ENS 44430: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 08/20/2008 16:41 EDT | | event date = 08/20/2008 16:41 EDT | ||
| last update date = 09/15/2008 | | last update date = 09/15/2008 | ||
| title = Massachusetts Agreement State Report - Radiation Greater | | title = Massachusetts Agreement State Report - Radiation Greater than Ten Times Limit | ||
| event text = [A] technician working with a 113 Ci Ir-192 source set off high radiation alarms at [the QSA Global facility] which caused the immediate evacuation of the building. Radiation surveys outside the building indicated a dose rate of approximately 3 Mr/hr at a distance of 25 feet from the exterior of the building. Radiation safety staff performed a source retrieval to recover the source and place it in a shielded container; the building was reoccupied approximately 30 minutes later. | | event text = [A] technician working with a 113 Ci Ir-192 source set off high radiation alarms at [the QSA Global facility] which caused the immediate evacuation of the building. Radiation surveys outside the building indicated a dose rate of approximately 3 Mr/hr at a distance of 25 feet from the exterior of the building. Radiation safety staff performed a source retrieval to recover the source and place it in a shielded container; the building was reoccupied approximately 30 minutes later. | ||
Preliminary investigation of the technician indicated his electronic dosimeter (worn on the side of the body closest to the source) showed an exposure of 720 mRem. The technician was not wearing his extremity ring badge at the time, however the radiation safety officer calculated a maximum exposure to the tips of the maximally exposed fingers to be approximately 2 Rem. Dosimetry for both the technician involved and another that was nearby when the incident occurred have been sent to the vendor for immediate processing. | Preliminary investigation of the technician indicated his electronic dosimeter (worn on the side of the body closest to the source) showed an exposure of 720 mRem. The technician was not wearing his extremity ring badge at the time, however the radiation safety officer calculated a maximum exposure to the tips of the maximally exposed fingers to be approximately 2 Rem. Dosimetry for both the technician involved and another that was nearby when the incident occurred have been sent to the vendor for immediate processing. |
Latest revision as of 21:13, 1 March 2018
Where | |
---|---|
Qsa Global, Inc. Burlington, Massachusetts (NRC Region 1) | |
License number: | 12-8361 |
Organization: | Ma Radiation Control Program |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+11.63 h0.485 days <br />0.0692 weeks <br />0.0159 months <br />) | |
Opened: | Robert Gallaghar 08:19 Aug 21, 2008 |
NRC Officer: | Dan Livermore |
Last Updated: | Sep 15, 2008 |
44430 - NRC Website | |