.6.17.B           Divider Barrier Integrity (Ice Condenser)       Do not include.
Do not include.
Action 3.6.18.A           Containment Recirculation Drains (Ice Condenser) Do not include.
Action 3.6.18.B Containment Recirculation Drains (Ice Condenser)
Action 3.6.18.B           Containment Recirculation Drains (Ice Condenser) Do not include.
Do not include.
Action 3.7.2.C             MSIVs                                           Do not include.
Action 3.7.2.C MSIVs Do not include.
Action 3.7.5.C             AFW System                                       Do not include.
Action 3.7.5.C AFW System Do not include.
Action 3.7.6.A             Condensate Storage Tank                         Do not include.
Action 3.7.6.A Condensate Storage Tank Do not include.
Action 3.7.7.B             CCW System                                       Do not include.
Action 3.7.7.B CCW System Do not include.
Action 3.7.8.B             SWS                                             Do not include.
Action 3.7.8.B SWS Do not include.
Action 3.7.9.C             UHS                                             Do not include.
Action 3.7.9.C UHS Do not include.
Action 3.7.11.B           CREATCS                                         Do not include.
Action 3.7.11.B CREATCS Do not include.
Action 3.8.1.E             AC Sources - Operating                           Do not include Action 3.8.1.G             AC Sources - Operating                           Do not include Action 3.8.4.A.1           DC Sources - Operating                           Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.4.D             DC Sources - Operating                           Do not include Action 3.8.7.B             Inverters - Operating                           Do not include Action 3.8.9.D             Distribution Systems - Operating                 Do not include 5.5.18                     Risk Informed Completion Time Program           See attached Recommended Changes Page 5
Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached Recommended Changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Page 6 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.4.B ESFAS Instrumentation (Analog)
 
Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Specification                     Specification Title                   Notes 1.3                       Completion Times                           See attached recommended changes Action 3.3.4.B           ESFAS Instrumentation (Analog)             Do not include.
Action 3.3.5.B ESFAS Logic and Manual Trip (Analog)
Action 3.3.5.B           ESFAS Logic and Manual Trip (Analog)       Do not include.
Do not include.
Action 3.3.5.E           ESFAS Logic and Manual Trip (Analog)       Do not include.
Action 3.3.5.E ESFAS Logic and Manual Trip (Analog)
Action 3.3.6.A           ESFAS Logic and Manual Trip (Digital)     Do not include.
Do not include.
Action 3.3.6.E           ESFAS Logic and Manual Trip (Digital)     Do not include.
Action 3.3.6.A ESFAS Logic and Manual Trip (Digital)
Action 3.4.9.C           Pressurizer                               Do not include.
Do not include.
Action 3.4.10.A           Pressurizer Safety Valves                 Do not include.
Action 3.3.6.E ESFAS Logic and Manual Trip (Digital)
Action 3.4.11.E           Pressurizer Power Operated Relief Valves   Do not include.
Do not include.
(PORVs)
Action 3.4.9.C Pressurizer Do not include.
Action 3.4.11.F           Pressurizer Power Operated Relief Valves   Do not include.
Action 3.4.10.A Pressurizer Safety Valves Do not include.
(PORVs)
Action 3.4.11.E Pressurizer Power Operated Relief Valves (PORVs)
Action 3.4.14.C           RCS Pressure Isolation Valve (PIV) Leakage Do not include.
Do not include.
Action 3.5.1.A           SITs                                       Do not include.
Action 3.4.11.F Pressurizer Power Operated Relief Valves (PORVs)
Action 3.5.1.B           SITs                                       Do not include.
Do not include.
Action 3.5.1.C           SITs                                       Do not include.
Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.
Action 3.5.2.C           ECCS - Operating                           Do not include.
Action 3.5.1.A SITs Do not include.
Action 3.5.3.A           ECCS - Shutdown                           Do not include.
Action 3.5.1.B SITs Do not include.
Action 3.5.4.A           RWT                                       Do not include.
Action 3.5.1.C SITs Do not include.
Action 3.5.4.B           RWT                                       Do not include.
Action 3.5.2.C ECCS - Operating Do not include.
Action 3.6.3.C           Containment Isolation Valves               Do not include.
Action 3.5.3.A ECCS - Shutdown Do not include.
Action 3.6.3.E           Containment Isolation Valves               Do not include.
Action 3.5.4.A RWT Do not include.
Action 3.6.3.F           Containment Isolation Valves               Do not include.
Action 3.5.4.B RWT Do not include.
Action 3.6.6A.F           Containment Spray and Cooling Systems     Do not include.
Action 3.6.3.C Containment Isolation Valves Do not include.
(Atmospheric and Dual)
Action 3.6.3.E Containment Isolation Valves Do not include.
Action 3.6.6B.F           Containment Spray and Cooling Systems     Do not include.
Action 3.6.3.F Containment Isolation Valves Do not include.
(Atmospheric and Dual)
Action 3.6.6A.F Containment Spray and Cooling Systems (Atmospheric and Dual)
Action 3.6.9.B           Hydrogen Mixing System                     Do not include.
Do not include.
Action 3.7.2.C           MSIVs                                     Do not include.
Action 3.6.6B.F Containment Spray and Cooling Systems (Atmospheric and Dual)
Page 6
Do not include.
 
Action 3.6.9.B Hydrogen Mixing System Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Specification                     Specification Title               Notes Action 3.7.4.B           Atmospheric Dump Valves               Do not include.
Action 3.7.2.C MSIVs Do not include.
Action 3.7.5.C           AFW System                             Do not include.
Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Page 7 Specification Specification Title Notes Action 3.7.4.B Atmospheric Dump Valves Do not include.
Action 3.7.6.A           Condensate Storage Tank               Do not include.
Action 3.7.5.C AFW System Do not include.
Action 3.7.7.B           CCW System                             Do not include.
Action 3.7.6.A Condensate Storage Tank Do not include.
Action 3.7.8.B           SWS                                   Do not include.
Action 3.7.7.B CCW System Do not include.
Action 3.7.9.C           UHS                                   Do not include.
Action 3.7.8.B SWS Do not include.
Action 3.7.10.B           ECW                                   Do not include.
Action 3.7.9.C UHS Do not include.
Action 3.7.12.B           CREATCS                               Do not include.
Action 3.7.10.B ECW Do not include.
Action 3.8.1.E           AC Sources - Operating                 Do not include.
Action 3.7.12.B CREATCS Do not include.
Action 3.8.1.G           AC Sources - Operating                 Do not include Action 3.8.4.A.1         DC Sources - Operating                 Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.1.E AC Sources - Operating Do not include.
Action 3.8.4.D           DC Sources - Operating                 Do not include Action 3.8.7.B           Inverters - Operating                 Do not include Action 3.8.9.D           Distribution Systems - Operating       Do not include 5.5.18                   Risk Informed Completion Time Program See attached recommended changes Page 7
Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.
 
Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached recommended changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Page 8 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.1.7.A SLC System Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Specification                       Specification Title                       Notes 1.3                       Completion Times                               See attached recommended changes Action 3.1.7.A             SLC System                                     Do not include.
Action 3.1.7.C SLC System Do not include.
Action 3.1.7.C             SLC System                                     Do not include.
Action 3.3.1.1.C Reactor Protection System (RPS) Instrumentation Do not include.
Action 3.3.1.1.C           Reactor Protection System (RPS) Instrumentation Do not include.
Action 3.3.4.1.B End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Do not include.
Action 3.3.4.1.B           End of Cycle Recirculation Pump Trip (EOC-     Do not include.
Action 3.3.4.2.B Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT)
RPT) Instrumentation Action 3.3.4.2.B           Anticipated Transient Without Scram             Do not include.
Instrumentation Do not include.
Recirculation Pump Trip (ATWS-RPT)
Action 3.3.4.2.C Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT)
Instrumentation Action 3.3.4.2.C           Anticipated Transient Without Scram             Do not include.
Do not include.
Recirculation Pump Trip (ATWS-RPT)
Action 3.3.5.2.C Reactor Core Isolation Cooling (RCIC) System Instrumentation Do not include.
Action 3.3.5.2.C           Reactor Core Isolation Cooling (RCIC) System   Do not include.
Action 3.3.6.1.B Primary Containment Isolation Instrumentation Do not include.
Instrumentation Action 3.3.6.1.B           Primary Containment Isolation Instrumentation   Do not include.
Action 3.3.6.3.C LLS Instrumentation Do not include.
Action 3.3.6.3.C           LLS Instrumentation                             Do not include.
Action 3.3.6.3.D LLS Instrumentation Do not include.
Action 3.3.6.3.D           LLS Instrumentation                             Do not include.
Action 3.4.3.B S/RVs Do not include.
Action 3.4.3.B             S/RVs                                           Do not include.
Action 3.5.1.G ECCS - Operating Do not include.
Action 3.5.1.G             ECCS - Operating                               Do not include.
Action 3.5.1.I ECCS - Operating Do not include.
Action 3.5.1.I             ECCS - Operating                               Do not include.
Action 3.6.1.3.B PCIVs Do not include. Required Action outside the scope of TSTF-505.
Action 3.6.1.3.B           PCIVs                                           Do not include. Required Action outside the scope of TSTF-505.
Action 3.6.1.3.C PCIVs Do not include. Required Action outside the scope of TSTF-505.
Action 3.6.1.3.C           PCIVs                                           Do not include. Required Action outside the scope of TSTF-505.
Action 3.6.2.3.B Residual Heat Removal (RHR) Suppression Pool Cooling Do not include.
Action 3.6.2.3.B           Residual Heat Removal (RHR) Suppression Pool   Do not include.
Action 3.6.2.4.B Residual Heat Removal (RHR) Suppression Pool Spray Do not include.
Cooling Action 3.6.2.4.B           Residual Heat Removal (RHR) Suppression Pool   Do not include.
Action 3.6.3.3.B Containment Atmosphere Dilution (CAD) System Do not include.
Spray Action 3.6.3.3.B           Containment Atmosphere Dilution (CAD) System   Do not include.
Action 3.7.1.D Residual Heat Removal Service Water (RHRSW)
Action 3.7.1.D             Residual Heat Removal Service Water (RHRSW)     Do not include.
System Do not include.
System Action 3.7.2.F             [PSW] System and [UHS]                         Do not include.
Action 3.7.2.F
Action 3.7.5.B             [Control Room AC] System                       Do not include.
[PSW] System and [UHS]
Action 3.8.1.E             AC Sources - Operating                         Do not include Page 8
Do not include.
 
Action 3.7.5.B
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Specification                       Specification Title               Notes Action 3.8.1.G             AC Sources - Operating                 Do not include Action 3.8.4.A.1           DC Sources - Operating                 Do not include. Required Action outside the scope of TSTF-505.
[Control Room AC] System Do not include.
Action 3.8.4.D             DC Sources - Operating                 Do not include Action 3.8.7.B             Inverters - Operating                 Do not include Action 3.8.9.D             Distribution Systems - Operating       Do not include 5.5.15                     Risk Informed Completion Time Program See attached recommended changes Page 9
Action 3.8.1.E AC Sources - Operating Do not include Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Page 9 Specification Specification Title Notes Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.
 
Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.15 Risk Informed Completion Time Program See attached recommended changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Page 10 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.1.7.A SLC System Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Specification                       Specification Title                       Notes 1.3                       Completion Times                               See attached recommended changes Action 3.1.7.A             SLC System                                     Do not include.
Action 3.1.7.C SLC System Do not include.
Action 3.1.7.C             SLC System                                     Do not include.
Action 3.3.1.1.C Reactor Protection System (RPS) Instrumentation Do not include.
Action 3.3.1.1.C           Reactor Protection System (RPS) Instrumentation Do not include.
Action 3.3.4.1.B End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Do not include.
Action 3.3.4.1.B           End of Cycle Recirculation Pump Trip (EOC-     Do not include.
Action 3.3.4.2.B Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT)
RPT) Instrumentation Action 3.3.4.2.B           Anticipated Transient Without Scram             Do not include.
Instrumentation Do not include.
Recirculation Pump Trip (ATWS-RPT)
Action 3.3.4.2.C Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT)
Instrumentation Action 3.3.4.2.C           Anticipated Transient Without Scram             Do not include.
Instrumentation Do not include.
Recirculation Pump Trip (ATWS-RPT)
Action 3.3.5.2.C Reactor Core Isolation Cooling (RCIC) System Instrumentation Do not include.
Instrumentation Action 3.3.5.2.C           Reactor Core Isolation Cooling (RCIC) System   Do not include.
Action 3.3.6.1.B Primary Containment Isolation Instrumentation Do not include.
Instrumentation Action 3.3.6.1.B           Primary Containment Isolation Instrumentation   Do not include.
Action 3.3.6.4.B Suppression Pool Makeup (SPMU) System Instrumentation Do not include.
Action 3.3.6.4.B           Suppression Pool Makeup (SPMU) System           Do not include.
Action 3.3.6.4.C Suppression Pool Makeup (SPMU) System Instrumentation Do not include.
Instrumentation Action 3.3.6.4.C           Suppression Pool Makeup (SPMU) System           Do not include.
Action 3.3.6.5.B Relief and LLS Instrumentation Do not include.
Instrumentation Action 3.3.6.5.B           Relief and LLS Instrumentation                 Do not include.
Action 3.4.4.B S/RVs Do not include.
Action 3.4.4.B             S/RVs                                           Do not include.
Action 3.5.1.G ECCS - Operating Do not include.
Action 3.5.1.G             ECCS - Operating                               Do not include.
Action 3.5.1.I ECCS - Operating Do not include.
Action 3.5.1.I             ECCS - Operating                               Do not include.
Action 3.5.1.J ECCS - Operating Do not include.
Action 3.5.1.J             ECCS - Operating                               Do not include.
Action 3.5.1.K ECCS - Operating Do not include.
Action 3.5.1.K             ECCS - Operating                               Do not include.
Action 3.5.1.L ECCS - Operating Do not include.
Action 3.5.1.L             ECCS - Operating                               Do not include.
Action 3.6.1.3.B Primary Containment Isolation Valves (PCIVs)
Action 3.6.1.3.B           Primary Containment Isolation Valves (PCIVs)   Do not include.
Do not include.
Action 3.6.1.3.C           Primary Containment Isolation Valves (PCIVs)   Do not include.
Action 3.6.1.3.C Primary Containment Isolation Valves (PCIVs)
Action 3.6.1.3.D           Primary Containment Isolation Valves (PCIVs)   Do not include.
Do not include.
Action 3.6.1.7.B           Residual Heat Removal (RHR) Containment Spray   Do not include.
Action 3.6.1.3.D Primary Containment Isolation Valves (PCIVs)
System Action 3.6.2.3.B           Residual Heat Removal (RHR) Suppression Pool   Do not include.
Do not include.
Cooling Action 3.6.2.4.A           SPMU System                                     Do not include.
Action 3.6.1.7.B Residual Heat Removal (RHR) Containment Spray System Do not include.
Page 10
Action 3.6.2.3.B Residual Heat Removal (RHR) Suppression Pool Cooling Do not include.
 
Action 3.6.2.4.A SPMU System Do not include.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Specification                       Specification Title               Notes Action 3.6.2.4.B           SPMU System                           Do not include.
Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Page 11 Specification Specification Title Notes Action 3.6.2.4.B SPMU System Do not include.
Action 3.6.2.4.D           SPMU System                           Do not include.
Action 3.6.2.4.D SPMU System Do not include.
Action 3.6.3.1.B           Drywell Cooling System Fans           Do not include.
Action 3.6.3.1.B Drywell Cooling System Fans Do not include.
Action 3.6.3.2.B           Drywell Purge System                   Do not include.
Action 3.6.3.2.B Drywell Purge System Do not include.
Action 3.6.5.1.A           Drywell                               Do not include.
Action 3.6.5.1.A Drywell Do not include.
Action 3.6.5.3.B           Drywell Isolation Valve[s]             Do not include.
Action 3.6.5.3.B Drywell Isolation Valve[s]
Action 3.6.5.6.D           Drywell Vacuum Relief System           Do not include.
Do not include.
Action 3.6.5.6.E           Drywell Vacuum Relief System           Do not include.
Action 3.6.5.6.D Drywell Vacuum Relief System Do not include.
Action 3.6.5.6.F           Drywell Vacuum Relief System           Do not include.
Action 3.6.5.6.E Drywell Vacuum Relief System Do not include.
Action 3.7.1.D             [SSW] System and [UHS]                 Do not include.
Action 3.6.5.6.F Drywell Vacuum Relief System Do not include.
Action 3.7.4.B             [Control Room AC] System               Do not include.
Action 3.7.1.D
Action 3.8.1.E             AC Sources - Operating                 Do not include Action 3.8.1.G             AC Sources - Operating                 Do not include Action 3.8.4.A.1           DC Sources - Operating                 Do not include. Required Action outside the scope of TSTF-505.
[SSW] System and [UHS]
Action 3.8.4.D             DC Sources - Operating                 Do not include Action 3.8.7.B             Inverters - Operating                 Do not include Action 3.8.9.D             Distribution Systems - Operating       Do not include 5.5.15                     Risk Informed Completion Time Program See attached recommended changes Page 11
Do not include.
 
Action 3.7.4.B
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example
[Control Room AC] System Do not include.
  ----------------------------------------- Reviewer's Note ------------------------------------------
Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.
Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.15 Risk Informed Completion Time Program See attached recommended changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example Page 12
----------------------------------------- Reviewer's Note ------------------------------------------
Example 1.3-8 is only applicable to plants that have adopted the Risk Informed Completion Time Program.
Example 1.3-8 is only applicable to plants that have adopted the Risk Informed Completion Time Program.
  ---------------------------------------------------------------------------------------------------------
[
[ EXAMPLE 1.3-8 ACTIONS CONDITION               REQUIRED ACTION                 COMPLETION TIME A. One subsystem           A.1 Restore subsystem           7 days inoperable.                to OPERABLE status.                   OR In accordance with the Risk Informed Completion Time Program B. --- NOTE ------         B.1 Restore subsystems         1 hour Not applicable              to OPERABLE when second                status.                   OR subsystem intentionally                                          In accordance with the made                                                  Risk Informed inoperable.                                            Completion Time
EXAMPLE 1.3-8 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One subsystem inoperable.
        -------------------                                    Program Two subsystems inoperable.
A.1 Restore subsystem to OPERABLE status.
BC.Required               BC.1     Be in MODE 3.         6 hours Action and associated            AND Completion Time not met.          BC.2     Be in MODE 5.         36 hours Page 12
7 days OR In accordance with the Risk Informed Completion Time Program B. --- NOTE ------
 
Not applicable when second subsystem intentionally made inoperable.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example When a subsystem is declared inoperable, Condition A is entered. The 7 day Completion Time may be applied as discussed in Example 1.3-2. However, the licensee may elect to apply the Risk Informed Completion Time Program which permits calculation of a Risk Informed Completion Time (RICT) that may be used to complete the Required Action beyond the 7 day Completion Time. The RICT cannot exceed 30 days. After the 7 day Completion Time has expired, the subsystem must be restored to OPERABLE status within the RICT or Condition BC must also be entered.
Two subsystems inoperable.
B.1 Restore subsystems to OPERABLE status.
1 hour OR In accordance with the Risk Informed Completion Time Program BC.Required Action and associated Completion Time not met.
BC.1 Be in MODE 3.
AND BC.2 Be in MODE 5.
6 hours 36 hours Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example Page 13 When a subsystem is declared inoperable, Condition A is entered. The 7 day Completion Time may be applied as discussed in Example 1.3-2. However, the licensee may elect to apply the Risk Informed Completion Time Program which permits calculation of a Risk Informed Completion Time (RICT) that may be used to complete the Required Action beyond the 7 day Completion Time. The RICT cannot exceed 30 days. After the 7 day Completion Time has expired, the subsystem must be restored to OPERABLE status within the RICT or Condition BC must also be entered.
If a second subsystem is declared inoperable, Condition B may also be entered. The Condition is modified by a Note stating it is not applicable if the second subsystem is intentionally made inoperable. The Required Actions of Condition B are not intended for voluntary removal of redundant subsystems from service. The Required Action is only applicable if one subsystem is inoperable for any reason and the second subsystem is found to be inoperable, or if both subsystems are found to be inoperable at the same time. If Condition B is applicable, at least one subsystem must be restored to OPERABLE status within 1 hour or Condition C must also be entered. The licensee may be able to apply a RICT to extend the Completion Time beyond 1 hour if the requirements of the Risk Informed Completion Time Program are met. If two subsystems are inoperable and Condition B is not applicable (i.e., the second subsystem was intentionally made inoperable), LCO 3.0.3 is entered as there is no applicable Condition.
If a second subsystem is declared inoperable, Condition B may also be entered. The Condition is modified by a Note stating it is not applicable if the second subsystem is intentionally made inoperable. The Required Actions of Condition B are not intended for voluntary removal of redundant subsystems from service. The Required Action is only applicable if one subsystem is inoperable for any reason and the second subsystem is found to be inoperable, or if both subsystems are found to be inoperable at the same time. If Condition B is applicable, at least one subsystem must be restored to OPERABLE status within 1 hour or Condition C must also be entered. The licensee may be able to apply a RICT to extend the Completion Time beyond 1 hour if the requirements of the Risk Informed Completion Time Program are met. If two subsystems are inoperable and Condition B is not applicable (i.e., the second subsystem was intentionally made inoperable), LCO 3.0.3 is entered as there is no applicable Condition.
The Risk Informed Completion Time Program requires recalculation of the RICT to reflect changing plant conditions. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours after the plant configuration change, whichever is less.
The Risk Informed Completion Time Program requires recalculation of the RICT to reflect changing plant conditions. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours after the plant configuration change, whichever is less.
If the 7 day Completion Time clock of Condition A or the 1 hour Completion Time clock of Condition B have has expired and subsequent changes in plant condition result in exiting the applicability of the Risk Informed Completion Time Program without restoring the inoperable subsystem to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start.
If the 7 day Completion Time clock of Condition A or the 1 hour Completion Time clock of Condition B have has expired and subsequent changes in plant condition result in exiting the applicability of the Risk Informed Completion Time Program without restoring the inoperable subsystem to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start.
If the RICT expires or is recalculated to be less than the elapsed time since the Condition was entered and the inoperable subsystem has not been restored to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start. If the inoperable subsystems are restored to OPERABLE status after Condition BC is entered, Conditions A, B, and BC are exited, and therefore, the Required Actions of Condition BC may be terminated. ]
If the RICT expires or is recalculated to be less than the elapsed time since the Condition was entered and the inoperable subsystem has not been restored to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start. If the inoperable subsystems are restored to OPERABLE status after Condition BC is entered, Conditions A, B, and BC are exited, and therefore, the Required Actions of Condition BC may be terminated. ]
Page 13
Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program Page 14
 
[ 5.5.18 Risk Informed Completion Time Program This program provides controls to calculate a Risk Informed Completion Time (RICT) and must be implemented in accordance with NEI 06-09-A, Revision 0, "Risk-Managed Technical Specifications (RMTS) Guidelines." The program shall include the following:
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program
: a. The RICT may not exceed 30 days;  
[ 5.5.18   Risk Informed Completion Time Program This program provides controls to calculate a Risk Informed Completion Time (RICT) and must be implemented in accordance with NEI 06-09-A, Revision 0, "Risk-Managed Technical Specifications (RMTS) Guidelines." The program shall include the following:
--------------------------------- REVIEWER'S NOTE ----------------------------------
: a. The RICT may not exceed 30 days;
          --------------------------------- REVIEWER'S NOTE ----------------------------------
The Risk Informed Completion Time is only applicable in MODES supported by the Licensees PRA. Licensee's applying the RICT Program to MODES other than Modes 1 and 2 must demonstrate that they have the capability to calculate a RICT in those MODES or that the risk indicated by their MODE 1 and 2 PRA model is bounding with respect to the lower MODE conditions.
The Risk Informed Completion Time is only applicable in MODES supported by the Licensees PRA. Licensee's applying the RICT Program to MODES other than Modes 1 and 2 must demonstrate that they have the capability to calculate a RICT in those MODES or that the risk indicated by their MODE 1 and 2 PRA model is bounding with respect to the lower MODE conditions.
          -------------------------------------------------------------------------------------------------
: b.
: b.       A RICT may only be utilized in MODE 1, 2 [, and 3, and MODE 4 while relying on steam generators for heat removal];
A RICT may only be utilized in MODE 1, 2 [, and 3, and MODE 4 while relying on steam generators for heat removal];
: c.       When a RICT is being used, any change to the plant configuration, as defined in NEI 06-09-A, Appendix A, change within the scope of the Risk Informed Completion Time Program must be considered for the effect on the RICT.
: c.
When a RICT is being used, any change to the plant configuration, as defined in NEI 06-09-A, Appendix A, change within the scope of the Risk Informed Completion Time Program must be considered for the effect on the RICT.
: 1. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration.
: 1. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration.
: 2. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours after the plant configuration change, whichever is less.
: 2. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours after the plant configuration change, whichever is less.
: 3. Revising the RICT is not required If the plant configuration change would lower plant risk and would result in a longer RICT.
: 3. Revising the RICT is not required If the plant configuration change would lower plant risk and would result in a longer RICT.
: d.       Use of a RICT is not permitted for voluntary entry into a configuration which represents a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE.
: d.
: e.       Use of a RICT is permitted for emergent conditions which represent a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE if one or more of the trains are considered "PRA functional" as defined in Section 2.3.1 of NEI 06-09.]
Use of a RICT is not permitted for voluntary entry into a configuration which represents a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE.
Page 14
: e.
 
Use of a RICT is permitted for emergent conditions which represent a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE if one or more of the trains are considered "PRA functional" as defined in Section 2.3.1 of NEI 06-09.]
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program
Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program Page 15
: d.     If the extent of condition evaluation for inoperable structures, systems, or components (SSCs) is not complete prior to exceeding the Completion Time, the RICT shall account for the increased possibility of common cause failure (CCF) by either:
: d.
If the extent of condition evaluation for inoperable structures, systems, or components (SSCs) is not complete prior to exceeding the Completion Time, the RICT shall account for the increased possibility of common cause failure (CCF) by either:
: 1. Numerically accounting for the increased possibility of CCF in the RICT calculation; or
: 1. Numerically accounting for the increased possibility of CCF in the RICT calculation; or
: 2. Risk Management Actions (RMAs) not already credited in the RICT calculation shall be implemented that support redundant or diverse SSCs that perform the function(s) of the inoperable SSCs, and, if practicable, reduce the frequency of initiating events that challenge the function(s) performed by the inoperable SSCs.
: 2. Risk Management Actions (RMAs) not already credited in the RICT calculation shall be implemented that support redundant or diverse SSCs that perform the function(s) of the inoperable SSCs, and, if practicable, reduce the frequency of initiating events that challenge the function(s) performed by the inoperable SSCs.
: e.     [This paragraph will describe when prior NRC approval is needed for changes to the methodology used to calculate a RICT. The wording for this provision is currently under discussion between the NRC and the industry.]
: e.
[This paragraph will describe when prior NRC approval is needed for changes to the methodology used to calculate a RICT. The wording for this provision is currently under discussion between the NRC and the industry.]
Discussion of Recommended Changes to the Risk Informed Completion Time Program
Discussion of Recommended Changes to the Risk Informed Completion Time Program
: 1. The reference to NEI 06-09 is revised to refer to the approved version, NEI 06-09-A, Revision 0.
: 1.
: 2. Paragraphs d. and e. of TSTF-505 are deleted. These paragraphs discuss determining a RICT when all trains of a system are inoperable and are not applicable to the near-term submittals that are the subject of this letter.
The reference to NEI 06-09 is revised to refer to the approved version, NEI 06-09-A, Revision
: 3. The NRC questioned the difference between the TSTF-505 Risk Informed Completion Time (RICT) Program in paragraph 5.5.c and the NEI 06-09 Configuration Risk Management Program (CRMP). The traveler justification stated that the TS Section 5.5 RICT Program was the same as the NEI 06-09 CRMP; however, users of the TS may not have TSTF-505 available, which may lead to confusion when applying NEI 06-09 in accordance with the TS 5.5 RICT Program. The program was revised to clarify the application of the requirements.
: 0.
: 4. A new paragraph d. is added addressing common cause failure considerations.
: 2.
: 5. A new paragraph e. is added. The NRC's Safety Evaluation for NEI 06-09 stated:
Paragraphs d. and e. of TSTF-505 are deleted. These paragraphs discuss determining a RICT when all trains of a system are inoperable and are not applicable to the near-term submittals that are the subject of this letter.
As part of its review and approval of a licensees application requesting to implement the RMTS, the NRC staff intends to impose a license condition that will explicitly address the scope of the PRA and non-PRA methods approved by the NRC staff for use in the plant-specific RMTS program. If a licensee wishes to change its methods, and the change is outside the bounds of the license condition, the licensee will need NRC approval, via a license amendment, of the implementation of the new method in its RMTS program. The focus of the NRC staffs review and approval will be on the Page 15
: 3.
 
The NRC questioned the difference between the TSTF-505 Risk Informed Completion Time (RICT) Program in paragraph 5.5.c and the NEI 06-09 Configuration Risk Management Program (CRMP). The traveler justification stated that the TS Section 5.5 RICT Program was the same as the NEI 06-09 CRMP; however, users of the TS may not have TSTF-505 available, which may lead to confusion when applying NEI 06-09 in accordance with the TS 5.5 RICT Program. The program was revised to clarify the application of the requirements.
Attachment 1 Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program technical adequacy of the methodology and analyses relied upon for the RMTS application.
: 4.
A new paragraph d. is added addressing common cause failure considerations.
: 5.
A new paragraph e. is added. The NRC's Safety Evaluation for NEI 06-09 stated:
As part of its review and approval of a licensees application requesting to implement the RMTS, the NRC staff intends to impose a license condition that will explicitly address the scope of the PRA and non-PRA methods approved by the NRC staff for use in the plant-specific RMTS program. If a licensee wishes to change its methods, and the change is outside the bounds of the license condition, the licensee will need NRC approval, via a license amendment, of the implementation of the new method in its RMTS program. The focus of the NRC staffs review and approval will be on the Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program Page 16 technical adequacy of the methodology and analyses relied upon for the RMTS application.
There is no legal difference between a license condition and a Technical Specification and it is less error prone to put all requirements related to calculation of a RICT in the same location.
There is no legal difference between a license condition and a Technical Specification and it is less error prone to put all requirements related to calculation of a RICT in the same location.
Therefore, in lieu of a license condition, the restriction is added as paragraph e. of the program.
Therefore, in lieu of a license condition, the restriction is added as paragraph e. of the program.
Page 16
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Page 17 Specification LCO Requirements and Condition Condition on Use 3.3.8.B LCO: Three channels of loss of voltage Function and three channels of degraded voltage Function EDG LOPS instrumentation per EDG shall be OPERABLE.
 
Condition: One or more Functions with two or more channels per EDG inoperable.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification         LCO Requirements and Condition                 Condition on Use 3.3.8.B       LCO: Three channels of loss of voltage Function     Licensee must justify and three channels of degraded voltage Function     that two or more EDG LOPS instrumentation per EDG shall be           channels per EDG OPERABLE.                                           inoperable is not a Condition: One or more Functions with two or         condition in which all more channels per EDG inoperable.                   required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Licensee must justify that two or more channels per EDG inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
3.3.12.B     LCO: Two manual initiation switches per             Licensee must justify actuation channel for each of the following         that one or both emergency feedwater initiation and control (EFIC) channels inoperable is Functions shall be OPERABLE:                         not a condition in
3.3.12.B LCO: Two manual initiation switches per actuation channel for each of the following emergency feedwater initiation and control (EFIC)
: a. Steam generator (SG) A Main Feedwater (MFW) which all required Isolation,                                           trains or subsystems of
Functions shall be OPERABLE:
: b. SG B MFW Isolation,                               a TS required system
: a. Steam generator (SG) A Main Feedwater (MFW)
: c. SG A Main Steam Line Isolation,                   are inoperable or
Isolation,
: d. SG B Main Steam Line Isolation, and               modify the Action to
: b. SG B MFW Isolation,
: e. Emergency Feedwater Actuation.                   not apply a RICT when Condition: One or more EFIC Function(s) with         all required trains or one or both manual initiation switches inoperable in subsystems are both actuation channels.                             inoperable. See Note 1 at the end of Attachment 2.
: c. SG A Main Steam Line Isolation,
Page 17
: d. SG B Main Steam Line Isolation, and
 
: e. Emergency Feedwater Actuation.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification         LCO Requirements and Condition             Condition on Use 3.4.9.C       LCO: The pressurizer shall be OPERABLE.         Pressurizer is typically Condition: Capacity of pressurizer heaters     not modeled in the
Condition: One or more EFIC Function(s) with one or both manual initiation switches inoperable in both actuation channels.
[capable of being powered by emergency power   PRA. Licensee must supply] less than limit.                       justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Licensee must justify that one or both channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
3.5.2.B       LCO: Two ECCS trains shall be OPERABLE.         Licensee must justify Condition: One or more [ECCS] trains inoperable that one or more ECCS for reasons other than one LPI subsystem       trains inoperable is not inoperable.                                    a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Page 18 Specification LCO Requirements and Condition Condition on Use 3.4.9.C LCO: The pressurizer shall be OPERABLE.
Page 18
Condition: Capacity of pressurizer heaters
 
[capable of being powered by emergency power supply] less than limit.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Specification         LCO Requirements and Condition               Condition on Use 3.6.2.C       LCO: [Two] containment air lock[s] shall be       Licensee must justify OPERABLE. Condition: One or more                   that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock   not a condition in mechanism.                                        which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
Pressurizer is typically not modeled in the PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.6.6         LCO: Containment Spray and Cooling Systems         Licensee must justify Condition A: One containment spray train           the ability to calculate a inoperable                                         RICT for the condition, Condition C: One [required] containment cooling   including how the train inoperable.                                 system is modeled in Condition D: One containment spray train and one the PRA, whether all
3.5.2.B LCO: Two ECCS trains shall be OPERABLE.
[required] containment cooling train inoperable. functions of the system Condition E: Two [required] containment cooling are modeled, and, if a trains inoperable.                                surrogate is used, why that modeling is conservative.
Condition: One or more [ECCS] trains inoperable for reasons other than one LPI subsystem inoperable.
Page 19
Licensee must justify that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable.
 
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Page 19 Specification LCO Requirements and Condition Condition on Use 3.6.2.C LCO: [Two] containment air lock[s] shall be OPERABLE. Condition: One or more containment air locks inoperable for reasons other than an inoperable door or inoperable interlock mechanism.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification       LCO Requirements and Condition             Condition on Use 3.3.1.F       LCO: The RTS instrumentation for each Function Licensee must justify in Table 3.3.1-1 shall be OPERABLE.             that the condition does Condition: One Power Range Neutron Flux - High not represent the channel inoperable.                            inability to perform the safety function assumed in the FSAR given the loss of spacial distribution of the remaining Power Range detectors. The justification can include that the Actions require periodic monitoring of spacial power distribution and imposition of compensatory limits and reduced power.
Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
3.3.1.DD     LCO: The RTS instrumentation for each Function The licensee must in Table 3.3.1-1 shall be OPERABLE.             include information Condition: One RTB train inoperable.           regarding how the TSTF-411 conditions and limitations will be implemented (or similar conditions if TSTF-411 has not been adopted), including discussion of ATWS Mitigation System Actuation (AMSAC),
3.6.6 LCO: Containment Spray and Cooling Systems Condition A: One containment spray train inoperable Condition C: One [required] containment cooling train inoperable.
Condition D: One containment spray train and one
[required] containment cooling train inoperable.
Condition E: Two [required] containment cooling trains inoperable.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 20 Specification LCO Requirements and Condition Condition on Use 3.3.1.F LCO: The RTS instrumentation for each Function in Table 3.3.1-1 shall be OPERABLE.
Condition: One Power Range Neutron Flux - High channel inoperable.
Licensee must justify that the condition does not represent the inability to perform the safety function assumed in the FSAR given the loss of spacial distribution of the remaining Power Range detectors. The justification can include that the Actions require periodic monitoring of spacial power distribution and imposition of compensatory limits and reduced power.
3.3.1.DD LCO: The RTS instrumentation for each Function in Table 3.3.1-1 shall be OPERABLE.
Condition: One RTB train inoperable.
The licensee must include information regarding how the TSTF-411 conditions and limitations will be implemented (or similar conditions if TSTF-411 has not been adopted), including discussion of ATWS Mitigation System Actuation (AMSAC),
and why those actions are sufficient, including a discussion of defense in depth.
and why those actions are sufficient, including a discussion of defense in depth.
Page 20
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 21 Specification LCO Requirements and Condition Condition on Use 3.3.5.B LCO: [Three] channels per bus of the loss of voltage Function and [three] channels per bus of the degraded voltage Function shall be OPERABLE.
 
Condition: One or more Functions with two or more channels per bus inoperable.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification         LCO Requirements and Condition                 Condition on Use 3.3.5.B       LCO: [Three] channels per bus of the loss of         Licensee must justify voltage Function and [three] channels per bus of the that two or more degraded voltage Function shall be OPERABLE.         channels per bus Condition: One or more Functions with two or         inoperable is not a more channels per bus inoperable.                    condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Licensee must justify that two or more channels per bus inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
3.3.9.A       LCO: Boron Dilution Protection System (BDPS)         BDPS is typically not Condition: One train inoperable (applicable to       modeled in the PRA.
3.3.9.A LCO: Boron Dilution Protection System (BDPS)
MODES [2,] 3, 4, and 5.)                             Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Condition: One train inoperable (applicable to MODES [2,] 3, 4, and 5.)
3.4.9.B       LCO: The pressurizer shall be OPERABLE             Pressurizer is typically Condition: One [required] group of pressurizer       not modeled in the heaters inoperable.                                  PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
BDPS is typically not modeled in the PRA.
Page 21
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
 
3.4.9.B LCO: The pressurizer shall be OPERABLE Condition: One [required] group of pressurizer heaters inoperable.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification         LCO Requirements and Condition               Condition on Use 3.5.2.A       LCO: Two ECCS trains shall be OPERABLE.           Licensee must justify Condition: One or more [ECCS] trains inoperable. that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.
Pressurizer is typically not modeled in the PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.6.2.C       LCO: [Two] containment air lock[s] shall be       Licensee must justify OPERABLE. Condition: One or more                   that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock   not a condition in mechanism.                                        which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 22 Specification LCO Requirements and Condition Condition on Use 3.5.2.A LCO: Two ECCS trains shall be OPERABLE.
3.6.6A       LCO: Containment Spray and Cooling Systems         Licensee must justify (Atmospheric and Dual) (Credit taken for iodine   the ability to calculate a removal by the Containment Spray System)           RICT for the condition, Condition A: One containment spray train           including how the inoperable.                                       system is modeled in Condition C: One [required] containment cooling   the PRA, whether all train inoperable.                                 functions of the system Condition D: Two [required] containment cooling are modeled, and, if a trains inoperable.                                surrogate is used, why that modeling is conservative.
Condition: One or more [ECCS] trains inoperable.
Page 22
Licensee must justify that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.
 
3.6.2.C LCO: [Two] containment air lock[s] shall be OPERABLE. Condition: One or more containment air locks inoperable for reasons other than an inoperable door or inoperable interlock mechanism.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification         LCO Requirements and Condition               Condition on Use 3.6.6B       LCO: Containment Spray and Cooling Systems         Licensee must justify (Atmospheric and Dual (Credit not taken for iodine the ability to calculate a removal by the Containment Spray System)           RICT for the condition, Condition A: One containment spray train           including how the inoperable.                                       system is modeled in Condition B: One [required] containment cooling   the PRA, whether all train inoperable.                                 functions of the system Condition C: Two containment spray trains         are modeled, and, if a inoperable.                                       surrogate is used, why Condition D: One containment spray train and one   that modeling is
Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
[required] containment cooling train inoperable. conservative.
3.6.6A LCO: Containment Spray and Cooling Systems (Atmospheric and Dual) (Credit taken for iodine removal by the Containment Spray System)
Condition A: One containment spray train inoperable.
Condition C: One [required] containment cooling train inoperable.
Condition D: Two [required] containment cooling trains inoperable.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 23 Specification LCO Requirements and Condition Condition on Use 3.6.6B LCO: Containment Spray and Cooling Systems (Atmospheric and Dual (Credit not taken for iodine removal by the Containment Spray System)
Condition A: One containment spray train inoperable.
Condition B: One [required] containment cooling train inoperable.
Condition C: Two containment spray trains inoperable.
Condition D: One containment spray train and one
[required] containment cooling train inoperable.
Condition E: Two [required] containment cooling trains inoperable.
Condition E: Two [required] containment cooling trains inoperable.
3.6.6C.A     LCO: Containment Spray System (Ice Condenser)     Licensee must justify Condition: One containment spray train             the ability to calculate a inoperable.                                        RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.6.6D.A     LCO: Quench Spray (QS) System                     Licensee must justify (Subatmospheric)                                   the ability to calculate a Condition: One QS train inoperable                 RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.6.6C.A LCO: Containment Spray System (Ice Condenser)
Page 23
Condition: One containment spray train inoperable.
 
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Specification         LCO Requirements and Condition             Condition on Use 3.6.6E       LCO: Recirculation Spray (RS) System             Licensee must justify (Subatmospheric)                                 the ability to calculate a Condition A: One RS subsystem inoperable.       RICT for the condition, Condition B: Two RS subsystems inoperable in     including how the one train.                                       system is modeled in Condition C: Two inside RS subsystems           the PRA, whether all inoperable                                      functions of the system Condition D: Two outside RS subsystems          are modeled, and, if a inoperable.                                      surrogate is used, why Condition E: Casing cooling tank inoperable. that modeling is conservative.
3.6.6D.A LCO: Quench Spray (QS) System (Subatmospheric)
3.6.16.A     LCO: The ice condenser inlet doors, intermediate Licensee must justify deck doors, and top deck [doors] shall be       that one or more OPERABLE and closed.                             inoperable doors is not Condition: One or more ice condenser doors       a condition in which all physically restrained from opening              required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Condition: One QS train inoperable Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.7.4.B       LOC: [Three] Atmospheric Dump Valves (ADV)       Licensee must justify lines shall be OPERABLE.                         that two or more Condition: Two or more required ADV lines       inoperable ADVs is not inoperable                                      a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 24 Specification LCO Requirements and Condition Condition on Use 3.6.6E LCO: Recirculation Spray (RS) System (Subatmospheric)
Page 24
Condition A: One RS subsystem inoperable.
 
Condition B: Two RS subsystems inoperable in one train.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification         LCO Requirements and Condition             Condition on Use 3.3.6.C       LCO: [Four] channels of Loss of Voltage Function Licensee must justify (analog)      and [four] channels of Degraded Voltage Function that more than two auto-initiation instrumentation per DG shall be channels per bus OPERABLE.                                       inoperable is not a Condition: One or more Functions with more than condition in which all two channels inoperable.                        required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Condition C: Two inside RS subsystems inoperable Condition D: Two outside RS subsystems inoperable.
3.4.9.B       LCO: The pressurizer shall be OPERABLE         Pressurizer is typically Condition: One [required] group of pressurizer   not modeled in the heaters inoperable.                              PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Condition E: Casing cooling tank inoperable.
3.5.2.D       LCO: Two ECCS trains shall be OPERABLE.         Licensee must justify Condition: Less than 100% of the ECCS flow       that one or more ECCS equivalent to a single OPERABLE train available. trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Page 25
3.6.16.A LCO: The ice condenser inlet doors, intermediate deck doors, and top deck [doors] shall be OPERABLE and closed.
 
Condition: One or more ice condenser doors physically restrained from opening Licensee must justify that one or more inoperable doors is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification       LCO Requirements and Condition                 Condition on Use 3.6.2.C       LCO: [Two] containment air lock[s] shall be       Licensee must justify OPERABLE. Condition: One or more                   that an inoperable containment air locks inoperable for reasons other containment air lock is than an inoperable door or inoperable interlock   not a condition in mechanism.                                        which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
3.7.4.B LOC: [Three] Atmospheric Dump Valves (ADV) lines shall be OPERABLE.
3.6.6A       LCO: Containment Spray and Cooling Systems         Licensee must justify (Atmospheric and Dual) (Credit taken for iodine   the ability to calculate a removal by the Containment Spray System)           RICT for the condition, Condition A: One containment spray train           including how the inoperable.                                       system is modeled in Condition C: One containment cooling train         the PRA, whether all inoperable.                                       functions of the system Condition D: One containment spray and one         are modeled, and, if a containment cooling train inoperable.              surrogate is used, why Condition E: Two containment cooling trains        that modeling is inoperable.                                        conservative.
Condition: Two or more required ADV lines inoperable Licensee must justify that two or more inoperable ADVs is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
Page 26
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Page 25 Specification LCO Requirements and Condition Condition on Use 3.3.6.C (analog)
 
LCO: [Four] channels of Loss of Voltage Function and [four] channels of Degraded Voltage Function auto-initiation instrumentation per DG shall be OPERABLE.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Specification         LCO Requirements and Condition             Condition on Use 3.6.6B       LCO: Containment Spray and Cooling Systems       Licensee must justify (Atmospheric and Dual) (Credit not taken for     the ability to calculate a iodine removal by the Containment Spray System) RICT for the condition, Condition A: One containment spray train         including how the inoperable.                                     system is modeled in Condition B: One containment cooling train       the PRA, whether all inoperable.                                     functions of the system Condition C: Two containment spray trains       are modeled, and, if a inoperable.                                     surrogate is used, why Condition D: One containment spray train and one that modeling is containment cooling train inoperable.            conservative.
Condition: One or more Functions with more than two channels inoperable.
Licensee must justify that more than two channels per bus inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
3.4.9.B LCO: The pressurizer shall be OPERABLE Condition: One [required] group of pressurizer heaters inoperable.
Pressurizer is typically not modeled in the PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.5.2.D LCO: Two ECCS trains shall be OPERABLE.
Condition: Less than 100% of the ECCS flow equivalent to a single OPERABLE train available.
Licensee must justify that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Page 26 Specification LCO Requirements and Condition Condition on Use 3.6.2.C LCO: [Two] containment air lock[s] shall be OPERABLE. Condition: One or more containment air locks inoperable for reasons other than an inoperable door or inoperable interlock mechanism.
Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.
3.6.6A LCO: Containment Spray and Cooling Systems (Atmospheric and Dual) (Credit taken for iodine removal by the Containment Spray System)
Condition A: One containment spray train inoperable.
Condition C: One containment cooling train inoperable.
Condition D: One containment spray and one containment cooling train inoperable.
Condition E: Two containment cooling trains inoperable.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Page 27 Specification LCO Requirements and Condition Condition on Use 3.6.6B LCO: Containment Spray and Cooling Systems (Atmospheric and Dual) (Credit not taken for iodine removal by the Containment Spray System)
Condition A: One containment spray train inoperable.
Condition B: One containment cooling train inoperable.
Condition C: Two containment spray trains inoperable.
Condition D: One containment spray train and one containment cooling train inoperable.
Condition E: Two containment cooling trains inoperable.
Condition E: Two containment cooling trains inoperable.
Page 27
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification        LCO Requirements and Condition                Condition on Use 3.3.1.2.A    LCO: The SRM instrumentation in Table 3.3.1.2-1    Licensee must justify shall be OPERABLE.                                  that one or more Condition: One or more required SRMs                inoperable SRMs is not inoperable in MODE 2 with intermediate range        a condition in which all monitors (IRMs) on Range 2 or below                required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.3.2.2.B     LCO: [Three] channels of feedwater and main         Licensee must justify turbine high water level trip instrumentation shall that two or more be OPERABLE.                                       inoperable trip Condition: Two or more feedwater and main           channels is not a turbine high water level trip channels inoperable. condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Page 28 Specification LCO Requirements and Condition Condition on Use 3.3.1.2.A LCO: The SRM instrumentation in Table 3.3.1.2-1 shall be OPERABLE.
Page 28
Condition: One or more required SRMs inoperable in MODE 2 with intermediate range monitors (IRMs) on Range 2 or below Licensee must justify that one or more inoperable SRMs is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
 
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification       LCO Requirements and Condition             Condition on Use 3.3.4.1.A     LCO: End of Cycle Recirculation Pump Trip     Licensee must justify (EOC-RPT) Instrumentation                     that one or more Condition: One or more required channels       inoperable EOC-RPT inoperable.                                    channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.3.2.2.B LCO: [Three] channels of feedwater and main turbine high water level trip instrumentation shall be OPERABLE.
Condition: Two or more feedwater and main turbine high water level trip channels inoperable.
Licensee must justify that two or more inoperable trip channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Page 29 Specification LCO Requirements and Condition Condition on Use 3.3.4.1.A LCO: End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Condition: One or more required channels inoperable.
Licensee must justify that one or more inoperable EOC-RPT channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
Licensee must justify the ability to calculate a RICT given that EOC-RPT channels are not typically modeled in the PRA.
Licensee must justify the ability to calculate a RICT given that EOC-RPT channels are not typically modeled in the PRA.
3.3.6.3.A     LCO: Low-Low Set (LLS) Instrumentation         Licensee must justify Condition: One LLS valve inoperable due to     the ability to calculate a inoperable channel(s).                         RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.3.6.3.A LCO: Low-Low Set (LLS) Instrumentation Condition: One LLS valve inoperable due to inoperable channel(s).
Page 29
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
 
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Page 30 Specification LCO Requirements and Condition Condition on Use 3.3.8.1.A LCO: The LOP instrumentation for each Function in Table 3.3.8.1-1 shall be OPERABLE.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification         LCO Requirements and Condition               Condition on Use 3.3.8.1.A     LCO: The LOP instrumentation for each Function     Licensee must justify in Table 3.3.8.1-1 shall be OPERABLE.             that one or more Condition: One or more channels inoperable.       channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Condition: One or more channels inoperable.
3.6.1.2.C     LCO: The primary containment air lock shall be     Licensee must justify OPERABLE. Condition: Primary containment air that an inoperable lock inoperable for reasons other than Condition A containment air lock is or B.                                              not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.
Licensee must justify that one or more channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
Page 30
3.6.1.2.C LCO: The primary containment air lock shall be OPERABLE. Condition: Primary containment air lock inoperable for reasons other than Condition A or B.
 
Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Specification         LCO Requirements and Condition             Condition on Use 3.6.1.3.E     LCO: Each PCIV, except reactor building-to-     Licensee must justify suppression chamber vacuum breakers, shall be   that PCIV leakage in OPERABLE.                                       excess of the limits is Condition: One or more penetration flow paths   not a condition in with one or more containment purge valves not   which all required within purge valve leakage limits.               trains or subsystems of a TS required system are inoperable.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Page 31 Specification LCO Requirements and Condition Condition on Use 3.6.1.3.E LCO: Each PCIV, except reactor building-to-suppression chamber vacuum breakers, shall be OPERABLE.
Condition: One or more penetration flow paths with one or more containment purge valves not within purge valve leakage limits.
Licensee must justify that PCIV leakage in excess of the limits is not a condition in which all required trains or subsystems of a TS required system are inoperable.
Licensee must justify the ability to calculate a RICT for this inoperability.
Licensee must justify the ability to calculate a RICT for this inoperability.
3.6.1.7.D     LCO: Each reactor building-to-suppression       Licensee must justify chamber vacuum breaker shall be OPERABLE.       that one or more Condition: Two or more lines with one or more   inoperable vacuum reactor building -to-suppression chamber vacuum breakers on two or breakers inoperable for opening.                 more lines is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.6.1.7.D LCO: Each reactor building-to-suppression chamber vacuum breaker shall be OPERABLE.
3.7.7.A       LCO: The Main Turbine Bypass System shall be     Licensee must justify OPERABLE.                                       the ability to calculate a OR                                               RICT for the condition, The following limits are made applicable:       including how the
Condition: Two or more lines with one or more reactor building -to-suppression chamber vacuum breakers inoperable for opening.
[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR           system is modeled in HEAT GENERATION RATE (APLHGR)," limits           the PRA, whether all for an inoperable Main Turbine Bypass System, as functions of the system specified in the [COLR]; and ]                   are modeled, and, if a
Licensee must justify that one or more inoperable vacuum breakers on two or more lines is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER         surrogate is used, why RATIO (MCPR)," limits for an inoperable Main     that modeling is Turbine Bypass System, as specified in the       conservative.
3.7.7.A LCO: The Main Turbine Bypass System shall be OPERABLE.
OR The following limits are made applicable:
[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the [COLR]; and ]
[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for an inoperable Main Turbine Bypass System, as specified in the
[COLR]. ]
[COLR]. ]
Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].
Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].
Page 31
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
 
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 32 Specification LCO Requirements and Condition Condition on Use 3.3.1.2.A LCO: The SRM instrumentation in Table 3.3.1.2-1 shall be OPERABLE.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification         LCO Requirements and Condition             Condition on Use 3.3.1.2.A     LCO: The SRM instrumentation in Table 3.3.1.2-1 Licensee must justify shall be OPERABLE.                             that one or more Condition: One or more required SRMs           inoperable SRMs is not inoperable in MODE 2 with intermediate range   a condition in which all monitors (IRMs) on Range 2 or below.           required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Condition: One or more required SRMs inoperable in MODE 2 with intermediate range monitors (IRMs) on Range 2 or below.
Licensee must justify that one or more inoperable SRMs is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
Licensee must justify the ability to calculate a RICT given that SRMs are not typically modeled in the PRA.
Licensee must justify the ability to calculate a RICT given that SRMs are not typically modeled in the PRA.
Page 32
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 33 Specification LCO Requirements and Condition Condition on Use 3.3.4.1.A LCO: End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Condition: One or more required channels inoperable.
 
Licensee must justify that one or more inoperable channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification       LCO Requirements and Condition             Condition on Use 3.3.4.1.A     LCO: End of Cycle Recirculation Pump Trip       Licensee must justify (EOC-RPT) Instrumentation                       that one or more Condition: One or more required channels       inoperable channels is inoperable.                                    not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.3.6.5.A LCO: Relief and Low-Low Set (LLS)
Instrumentation Condition: One trip system inoperable.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 34 Specification LCO Requirements and Condition Condition on Use 3.3.8.1.A LCO: The LOP instrumentation for each Function in Table 3.3.8.1-1 shall be OPERABLE.
Condition: One or more channels inoperable.
Licensee must justify that one or more channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.
3.6.1.2.C LCO: The primary containment air lock shall be OPERABLE. Condition: Primary containment air lock inoperable for reasons other than Condition A or B.
Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 35 Specification LCO Requirements and Condition Condition on Use 3.6.1.3.E LCO: Each PCIV shall be OPERABLE.
Condition: One or more penetration flow paths with one or more containment purge valves not within purge valve leakage limits.
Licensee must justify that PCIV leakage in excess of the limits is not a condition in which all required trains or subsystems of a TS required system are inoperable.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.6.1.7.A LCO: Residual Heat Removal (RHR) Containment Spray System Condition: One RHR containment spray subsystem inoperable.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.3.6.5.A    LCO: Relief and Low-Low Set (LLS)              Licensee must justify Instrumentation                                the ability to calculate a Condition: One trip system inoperable.          RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.7.4.A LCO: Two [control room AC] subsystems shall be OPERABLE.
Page 33
Condition: One [control room AC] subsystem inoperable.
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification        LCO Requirements and Condition                Condition on Use 3.3.8.1.A     LCO: The LOP instrumentation for each Function    Licensee must justify in Table 3.3.8.1-1 shall be OPERABLE.              that one or more Condition: One or more channels inoperable.        channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of Attachment 2.
3.6.1.2.C    LCO: The primary containment air lock shall be     Licensee must justify OPERABLE. Condition: Primary containment air that an inoperable lock inoperable for reasons other than Condition A containment air lock is or B.                                              not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.
Page 34
 
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification        LCO Requirements and Condition            Condition on Use 3.6.1.3.E    LCO: Each PCIV shall be OPERABLE.              Licensee must justify Condition: One or more penetration flow paths  that PCIV leakage in with one or more containment purge valves not  excess of the limits is within purge valve leakage limits.            not a condition in which all required trains or subsystems of a TS required system are inoperable.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
3.6.1.7.A    LCO: Residual Heat Removal (RHR) Containment  Licensee must justify Spray System                                  the ability to calculate a Condition: One RHR containment spray          RICT for the condition, subsystem inoperable.                          including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 36 Specification LCO Requirements and Condition Condition on Use 3.7.6.A LCO: The Main Turbine Bypass System shall be OPERABLE.
3.7.4.A      LCO: Two [control room AC] subsystems shall be Licensee must justify OPERABLE.                                      the ability to calculate a Condition: One [control room AC] subsystem    RICT for the condition, inoperable.                                    including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
OR The following limits are made applicable:
Page 35
[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the [COLR] and ]
 
[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for an inoperable Main Turbine Bypass System, as specified in the
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Specification         LCO Requirements and Condition             Condition on Use 3.7.6.A       LCO: The Main Turbine Bypass System shall be     Licensee must justify OPERABLE.                                       the ability to calculate a OR                                               RICT for the condition, The following limits are made applicable:       including how the
[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR           system is modeled in HEAT GENERATION RATE (APLHGR)," limits           the PRA, whether all for an inoperable Main Turbine Bypass System, as functions of the system specified in the [COLR] and ]                   are modeled, and, if a
[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER         surrogate is used, why RATIO (MCPR)," limits for an inoperable Main     that modeling is Turbine Bypass System, as specified in the       conservative.
[COLR]. ]
[COLR]. ]
Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].
Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].
Page 36
Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.
 
Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Page 37 Note 1 Some Conditions are applicable when an unspecified number of subsystems or instrument channels are inoperable, typically written as "One or more" or "Two or more". These conditions currently apply when all subsystems or channels required to be operable to perform a function are inoperable, and application of a RICT in this situation is prohibited in the near-term TSTF-505 submittals.
Attachment 2 Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Note 1 Some Conditions are applicable when an unspecified number of subsystems or instrument channels are inoperable, typically written as "One or more" or "Two or more". These conditions currently apply when all subsystems or channels required to be operable to perform a function are inoperable, and application of a RICT in this situation is prohibited in the near-term TSTF-505 submittals.
To address this, it is recommended that the following modification to TSTF-505 be made to the Required Actions indicated in the Attachment 2 tables for Completion Times potentially applicable when all required subsystems or channels are inoperable.
To address this, it is recommended that the following modification to TSTF-505 be made to the Required Actions indicated in the Attachment 2 tables for Completion Times potentially applicable when all required subsystems or channels are inoperable.
The typical Completion Time is modified by TSTF-505 to state:
The typical Completion Time is modified by TSTF-505 to state:
Line 374: Line 437:
OR In accordance with the Risk Informed Completion Time Program It is recommended that the second Completion Time be modified with a Note, as shown below:
OR In accordance with the Risk Informed Completion Time Program It is recommended that the second Completion Time be modified with a Note, as shown below:
72 hours (i.e., the existing Completion Time)
72 hours (i.e., the existing Completion Time)
OR
OR  
        -------------NOTE-------------
-------------NOTE-------------
Not applicable when
Not applicable when
[all/four/both] required channels are inoperable.
[all/four/both] required channels are inoperable.
        ---------------------------------
In accordance with the Risk Informed Completion Time Program The bracketed number of channels will depend on the specification. This approach retains the existing requirements and limits the use of a RICT to conditions in which the function can still be performed.
In accordance with the Risk Informed Completion Time Program The bracketed number of channels will depend on the specification. This approach retains the existing requirements and limits the use of a RICT to conditions in which the function can still be performed.
The licensee must justify that the required function can still be performed absent an additional failure when a RICT is applied.
The licensee must justify that the required function can still be performed absent an additional failure when a RICT is applied.
Alternatively, the licensee may modify the Condition to only apply when at least one subsystem or channel is operable, but this approach may require creating a new Condition or modifying an existing condition to retain the current requirements, or accepting a more restrictive requirement (such a LCO 3.0.3 entry).
Alternatively, the licensee may modify the Condition to only apply when at least one subsystem or channel is operable, but this approach may require creating a new Condition or modifying an existing condition to retain the current requirements, or accepting a more restrictive requirement (such a LCO 3.0.3 entry).  
Page 37


Attachment 3 TSTF-505 Model Application
TSTF-505 Model Application  


PROPOSED MODEL APPLICATION FOR PLANT-SPECIFIC ADOPTION OF TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B" U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555
Page PROPOSED MODEL APPLICATION FOR PLANT-SPECIFIC ADOPTION OF TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B" U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555  


==SUBJECT:==
==SUBJECT:==
[PLANT]
[PLANT]
DOCKET NO. 50-[XXX]
DOCKET NO. 50-[XXX]
LICENSE AMENDMENT REQUEST TO REVISE TECHNICAL SPECIFICATIONS TO ADOPT RISK INFORMED COMPLETION TIMES TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B."
LICENSE AMENDMENT REQUEST TO REVISE TECHNICAL SPECIFICATIONS TO ADOPT RISK INFORMED COMPLETION TIMES TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B."  


==REFERENCE:==
==REFERENCE:==
Line 400: Line 461:
* Attachment 3 provides revised (clean) TS pages.
* Attachment 3 provides revised (clean) TS pages.
* Attachment 4 provides existing TS Bases pages marked up to show the proposed changes.
* Attachment 4 provides existing TS Bases pages marked up to show the proposed changes.
[LICENSEE] requests approval of the proposed license amendment by [DATE], with the amendment being implemented [BY DATE OR WITHIN X DAYS].
[LICENSEE] requests approval of the proposed license amendment by [DATE], with the amendment being implemented [BY DATE OR WITHIN X DAYS].  
 
Page In accordance with 10 CFR 50.91(a)(1), "Notice for Public Comment," the analysis about the issue of no significant hazards consideration using the standards in 10 CFR 50.92 is being provided to the Commission.
Page In accordance with 10 CFR 50.91(a)(1), "Notice for Public Comment," the analysis about the issue of no significant hazards consideration using the standards in 10 CFR 50.92 is being provided to the Commission.
In accordance with 10 CFR 50.91(b)(1), "Notice for Public Comment; State Consultation," a copy of this application, with attachments, is being provided to the designated [STATE] Official.
In accordance with 10 CFR 50.91(b)(1), "Notice for Public Comment; State Consultation," a copy of this application, with attachments, is being provided to the designated [STATE] Official.
Line 411: Line 473:
: 2. Proposed Technical Specification Changes (Mark-Up)
: 2. Proposed Technical Specification Changes (Mark-Up)
: 3. Revised Technical Specification Pages
: 3. Revised Technical Specification Pages
: 4. Proposed Technical Specification Bases Changes (Mark-Up)
: 4. Proposed Technical Specification Bases Changes (Mark-Up)  


==Enclosures:==
==Enclosures:==
Line 425: Line 487:
: 10. Program Implementation
: 10. Program Implementation
: 11. Monitoring Program
: 11. Monitoring Program
: 12. Risk Management Action Examples cc:     NRC Project Manager NRC Regional Office NRC Resident Inspector State Contact Page ATTACHMENT 1 DESCRIPTION AND ASSESSMENT OF THE PROPOSED CHANGE License Amendment Request for Adoption of TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b"
: 12. Risk Management Action Examples cc:
NRC Project Manager NRC Regional Office NRC Resident Inspector State Contact  


==1.0    DESCRIPTION==
ATTACHMENT 1 DESCRIPTION AND ASSESSMENT OF THE PROPOSED CHANGE License Amendment Request for Adoption of TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b"


==1.0 DESCRIPTION==
The proposed amendment would modify the Technical Specification (TS) requirements related to Completion Times (CTs) for Required Actions to provide the option to calculate a longer, risk-informed CT (RICT). A new program, the Risk-Informed Completion Time Program, is added to TS Section 5 Administrative Controls.
The proposed amendment would modify the Technical Specification (TS) requirements related to Completion Times (CTs) for Required Actions to provide the option to calculate a longer, risk-informed CT (RICT). A new program, the Risk-Informed Completion Time Program, is added to TS Section 5 Administrative Controls.
The methodology for using the RICT Program is described in NEI 06-09-A, "Risk-Informed Technical Specifications Initiative 4b, Risk-Managed Technical Specifications (RMTS)
The methodology for using the RICT Program is described in NEI 06-09-A, "Risk-Informed Technical Specifications Initiative 4b, Risk-Managed Technical Specifications (RMTS)
Guidelines," Revision 0, which was approved by the NRC on May 17, 2007. Adherence to NEI 06-09-A is required by the RICT Program.
Guidelines," Revision 0, which was approved by the NRC on May 17, 2007. Adherence to NEI 06-09-A is required by the RICT Program.
The proposed amendment is consistent with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b," as modified by the TSTF's [DATE] letter to the NRC, "Response to NRC Questions on TSTF-505, 'Provide Risk-Informed Extended Completion Times'." However, only those Required Actions described in Enclosure 1 are proposed to be changed, [which does not include all of the modified Required Actions in TSTF-505 and which includes some plant-specific Required Actions not included in TSTF-505].
The proposed amendment is consistent with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b," as modified by the TSTF's [DATE] letter to the NRC, "Response to NRC Questions on TSTF-505, 'Provide Risk-Informed Extended Completion Times'." However, only those Required Actions described in Enclosure 1 are proposed to be changed, [which does not include all of the modified Required Actions in TSTF-505 and which includes some plant-specific Required Actions not included in TSTF-505].  
2.0     ASSESSMENT 2.1     Applicability of Published Safety Evaluation
 
==2.0 ASSESSMENT==
2.1 Applicability of Published Safety Evaluation
[LICENSEE] has reviewed the model safety evaluation dated [DATE] as part of the Federal Register Notice for Comment. This review included a review of the NRC staffs evaluation, as well as the supporting information provided to support TSTF-505 and the safety evaluation for NEI 06-09, as well as the TSTF's [DATE] letter on TSTF-505. [As described in the subsequent paragraphs,][LICENSEE] has concluded that the technical basis presented in the TSTF-505 proposal, the associated model safety evaluation prepared by the NRC staff, as modified by the TSTF letter on TSTF-505 are applicable to [PLANT, UNIT NOS.] and support incorporation of this amendment in the [PLANT] TS. ]
[LICENSEE] has reviewed the model safety evaluation dated [DATE] as part of the Federal Register Notice for Comment. This review included a review of the NRC staffs evaluation, as well as the supporting information provided to support TSTF-505 and the safety evaluation for NEI 06-09, as well as the TSTF's [DATE] letter on TSTF-505. [As described in the subsequent paragraphs,][LICENSEE] has concluded that the technical basis presented in the TSTF-505 proposal, the associated model safety evaluation prepared by the NRC staff, as modified by the TSTF letter on TSTF-505 are applicable to [PLANT, UNIT NOS.] and support incorporation of this amendment in the [PLANT] TS. ]
2.2     Verifications and Regulatory Commitments In accordance with Section 4.0, Limitations and Conditions, of the safety evaluation for NEI 06-09-A, the following is provided:
2.2 Verifications and Regulatory Commitments In accordance with Section 4.0, Limitations and Conditions, of the safety evaluation for NEI 06-09-A, the following is provided:  
 
Page
: 1. Enclosure 1 identifies each of the TS Required Actions to which the RICT Program will apply, with a comparison of the TS functions to the functions modeled in the probabilistic risk assessment (PRA) of the structures, systems and components (SSCs) subject to those actions.
: 1. Enclosure 1 identifies each of the TS Required Actions to which the RICT Program will apply, with a comparison of the TS functions to the functions modeled in the probabilistic risk assessment (PRA) of the structures, systems and components (SSCs) subject to those actions.
: 2. Enclosure 2 provides a discussion of the results of peer reviews and self-assessments conducted for the plant-specific PRA models which support the RICT Program, as required by Regulatory Guide (RG) 1.200 Section 4.2.
: 2. Enclosure 2 provides a discussion of the results of peer reviews and self-assessments conducted for the plant-specific PRA models which support the RICT Program, as required by Regulatory Guide (RG) 1.200 Section 4.2.
Line 447: Line 515:
: 8. Enclosure 8 provides a description of how the baseline PRA model, which calculates average annual risk, is evaluated and modified for use in the Configuration Risk Management Program (CRMP) to assess real-time configuration risk, and describes the scope of, and quality controls applied to, the CRMP
: 8. Enclosure 8 provides a description of how the baseline PRA model, which calculates average annual risk, is evaluated and modified for use in the Configuration Risk Management Program (CRMP) to assess real-time configuration risk, and describes the scope of, and quality controls applied to, the CRMP
: 9. Enclosure 9 provides a discussion of how the key assumptions and sources of uncertainty in the PRA models were identified, and how their impact on the RICT Program was assessed and dispositioned.
: 9. Enclosure 9 provides a discussion of how the key assumptions and sources of uncertainty in the PRA models were identified, and how their impact on the RICT Program was assessed and dispositioned.
: 10. Enclosure 10 provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation, including risk management action (RMA) implementation.
: 10. Enclosure 10 provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation, including risk management action (RMA) implementation.  
 
Page
Page
: 11. Enclosure 11 provides a description of the implementation and monitoring program as described in NEI 06-09, Section 2.3.2, Step 7.
: 11. Enclosure 11 provides a description of the implementation and monitoring program as described in NEI 06-09, Section 2.3.2, Step 7.
: 12. Enclosure 12 provides a description of the process to identify and provide RMAs.
: 12. Enclosure 12 provides a description of the process to identify and provide RMAs.
2.3     Optional Changes and Variations
2.3 Optional Changes and Variations
[LICENSEE is not proposing any changes, variations, or deviations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE], except as described in the TSTF letter dated [DATE].] [LICENSEE is proposing the following changes or variations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE].
[LICENSEE is not proposing any changes, variations, or deviations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE], except as described in the TSTF letter dated [DATE].] [LICENSEE is proposing the following changes or variations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE].
These options were recognized as acceptable changes or variations in TSTF-505 and the NRC staff's model safety evaluation.]
These options were recognized as acceptable changes or variations in TSTF-505 and the NRC staff's model safety evaluation.]
{NOTE: If a change or variation is not identified in TSTF-505, the NRC staff's model safety evaluation, or NEI 06-09 then provide the description and justification.}
{NOTE: If a change or variation is not identified in TSTF-505, the NRC staff's model safety evaluation, or NEI 06-09 then provide the description and justification.}
[The [PLANT] TS utilize different [numbering][and][titles] than the Standard Technical Specifications on which TSTF-505 was based. Specifically, [describe differences between the plant-specific TS numbering and/or titles (including Required Actions and programs) and the TSTF-505 numbering and titles.] These differences are administrative and do not affect the applicability of TSTF-505 to the [PLANT] TS.]
[The [PLANT] TS utilize different [numbering][and][titles] than the Standard Technical Specifications on which TSTF-505 was based. Specifically, [describe differences between the plant-specific TS numbering and/or titles (including Required Actions and programs) and the TSTF-505 numbering and titles.] These differences are administrative and do not affect the applicability of TSTF-505 to the [PLANT] TS.]
3.0     REGULATORY SAFETY ANALYSIS 3.1     No Significant Hazards Consideration Determination
3.0 REGULATORY SAFETY ANALYSIS 3.1 No Significant Hazards Consideration Determination
[LICENSEE] has evaluated the proposed change to the TS using the criteria in 10 CFR 50.92 and has determined that the proposed change does not involve a significant hazards consideration.
[LICENSEE] has evaluated the proposed change to the TS using the criteria in 10 CFR 50.92 and has determined that the proposed change does not involve a significant hazards consideration.
[PLANT, UNIT NOS.] requests adoption of an approved change to the standard technical specifications (STS) and plant-specific technical specifications (TS), to modify the TS requirements related to Completion Times for Required Actions to provide the option to calculate a longer, risk-informed Completion Time. The allowance is described in a new program in Chapter 5, "Administrative Controls," entitled the "Risk-Informed Completion Time Program."
[PLANT, UNIT NOS.] requests adoption of an approved change to the standard technical specifications (STS) and plant-specific technical specifications (TS), to modify the TS requirements related to Completion Times for Required Actions to provide the option to calculate a longer, risk-informed Completion Time. The allowance is described in a new program in Chapter 5, "Administrative Controls," entitled the "Risk-Informed Completion Time Program."
As required by 10 CFR 50.91(a), an analysis of the issue of no significant hazards consideration is presented below:
As required by 10 CFR 50.91(a), an analysis of the issue of no significant hazards consideration is presented below:
: 1.       Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?
: 1.
Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?  
 
Page Response: No.
Page Response: No.
The proposed change permits the extension of Completion Times provided the associated risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change does not involve a significant increase in the probability of an accident previously evaluated because the change involves no change to the plant or its modes of operation. The proposed change does not increase the consequences of an accident because the design-basis mitigation function of the affected systems is not changed and the consequences of an accident during the extended Completion Time are no different from those during the existing Completion Time.
The proposed change permits the extension of Completion Times provided the associated risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change does not involve a significant increase in the probability of an accident previously evaluated because the change involves no change to the plant or its modes of operation. The proposed change does not increase the consequences of an accident because the design-basis mitigation function of the affected systems is not changed and the consequences of an accident during the extended Completion Time are no different from those during the existing Completion Time.
Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
: 2. Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?
: 2.
Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?
Response: No.
Response: No.
The proposed change does not change the design, configuration, or method of operation of the plant. The proposed change does not involve a physical alteration of the plant (no new or different kind of equipment will be installed).
The proposed change does not change the design, configuration, or method of operation of the plant. The proposed change does not involve a physical alteration of the plant (no new or different kind of equipment will be installed).
Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.
Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.
: 3. Does the proposed change involve a significant reduction in a margin of safety?
: 3.
Does the proposed change involve a significant reduction in a margin of safety?
Response: No.
Response: No.
The proposed change permit the extension of Completion Times provided risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change implements a risk-informed configuration management program to assure that adequate margins of safety are maintained. Application of these new specifications and the configuration management program considers cumulative effects of multiple systems or components being out of service and does so more effectively than the current TS.
The proposed change permit the extension of Completion Times provided risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change implements a risk-informed configuration management program to assure that adequate margins of safety are maintained. Application of these new specifications and the configuration management program considers cumulative effects of multiple systems or components being out of service and does so more effectively than the current TS.
Therefore, the proposed change does not involve a significant reduction in a margin of safety.
Therefore, the proposed change does not involve a significant reduction in a margin of safety.  
Page Based on the above, [LICENSEE] concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.


==4.0    ENVIRONMENTAL CONSIDERATION==
Page Based on the above, [LICENSEE] concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.  


==4.0 ENVIRONMENTAL CONSIDERATION==
[LICENSEE] has reviewed the environmental evaluation included in the model safety evaluation published on [DATE] ([ ] FR [ ]) as part of the Notice of Availability. [LICENSEE] has concluded that the NRC staff findings presented in that evaluation are applicable to [PLANT, NO.].
[LICENSEE] has reviewed the environmental evaluation included in the model safety evaluation published on [DATE] ([ ] FR [ ]) as part of the Notice of Availability. [LICENSEE] has concluded that the NRC staff findings presented in that evaluation are applicable to [PLANT, NO.].
The proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed change meet the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).
The proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed change meet the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).
Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.
Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.  
Page ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGES (MARK-UP)
 
ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGES (MARK-UP)
{provided by the licensee}
{provided by the licensee}


Line 486: Line 560:


ATTACHMENT 4 PROPOSED CHANGES TO TECHNICAL SPECIFICATION BASES CHANGES (MARK-UP) PAGES
ATTACHMENT 4 PROPOSED CHANGES TO TECHNICAL SPECIFICATION BASES CHANGES (MARK-UP) PAGES
{provided by the licensee}
{provided by the licensee}  


ENCLOSURE 1 LIST OF REVISED REQUIRED ACTIONS TO CORRESPONDING PRA FUNCTIONS
ENCLOSURE 1 LIST OF REVISED REQUIRED ACTIONS TO CORRESPONDING PRA FUNCTIONS
Line 492: Line 566:
TS conditions with insufficient TS operable equipment to meet the specified safety function of the system, are not to be included in the application.
TS conditions with insufficient TS operable equipment to meet the specified safety function of the system, are not to be included in the application.
List each TS Required Action to which the RICT Program may be applied and, for each Required Action, describe the following:
List each TS Required Action to which the RICT Program may be applied and, for each Required Action, describe the following:
* The TS Required Action;
The TS Required Action; The corresponding SSC; Each design basis function of the SSC; How each design basis function is modeled in the PRA. If one of the design basis functions of an SSC or the SSC is not modeled in the PRA, describe any proposed surrogates and why the proposed surrogate adequately captures the configuration risk; and The success criteria used in the PRA model compared to the licensing basis criteria. The success criteria should include both train-level and component/parameter level.
* The corresponding SSC;
* Each design basis function of the SSC;
* How each design basis function is modeled in the PRA. If one of the design basis functions of an SSC or the SSC is not modeled in the PRA, describe any proposed surrogates and why the proposed surrogate adequately captures the configuration risk; and
* The success criteria used in the PRA model compared to the licensing basis criteria. The success criteria should include both train-level and component/parameter level.
Note that the above description should be at the level of the TS condition/TS Required Action (not at the LCO level only). If the TS condition/ TS Required action covers multiple SSCs or multiple design basis functions, such as in the case ESFAS Instrumentation or Containment Sprays, describe each one individually.
Note that the above description should be at the level of the TS condition/TS Required Action (not at the LCO level only). If the TS condition/ TS Required action covers multiple SSCs or multiple design basis functions, such as in the case ESFAS Instrumentation or Containment Sprays, describe each one individually.
The enclosure should also include clear definitions of any used terms, such as train, division, loop, "subsystem," etc.
The enclosure should also include clear definitions of any used terms, such as train, division, loop, "subsystem," etc.
The enclosure should provide a detailed system description of TS 3.8, "Electrical Power Systems," Required Actions if the loading scheme is not uniform (e.g., Train A and B have similar loading, except Train B supplies power to additional SSCs.) Also, provide a description in Enclosure 12 of representative RMAs for non-uniform trains to demonstrate that the systems safety function is maintained with either train or subsystem operable.}
The enclosure should provide a detailed system description of TS 3.8, "Electrical Power Systems," Required Actions if the loading scheme is not uniform (e.g., Train A and B have similar loading, except Train B supplies power to additional SSCs.) Also, provide a description in Enclosure 12 of representative RMAs for non-uniform trains to demonstrate that the systems safety function is maintained with either train or subsystem operable.}  


ENCLOSURE 2 INFORMATION SUPPORTING CONSISTENCY WITH REGULATORY GUIDE 1.200, REVISION 2
ENCLOSURE 2 INFORMATION SUPPORTING CONSISTENCY WITH REGULATORY GUIDE 1.200, REVISION 2
Line 505: Line 575:
Per NEI 06-09 Rev. 0, capability category II of the standards is applicable; therefore, the licensee identifies those parts of the PRAs that conform to capability categories lower than II, and provides a disposition for the RICT Program. Consistent with RG 1.200 Section 4.2, the licensee identifies and provides a discussion of the resolution of any findings and observations from the peer reviews or self-assessments.
Per NEI 06-09 Rev. 0, capability category II of the standards is applicable; therefore, the licensee identifies those parts of the PRAs that conform to capability categories lower than II, and provides a disposition for the RICT Program. Consistent with RG 1.200 Section 4.2, the licensee identifies and provides a discussion of the resolution of any findings and observations from the peer reviews or self-assessments.
The licensee assessment must also address the clarifications and qualifications found in RG 1.200, either by a separate discussion provided by the licensee, or by confirmation that the peer reviews or self-assessments included consideration of the clarifications and qualifications of the current applicable RG 1.200 revision.
The licensee assessment must also address the clarifications and qualifications found in RG 1.200, either by a separate discussion provided by the licensee, or by confirmation that the peer reviews or self-assessments included consideration of the clarifications and qualifications of the current applicable RG 1.200 revision.
Licensees are strongly encouraged to apply the guidance in Appendix X, "Close out of Facts and Observations," of NEI 05-04, "Process for Performing Internal Events PRA Peer Reviews Using the ASME/ANS PRA Standard, Rev 3, November 2009," NEI 07-12, "Fire Probabilistic Risk Assessment Peer Review Process Guidelines, Rev 1, June 2010," and NEI 12-13, "External Hazards PRA Peer Review Process Guidelines, Rev 0, August 2012," to close PRA peer review findings, as this will make more efficient use of the NRC and industry resources needed to develop and review of the application. }
Licensees are strongly encouraged to apply the guidance in Appendix X, "Close out of Facts and Observations," of NEI 05-04, "Process for Performing Internal Events PRA Peer Reviews Using the ASME/ANS PRA Standard, Rev 3, November 2009," NEI 07-12, "Fire Probabilistic Risk Assessment Peer Review Process Guidelines, Rev 1, June 2010," and NEI 12-13, "External Hazards PRA Peer Review Process Guidelines, Rev 0, August 2012," to close PRA peer review findings, as this will make more efficient use of the NRC and industry resources needed to develop and review of the application. }  


ENCLOSURE 3 INFORMATION SUPPORTING TECHNICAL ADEQUACY OF PRA MODELS WITHOUT PRA STANDARDS ENDORSED BY REGULATORY GUIDE 1.200, REVISION 2
ENCLOSURE 3 INFORMATION SUPPORTING TECHNICAL ADEQUACY OF PRA MODELS WITHOUT PRA STANDARDS ENDORSED BY REGULATORY GUIDE 1.200, REVISION 2
Line 511: Line 581:
RG 1.200 Rev. 2 endorses standards for internal and external events including internal floods and fires, seismic events, and other external hazards for full power conditions.
RG 1.200 Rev. 2 endorses standards for internal and external events including internal floods and fires, seismic events, and other external hazards for full power conditions.
This scope includes the relevant hazard groups applicable to a RICT Program unless the program is to apply to lower modes of operation. In this case, shutdown and transition risk PRA models may apply but are not be covered by an endorsed standard.
This scope includes the relevant hazard groups applicable to a RICT Program unless the program is to apply to lower modes of operation. In this case, shutdown and transition risk PRA models may apply but are not be covered by an endorsed standard.
If applicable, the licensee should provide a detailed description of these PRA models and the basis for its determination of their technical adequacy to support the RICT Program.}
If applicable, the licensee should provide a detailed description of these PRA models and the basis for its determination of their technical adequacy to support the RICT Program.}  


ENCLOSURE 4 INFORMATION SUPPORTING JUSTIFICATION OF EXCLUDING SOURCES OF RISK NOT ADDRESSED BY THE PRA MODELS
ENCLOSURE 4 INFORMATION SUPPORTING JUSTIFICATION OF EXCLUDING SOURCES OF RISK NOT ADDRESSED BY THE PRA MODELS
Line 519: Line 589:
For external hazards that are not screened out from inclusion in RICT calculations, the licensee may propose a bounding approach to address the hazard. If the bounding approach involves assuming a uniform increase in baseline risk to address the hazard, the licensee will need to address potential RICT-specific impacts by doing one of the following:
For external hazards that are not screened out from inclusion in RICT calculations, the licensee may propose a bounding approach to address the hazard. If the bounding approach involves assuming a uniform increase in baseline risk to address the hazard, the licensee will need to address potential RICT-specific impacts by doing one of the following:
* Demonstrate in the LAR that this approach is bounding for all TS actions included in the LAR, or
* Demonstrate in the LAR that this approach is bounding for all TS actions included in the LAR, or
* Establish a procedure to evaluate the validity of the bounding approach when calculating an RICT that is not demonstrated to be bounded in the LAR, or
* Establish a procedure to evaluate the validity of the bounding approach when calculating an RICT that is not demonstrated to be bounded in the LAR, or For RICTs not demonstrated to be bounded in the LAR, establish a procedure to qualitatively evaluate the impact of the specific external hazard for each RICT when calculated and apply risk management actions as appropriate. }  
* For RICTs not demonstrated to be bounded in the LAR, establish a procedure to qualitatively evaluate the impact of the specific external hazard for each RICT when calculated and apply risk management actions as appropriate. }


ENCLOSURE 5 BASELINE CDF AND LERF
ENCLOSURE 5 BASELINE CDF AND LERF
{NOTE: This enclosure provides the plant-specific total CDF and total LERF to confirm that these are less than 10-4/year and 10-5/year, respectively. This assures that the potential risk increases allowed under the RICT Program are consistent with RG 1.174, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," Revision 2.
{NOTE: This enclosure provides the plant-specific total CDF and total LERF to confirm that these are less than 10-4/year and 10-5/year, respectively. This assures that the potential risk increases allowed under the RICT Program are consistent with RG 1.174, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," Revision 2.
The licensee should provide the totals and the contributions from each hazard group (internal events, fires, floods, seismic, other external). }
The licensee should provide the totals and the contributions from each hazard group (internal events, fires, floods, seismic, other external). }  


ENCLOSURE 6 JUSTIFICATION OF APPLICATION OF AT-POWER PRA MODELS TO SHUTDOWN MODES
ENCLOSURE 6 JUSTIFICATION OF APPLICATION OF AT-POWER PRA MODELS TO SHUTDOWN MODES
Line 530: Line 599:
The at-power PRA models may potentially be applied to lower modes of operation (hot standby for PWRs, and hot shutdown for PWRs and BWRs) for some Required Actions.
The at-power PRA models may potentially be applied to lower modes of operation (hot standby for PWRs, and hot shutdown for PWRs and BWRs) for some Required Actions.
If the licensee is not proposing to use the RICT Program in these modes, then this information is not required and this Enclosure should be marked "Not applicable."
If the licensee is not proposing to use the RICT Program in these modes, then this information is not required and this Enclosure should be marked "Not applicable."
Otherwise, the licensee provides a detailed justification for those Required Actions proposed to apply the RICT Program in lower modes of operation using the at-power PRA models.}
Otherwise, the licensee provides a detailed justification for those Required Actions proposed to apply the RICT Program in lower modes of operation using the at-power PRA models.}  


ENCLOSURE 7 PRA MODEL UPDATE PROCESS
ENCLOSURE 7 PRA MODEL UPDATE PROCESS
{NOTE: This enclosure describes how the PRA models used in the calculation of completion times is maintained consistent with the as-built, as-operated plant.
{NOTE: This enclosure describes how the PRA models used in the calculation of completion times is maintained consistent with the as-built, as-operated plant.
The licensee provides a discussion of its programs and procedures to assure the PRA models that support the RICT Program are maintained consistent with the as-built, as-operated plant. This should include a discussion of the timing of significant PRA model changes as described in NEI 06-09, Section 2.3.4, Step 7.}
The licensee provides a discussion of its programs and procedures to assure the PRA models that support the RICT Program are maintained consistent with the as-built, as-operated plant. This should include a discussion of the timing of significant PRA model changes as described in NEI 06-09, Section 2.3.4, Step 7.}  


ENCLOSURE 8 ATTRIBUTES OF THE CRMP MODEL
ENCLOSURE 8 ATTRIBUTES OF THE CRMP MODEL
Line 544: Line 613:
* The licensee describes how consistency of calculated results from the baseline PRA model and the CRMP are verified to assure the CRMP PRA models are consistent with the baseline model and updated when the baseline PRA model is updated.
* The licensee describes how consistency of calculated results from the baseline PRA model and the CRMP are verified to assure the CRMP PRA models are consistent with the baseline model and updated when the baseline PRA model is updated.
* The licensee describes the quality requirements applied to the CRMP PRA models.
* The licensee describes the quality requirements applied to the CRMP PRA models.
* The licensee describes the training and qualification programs applicable to personnel responsible for development and use of the CRMP.}
* The licensee describes the training and qualification programs applicable to personnel responsible for development and use of the CRMP.}  


ENCLOSURE 9 KEY ASSUMPTIONS AND SOURCES OF UNCERTAINTY
ENCLOSURE 9 KEY ASSUMPTIONS AND SOURCES OF UNCERTAINTY
{NOTE: This enclosure describes the key assumptions and sources of uncertainty in the PRA models, and how their impact on the RICT Program was assessed and dispositioned. Sensitivity analyses for various plant configuration cases under different assumptions should be provided to justify conclusions.}
{NOTE: This enclosure describes the key assumptions and sources of uncertainty in the PRA models, and how their impact on the RICT Program was assessed and dispositioned. Sensitivity analyses for various plant configuration cases under different assumptions should be provided to justify conclusions.}  


ENCLOSURE 10 PROGRAM IMPLEMENTATION
ENCLOSURE 10 PROGRAM IMPLEMENTATION
{NOTE: This enclosure provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation including training of plant personnel, and specifically discusses the decision process for risk management action (RMA) implementation during extended CTs.}
{NOTE: This enclosure provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation including training of plant personnel, and specifically discusses the decision process for risk management action (RMA) implementation during extended CTs.}  


ENCLOSURE 11 MONITORING PROGRAM
ENCLOSURE 11 MONITORING PROGRAM
{NOTE: This enclosure describes the monitoring program for cumulative risk impacts as described in NEI 06-09, Revision 0, Section 2.3.2, Step 7. This should include a description of how the calculations are made and what actions and thresholds are applied when corrective measures are necessary due to excessive risk increases.}
{NOTE: This enclosure describes the monitoring program for cumulative risk impacts as described in NEI 06-09, Revision 0, Section 2.3.2, Step 7. This should include a description of how the calculations are made and what actions and thresholds are applied when corrective measures are necessary due to excessive risk increases.}  


ENCLOSURE 12 RISK MANAGEMENT ACTION EXAMPLES
ENCLOSURE 12 RISK MANAGEMENT ACTION EXAMPLES

Latest revision as of 10:54, 8 January 2025

"Draft Meeting" is not in the list (Request, Draft Request, Supplement, Acceptance Review, Meeting, Withholding Request, Withholding Request Acceptance, RAI, Draft RAI, Draft Response to RAI, ...) of allowed values for the "Project stage" property.

TSTF-505 Near Term Revised Draft - Clean Copy for 09/12/2017 Teleconference
ML17258A127
Person / Time
Site: Technical Specifications Task Force
Issue date: 09/12/2017
From:
Technical Specifications Task Force
To:
Office of Nuclear Reactor Regulation
Honcharik M, 301-415-1774, DSS/STSB
Shared Package
ML17258A124 List:
References
Download: ML17258A127 (62)


Text

11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301-984-4400, Fax: 301-984-7600 Administration by EXCEL Services Corporation TECHNICAL SPECIFICATIONS TASK FORCE A JOINT OWNERS GROUP ACTIVITY TSTF DATE DRAFT TSTF-17-01 REVISION 3 PROJ0753 Attn: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Response to NRC Questions on TSTF-505-A, "Provide Risk-Informed Extended Completion Times"

Reference:

Letter from T. McGinty and A. Boland (NRC) to Technical Specifications Task Force (TSTF), "Issues with Technical Specifications Task Force Traveler TSTF-505, Revision 1, 'Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b'," dated November 15, 2016 In the referenced letter, the NRC raised concerns with approved TSTF traveler, TSTF-505-A, Revision 1, "Provide Risk-Informed Extended Completion Times." The NRC published in the Federal Register a notice of availability for the Model Safety Evaluation (SE) for plant-specific adoption of TSTF traveler TSTF-505, Revision 1, on March 15, 2012. Currently, several licensees have License Amendment Requests (LARs) under NRC review to adopt risk-informed Completion Times.

On December 13, 2016, the TSTF and the Nuclear Energy Institute (NEI) met with the NRC to discuss the NRC's concerns. Most of the NRC concerns were related to proposed Technical Specifications (TS) Actions related to all trains of a TS required system being inoperable. The industry proposed the following short-term and long-term actions to resolve the NRC concerns:

1. The industry will pursue development of a companion traveler for TSTF-505-A that addresses the NRC issues with Actions related to inoperability of all trains of a TS required system. Following approval, plants that have adopted TSTF-505-A without these Actions could submit a LAR to adopt the companion traveler. Following NRC approval of the companion traveler, plants that have not adopted TSTF-505-A can adopt TSTF-505-A and the companion traveler in a single LAR.
2. TSTF-505-A allows licensees to choose which Action changes are included in their LAR.

The TSTF will recommend to the industry that until the companion traveler is approved by the NRC, licensees submitting LARs to adopt TSTF-505 follow the guidance in the attachments to this letter. Actions related to the inoperability of all trains of a TS required system should not be included in LARs submitted prior to approval of the companion traveler. Omitting these Actions and incorporating the other changes recommended in the

TSTF-17-01 DATE attachments to this letter should allow timely approval of LARs. Attachment 1 contains a list of the Actions revised by TSTF-505-A that should be omitted in LARs submitted prior to approval of the companion traveler. Attachment 1 also includes conforming changes to the TSTF-505-A Section 1.3 TS example and the TS Section 5.5 Administrative Controls program. Attachment 2 contains a list of Actions revised by TSTF-505-A that have conditions on their inclusion in a plant-specific LAR. Attachment 3 contains a revised Mode Application for requesting adoption of TSTF-505-A.

3. The proposed actions only apply to future submittals. The licensees with LARs currently under NRC review will decide how to proceed.

The TSTF requests that the NRC rescind the suspension of the approval of TSTF-505-A, Revision 1, and accept LARs to adopt TSTF-505-A that follow the recommendations in the attachments to this letter.

Should you have any questions, please do not hesitate to contact us.

James R. Morris (PWROG/W)

Lisa L. Williams (BWROG)

Otto W. Gustafson (PWROG/CE)

Jordan Vaughan (PWROG/B&W)

Jason P. Redd (APOG)

Enclosure cc:

Mirella Gavrilas, Director of the Division of Safety Systems Anne T. Boland, Director of the Division of Operating Reactor Licensing Jennifer Whitman, Acting Chief of the Technical Specifications Branch Michelle Honcharik, Technical Specifications Branch Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Page 1 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.1.C RPS Instrumentation Do not include Action 3.3.2.A Reactor Protection System (RPS) Manual Reactor Trip Do not include.

Action 3.3.5.B ESFAS Instrumentation Do not include Action 3.3.6.B ESFAS Manual Initiation Do not include Action 3.3.11.D EFIC System Instrumentation Do not include Action 3.3.13.B EFIC Logic Do not include Action 3.3.14.B EFIC-EFW-Vector Valve Logic Do not include Action 3.4.10.A Pressurizer Safety Valves Do not include.

Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.

Action 3.5.1.A CFTs Do not include Action 3.5.1.B CFTs Do not include Action 3.5.1.C CFTs Do not include Action 3.5.2.C ECCS - Operating Do not include Action 3.5.3.B ECCS - Shutdown Do not include.

Action 3.5.4.A BWST Do not include Action 3.5.4.B BWST Do not include Action 3.6.3.B Containment Isolation Valves Do not include Action 3.6.3.D Containment Isolation Valves Do not include Action 3.6.6.F Containment Spray and Cooling Systems Do not include Action 3.7.2.C MSIVs Do not include Action 3.7.4.B AVVs Do not include.

Action 3.7.5.C EFW System Do not include Action 3.7.6.A CST Do not include.

Action 3.7.8.B SWS Do not include Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1430, Babcock and Wilcox STS Page 2 Specification Specification Title Notes Action 3.7.9.C UHS Do not include Action 3.7.11.B CREVS Do not include Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached recommended changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Page 3 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.1.C RTS Instrumentation Do not include Action 3.3.1.E RTS Instrumentation Do not include Action 3.3.1.G RTS Instrumentation Do not include Action 3.3.1.I RTS Instrumentation Do not include Action 3.3.1.Q RTS Instrumentation Do not include Action 3.3.1.S RTS Instrumentation Do not include Action 3.3.1.T RTS Instrumentation Do not include Action 3.3.1.V RTS Instrumentation Do not include Action 3.3.1.W RTS Instrumentation Do not include Action 3.3.1.Z RTS Instrumentation Do not include Action 3.3.1.CC RTS Instrumentation Do not include Action 3.3.1.EE RTS Instrumentation Do not include Action 3.3.1.JJ RTS Instrumentation Do not include Action 3.3.2.C ESFAS Instrumentation Do not include Action 3.3.2.E ESFAS Instrumentation Do not include Action 3.3.2.G ESFAS Instrumentation Do not include Action 3.3.2.I ESFAS Instrumentation Do not include Action 3.3.2.K ESFAS Instrumentation Do not include Action 3.3.2.M ESFAS Instrumentation Do not include Action 3.3.2.O ESFAS Instrumentation Do not include Action 3.3.2.Q ESFAS Instrumentation Do not include Action 3.3.2.S ESFAS Instrumentation Do not include Action 3.3.2.U ESFAS Instrumentation Do not include Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Page 4 Specification Specification Title Notes Action 3.3.2.V ESFAS Instrumentation Do not include. Required Action outside the scope of TSTF-505.

Action 3.3.9.B BDPS Do not include Action 3.4.9.C Pressurizer Do not include.

Action 3.4.10.A Pressurizer Safety Valves Do not include.

Action 3.4.11.E Pressurizer Power Operated Relief Valves (PORVs)

Do not include.

Action 3.4.11.F Pressurizer Power Operated Relief Valves (PORVs)

Do not include.

Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.

Action 3.5.1.A Accumulators Do not include.

Action 3.5.1.B Accumulators Do not include.

Action 3.5.1.C Accumulators Do not include.

Action 3.5.2.B ECCS - Operating Do not include.

Action 3.5.3.B ECCS - Shutdown Do not include.

Action 3.5.4.A RWST Do not include.

Action 3.5.4.B RWST Do not include.

Action 3.5.6.A Boron Injection Tank Do not include.

Action 3.6.3.B Containment Isolation Valves Do not include.

Action 3.6.3.C Containment Isolation Valves Do not include.

Action 3.6.3.D Containment Isolation Valves Do not include.

Action 3.6.3.E Containment Isolation Valves Do not include.

Action 3.6.6A.E Containment Spray and Cooling Systems (Atmospheric and Dual)

Do not include.

Action 3.6.6B.G Containment Spray and Cooling Systems (Atmospheric and Dual)

Do not include.

Action 3.6.6C.B Containment Spray System (Ice Condenser)

Do not include.

Action 3.6.6D.B QS System (Subatmospheric)

Do not include.

Action 3.6.6E.F RS System (Subatmospheric)

Do not include.

Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1431, Westinghouse STS Page 5 Specification Specification Title Notes Action 3.6.9.B Hydrogen Mixing System Do not include.

Action 3.6.10.C HIS (Ice Condenser)

Do not include.

Action 3.6.14.B ARS (Ice Condenser)

Do not include.

Action 3.6.15.A Ice Bed Do not include.

Action 3.6.17.A Divider Barrier Integrity (Ice Condenser)

Do not include.

Action 3.6.17.B Divider Barrier Integrity (Ice Condenser)

Do not include.

Action 3.6.18.A Containment Recirculation Drains (Ice Condenser)

Do not include.

Action 3.6.18.B Containment Recirculation Drains (Ice Condenser)

Do not include.

Action 3.7.2.C MSIVs Do not include.

Action 3.7.5.C AFW System Do not include.

Action 3.7.6.A Condensate Storage Tank Do not include.

Action 3.7.7.B CCW System Do not include.

Action 3.7.8.B SWS Do not include.

Action 3.7.9.C UHS Do not include.

Action 3.7.11.B CREATCS Do not include.

Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached Recommended Changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Page 6 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.3.4.B ESFAS Instrumentation (Analog)

Do not include.

Action 3.3.5.B ESFAS Logic and Manual Trip (Analog)

Do not include.

Action 3.3.5.E ESFAS Logic and Manual Trip (Analog)

Do not include.

Action 3.3.6.A ESFAS Logic and Manual Trip (Digital)

Do not include.

Action 3.3.6.E ESFAS Logic and Manual Trip (Digital)

Do not include.

Action 3.4.9.C Pressurizer Do not include.

Action 3.4.10.A Pressurizer Safety Valves Do not include.

Action 3.4.11.E Pressurizer Power Operated Relief Valves (PORVs)

Do not include.

Action 3.4.11.F Pressurizer Power Operated Relief Valves (PORVs)

Do not include.

Action 3.4.14.C RCS Pressure Isolation Valve (PIV) Leakage Do not include.

Action 3.5.1.A SITs Do not include.

Action 3.5.1.B SITs Do not include.

Action 3.5.1.C SITs Do not include.

Action 3.5.2.C ECCS - Operating Do not include.

Action 3.5.3.A ECCS - Shutdown Do not include.

Action 3.5.4.A RWT Do not include.

Action 3.5.4.B RWT Do not include.

Action 3.6.3.C Containment Isolation Valves Do not include.

Action 3.6.3.E Containment Isolation Valves Do not include.

Action 3.6.3.F Containment Isolation Valves Do not include.

Action 3.6.6A.F Containment Spray and Cooling Systems (Atmospheric and Dual)

Do not include.

Action 3.6.6B.F Containment Spray and Cooling Systems (Atmospheric and Dual)

Do not include.

Action 3.6.9.B Hydrogen Mixing System Do not include.

Action 3.7.2.C MSIVs Do not include.

Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1432, Combustion Engineering STS Page 7 Specification Specification Title Notes Action 3.7.4.B Atmospheric Dump Valves Do not include.

Action 3.7.5.C AFW System Do not include.

Action 3.7.6.A Condensate Storage Tank Do not include.

Action 3.7.7.B CCW System Do not include.

Action 3.7.8.B SWS Do not include.

Action 3.7.9.C UHS Do not include.

Action 3.7.10.B ECW Do not include.

Action 3.7.12.B CREATCS Do not include.

Action 3.8.1.E AC Sources - Operating Do not include.

Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.18 Risk Informed Completion Time Program See attached recommended changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Page 8 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.1.7.A SLC System Do not include.

Action 3.1.7.C SLC System Do not include.

Action 3.3.1.1.C Reactor Protection System (RPS) Instrumentation Do not include.

Action 3.3.4.1.B End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Do not include.

Action 3.3.4.2.B Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT)

Instrumentation Do not include.

Action 3.3.4.2.C Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT)

Do not include.

Action 3.3.5.2.C Reactor Core Isolation Cooling (RCIC) System Instrumentation Do not include.

Action 3.3.6.1.B Primary Containment Isolation Instrumentation Do not include.

Action 3.3.6.3.C LLS Instrumentation Do not include.

Action 3.3.6.3.D LLS Instrumentation Do not include.

Action 3.4.3.B S/RVs Do not include.

Action 3.5.1.G ECCS - Operating Do not include.

Action 3.5.1.I ECCS - Operating Do not include.

Action 3.6.1.3.B PCIVs Do not include. Required Action outside the scope of TSTF-505.

Action 3.6.1.3.C PCIVs Do not include. Required Action outside the scope of TSTF-505.

Action 3.6.2.3.B Residual Heat Removal (RHR) Suppression Pool Cooling Do not include.

Action 3.6.2.4.B Residual Heat Removal (RHR) Suppression Pool Spray Do not include.

Action 3.6.3.3.B Containment Atmosphere Dilution (CAD) System Do not include.

Action 3.7.1.D Residual Heat Removal Service Water (RHRSW)

System Do not include.

Action 3.7.2.F

[PSW] System and [UHS]

Do not include.

Action 3.7.5.B

[Control Room AC] System Do not include.

Action 3.8.1.E AC Sources - Operating Do not include Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1433, BWR/4 STS Page 9 Specification Specification Title Notes Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.15 Risk Informed Completion Time Program See attached recommended changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Page 10 Specification Specification Title Notes 1.3 Completion Times See attached recommended changes Action 3.1.7.A SLC System Do not include.

Action 3.1.7.C SLC System Do not include.

Action 3.3.1.1.C Reactor Protection System (RPS) Instrumentation Do not include.

Action 3.3.4.1.B End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Do not include.

Action 3.3.4.2.B Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT)

Instrumentation Do not include.

Action 3.3.4.2.C Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT)

Instrumentation Do not include.

Action 3.3.5.2.C Reactor Core Isolation Cooling (RCIC) System Instrumentation Do not include.

Action 3.3.6.1.B Primary Containment Isolation Instrumentation Do not include.

Action 3.3.6.4.B Suppression Pool Makeup (SPMU) System Instrumentation Do not include.

Action 3.3.6.4.C Suppression Pool Makeup (SPMU) System Instrumentation Do not include.

Action 3.3.6.5.B Relief and LLS Instrumentation Do not include.

Action 3.4.4.B S/RVs Do not include.

Action 3.5.1.G ECCS - Operating Do not include.

Action 3.5.1.I ECCS - Operating Do not include.

Action 3.5.1.J ECCS - Operating Do not include.

Action 3.5.1.K ECCS - Operating Do not include.

Action 3.5.1.L ECCS - Operating Do not include.

Action 3.6.1.3.B Primary Containment Isolation Valves (PCIVs)

Do not include.

Action 3.6.1.3.C Primary Containment Isolation Valves (PCIVs)

Do not include.

Action 3.6.1.3.D Primary Containment Isolation Valves (PCIVs)

Do not include.

Action 3.6.1.7.B Residual Heat Removal (RHR) Containment Spray System Do not include.

Action 3.6.2.3.B Residual Heat Removal (RHR) Suppression Pool Cooling Do not include.

Action 3.6.2.4.A SPMU System Do not include.

Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests TSTF-505 Markup to NUREG-1434, BWR/6 STS Page 11 Specification Specification Title Notes Action 3.6.2.4.B SPMU System Do not include.

Action 3.6.2.4.D SPMU System Do not include.

Action 3.6.3.1.B Drywell Cooling System Fans Do not include.

Action 3.6.3.2.B Drywell Purge System Do not include.

Action 3.6.5.1.A Drywell Do not include.

Action 3.6.5.3.B Drywell Isolation Valve[s]

Do not include.

Action 3.6.5.6.D Drywell Vacuum Relief System Do not include.

Action 3.6.5.6.E Drywell Vacuum Relief System Do not include.

Action 3.6.5.6.F Drywell Vacuum Relief System Do not include.

Action 3.7.1.D

[SSW] System and [UHS]

Do not include.

Action 3.7.4.B

[Control Room AC] System Do not include.

Action 3.8.1.E AC Sources - Operating Do not include Action 3.8.1.G AC Sources - Operating Do not include Action 3.8.4.A.1 DC Sources - Operating Do not include. Required Action outside the scope of TSTF-505.

Action 3.8.4.D DC Sources - Operating Do not include Action 3.8.7.B Inverters - Operating Do not include Action 3.8.9.D Distribution Systems - Operating Do not include 5.5.15 Risk Informed Completion Time Program See attached recommended changes Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example Page 12


Reviewer's Note ------------------------------------------

Example 1.3-8 is only applicable to plants that have adopted the Risk Informed Completion Time Program.

[

EXAMPLE 1.3-8 ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One subsystem inoperable.

A.1 Restore subsystem to OPERABLE status.

7 days OR In accordance with the Risk Informed Completion Time Program B. --- NOTE ------

Not applicable when second subsystem intentionally made inoperable.

Two subsystems inoperable.

B.1 Restore subsystems to OPERABLE status.

1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> OR In accordance with the Risk Informed Completion Time Program BC.Required Action and associated Completion Time not met.

BC.1 Be in MODE 3.

AND BC.2 Be in MODE 5.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 36 hours Recommended Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Recommended Changes to the Section 1.3 Example Page 13 When a subsystem is declared inoperable, Condition A is entered. The 7 day Completion Time may be applied as discussed in Example 1.3-2. However, the licensee may elect to apply the Risk Informed Completion Time Program which permits calculation of a Risk Informed Completion Time (RICT) that may be used to complete the Required Action beyond the 7 day Completion Time. The RICT cannot exceed 30 days. After the 7 day Completion Time has expired, the subsystem must be restored to OPERABLE status within the RICT or Condition BC must also be entered.

If a second subsystem is declared inoperable, Condition B may also be entered. The Condition is modified by a Note stating it is not applicable if the second subsystem is intentionally made inoperable. The Required Actions of Condition B are not intended for voluntary removal of redundant subsystems from service. The Required Action is only applicable if one subsystem is inoperable for any reason and the second subsystem is found to be inoperable, or if both subsystems are found to be inoperable at the same time. If Condition B is applicable, at least one subsystem must be restored to OPERABLE status within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or Condition C must also be entered. The licensee may be able to apply a RICT to extend the Completion Time beyond 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> if the requirements of the Risk Informed Completion Time Program are met. If two subsystems are inoperable and Condition B is not applicable (i.e., the second subsystem was intentionally made inoperable), LCO 3.0.3 is entered as there is no applicable Condition.

The Risk Informed Completion Time Program requires recalculation of the RICT to reflect changing plant conditions. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after the plant configuration change, whichever is less.

If the 7 day Completion Time clock of Condition A or the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time clock of Condition B have has expired and subsequent changes in plant condition result in exiting the applicability of the Risk Informed Completion Time Program without restoring the inoperable subsystem to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start.

If the RICT expires or is recalculated to be less than the elapsed time since the Condition was entered and the inoperable subsystem has not been restored to OPERABLE status, Condition BC is also entered and the Completion Time clocks for Required Actions BC.1 and BC.2 start. If the inoperable subsystems are restored to OPERABLE status after Condition BC is entered, Conditions A, B, and BC are exited, and therefore, the Required Actions of Condition BC may be terminated. ]

Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program Page 14

[ 5.5.18 Risk Informed Completion Time Program This program provides controls to calculate a Risk Informed Completion Time (RICT) and must be implemented in accordance with NEI 06-09-A, Revision 0, "Risk-Managed Technical Specifications (RMTS) Guidelines." The program shall include the following:

a. The RICT may not exceed 30 days;

REVIEWER'S NOTE ----------------------------------

The Risk Informed Completion Time is only applicable in MODES supported by the Licensees PRA. Licensee's applying the RICT Program to MODES other than Modes 1 and 2 must demonstrate that they have the capability to calculate a RICT in those MODES or that the risk indicated by their MODE 1 and 2 PRA model is bounding with respect to the lower MODE conditions.

b.

A RICT may only be utilized in MODE 1, 2 [, and 3, and MODE 4 while relying on steam generators for heat removal];

c.

When a RICT is being used, any change to the plant configuration, as defined in NEI 06-09-A, Appendix A, change within the scope of the Risk Informed Completion Time Program must be considered for the effect on the RICT.

1. For planned changes, the revised RICT must be determined prior to implementation of the change in configuration.
2. For emergent conditions, the revised RICT must be determined within the time limits of the Required Action Completion Time (i.e., not the RICT) or 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after the plant configuration change, whichever is less.
3. Revising the RICT is not required If the plant configuration change would lower plant risk and would result in a longer RICT.
d.

Use of a RICT is not permitted for voluntary entry into a configuration which represents a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE.

e.

Use of a RICT is permitted for emergent conditions which represent a loss of a specified safety function or inoperability of all required trains of a system required to be OPERABLE if one or more of the trains are considered "PRA functional" as defined in Section 2.3.1 of NEI 06-09.]

Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program Page 15

d.

If the extent of condition evaluation for inoperable structures, systems, or components (SSCs) is not complete prior to exceeding the Completion Time, the RICT shall account for the increased possibility of common cause failure (CCF) by either:

1. Numerically accounting for the increased possibility of CCF in the RICT calculation; or
2. Risk Management Actions (RMAs) not already credited in the RICT calculation shall be implemented that support redundant or diverse SSCs that perform the function(s) of the inoperable SSCs, and, if practicable, reduce the frequency of initiating events that challenge the function(s) performed by the inoperable SSCs.
e.

[This paragraph will describe when prior NRC approval is needed for changes to the methodology used to calculate a RICT. The wording for this provision is currently under discussion between the NRC and the industry.]

Discussion of Recommended Changes to the Risk Informed Completion Time Program

1.

The reference to NEI 06-09 is revised to refer to the approved version, NEI 06-09-A, Revision

0.
2.

Paragraphs d. and e. of TSTF-505 are deleted. These paragraphs discuss determining a RICT when all trains of a system are inoperable and are not applicable to the near-term submittals that are the subject of this letter.

3.

The NRC questioned the difference between the TSTF-505 Risk Informed Completion Time (RICT) Program in paragraph 5.5.c and the NEI 06-09 Configuration Risk Management Program (CRMP). The traveler justification stated that the TS Section 5.5 RICT Program was the same as the NEI 06-09 CRMP; however, users of the TS may not have TSTF-505 available, which may lead to confusion when applying NEI 06-09 in accordance with the TS 5.5 RICT Program. The program was revised to clarify the application of the requirements.

4.

A new paragraph d. is added addressing common cause failure considerations.

5.

A new paragraph e. is added. The NRC's Safety Evaluation for NEI 06-09 stated:

As part of its review and approval of a licensees application requesting to implement the RMTS, the NRC staff intends to impose a license condition that will explicitly address the scope of the PRA and non-PRA methods approved by the NRC staff for use in the plant-specific RMTS program. If a licensee wishes to change its methods, and the change is outside the bounds of the license condition, the licensee will need NRC approval, via a license amendment, of the implementation of the new method in its RMTS program. The focus of the NRC staffs review and approval will be on the Recommended Variations from TSTF-505-A in Near-Term Plant-Specific Amendment Requests Recommended Changes to the Risk Informed Completion Time Program Page 16 technical adequacy of the methodology and analyses relied upon for the RMTS application.

There is no legal difference between a license condition and a Technical Specification and it is less error prone to put all requirements related to calculation of a RICT in the same location.

Therefore, in lieu of a license condition, the restriction is added as paragraph e. of the program.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Page 17 Specification LCO Requirements and Condition Condition on Use 3.3.8.B LCO: Three channels of loss of voltage Function and three channels of degraded voltage Function EDG LOPS instrumentation per EDG shall be OPERABLE.

Condition: One or more Functions with two or more channels per EDG inoperable.

Licensee must justify that two or more channels per EDG inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

3.3.12.B LCO: Two manual initiation switches per actuation channel for each of the following emergency feedwater initiation and control (EFIC)

Functions shall be OPERABLE:

a. Steam generator (SG) A Main Feedwater (MFW)

Isolation,

b. SG B MFW Isolation,
c. SG A Main Steam Line Isolation,
d. SG B Main Steam Line Isolation, and
e. Emergency Feedwater Actuation.

Condition: One or more EFIC Function(s) with one or both manual initiation switches inoperable in both actuation channels.

Licensee must justify that one or both channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Page 18 Specification LCO Requirements and Condition Condition on Use 3.4.9.C LCO: The pressurizer shall be OPERABLE.

Condition: Capacity of pressurizer heaters

[capable of being powered by emergency power supply] less than limit.

Pressurizer is typically not modeled in the PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.5.2.B LCO: Two ECCS trains shall be OPERABLE.

Condition: One or more [ECCS] trains inoperable for reasons other than one LPI subsystem inoperable.

Licensee must justify that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1430, Babcock and Wilcox STS Page 19 Specification LCO Requirements and Condition Condition on Use 3.6.2.C LCO: [Two] containment air lock[s] shall be OPERABLE. Condition: One or more containment air locks inoperable for reasons other than an inoperable door or inoperable interlock mechanism.

Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.

3.6.6 LCO: Containment Spray and Cooling Systems Condition A: One containment spray train inoperable Condition C: One [required] containment cooling train inoperable.

Condition D: One containment spray train and one

[required] containment cooling train inoperable.

Condition E: Two [required] containment cooling trains inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 20 Specification LCO Requirements and Condition Condition on Use 3.3.1.F LCO: The RTS instrumentation for each Function in Table 3.3.1-1 shall be OPERABLE.

Condition: One Power Range Neutron Flux - High channel inoperable.

Licensee must justify that the condition does not represent the inability to perform the safety function assumed in the FSAR given the loss of spacial distribution of the remaining Power Range detectors. The justification can include that the Actions require periodic monitoring of spacial power distribution and imposition of compensatory limits and reduced power.

3.3.1.DD LCO: The RTS instrumentation for each Function in Table 3.3.1-1 shall be OPERABLE.

Condition: One RTB train inoperable.

The licensee must include information regarding how the TSTF-411 conditions and limitations will be implemented (or similar conditions if TSTF-411 has not been adopted), including discussion of ATWS Mitigation System Actuation (AMSAC),

and why those actions are sufficient, including a discussion of defense in depth.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 21 Specification LCO Requirements and Condition Condition on Use 3.3.5.B LCO: [Three] channels per bus of the loss of voltage Function and [three] channels per bus of the degraded voltage Function shall be OPERABLE.

Condition: One or more Functions with two or more channels per bus inoperable.

Licensee must justify that two or more channels per bus inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

3.3.9.A LCO: Boron Dilution Protection System (BDPS)

Condition: One train inoperable (applicable to MODES [2,] 3, 4, and 5.)

BDPS is typically not modeled in the PRA.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.4.9.B LCO: The pressurizer shall be OPERABLE Condition: One [required] group of pressurizer heaters inoperable.

Pressurizer is typically not modeled in the PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 22 Specification LCO Requirements and Condition Condition on Use 3.5.2.A LCO: Two ECCS trains shall be OPERABLE.

Condition: One or more [ECCS] trains inoperable.

Licensee must justify that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.

3.6.2.C LCO: [Two] containment air lock[s] shall be OPERABLE. Condition: One or more containment air locks inoperable for reasons other than an inoperable door or inoperable interlock mechanism.

Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.

3.6.6A LCO: Containment Spray and Cooling Systems (Atmospheric and Dual) (Credit taken for iodine removal by the Containment Spray System)

Condition A: One containment spray train inoperable.

Condition C: One [required] containment cooling train inoperable.

Condition D: Two [required] containment cooling trains inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 23 Specification LCO Requirements and Condition Condition on Use 3.6.6B LCO: Containment Spray and Cooling Systems (Atmospheric and Dual (Credit not taken for iodine removal by the Containment Spray System)

Condition A: One containment spray train inoperable.

Condition B: One [required] containment cooling train inoperable.

Condition C: Two containment spray trains inoperable.

Condition D: One containment spray train and one

[required] containment cooling train inoperable.

Condition E: Two [required] containment cooling trains inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.6.6C.A LCO: Containment Spray System (Ice Condenser)

Condition: One containment spray train inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.6.6D.A LCO: Quench Spray (QS) System (Subatmospheric)

Condition: One QS train inoperable Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1431, Westinghouse STS Page 24 Specification LCO Requirements and Condition Condition on Use 3.6.6E LCO: Recirculation Spray (RS) System (Subatmospheric)

Condition A: One RS subsystem inoperable.

Condition B: Two RS subsystems inoperable in one train.

Condition C: Two inside RS subsystems inoperable Condition D: Two outside RS subsystems inoperable.

Condition E: Casing cooling tank inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.6.16.A LCO: The ice condenser inlet doors, intermediate deck doors, and top deck [doors] shall be OPERABLE and closed.

Condition: One or more ice condenser doors physically restrained from opening Licensee must justify that one or more inoperable doors is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

3.7.4.B LOC: [Three] Atmospheric Dump Valves (ADV) lines shall be OPERABLE.

Condition: Two or more required ADV lines inoperable Licensee must justify that two or more inoperable ADVs is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Page 25 Specification LCO Requirements and Condition Condition on Use 3.3.6.C (analog)

LCO: [Four] channels of Loss of Voltage Function and [four] channels of Degraded Voltage Function auto-initiation instrumentation per DG shall be OPERABLE.

Condition: One or more Functions with more than two channels inoperable.

Licensee must justify that more than two channels per bus inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

3.4.9.B LCO: The pressurizer shall be OPERABLE Condition: One [required] group of pressurizer heaters inoperable.

Pressurizer is typically not modeled in the PRA. Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.5.2.D LCO: Two ECCS trains shall be OPERABLE.

Condition: Less than 100% of the ECCS flow equivalent to a single OPERABLE train available.

Licensee must justify that one or more ECCS trains inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable. Acceptable justification is TS Condition requiring 100% flow equivalent to a single ECCS train.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Page 26 Specification LCO Requirements and Condition Condition on Use 3.6.2.C LCO: [Two] containment air lock[s] shall be OPERABLE. Condition: One or more containment air locks inoperable for reasons other than an inoperable door or inoperable interlock mechanism.

Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.2 requires the condition to be assessed in accordance with TS 3.6.1, Containment Integrity, and any loss of function would require an immediate plant shutdown under that TS.

3.6.6A LCO: Containment Spray and Cooling Systems (Atmospheric and Dual) (Credit taken for iodine removal by the Containment Spray System)

Condition A: One containment spray train inoperable.

Condition C: One containment cooling train inoperable.

Condition D: One containment spray and one containment cooling train inoperable.

Condition E: Two containment cooling trains inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1432, Combustion Engineering STS Page 27 Specification LCO Requirements and Condition Condition on Use 3.6.6B LCO: Containment Spray and Cooling Systems (Atmospheric and Dual) (Credit not taken for iodine removal by the Containment Spray System)

Condition A: One containment spray train inoperable.

Condition B: One containment cooling train inoperable.

Condition C: Two containment spray trains inoperable.

Condition D: One containment spray train and one containment cooling train inoperable.

Condition E: Two containment cooling trains inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Page 28 Specification LCO Requirements and Condition Condition on Use 3.3.1.2.A LCO: The SRM instrumentation in Table 3.3.1.2-1 shall be OPERABLE.

Condition: One or more required SRMs inoperable in MODE 2 with intermediate range monitors (IRMs) on Range 2 or below Licensee must justify that one or more inoperable SRMs is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.3.2.2.B LCO: [Three] channels of feedwater and main turbine high water level trip instrumentation shall be OPERABLE.

Condition: Two or more feedwater and main turbine high water level trip channels inoperable.

Licensee must justify that two or more inoperable trip channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Page 29 Specification LCO Requirements and Condition Condition on Use 3.3.4.1.A LCO: End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Condition: One or more required channels inoperable.

Licensee must justify that one or more inoperable EOC-RPT channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

Licensee must justify the ability to calculate a RICT given that EOC-RPT channels are not typically modeled in the PRA.

3.3.6.3.A LCO: Low-Low Set (LLS) Instrumentation Condition: One LLS valve inoperable due to inoperable channel(s).

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Page 30 Specification LCO Requirements and Condition Condition on Use 3.3.8.1.A LCO: The LOP instrumentation for each Function in Table 3.3.8.1-1 shall be OPERABLE.

Condition: One or more channels inoperable.

Licensee must justify that one or more channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

3.6.1.2.C LCO: The primary containment air lock shall be OPERABLE. Condition: Primary containment air lock inoperable for reasons other than Condition A or B.

Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1433, BWR/4 STS Page 31 Specification LCO Requirements and Condition Condition on Use 3.6.1.3.E LCO: Each PCIV, except reactor building-to-suppression chamber vacuum breakers, shall be OPERABLE.

Condition: One or more penetration flow paths with one or more containment purge valves not within purge valve leakage limits.

Licensee must justify that PCIV leakage in excess of the limits is not a condition in which all required trains or subsystems of a TS required system are inoperable.

Licensee must justify the ability to calculate a RICT for this inoperability.

3.6.1.7.D LCO: Each reactor building-to-suppression chamber vacuum breaker shall be OPERABLE.

Condition: Two or more lines with one or more reactor building -to-suppression chamber vacuum breakers inoperable for opening.

Licensee must justify that one or more inoperable vacuum breakers on two or more lines is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

3.7.7.A LCO: The Main Turbine Bypass System shall be OPERABLE.

OR The following limits are made applicable:

[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the [COLR]; and ]

[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for an inoperable Main Turbine Bypass System, as specified in the

[COLR]. ]

Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 32 Specification LCO Requirements and Condition Condition on Use 3.3.1.2.A LCO: The SRM instrumentation in Table 3.3.1.2-1 shall be OPERABLE.

Condition: One or more required SRMs inoperable in MODE 2 with intermediate range monitors (IRMs) on Range 2 or below.

Licensee must justify that one or more inoperable SRMs is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

Licensee must justify the ability to calculate a RICT given that SRMs are not typically modeled in the PRA.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 33 Specification LCO Requirements and Condition Condition on Use 3.3.4.1.A LCO: End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation Condition: One or more required channels inoperable.

Licensee must justify that one or more inoperable channels is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.3.6.5.A LCO: Relief and Low-Low Set (LLS)

Instrumentation Condition: One trip system inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 34 Specification LCO Requirements and Condition Condition on Use 3.3.8.1.A LCO: The LOP instrumentation for each Function in Table 3.3.8.1-1 shall be OPERABLE.

Condition: One or more channels inoperable.

Licensee must justify that one or more channels inoperable is not a condition in which all required trains or subsystems of a TS required system are inoperable or modify the Action to not apply a RICT when all required trains or subsystems are inoperable. See Note 1 at the end of.

3.6.1.2.C LCO: The primary containment air lock shall be OPERABLE. Condition: Primary containment air lock inoperable for reasons other than Condition A or B.

Licensee must justify that an inoperable containment air lock is not a condition in which all required trains or subsystems of a TS required system are inoperable. An acceptable argument may be that a note in TS 3.6.1.2 requires the condition to be assessed in accordance with TS 3.6.1.1, Primary Containment, and any loss of function would require an immediate plant shutdown under that TS.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 35 Specification LCO Requirements and Condition Condition on Use 3.6.1.3.E LCO: Each PCIV shall be OPERABLE.

Condition: One or more penetration flow paths with one or more containment purge valves not within purge valve leakage limits.

Licensee must justify that PCIV leakage in excess of the limits is not a condition in which all required trains or subsystems of a TS required system are inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.6.1.7.A LCO: Residual Heat Removal (RHR) Containment Spray System Condition: One RHR containment spray subsystem inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

3.7.4.A LCO: Two [control room AC] subsystems shall be OPERABLE.

Condition: One [control room AC] subsystem inoperable.

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests NUREG-1434, BWR/6 STS Page 36 Specification LCO Requirements and Condition Condition on Use 3.7.6.A LCO: The Main Turbine Bypass System shall be OPERABLE.

OR The following limits are made applicable:

[ a. LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the [COLR] and ]

[ b. LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for an inoperable Main Turbine Bypass System, as specified in the

[COLR]. ]

Condition: [Requirements of the LCO not met or Main Turbine Bypass System inoperable].

Licensee must justify the ability to calculate a RICT for the condition, including how the system is modeled in the PRA, whether all functions of the system are modeled, and, if a surrogate is used, why that modeling is conservative.

Conditional Variations from TSTF-505-A in Near-Term Plant-Specific License Amendment Requests Page 37 Note 1 Some Conditions are applicable when an unspecified number of subsystems or instrument channels are inoperable, typically written as "One or more" or "Two or more". These conditions currently apply when all subsystems or channels required to be operable to perform a function are inoperable, and application of a RICT in this situation is prohibited in the near-term TSTF-505 submittals.

To address this, it is recommended that the following modification to TSTF-505 be made to the Required Actions indicated in the Attachment 2 tables for Completion Times potentially applicable when all required subsystems or channels are inoperable.

The typical Completion Time is modified by TSTF-505 to state:

72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (i.e., the existing Completion Time)

OR In accordance with the Risk Informed Completion Time Program It is recommended that the second Completion Time be modified with a Note, as shown below:

72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (i.e., the existing Completion Time)

OR


NOTE-------------

Not applicable when

[all/four/both] required channels are inoperable.

In accordance with the Risk Informed Completion Time Program The bracketed number of channels will depend on the specification. This approach retains the existing requirements and limits the use of a RICT to conditions in which the function can still be performed.

The licensee must justify that the required function can still be performed absent an additional failure when a RICT is applied.

Alternatively, the licensee may modify the Condition to only apply when at least one subsystem or channel is operable, but this approach may require creating a new Condition or modifying an existing condition to retain the current requirements, or accepting a more restrictive requirement (such a LCO 3.0.3 entry).

TSTF-505 Model Application

Page PROPOSED MODEL APPLICATION FOR PLANT-SPECIFIC ADOPTION OF TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B" U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555

SUBJECT:

[PLANT]

DOCKET NO. 50-[XXX]

LICENSE AMENDMENT REQUEST TO REVISE TECHNICAL SPECIFICATIONS TO ADOPT RISK INFORMED COMPLETION TIMES TSTF-505, REVISION 1, "PROVIDE RISK-INFORMED EXTENDED COMPLETION TIMES - RITSTF INITIATIVE 4B."

REFERENCE:

Letter from the TSTF to U.S. NRC, "Response to NRC Questions on TSTF-505, 'Provide Risk-Informed Extended Completion Times'," dated DATE In accordance with the provisions of Section 50.90 of Title 10 of the Code of Federal Regulations (10 CFR), [LICENSEE] is submitting a request for an amendment to the Technical Specifications (TS) for [PLANT.]

The proposed amendment would modify TS requirements to permit the use of Risk Informed Completion Times in accordance with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b," as modified by the [DATE] letter from the TSTF to the NRC (Reference). The availability of this TS improvement was announced in the Federal Register on March 15, 2012 (77 FR 15399).

  • Attachment 1 provides a description and assessment of the proposed change, the requested confirmation of applicability, and plant-specific verifications.
  • Attachment 2 provides the existing TS pages marked up to show the proposed changes.
  • Attachment 3 provides revised (clean) TS pages.
  • Attachment 4 provides existing TS Bases pages marked up to show the proposed changes.

[LICENSEE] requests approval of the proposed license amendment by [DATE], with the amendment being implemented [BY DATE OR WITHIN X DAYS].

Page In accordance with 10 CFR 50.91(a)(1), "Notice for Public Comment," the analysis about the issue of no significant hazards consideration using the standards in 10 CFR 50.92 is being provided to the Commission.

In accordance with 10 CFR 50.91(b)(1), "Notice for Public Comment; State Consultation," a copy of this application, with attachments, is being provided to the designated [STATE] Official.

I declare [or certify, verify, state] under penalty of perjury that the foregoing is true and correct.

Executed on [date][Signature]

If you should have any questions regarding this submittal, please contact [NAME, TELEPHONE NUMBER].

Sincerely,

[Name, Title]

Attachments: 1. Description and Assessment

2. Proposed Technical Specification Changes (Mark-Up)
3. Revised Technical Specification Pages
4. Proposed Technical Specification Bases Changes (Mark-Up)

Enclosures:

1. List of Revised Required Actions to Corresponding PRA Functions
2. Information Supporting Consistency with Regulatory Guide 1.200, Revision 2.
3. Information Supporting Technical Adequacy of PRA Models Without PRA Standards Endorsed by Regulatory Guide 1.200, Revision 2.
4. Information Supporting Justification of Excluding Sources of Risk Not Addressed by the PRA Models.
5. Baseline CDF and LERF.
6. Justification of Application Of At-Power PRA Models to Shutdown Modes.
7. PRA Model Update Process.
8. Attributes of the CRMP Model.
9. Key Assumptions and Sources of Uncertainty.
10. Program Implementation
11. Monitoring Program
12. Risk Management Action Examples cc:

NRC Project Manager NRC Regional Office NRC Resident Inspector State Contact

ATTACHMENT 1 DESCRIPTION AND ASSESSMENT OF THE PROPOSED CHANGE License Amendment Request for Adoption of TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b"

1.0 DESCRIPTION

The proposed amendment would modify the Technical Specification (TS) requirements related to Completion Times (CTs) for Required Actions to provide the option to calculate a longer, risk-informed CT (RICT). A new program, the Risk-Informed Completion Time Program, is added to TS Section 5 Administrative Controls.

The methodology for using the RICT Program is described in NEI 06-09-A, "Risk-Informed Technical Specifications Initiative 4b, Risk-Managed Technical Specifications (RMTS)

Guidelines," Revision 0, which was approved by the NRC on May 17, 2007. Adherence to NEI 06-09-A is required by the RICT Program.

The proposed amendment is consistent with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b," as modified by the TSTF's [DATE] letter to the NRC, "Response to NRC Questions on TSTF-505, 'Provide Risk-Informed Extended Completion Times'." However, only those Required Actions described in Enclosure 1 are proposed to be changed, [which does not include all of the modified Required Actions in TSTF-505 and which includes some plant-specific Required Actions not included in TSTF-505].

2.0 ASSESSMENT

2.1 Applicability of Published Safety Evaluation

[LICENSEE] has reviewed the model safety evaluation dated [DATE] as part of the Federal Register Notice for Comment. This review included a review of the NRC staffs evaluation, as well as the supporting information provided to support TSTF-505 and the safety evaluation for NEI 06-09, as well as the TSTF's [DATE] letter on TSTF-505. [As described in the subsequent paragraphs,][LICENSEE] has concluded that the technical basis presented in the TSTF-505 proposal, the associated model safety evaluation prepared by the NRC staff, as modified by the TSTF letter on TSTF-505 are applicable to [PLANT, UNIT NOS.] and support incorporation of this amendment in the [PLANT] TS. ]

2.2 Verifications and Regulatory Commitments In accordance with Section 4.0, Limitations and Conditions, of the safety evaluation for NEI 06-09-A, the following is provided:

Page

1. Enclosure 1 identifies each of the TS Required Actions to which the RICT Program will apply, with a comparison of the TS functions to the functions modeled in the probabilistic risk assessment (PRA) of the structures, systems and components (SSCs) subject to those actions.
2. Enclosure 2 provides a discussion of the results of peer reviews and self-assessments conducted for the plant-specific PRA models which support the RICT Program, as required by Regulatory Guide (RG) 1.200 Section 4.2.
3. [Enclosure 3 provides a description of all PRA models used to support the RICT Program for which Nuclear Regulatory Commission endorsed standards are not available.]

[Enclosure 3 is not applicable since each PRA model used for the RICT Program is addressed using a standard endorsed by the Nuclear Regulatory Commission.]

4. Enclosure 4 provides appropriate justification for excluding sources of risk not addressed by the PRA models.
5. Enclosure 5 provides the plant-specific baseline CDF and LERF to confirm that the potential risk increases allowed under the RICT Program are acceptable.
6. [Enclosure 6 provides appropriate plant-specific justification for using at power PRA models in shutdown modes to which the RICT Program applies (modes 3 [and 4]).]

[Enclosure 6 is not applicable since the RICT Program is not being applied to shutdown modes.]

7. Enclosure 7 provides a discussion of the licensees programs and procedures that assure the PRA models that support the RICT Program are maintained consistent with the as-built, as-operated plant.
8. Enclosure 8 provides a description of how the baseline PRA model, which calculates average annual risk, is evaluated and modified for use in the Configuration Risk Management Program (CRMP) to assess real-time configuration risk, and describes the scope of, and quality controls applied to, the CRMP
9. Enclosure 9 provides a discussion of how the key assumptions and sources of uncertainty in the PRA models were identified, and how their impact on the RICT Program was assessed and dispositioned.
10. Enclosure 10 provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation, including risk management action (RMA) implementation.

Page

11. Enclosure 11 provides a description of the implementation and monitoring program as described in NEI 06-09, Section 2.3.2, Step 7.
12. Enclosure 12 provides a description of the process to identify and provide RMAs.

2.3 Optional Changes and Variations

[LICENSEE is not proposing any changes, variations, or deviations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE], except as described in the TSTF letter dated [DATE].] [LICENSEE is proposing the following changes or variations from the TS changes described in the TSTF-505, Revision 1, or the applicable parts of the NRC staffs model safety evaluation dated [DATE].

These options were recognized as acceptable changes or variations in TSTF-505 and the NRC staff's model safety evaluation.]

{NOTE: If a change or variation is not identified in TSTF-505, the NRC staff's model safety evaluation, or NEI 06-09 then provide the description and justification.}

[The [PLANT] TS utilize different [numbering][and][titles] than the Standard Technical Specifications on which TSTF-505 was based. Specifically, [describe differences between the plant-specific TS numbering and/or titles (including Required Actions and programs) and the TSTF-505 numbering and titles.] These differences are administrative and do not affect the applicability of TSTF-505 to the [PLANT] TS.]

3.0 REGULATORY SAFETY ANALYSIS 3.1 No Significant Hazards Consideration Determination

[LICENSEE] has evaluated the proposed change to the TS using the criteria in 10 CFR 50.92 and has determined that the proposed change does not involve a significant hazards consideration.

[PLANT, UNIT NOS.] requests adoption of an approved change to the standard technical specifications (STS) and plant-specific technical specifications (TS), to modify the TS requirements related to Completion Times for Required Actions to provide the option to calculate a longer, risk-informed Completion Time. The allowance is described in a new program in Chapter 5, "Administrative Controls," entitled the "Risk-Informed Completion Time Program."

As required by 10 CFR 50.91(a), an analysis of the issue of no significant hazards consideration is presented below:

1.

Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?

Page Response: No.

The proposed change permits the extension of Completion Times provided the associated risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change does not involve a significant increase in the probability of an accident previously evaluated because the change involves no change to the plant or its modes of operation. The proposed change does not increase the consequences of an accident because the design-basis mitigation function of the affected systems is not changed and the consequences of an accident during the extended Completion Time are no different from those during the existing Completion Time.

Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.

2.

Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?

Response: No.

The proposed change does not change the design, configuration, or method of operation of the plant. The proposed change does not involve a physical alteration of the plant (no new or different kind of equipment will be installed).

Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.

3.

Does the proposed change involve a significant reduction in a margin of safety?

Response: No.

The proposed change permit the extension of Completion Times provided risk is assessed and managed in accordance with the NRC approved Risk-Informed Completion Time Program. The proposed change implements a risk-informed configuration management program to assure that adequate margins of safety are maintained. Application of these new specifications and the configuration management program considers cumulative effects of multiple systems or components being out of service and does so more effectively than the current TS.

Therefore, the proposed change does not involve a significant reduction in a margin of safety.

Page Based on the above, [LICENSEE] concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.

4.0 ENVIRONMENTAL CONSIDERATION

[LICENSEE] has reviewed the environmental evaluation included in the model safety evaluation published on [DATE] ([ ] FR [ ]) as part of the Notice of Availability. [LICENSEE] has concluded that the NRC staff findings presented in that evaluation are applicable to [PLANT, NO.].

The proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed change meet the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.

ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGES (MARK-UP)

{provided by the licensee}

ATTACHMENT 3 REVISED TECHNICAL SPECIFICATION PAGES

{provided by the licensee}

ATTACHMENT 4 PROPOSED CHANGES TO TECHNICAL SPECIFICATION BASES CHANGES (MARK-UP) PAGES

{provided by the licensee}

ENCLOSURE 1 LIST OF REVISED REQUIRED ACTIONS TO CORRESPONDING PRA FUNCTIONS

{NOTE: This enclosure provides confirmation that the PRA models include the necessary scope of structures, systems, and components (SSCs) and their functions to address each proposed application of the RICT Program to the TS Required Actions.

TS conditions with insufficient TS operable equipment to meet the specified safety function of the system, are not to be included in the application.

List each TS Required Action to which the RICT Program may be applied and, for each Required Action, describe the following:

The TS Required Action; The corresponding SSC; Each design basis function of the SSC; How each design basis function is modeled in the PRA. If one of the design basis functions of an SSC or the SSC is not modeled in the PRA, describe any proposed surrogates and why the proposed surrogate adequately captures the configuration risk; and The success criteria used in the PRA model compared to the licensing basis criteria. The success criteria should include both train-level and component/parameter level.

Note that the above description should be at the level of the TS condition/TS Required Action (not at the LCO level only). If the TS condition/ TS Required action covers multiple SSCs or multiple design basis functions, such as in the case ESFAS Instrumentation or Containment Sprays, describe each one individually.

The enclosure should also include clear definitions of any used terms, such as train, division, loop, "subsystem," etc.

The enclosure should provide a detailed system description of TS 3.8, "Electrical Power Systems," Required Actions if the loading scheme is not uniform (e.g., Train A and B have similar loading, except Train B supplies power to additional SSCs.) Also, provide a description in Enclosure 12 of representative RMAs for non-uniform trains to demonstrate that the systems safety function is maintained with either train or subsystem operable.}

ENCLOSURE 2 INFORMATION SUPPORTING CONSISTENCY WITH REGULATORY GUIDE 1.200, REVISION 2

{NOTE: This enclosure provides information supporting the licensee evaluation of the technical adequacy of the PRA models supporting the RICT Program based on peer reviews and self-assessments against the relevant PRA standards as endorsed in the current applicable revision of RG 1.200, including consideration of staff clarifications of the standards.

Per NEI 06-09 Rev. 0, capability category II of the standards is applicable; therefore, the licensee identifies those parts of the PRAs that conform to capability categories lower than II, and provides a disposition for the RICT Program. Consistent with RG 1.200 Section 4.2, the licensee identifies and provides a discussion of the resolution of any findings and observations from the peer reviews or self-assessments.

The licensee assessment must also address the clarifications and qualifications found in RG 1.200, either by a separate discussion provided by the licensee, or by confirmation that the peer reviews or self-assessments included consideration of the clarifications and qualifications of the current applicable RG 1.200 revision.

Licensees are strongly encouraged to apply the guidance in Appendix X, "Close out of Facts and Observations," of NEI 05-04, "Process for Performing Internal Events PRA Peer Reviews Using the ASME/ANS PRA Standard, Rev 3, November 2009," NEI 07-12, "Fire Probabilistic Risk Assessment Peer Review Process Guidelines, Rev 1, June 2010," and NEI 12-13, "External Hazards PRA Peer Review Process Guidelines, Rev 0, August 2012," to close PRA peer review findings, as this will make more efficient use of the NRC and industry resources needed to develop and review of the application. }

ENCLOSURE 3 INFORMATION SUPPORTING TECHNICAL ADEQUACY OF PRA MODELS WITHOUT PRA STANDARDS ENDORSED BY REGULATORY GUIDE 1.200, REVISION 2

{NOTE: This enclosure provides information supporting the licensee evaluation of the PRA models supporting the RICT Program for which the relevant PRA standards are not yet endorsed in the current applicable revision of RG 1.200.

RG 1.200 Rev. 2 endorses standards for internal and external events including internal floods and fires, seismic events, and other external hazards for full power conditions.

This scope includes the relevant hazard groups applicable to a RICT Program unless the program is to apply to lower modes of operation. In this case, shutdown and transition risk PRA models may apply but are not be covered by an endorsed standard.

If applicable, the licensee should provide a detailed description of these PRA models and the basis for its determination of their technical adequacy to support the RICT Program.}

ENCLOSURE 4 INFORMATION SUPPORTING JUSTIFICATION OF EXCLUDING SOURCES OF RISK NOT ADDRESSED BY THE PRA MODELS

{NOTE: This enclosure identifies and provides a justification for excluding sources of risk which are not in the scope of the PRA models applied to the RICT Program.

Exclusion of risk sources determined to be insignificant to the calculation of configuration specific risk, or the use of conservative or bounding analyses for the calculation of RICTs in lieu of realistic PRA models, are described. A qualitative treatment may be sufficient if the licensee demonstrates that those risk contributions would not affect decisions in a RICT Program. The use of conservative bounding calculations in a RICT Program may also be acceptable. However, when the risk associated with a particular hazard group would affect decisions, it is the Commissions policy that risk be assessed using a PRA that meets the staff-endorsed PRA standard.

External hazards screened out from inclusion in RICT calculations should be clearly identified as such, and should be done in a manner consistent with Part 6 of the ASME ANS PRA Standard. The justification should address baseline and configuration-specific considerations.

For external hazards that are not screened out from inclusion in RICT calculations, the licensee may propose a bounding approach to address the hazard. If the bounding approach involves assuming a uniform increase in baseline risk to address the hazard, the licensee will need to address potential RICT-specific impacts by doing one of the following:

  • Demonstrate in the LAR that this approach is bounding for all TS actions included in the LAR, or
  • Establish a procedure to evaluate the validity of the bounding approach when calculating an RICT that is not demonstrated to be bounded in the LAR, or For RICTs not demonstrated to be bounded in the LAR, establish a procedure to qualitatively evaluate the impact of the specific external hazard for each RICT when calculated and apply risk management actions as appropriate. }

ENCLOSURE 5 BASELINE CDF AND LERF

{NOTE: This enclosure provides the plant-specific total CDF and total LERF to confirm that these are less than 10-4/year and 10-5/year, respectively. This assures that the potential risk increases allowed under the RICT Program are consistent with RG 1.174, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," Revision 2.

The licensee should provide the totals and the contributions from each hazard group (internal events, fires, floods, seismic, other external). }

ENCLOSURE 6 JUSTIFICATION OF APPLICATION OF AT-POWER PRA MODELS TO SHUTDOWN MODES

{NOTE: This enclosure provides a justification for the use of existing PRA models during shutdown conditions if the RICT Program is applicable in these shutdown conditions.

The at-power PRA models may potentially be applied to lower modes of operation (hot standby for PWRs, and hot shutdown for PWRs and BWRs) for some Required Actions.

If the licensee is not proposing to use the RICT Program in these modes, then this information is not required and this Enclosure should be marked "Not applicable."

Otherwise, the licensee provides a detailed justification for those Required Actions proposed to apply the RICT Program in lower modes of operation using the at-power PRA models.}

ENCLOSURE 7 PRA MODEL UPDATE PROCESS

{NOTE: This enclosure describes how the PRA models used in the calculation of completion times is maintained consistent with the as-built, as-operated plant.

The licensee provides a discussion of its programs and procedures to assure the PRA models that support the RICT Program are maintained consistent with the as-built, as-operated plant. This should include a discussion of the timing of significant PRA model changes as described in NEI 06-09, Section 2.3.4, Step 7.}

ENCLOSURE 8 ATTRIBUTES OF THE CRMP MODEL

{NOTE: This enclosure describes how the baseline PRA model, which calculates average annual risk, is evaluated and modified for use in the Configuration Risk Management Program (CRMP) to assess real-time configuration risk, and describes the scope of, and quality controls applied to, the CRMP.

The licensee provides a description of the PRA models and CRMP used to support the RICT Program. The following specific attributes must also be addressed:

  • The baseline PRA models assess the average annual risk. However, some risk is not consistent throughout the year or the operating cycle, and the PRA models used for the CRMP need to properly assess the change in risk for the existing plant conditions. For example, success criteria may be different at core beginning of life compared to end of life, or at different times of the year for room cooling systems. The licensee describes these issues and how they are addressed in the CRMP.
  • The baseline PRA models may assume some configurations are not allowable, but these assumptions may not be applicable to a CRMP. The licensee describes these issues and how they are addressed in the CRMP.
  • The scope of SSCs within the CRMP is provided, along with confirmation that the CRMP tools can be readily applied for each TS Required Action within the scope of the Risk-Informed Completion Time Program. The licensee should also identify and justify SSCs that are not included in the CRMP that could provide accident mitigation functions.
  • The licensee describes how consistency of calculated results from the baseline PRA model and the CRMP are verified to assure the CRMP PRA models are consistent with the baseline model and updated when the baseline PRA model is updated.
  • The licensee describes the quality requirements applied to the CRMP PRA models.
  • The licensee describes the training and qualification programs applicable to personnel responsible for development and use of the CRMP.}

ENCLOSURE 9 KEY ASSUMPTIONS AND SOURCES OF UNCERTAINTY

{NOTE: This enclosure describes the key assumptions and sources of uncertainty in the PRA models, and how their impact on the RICT Program was assessed and dispositioned. Sensitivity analyses for various plant configuration cases under different assumptions should be provided to justify conclusions.}

ENCLOSURE 10 PROGRAM IMPLEMENTATION

{NOTE: This enclosure provides a description of the implementing programs and procedures regarding the plant staff responsibilities for the RICT Program implementation including training of plant personnel, and specifically discusses the decision process for risk management action (RMA) implementation during extended CTs.}

ENCLOSURE 11 MONITORING PROGRAM

{NOTE: This enclosure describes the monitoring program for cumulative risk impacts as described in NEI 06-09, Revision 0, Section 2.3.2, Step 7. This should include a description of how the calculations are made and what actions and thresholds are applied when corrective measures are necessary due to excessive risk increases.}

ENCLOSURE 12 RISK MANAGEMENT ACTION EXAMPLES

{NOTE: This enclosure describes the process for identification of RMAs applicable during extended CTs, and provides examples of RMAs.

Provide example RMAs for TS 3.8 Required Actions. These should be representative examples, such as a long and short RICTs. See the Plant Vogtle April 14, 2017 RAI response (ADAMS Accession No. ML17108A253) for an example.

If the TS-required electrical power loading scheme is not uniform (e.g., Train A and B have similar loading, except Train B supplies power to additional SSCs,) provide a description of representative RMAs for non-uniform trains to ensure that the systems safety function is maintained with either train or subsystem inoperable.}