| title = Auxiliary Feedwater Actuation On A Manual Reactor Trip
| title = Auxiliary Feedwater Actuation on a Manual Reactor Trip
| event text = Auxiliary Feedwater actuation due to low steam generator level following a manual reactor trip.
| event text = Auxiliary Feedwater actuation due to low steam generator level following a manual reactor trip.
At 0702 on 10/15/05, a manual reactor trip was initiated due to decreasing level on the 3C steam generator. Auxiliary Feedwater system actuated as expected due to post-trip steam generator level decrease. 3C steam generator level was restored using Auxiliary and Main feed. The cause of the loss of steam generator level control is under investigation.  
At 0702 on 10/15/05, a manual reactor trip was initiated due to decreasing level on the 3C steam generator. Auxiliary Feedwater system actuated as expected due to post-trip steam generator level decrease. 3C steam generator level was restored using Auxiliary and Main feed. The cause of the loss of steam generator level control is under investigation.  

Latest revision as of 21:20, 1 March 2018

ENS 42056 +/-
Where
Turkey Point NextEra Energy icon.png
Florida (NRC Region 2)
Reporting
10 CFR 50.72(b)(3)(iv)(A), System Actuation

10 CFR 50.72(b)(2)(iv)(B), RPS Actuation
Time - Person (Reporting Time:+-2.13 h-0.0888 days <br />-0.0127 weeks <br />-0.00292 months <br />)
Opened: Jim Speicher
08:54 Oct 15, 2005
NRC Officer: Pete Snyder
Last Updated: Oct 19, 2005
42056 - NRC Website
Loading map...