{{#Wiki_filter:3 Draft 1 October 15, 1979 PROPOSED REVISION 2 TO REGULATORY GUIDE 1.97 INSTRUMENTATION FOR LIGHT-WATER-COOLED NUCLEAR POWER PLANTS TO ASSESS PLANT AND ENVIRONS CONDITIONS DURING AND FOLLOWING AN ACCIDENT A. INTRODUCTION Criterion 13, "Instrumentation and Control," of Appendix A, "General Design Criteria for Nuclear Power Plants," to 10 CFR Part 50, "Licensing of Production and Utilization Facilities," includes a requirement that instrumentation be provided to monitor variables and systems for accident conditions as appropriate to ensure adequate safety.Criterion 19, "Control Room," of Appendix A to 10 CFR Part 50 includes a requirement that a control room be provided from which actions can be taken to maintain the nuclear power unit in a safe condition under accident conditions, including loss-of-coolant accidents and that equipment at appropriate locations outside the control room be provided with a design capability for prompt hot shutdown of the reactor including necessary instrumentation.
{{#Wiki_filter:3 Draft 1 October 15, 1979 PROPOSED REVISION 2 TO REGULATORY GUIDE 1.97 INSTRUMENTATION FOR LIGHT-WATER-COOLED NUCLEAR POWER PLANTS TO ASSESS PLANT AND ENVIRONS CONDITIONS DURING AND FOLLOWING AN ACCIDENT A. INTRODUCTION Criterion 13, "Instrumentation and Control," of Appendix A, "General Design Criteria for Nuclear Power Plants," to 10 CFR Part 50, "Licensing of Production and Utilization Facilities," includes a requirement that instrumentation be provided to monitor variables and systems for accident conditions as appropriate to ensure adequate safety.
Criterion 19, "Control Room," of Appendix A to 10 CFR Part 50 includes a requirement that a control room be provided from which actions can be taken to maintain the nuclear power unit in a safe condition under accident conditions, including loss-of-coolant accidents and that equipment at appropriate locations outside the control room be provided with a design capability for prompt hot shutdown of the reactor including necessary instrumentation.
Criterion 64, "Monitoring Radioactivity Releases," of Appendix A to 10 CFR Part 50 includes a requirement that means be provided for monitoring the reactor containment atmosphere, spaces containing components for recirculation of loss-of-coolant accident fluid, effluent discharge paths, and the plant environs for radioactivity that may be released from postulated accidents.
Criterion 64, "Monitoring Radioactivity Releases," of Appendix A to 10 CFR Part 50 includes a requirement that means be provided for monitoring the reactor containment atmosphere, spaces containing components for recirculation of loss-of-coolant accident fluid, effluent discharge paths, and the plant environs for radioactivity that may be released from postulated accidents.
This guide describes a method acceptable to the NRC staff for complying with the Commission's regulations to provide instrumentation to monitor plant variables and systems during and following an accident in a light-water-cooled nuclear power plant.1.97-1 aK B. DISCUSSION Indications of plant variables and status of systems important to safety are required by the plant operator (licensee) during accident situations to (1) provide information required to permit the operator to take pre-planned manual actions to accomplish safe plant shutdown; (2) determine whether the reactor trip, engineered-safety-feature systems, and manually initiated systems are performing their intended functions, i.e., reactivity control, core cooling, maintaining reactor coolant system integrity, and maintaining containment integrity; (3) provide information to the operator that will enable him to determine the potential for causing a breach of the barriers to radioactivity release (i.e., fuel cladding, reactor coolant pressure boundry and containment) and if a barrier has been breached; (4) furnish data for deciding on the need to take unplanned action if an automatic or manually initiated safety system is not functioning properly or the plant is not responding properly to the safety systems in operation; (5) allow for early indication of the need to initiate action necessary to protect the public and for an estimate of the magnitude of the impending threat.At the start of an accident, it may be difficult for the operator to deter-mine immediately what accident has occurred or is occurring and, therefore, determine the appropriate response.
This guide describes a method acceptable to the NRC staff for complying with the Commission's regulations to provide instrumentation to monitor plant variables and systems during and following an accident in a light-water-cooled nuclear power plant.
For this reason, reactor trip and certain other safety actions (e.g., emergency core cooling actuation, containment isola-tion, or depressurization) have been designed to be performed automatically during the initial stages of an accident.
1.97-1                       aK
Instrumentation is also provided to indicate information about plant parameters required to enable the operation of manually initiated safety systems and other appropriate operator actions involv-ing systems important to safety.1.97-2
 
* S Instrumentation is also needed to provide information about some plant parameters that will alert the operator to conditions that have degraded beyond those postulated in the accident analysis so that the operator can take actions that are available to mitigate the consequences.
B. DISCUSSION Indications of plant variables and status of systems important to safety are required by the plant operator (licensee) during accident situations to (1) provide information required to permit the operator to take pre-planned manual actions to accomplish safe plant shutdown; (2) determine whether the reactor trip, engineered-safety-feature systems, and manually initiated systems are performing their intended functions, i.e., reactivity control, core cooling, maintaining reactor coolant system integrity, and maintaining containment integrity; (3) provide information to the operator that will enable him to determine the potential for causing a breach of the barriers to radioactivity release (i.e.,
It is not intended that the operator be encouraged to circumvent systems important to safety prematurely, but that he be adequately informed in order that unplanned actions can be taken when necessary.
fuel cladding, reactor coolant pressure boundry and containment) and if a barrier has been breached; (4) furnish data for deciding on the need to take unplanned action if an automatic or manually initiated safety system is not functioning properly or the plant is not responding properly to the safety systems in operation; (5) allow for early indication of the need to initiate action necessary to protect the public and for an estimate of the magnitude of the impending threat.
Examples of serious events that could threaten safety if conditions degrade beyond those assumed in the Final Safety Analysis Report are loss-of-coolant accidents (LOCAs), overpressure transients, ATWSs reactivity excursions, and releases of radioactive materials.
At the start of an accident, it may be difficult for the operator to deter-mine immediately what accident has occurred or is occurring and, therefore, determine the appropriate response. For this reason, reactor trip and certain other safety actions (e.g., emergency core cooling actuation, containment isola-tion, or depressurization) have been designed to be performed automatically during the initial stages of an accident. Instrumentation is also provided to indicate information about plant parameters required to enable the operation of manually initiated safety systems and other appropriate operator actions involv-ing systems important to safety.
Such events require that the operator under-stand, in a short time period, the ability of the barriers to limit radioactivity release, i.e., the potential for breach of a barrier, or an actual breach of a barrier by an accident in progress.It is essential that the required instrumentation be capable of surviving the accident environment in which it is located for the length of time its func-tion is required as defined by ANS-4.-5, Section 3.0. It could therefore either be designed to withstand the accident environment or be protected by a local protected environment.
1.97-2
If the environment surrounding an instrument component is the same for accident and normal operating conditions (e.g., some instrumen-tation components outside of containment or those in the main control room powered by a Class lE source), the instrumentation components need no special environmental qualification.
* S Instrumentation is also needed to provide information about some plant parameters that will alert the operator to conditions that have degraded beyond those postulated in the accident analysis so that the operator can take actions that are available to mitigate the consequences. It is not intended that the operator be encouraged to circumvent systems important to safety prematurely, but that he be adequately informed in order that unplanned actions can be taken when necessary.
It is important that accident-monitoring instrumentation components and their mounts that cannot be located in other than non-Seismic Category I build-ings be conservatively designed for the intended service.1.97-3 Parameters selected for accident monitoring can be selected so as to permit relatively few instruments to provide the essential information needed by the operator for postaccident monitoring.
Examples of serious events that could threaten safety if conditions degrade beyond those assumed in the Final Safety Analysis Report are loss-of-coolant accidents (LOCAs), overpressure transients, ATWSs reactivity excursions, and releases of radioactive materials. Such events require that the operator under-stand, in a short time period, the ability of the barriers to limit radioactivity release, i.e., the potential for breach of a barrier, or an actual breach of a barrier by an accident in progress.
Further, it is prudent that a limited number of those parameters (e.g., containment pressure, primary system pressure)be monitored by instruments qualified to more stringent environmental require-ments and with ranges that extend well beyond that which the selected parameters can attain under limiting conditions.
It is essential that the required instrumentation be capable of surviving the accident environment in which it is located for the length of time its func-tion is required as defined by ANS-4.-5, Section 3.0. It could therefore either be designed to withstand the accident environment or be protected by a local protected environment. If the environment surrounding an instrument component is the same for accident and normal operating conditions (e.g., some instrumen-tation components outside of containment or those in the main control room powered by a Class lE source), the instrumentation components need no special environmental qualification.
It is essential that the range selections not be arbitrary but sufficiently high that the instruments will always be on-scale; for example, a range for the containment pressure monitor extending to the burst pressure of the containment in order that the operator will not be blind as to the level of containment pressure.
It is important that accident-monitoring instrumentation components and their mounts that cannot be located in other than non-Seismic Category I build-ings be conservatively designed for the intended service.
Provisions of such instruments are important so that responses to corrective actions can be observed and the need for, and magnitude of, further actions determined.
1.97-3
On the other hand, we should also make sure that when a range is extended, the sensitivity and accu-racy of the instrument are within acceptable limits.Normal power plant instrumentation remaining functional for all accident conditions can provide indication, records, and (with certain types of instru-ments) time-history responses for many parameters important to following the course of the accident.
 
Therefore, it is prudent to select the required accident-monitoring instrumentation from the normal power plant instrumentation to enable the operator to use, during accident situations, instruments with which he is most familiar.
Parameters selected for accident monitoring can be selected so as to permit relatively few instruments to provide the essential information needed by the operator for postaccident monitoring. Further, it is prudent that a limited number of those parameters (e.g., containment pressure, primary system pressure) be monitored by instruments qualified to more stringent environmental require-ments and with ranges that extend well beyond that which the selected parameters can attain under limiting conditions. It is essential that the range selections not be arbitrary but sufficiently high that the instruments will always be on-scale; for example, a range for the containment pressure monitor extending to the burst pressure of the containment in order that the operator will not be blind as to the level of containment pressure. Provisions of such instruments are important so that responses to corrective actions can be observed and the need for, and magnitude of, further actions determined. On the other hand, we should also make sure that when a range is extended, the sensitivity and accu-racy of the instrument are within acceptable limits.
Since some accidents impose severe operating requirements on instrumen-tation components, it may be necessary to upgrade those instrumentation components to withstand the more severe operating conditions and to measure greater variations of monitored variables that may be associated with the accident if they are to be 1.97-4 used for both accident and normal operation.
Normal power plant instrumentation remaining functional for all accident conditions can provide indication, records, and (with certain types of instru-ments) time-history responses for many parameters important to following the course of the accident. Therefore, it is prudent to select the required accident-monitoring instrumentation from the normal power plant instrumentation to enable the operator to use, during accident situations, instruments with which he is most familiar. Since some accidents impose severe operating requirements on instrumen-tation components, it may be necessary to upgrade those instrumentation components to withstand the more severe operating conditions and to measure greater variations of monitored variables that may be associated with the accident if they are to be 1.97-4
However, it is essential that instru-mentation so upgraded does not compromise the accuracy and sensitivity required for normal operation.
 
In some cases this will necessitate use of overlapping ranges of instruments to monitor the required range of the parameter to be monitored.
used for both accident and normal operation. However, it is essential that instru-mentation so upgraded does not compromise the accuracy and sensitivity required for normal operation. In some cases this will necessitate use of overlapping ranges of instruments to monitor the required range of the parameter to be monitored.
Draft Standard ANS-4.5, "Functional Requirements for Post Accident Monitoring Capability for the Control Room Operator of a Nuclear Power Generating Station," dated September 1979, delineates criteria for determining the variables to be monitored by the control room operator, as required for safety, during the course of an accident and during the long-term stable shutdown phase followng an accident.Draft Standard ANS-4.5 was prepared by ANS 4 Working Group 4.5 with two primary objectives, (1) to address that instrumentation which permits the operator to monitor expected parameter changes in an accident period, and (2) to address extended range instrumentation deemed appropriate for the possibility of encounter-ing previously unforeseen events.The standard defines four classifications of variable types for the purpose of aiding the designer in his selection of accident monitoring instrumentation and applicable criteria. (A fifth type (Type E) has been added by this regula-tory guide.) The types are, (1) Type A -those variables that provide-informa-tion needed for pre-planned operator actions, (2) Type B -those variables that provide information to indicate whether plant safety functions are being accom-plished, (3) Type C -those variables that provide information to indicate the potential for being breached or the actual breach of the barriers to fission product release, i.e., fuel cladding, primary coolant pressure boundary., and containment, (4) Type D -those variables that provide information to indicate the performance of individual safety systems, and (5) Type E -those variables to be monitored as required to provide defense-in-depth and for diagnosis and 1.97-5 other useful purposes.
Draft Standard ANS-4.5, "Functional Requirements for Post Accident Monitoring Capability for the Control Room Operator of a Nuclear Power Generating Station,"
Type A variables have not been included in the listings of variables to be measured because they are plant specific and will depend upon the operations that the designer chooses for pre-planned manual action.The five classifications are not mutually exclusive in that a given variable (or instrument) may be included in one or more types, as well as for normal power plant operation.
dated September 1979, delineates criteria for determining the variables to be monitored by the control room operator, as required for safety, during the course of an accident and during the long-term stable shutdown phase followng an accident.
Where such multiple listing occurs, it is essential that instrumentation be capable of meeting the most stringent requirements.
Draft Standard ANS-4.5 was prepared by ANS 4 Working Group 4.5 with two primary objectives, (1) to address that instrumentation which permits the operator to monitor expected parameter changes in an accident period, and (2) to address extended range instrumentation deemed appropriate for the possibility of encounter-ing previously unforeseen events.
The time phases (Phases I, II, & III) delineated in ANS-4.5 are not speci-fied for each variable in this regulatory guide. These considerations are plant specific.
The standard defines four classifications of variable types for the purpose of aiding the designer in his selection of accident monitoring instrumentation and applicable criteria.   (A fifth type (Type E) has been added by this regula-tory guide.)   The types are, (1) Type A - those variables that provide-informa-tion needed for pre-planned operator actions, (2) Type B - those variables that provide information to indicate whether plant safety functions are being accom-plished, (3) Type C - those variables that provide information to indicate the potential for being breached or the actual breach of the barriers to fission product release, i.e., fuel cladding, primary coolant pressure boundary., and containment, (4) Type D - those variables that provide information to indicate the performance of individual safety systems, and (5) Type E - those variables to be monitored as required to provide defense-in-depth and for diagnosis and 1.97-5
It is important that the required instrumentation survive the accident environment and function as long as the information it provides is needed by the plant operator.C. REGULATORY POSITION The criteria, requirements, and recommendations contained in Draft Standard ANS-4.5, "Functional Requirements for Post Accident Monitoring Capability for the Control Room Operator of a Nuclear Power Generating Station," dated September 1979, are considered by the NRC staff to be generally acceptable for providing instrumentation to monitor variables and systems for accident condi-tions and for monitoring the reactor containment, spaces containing components for recirculation of loss-of-coolant accident fluids, effluent discharge paths, and the plant environs for radioactivity that may be released during and follow-ing an accident from a nuclear power plant subject to the following:
 
(1) Section 2.0 of ANSI-4.5, defines the scope of the standard as contain-ing criteria for determining the variables to be monitored by the control room operator during and following an accident that will need some operator action.1.97-6 Consideration should be given to the additional requirements (e.g., emergency planning) of variables to be monitored by the plant operator (licensee) during and following an accident.
other useful purposes. Type A variables have not been included in the listings of variables to be measured because they are plant specific and will depend upon the operations that the designer chooses for pre-planned manual action.
Instrumentation selected for use by the plant opera-tor for monitoring conditions of the plant are useful in an emergency situation and for other purposes and therefore should be factored into the emergency plans action level criteria.(2) In Section 3.0 of ANS-4.5, the definition of "Type C" includes two items, (1) and (2). Item (1) includes those instruments that indicate the extent to which parameters, which indicate the potential for a breach in the containment, have exceeded the design basis values. In conjunction with the parameters that indicate the potential for a breach in the containment, the parameters that have the potential for causing a breach in the fuel cladding (e.g., core exit temperature) and the reactor coolant pressure boundary (e.g., reactor coolant pressure) should also be included.
The five classifications are not mutually exclusive in that a given variable (or instrument) may be included in one or more types, as well as for normal power plant operation. Where such multiple listing occurs, it is essential that instrumentation be capable of meeting the most stringent requirements.
References to Type C instru-ments, and associated parameters to be measured, in Draft Standard ANS-4.5 should include this expanded definition, e.g., Section 4.2, Section 5.0c, Section 5.1.3, Section 5.2.2, Section 6.3.(3) Section 3.0 of ANS-4.5 defines design basis accident events. In conjunction with the design basis accident events delineated in the standard, those events which are expected to occur one or more times during the life of a nuclear power unit and include but are not limited to loss of power to all recirculating pumps, tripping of the turbine generator set, isolation of the main condenser, and loss of all offsite power, should be included.(4) Section 4.2 of ANS-4.5, discusses the various types of variables.
The time phases (Phases I, II, & III) delineated in ANS-4.5 are not speci-fied for each variable in this regulatory guide. These considerations are plant specific. It is important that the required instrumentation survive the accident environment and function as long as the information it provides is needed by the plant operator.
With regard to the discussion of Type D variables, Type 0 variables and instru-ments are within the scope of Accident Monitoring Instrumentation, although 1. 97-7 they are not addressed in Oraft Standard ANS-4.5. They are, however, along with an additional type, Type E, included in this regulatory guide. (See Tables 1, 2 and 3)(5) Section 5.2.1(5) of ANS-4.5 pertains to the delineation of the local environment in which instruments must operate. Section 5.2.1(5) should be understood to require identification of the range of the local physical and electrical environments (e.g., normal, abnormal, accident, and post-accident) in which all of the various instrumentation components are required to operate (e.g., sensors, cables, signal conditioning equipment, indicators).
C. REGULATORY POSITION The criteria, requirements, and recommendations contained in Draft Standard ANS-4.5, "Functional Requirements for Post Accident Monitoring Capability for the Control Room Operator of a Nuclear Power Generating Station," dated September 1979, are considered by the NRC staff to be generally acceptable for providing instrumentation to monitor variables and systems for accident condi-tions and for monitoring the reactor containment, spaces containing components for recirculation of loss-of-coolant accident fluids, effluent discharge paths, and the plant environs for radioactivity that may be released during and follow-ing an accident from a nuclear power plant subject to the following:
(6) Section 5.2.2 of ANS-4.5 pertains to the performance requirements for Type C instrumentation.
(1) Section 2.0 of ANSI-4.5, defines the scope of the standard as contain-ing criteria for determining the variables to be monitored by the control room operator during and following an accident that will need some operator action.
In conjunction with Section 5.2.2, there should be:.(1) Identification of the range of the process variable. (Note -the range selected should extend well beyond that which the variable value can attain under limiting conditions)
1.97-6
(2) Identification of the required accuracy of measurement (3) Identification of the required response characteristics (4) Identification of the time interval beginning with initiation of an accident to as long as the measurement is needed (5) Identification of the local environment (including energy supply) in which the various instrumentation components are required to operate.(7) Section 6.1.1 of ANS-4.5, pertains to seismic qualification criteria.In conjunction with Section 6.1.1, those instrumentation components which should be seismically qualified are identified in Table 1 of this regulatory guide.(8) Section 6.1.1 of ANS-4.5, pertains, in part, to the consideration of vibrational loads. TIn conjunction with Section 6.1.1, those instrumentation 1.97-8 components which are subjected to vibrational loads that occur as a result of plant system operation during any phase for which the instrumentation is required should be qualified to function during and/or following such vibrational loads.(9) Section 6.1.2 of ANS-4.5, pertains to the duration that instrumentation is qualified to function.
 
In conjunction with Section 6.1.2, Phase II instrumen-tation should be qualified to function for not less than 200 days unless a shorter time, based on need or component accessability for replacement or repair, can be justified.
Consideration should be given to the additional requirements (e.g., emergency planning) of variables to be monitored by the plant operator (licensee) during and following an accident. Instrumentation selected for use by the plant opera-tor for monitoring conditions of the plant are useful in an emergency situation and for other purposes and therefore should be factored into the emergency plans action level criteria.
(10) Section 6.1.6 of ANS-4.5 pertains to instrumentation location and identification.
(2) In Section 3.0 of ANS-4.5, the definition of "Type C" includes two items, (1) and (2). Item (1) includes those instruments that indicate the extent to which parameters, which indicate the potential for a breach in the containment, have exceeded the design basis values. In conjunction with the parameters that indicate the potential for a breach in the containment, the parameters that have the potential for causing a breach in the fuel cladding (e.g., core exit temperature) and the reactor coolant pressure boundary (e.g.,
In conjunction with Section 6.1.6, accident monitoring instru-mentation displays should be located in direct view of the plant operator and be distinguished from other displays.
reactor coolant pressure) should also be included. References to Type C instru-ments, and associated parameters to be measured, in Draft Standard ANS-4.5 should include this expanded definition, e.g., Section 4.2, Section 5.0c, Section 5.1.3, Section 5.2.2, Section 6.3.
Other accident monitoring instrumentation components should be accessible to the plant operator for maintenance and repair although this may not be possible for some components in some accident conditions.
(3) Section 3.0 of ANS-4.5 defines design basis accident events. In conjunction with the design basis accident events delineated in the standard, those events which are expected to occur one or more times during the life of a nuclear power unit and include but are not limited to loss of power to all recirculating pumps, tripping of the turbine generator set, isolation of the main condenser, and loss of all offsite power, should be included.
(11) Section 6.2.1 of ANS-4.5 pertains to general requirements for Type B instruments.
(4) Section 4.2 of ANS-4.5, discusses the various types of variables.
In conjunction with Section 6.2.1, Type B instruments are essen-tial to meeting the requirements of Criterion 13 and Criterion 64 of Appendix A to 10 CFR Part 50 and are not considered to be an "extra set of instruments which result in an additional layer of protection." Type B instruments are essential to the monitoring of variables and systems during accident conditions and in following the course of an accident.(12) Section 6.2.2, 6.2.3, 6.2.4, 6.2.5, 6.2.6, 6.3.2, 6.3.3, 6.3.4, and 6.3.5 of ANS-4.5 pertain to variables and variable ranges for monitoring.
With regard to the discussion of Type D variables, Type 0 variables and instru-ments are within the scope of Accident Monitoring Instrumentation, although 1.97-7
In conjunction with the above sections, Tables 1, 2 and 3 of this regulatory guide (which includes those parameters mentioned in the above sections) should be used in developing the minimum set of instruments and their respective ranges for accident monitoring instrumentation for each nuclear power plant.1.97-9 (13) Sections 6.3.2.3, 6.3.3.3, 6.3.3.4, 6.3.4.3, 6.3.4.4, 6.3.5.2, 6.3.5.3, and 6.3.5.4 of ANS-4.5 pertain, in part, to instrument transient response and relate this to compatability with recorder capabilities.
 
In conjunction with the above sections, the transient response requirements of each measurement should be determined on a case-by-case basis by analysis of the event and operator response capabilities.
they are not addressed in Oraft Standard ANS-4.5. They are, however, along with an additional type, Type E, included in this regulatory guide.   (See Tables 1, 2 and 3)
(14) Sections 6.3.3.3, 6.3.3.4, and 6.3.4.3 of ANS-4.5, pertain, in part, to measurement accuracy.
(5) Section 5.2.1(5) of ANS-4.5 pertains to the delineation of the local environment in which instruments must operate. Section 5.2.1(5) should be understood to require identification of the range of the local physical and electrical environments (e.g., normal, abnormal, accident, and post-accident) in which all of the various instrumentation components are required to operate (e.g., sensors, cables, signal conditioning equipment, indicators).
In conjunction with the above sections, the accuracy of each measurement should be consistent with the requirements as established by analysis of the event being monitored.
(6) Section 5.2.2 of ANS-4.5 pertains to the performance requirements for Type C instrumentation. In conjunction with Section 5.2.2, there should be:.
(15) Section 6.3.6.1.1 ANS-4.5 pertains, in part, to the qualification of Type C instrumentation components.
(1) Identification of the range of the process variable.     (Note -
In conjunction with Section 6.3.6.1.1, the environmental envelope for qualification should be the extreme value of each environmental parameter, except the variable being monitored, as determined by the accident analysis for all accidents evaluated in the safety analysis of the plant.(16) Table 6.4.1 of ANS-4.5 pertains to design criteria for accident monitoring instrumentation.
the range selected should extend well beyond that which the variable value can attain under limiting conditions)
In conjunction with Table 6.4.1, the provisions as indicated in Table 1 of this regulatory guide should be used.D. IMPLEMENTATION This proposed revision has been released to encourage public participation in its development.
(2) Identification of the required accuracy of measurement (3) Identification of the required response characteristics (4) Identification of the time interval beginning with initiation of an accident to as long as the measurement is needed (5) Identification of the local environment (including energy supply) in which the various instrumentation components are required to operate.
Except in those cases in which an applicant proposes an acceptable alternative method for complying with specified portions of the Commission's regulations, the method to be described in the active guide reflect-ing public comments will be used in the evaluation of the following applica-tions that are docketed after the implementation date to be specified in the guide: 1. 97-10  
(7) Section 6.1.1 of ANS-4.5, pertains to seismic qualification criteria.
*0 P 1. Preliminary Design Approval (PDA) applications and Preliminary Duplicate Design Approval (PDA) applications.
In conjunction with Section 6.1.1, those instrumentation components which should be seismically qualified are identified in Table 1 of this regulatory guide.
(8) Section 6.1.1 of ANS-4.5, pertains, in part, to the consideration of vibrational loads. TIn conjunction with Section 6.1.1, those instrumentation 1.97-8
 
components which are subjected to vibrational loads that occur as a result of plant system operation during any phase for which the instrumentation is required should be qualified to function during and/or following such vibrational loads.
(9) Section 6.1.2 of ANS-4.5, pertains to the duration that instrumentation is qualified to function. In conjunction with Section 6.1.2, Phase II instrumen-tation should be qualified to function for not less than 200 days unless a shorter time, based on need or component accessability for replacement or repair, can be justified.
(10) Section 6.1.6 of ANS-4.5 pertains to instrumentation location and identification. In conjunction with Section 6.1.6, accident monitoring instru-mentation displays should be located in direct view of the plant operator and be distinguished from other displays. Other accident monitoring instrumentation components should be accessible to the plant operator for maintenance and repair although this may not be possible for some components in some accident conditions.
(11) Section 6.2.1 of ANS-4.5 pertains to general requirements for Type B instruments. In conjunction with Section 6.2.1, Type B instruments are essen-tial to meeting the requirements of Criterion 13 and Criterion 64 of Appendix A to 10 CFR Part 50 and are not considered to be an "extra set of instruments which result in an additional layer of protection."     Type B instruments are essential to the monitoring of variables and systems during accident conditions and in following the course of an accident.
(12) Section 6.2.2, 6.2.3, 6.2.4, 6.2.5, 6.2.6, 6.3.2, 6.3.3, 6.3.4, and 6.3.5 of ANS-4.5 pertain to variables and variable ranges for monitoring. In conjunction with the above sections, Tables 1, 2 and 3 of this regulatory guide (which includes those parameters mentioned in the above sections) should be used in developing the minimum set of instruments and their respective ranges for accident monitoring instrumentation for each nuclear power plant.
1.97-9
 
(13) Sections 6.3.2.3, 6.3.3.3, 6.3.3.4, 6.3.4.3, 6.3.4.4, 6.3.5.2, 6.3.5.3, and 6.3.5.4 of ANS-4.5 pertain, in part, to instrument transient response and relate this to compatability with recorder capabilities.     In conjunction with the above sections, the transient response requirements of each measurement should be determined on a case-by-case basis by analysis of the event and operator response capabilities.
(14) Sections 6.3.3.3, 6.3.3.4, and 6.3.4.3 of ANS-4.5, pertain, in part, to measurement accuracy. In conjunction with the above sections, the accuracy of each measurement should be consistent with the requirements as established by analysis of the event being monitored.
(15)   Section 6.3.6.1.1 ANS-4.5 pertains, in part, to the qualification of Type C instrumentation components.     In conjunction with Section 6.3.6.1.1, the environmental envelope for qualification should be the extreme value of each environmental parameter, except the variable being monitored, as determined by the accident analysis for all accidents evaluated in the safety analysis of the plant.
(16) Table 6.4.1 of ANS-4.5 pertains to design criteria for accident monitoring instrumentation. In conjunction with Table 6.4.1, the provisions as indicated in Table 1 of this regulatory guide should be used.
D. IMPLEMENTATION This proposed revision has been released to encourage public participation in its development. Except in those cases in which an applicant proposes an acceptable alternative method for complying with specified portions of the Commission's regulations, the method to be described in the active guide reflect-ing public comments will be used in the evaluation of the following applica-tions that are docketed after the implementation date to be specified in the guide:
: 1. 97-10
 
                      *0                         P
: 1. Preliminary Design Approval (PDA) applications and Preliminary Duplicate Design Approval (PDA) applications.
: 2. Final Design Approval, Type 2 (FDA-2), applications and Final Duplicate Design Approval, Type 2 (FDDA-2), applications.
: 2. Final Design Approval, Type 2 (FDA-2), applications and Final Duplicate Design Approval, Type 2 (FDDA-2), applications.
: 3. Manufacturing License (ML) applications.
: 3. Manufacturing License (ML) applications.
: 4. Construction Permit (CP) applications except for those portions of CP applications that reference standard designs (i.e., PDA, FDA-1, FDA-2, PDDA, FDDA-1, FDDA-2, or ML) or that reference qualified base plant designs under the replication option.In addition, the NRC staff intends to implement part or all of this guide for all operating plants, plants under construction, all PDA's and FDA's, all PDDA's and all FDDA's which may involve additions, elimination, or modification of structures, systems, or components of the facility after the construction permit, or design approval has been issued. All backfitting decisions in accordance with the positions stated in this guide will be determined by the staff on a case-by-case basis.The implementation date of this guide will in no case be earlier than 1. 97-11
: 4. Construction Permit (CP) applications except for those portions of CP applications that reference standard designs (i.e., PDA, FDA-1, FDA-2, PDDA, FDDA-1, FDDA-2, or ML) or that reference qualified base plant designs under the replication option.
* TABLE 1 -DESIGN CRITERIA' 0 INSTRUMENTATION TYPES 2 CRITERIA A 1. Seismic Qualification per Reg Guide 1.100 2. Single Failure Criteria per Reg Guide 1.53 3. Environmental Qualification per Reg Guide 1.89 4. Consider loss of off-site power 5. Power source 6. Out of service interval before accident 7. Portable 8. Quality assurance level 9. Display type 1 2 10. Display method 11. Unique identification
In addition, the NRC staff intends to implement part or all of this guide for all operating plants, plants under construction, all PDA's and FDA's, all PDDA's and all FDDA's which may involve additions, elimination, or modification of structures, systems, or components of the facility after the construction permit, or design approval has been issued. All backfitting decisions in accordance with the positions stated in this guide will be determined by the staff on a case-by-case basis.
: 12. Periodic testing per Reg Guide 1.118 NOTES for Table 1: (1) Unless guide, Specif Instru monito efflue for me yes yes yes yes Emr 5 7 no 11 Con 1 3 Rec 1 5 yes yes B yes yes yes yes CB 6 7 no 11 Con 1 3 Rec1 6 yes yes C yes yes yes 3 yes CB 6 7 no 1 0 1 1 Con 1 3 Rec 1 6 yes yes D no no yes yes Emr 5 8 no 1 0 11 OD14 Ind 1 7 no yes E no no no4 yes Emrs 13 nolo 11 OD14.Ind7, 18 no no different specifications are given in this regulatory the specifications in ANSI N320-1979, "Performance
The implementation date of this guide will in no case be earlier than
'ications for Reactor Emergency Radiological Monitoring mentation," apply to the high-range containment area rs, area exposure rate monitors in other buildings, ent and environmental monitors, and portable instruments asuring radiation or radioactivity.
: 1. 97-11
(2) Type A -Those instruments which provide information required to take pre-planned manual actions.Type B -Those instruments which provide information to monitor the process of accomplishing critical safety functions.
* TABLE   1 - DESIGN CRITERIA'         0 CRITERIA                                        INSTRUMENTATION TYPES 2 A           B        C          D E
Type C -Those instruments that indicate the potential for breach-ing or the actual breach of the barriers to fission pro-duct release.Type D -Those instruments that indicate the performance of in-dividual safety systems.Type E -Those instruments that provide information for defense-in-depth and for diagnosis or other useful purposes.1.97-12 0 NOTES for Table 1 continued:
: 1. Seismic Qualification               yes        yes        yes        no per Reg Guide 1.100                                                         no
(3) -See Paragraph 6.3.6 of Draft Standard ANS-4.5.(4) Qualified to the conditions of fts operation.(s) Emergency power source.(6) Critical Instrument Buss -Class 1E Power.(7) IEEE 279-1971 Paragraph 4.11, "Exemption".
: 2. Single Failure Criteria             yes        yes        yes        no per Reg Guide 1.53                                                           no
(8) Based on normal tech spec requirements on out-of-service for the safety system it serves.(9) Not necessary to include in tech specs.(10) Radiation monitoring outside containment may be portable if as designated.
: 3. Environmental Qualification         yes        yes        yes3      yes per Reg Guide 1.89                                                           no4
(11) Level of quality assurance per 10 CFR Part 50, Appendix B.(12) Continuous indication or recording displays a given variable at all times; intermittent indi-cation or recording displays a given variable periodically; on demand indication or recording displays a given variable only when requested.
: 4. Consider loss of off-site           yes          yes        yes      yes    yes power
13 ) Continuous display.(14) Indication on demand.(15) Where trend or transient information is essential to planned operator actions.(16) Recording.
: 5. Power source                         Emr5        CB6        CB6        Emr 5 Emrs
(1?) Dial or digital indication.
: 6. Out of service interval               7            7        7 before accident                                                         8      13
CIS) Effluent release monitors require recording, in-cluding effluent radioactivity monitors, environs exposure rate monito-rs, and meteorology monitors.1.97-13 TABLE 2 -P':!R VIARIABLES Measured Variable CORE: Core Exit Temperature Control Rod Position Neutron Flux REACTOR COOLANT SYSTEM: RCS Hot Leg Temper-ature RCS Cold Leg Temper-ature RCS Pressure Pressurizer Level Degree of Subcooling
: 7. Portable                             no          no          no10      no10  nolo
; -- § Buy- ! r puz 150 0 F to 2300aF Full in in or not full 1 c/s to 1% power (at least one fission counter)150 0 F to 750aF 130*F to 750 0 F 15 psia to 4000 psig Bottom tangent to top tangent 200OF subcooiing to 3 5 0 F superheat B,C D E B BC B,D ANS-4.5, Section 6.2.3 Provide incore temperature measurements to identify localized hot areas.(Approximately 50 measurements)
: 8. Quality assurance level             11          11        11        11    11
Provide positive indication that the con-trol rods are fully inserted.(Minimum 5 days after accident)ANS-4.5, Section 6.2.2 For indication of approach to criticality.
: 9. Display type 12                    Con 13      Con 13      Con 13    OD14  OD14.
ANS-4.5, Section 6.2.3 To aid in determining reactor system sub-cooling and to provide indication of natural circulation.
: 10. Display method                     Rec 15      Rec1 6      Rec 1 6    Ind17 Ind7, 18
ANS-4.5, Section 6.2.3 To provide indication of natural circula-tion; to provide input for heat balance calculations; for direct indication of ECCS injection.
: 11. Unique identification               yes          yes        yes        no    no
AVNS-4.5, Sections 6.2.3 and 6.2.4 For indication of an accident and to in-dicate that actions must be taken to mitigate an event.ANS-4.5, Section 6.2.3 Level indication is required to assure proper operation of the pressurizer and to assure safe operation of heaters. It is also used in conjunction with changes in reactor pressure to determine leak and void sizes.For indication of margin in core cooling and the need for emergency coolant addi-tions or reductions as the margin changes and to obviate the necessity to consuit steam tables.1.97-14 0 Tvne I Rance D. *t -
: 12. Periodic testing per               yes          yes        yes        yes    no Reg Guide 1.118 NOTES for Table 1:   (1) Unless different specifications are given in this regulatory guide, the specifications in ANSI N320-1979, "Performance Specif 'ications for Reactor Emergency Radiological Monitoring Instru mentation," apply to the high-range containment area monito rs, area exposure rate monitors in other buildings, efflueent and environmental monitors, and portable instruments for measuring radiation or radioactivity.
TABLE 2 -PWR VARIABLES continued
(2)  Type A  - Those instruments which provide information required to take pre-planned manual actions.
-Measured Variable REACTOR COOLANT SYSTEM CONTINUED:
Type B - Those instruments which provide information to monitor the process of accomplishing critical safety functions.
Reactor Flow Coolant Loop Primary System Safety Relief Valve Posi-tions or Flow Through or Pressure In Relief Valve Lines Radiation Level in Primary Coolant Watei CONTAINMENT:
Type C - Those instruments that indicate the potential for breach-ing or the actual breach of the barriers to fission pro-duct release.
Containment Pressure Containment Atmos-phere Temperature Containment Hydrogen Concentration Containment Isola-tion Valve Position Range--1 e P urwnw 0 to 120%]] des-20% to 20%J' flogw Closed-not closed 10 uCi/g to 10 Ci/g 10 psia pressure to 3 times design press-ure 2 for concrete; 4.times design pressure for steel 40*F to 400*F 0 to 10%(capable from 10 I maximum c ure 2 of operating Dsia to design press-Closed-not closed B,D B,D C B,C E B,C B,D To provide indication being cooled.that the core is By these measurements the operator knows if there is a path open for loss of cool-ant and that an event may be in progress.ANS-4.5, Section 6.3.2 For early indication of fuel cladding failure and estimate of extent of damage.ANS-4.5, Sections 6.2.5, 6.3.3, 6.3.4, and 6.3.5 For indication of the integrity of the primary or secondary system pressure boundaries.
Type D - Those instruments that indicate the performance of in-dividual safety systems.
To indicate the potential for leakage from the containment; to indicate integrity of the containment.
Type E - Those instruments that provide information for defense-in-depth and for diagnosis or other useful purposes.
For indication of the performance of the containment cooling system and adequate mixing.ANS-4.5, Sections 6.2.5 and 6.3.5 For indication of the need, and to meas-ure the performance of the containment hydrogen recombiner.
1.97-12
ANS-4.5, Section 6.2.3 To indicate the status of containment isolation and to provide information on the status of valves in process lines which could carry radioactive materials out of containment.
 
: 1. 97-15 Type Piirnnose TABLE 2 -PWR VARIABLES continued
0 NOTES for Table 1 continued:    (3) -See Paragraph 6.3.6 of Draft Standard ANS-4.5.
-Measured Variable CONTAINMENT CONTINUED:
(4)  Qualified to the conditions of fts operation.
Containment Sump Water Level High Range Contain-ment Area Radiation SECONDARY SYSTEMiS: Steam Generator Pressure Steam Generator Level Auxiliary Flow Feedwater Main Feedwater Flow Safety/Relief Valve Positions or Main Steam Flow Radiation in Condenser Air Removal System Radioactivity in Efflu-ent from Steam Gener-ator Safety Relief Valves or Atmospheric Dump Valves Range Narrow range (sump)Wide range (bottom of containment to 600,000 gallon level equiva-lent)1 to 107 R/hr (60 keV to 3 MeV photons with +20% accuracy for photons of 0.1 to 3 MeV)[107 R/hr for pho-tons is approximately equivalent to 108 rads per hour for betas and photons]From pressure for safety valve setting to plus 20% of safety valve setting From tube sheet separators to 0 to 110% design flow 1 0 to 110% design flow 1 Closed-not closed 10-7 to 105 Ci/cc 10-7 to lo05 ;1Ci/cc I Type BC B,C D D D E B,D B,C , r To indicate leakage from the primary to the secondary system and measure of noble gas release rate to atmosphere.
(s) Emergency power source.
An indication of release from the secondary system and measure of noble gas release rate to atmosphere.
(6) Critical Instrument Buss - Class 1E Power.
1.97-16 For indication of leakage within the containment and to assure adequate in-ventory for performance of the ECCS.For implementation of GDC 64 and to help identify if an accident has degraded be-yond calculated values and to indicate its magnitude to determine action to protect the public.For indication of integrity of the sec-ondary system, and an indication of cap-ability for decay heat removal.For indication of. integrity of the sec-ondary system, and an indication of cap-ability for decay heat removal.To indicate an adequate source of water to each steam generator upon loss of main feedwater.
(7)  IEEE 279-1971 Paragraph 4.11, "Exemption".
To indicate an adequate source of water to each steam generator.
(8) Based on normal tech spec requirements on out-of-service for the safety system it serves.
To Indicate integrity of secondary system (vis--a-vis pipe break).I Type Puroose TABLE 2 -POR VARIABLES con Olued -Measured Variable AUXILIARY SYSTEMS: Containment Spray Flow Flow in HPI System Flow in LPI System Emergency Coolant Water Storage Tank Level Accumulator Tank Level Accumulator Isolation Valve Positions RHR System Flow RER Heat Exchanger Out Temperature Component Cooling Water Temperature Component Cooling Water Flow Flow in UHS Loop Temperature in Ulti-mate Heat Sink Loop Ultimate Heat Sink Level Eeat Removal by the Containment Fan Coolers Boric Acid Charging Flow Range O to 110% design flow 2 0 to 110% design flow'0 to 110% design flow 1 Top to bottom Top to bottom Closed-not closed 0 to 110% design flow 1 32 0 F to 350 0 F 32 0 F to 200*F 0 to 110% design flow 1 0 to 110% design flow 1 30°F to 150 0 F Plant specific Plant specific 0 to 110% design flow 1 T ; ;I;o -D D D D D D D D D D D D D B B For indication of system operation.
(9) Not necessary to include in tech specs.
For indication of system operation.
(10) Radiation monitoring outside containment may be portable if as designated.
For indication of system operation.
(11)   Level of quality assurance per 10 CFR Part 50, Appendix B.
To determine the amount of water dis-charged by the ECCS. This provides in-dication of the nature of the accident, indication of the performance of the ECCS, and indication of the necessity for operator action.To indicate whether the tanks have in-jected to the reactor coolant system.To indicate state of the isolation valves. (Per Regulatory Guide 1.47)For indication of system operation.
(12)   Continuous indication or recording displays a given variable at all times; intermittent indi-cation or recording displays a given variable periodically; on demand indication or recording displays a given variable only when requested.
For indication of system operation.
13 ) Continuous display.
For indication of system ope.ration For indication of system operation.
(14)   Indication on demand.
For indication of system operation.
(15)   Where trend or transient information is essential to planned operator actions.
For indication of system operation.
(16)  Recording.
To ensure adequate water.source of cooling to indicate system operation To provide indication of reactor cooling and inventory control and maintain ade-quate concentration for shutdown margin.1.97-17.Type Purcose S TABLE 2 -PWR VARIABLES continued
(1?)  Dial or digital indication.
-Measured Variable Ranqe I --_ _ -f I -. --~W41 0 AUXILIARY SYSTEMS CONTINUED:
CIS)  Effluent release monitors require recording, in-cluding effluent radioactivity monitors, environs exposure rate monito-rs, and meteorology monitors.
Letdown Flow Sump Level in Spaces of Equipment Required for Safety RADWASTE SYSTEMS: High Level Radioactive Liquid Tank Level Radioactive Gas Hold-up Tank Pressure VENTILATION SYSTEMS: Emergency Ventilation Damper Position Temperature of Space in Vicinity of Equip-ment Required for Safety POWER SUPPLIES: Status of Class IE Power Supplies and Systems Status of Non-Class lE Power Supplies and Systems 0 to 110% design flowl To corresponding level of safety equipment failure Top to bottom 0 to 150% of design pressure 2 Open-closed status 30 0 F to 180°F Voltages and currents Voltages and currents D D E D D D K For indication of reactor coolant inven-tory control and boron concentration control.To monitor environmental conditions of equipment in closed spaces.Available volume to store primary coolant-Available capacity to store waste gases.To ensure proper ventilation under accident conditions.
1.97-13
To monitor environmental conditions of equipment in closed spaces.To ensure an adequate source power for safety systems.of electric It indicate an adequate source of elec-tric power.1.97-18 Tvop Plirmnen TABLE 2 -PWR VARIABLES continued
 
-Measured Variable RADIATION EXPOSURE RATES INSIDE BUILDINGS OR AREAS WHERE ACCESS IS REQUIRED TO SERVICE SAFET7 RELATED EQUIPMENT Radiation Exposure Rates Ranqe 10-1 to 104 R/hr for photons (permanently install-ed monitors)AIRBORNE RADIOACTIVE MAT.ERIALS RELEASED FROM THE PLANT: Effluent Radioactiv-ity -Noble Gases-Containment-Secondary Contain-ment-Auxiliary Building including building containing primary system gases, eg.waste gas decay tank.Other Release Points (including fuel handling area if separage from auxiliary building Effluent Radioactiv-ity -High Range Radiohalogens and Particulates-Untreated Effluents.HEPA Filters, min-imum of 2" of TEDA impregnated char-coal, non-ESF sys-tems.HEPA Filters, min-imuni of 4" of TEDA impregnated char-coal, ESF systems (Normal plus accident range for noble gas)-7 to 105 .Ci/cc Xe-133 calibration 10-7 to 104 11Ci/cc Xe-133 calibration 10-7 to 103 uCi/cc 10-7 to 102 vICi/cc (permanently install-ed monitors)10-3 to 102 4Ci/cc'0-3 to 10 .Ci/cc 10-3 to 1 .Ci/cc (permanently install-ed monitors)I I T v o- e I ma -P For measurement of high-range radiation exposure rates at various locations.
TABLE 2 - P':!R VIARIABLES 0
ANS-4.5 Section 6.2.6 To provide operator with information regarding release of radioactive noble gases on a continuous basis.To provide the operator with information regarding release of radioactive halogens and particulates.
Measured Variable                  Rance                Tvne  I                    D. *t    -
Continuous collection of representative samples followed by monitoring (measurements) of samples for radiohalogens and for particulates.
                          ;              --            §  Buy-  !                  r    puz CORE:
: 1. 97-19..Tvoe Piirnmca TABLE 2 -PWR VARIABLES con*ued -Measured Variable I _ _ __ _ __I _ _ _ ,, A- I
Core Exit Temperature      150 0 F to 2300aF            B,C      ANS-4.5, Section 6.2.3 Provide incore temperature measurements to identify localized hot areas.
(Approximately 50 measurements)
Control Rod Position     Full in or not full          D        Provide positive indication that the con-in                                    trol rods are fully inserted.
(Minimum 5 days after accident)
Neutron Flux              1 c/s to 1% power             E        ANS-4.5, Section 6.2.2 (at least one fission                 For indication of approach to criticality.
counter)
REACTOR COOLANT SYSTEM:
RCS Hot Leg Temper-      150 0 F to 750aF                     ANS-4.5, Section 6.2.3 ature                                                            To aid in determining reactor system sub-cooling and to provide indication of natural circulation.
RCS Cold Leg Temper-     130*F to 7500 F              B      ANS-4.5, Section 6.2.3 ature To provide indication of natural circula-tion; to provide input for heat balance calculations; for direct indication of ECCS injection.
RCS Pressure              15 psia to 4000 psig          BC      AVNS-4.5, Sections 6.2.3 and 6.2.4 For indication of an accident and to in-dicate that actions must be taken to mitigate an event.
Pressurizer Level        Bottom tangent to              B,D    ANS-4.5, Section 6.2.3 top tangent                          Level indication is required to assure proper operation of the pressurizer and to assure safe operation of heaters. It is also used in conjunction with changes in reactor pressure to determine leak and void sizes.
Degree of Subcooling      200OF subcooiing to                  For indication of margin in core cooling 3 50 F superheat                      and the need for emergency coolant addi-tions or reductions as the margin changes and to obviate the necessity to consuit steam tables.
1.97-14
 
TABLE 2 - PWR VARIABLES continued -
Measured Variable                Range              Typee                    Piirnnose
                          --              1                                    P urwnw REACTOR COOLANT SYSTEM CONTINUED:
Reactor Coolant Loop      0 to 120%)) des          B,D  To provide indication that the core is Flow                    -20% to 20%J'    flogw          being cooled.
Primary System Safety    Closed-not closed          B,D  By these measurements the operator knows Relief Valve Posi-                                         if there is a path open for loss of cool-tions or Flow Through                                    ant and that an event may be in progress.
or Pressure In Relief Valve Lines Radiation Level in        10 uCi/g  to 10 Ci/g      C    ANS-4.5, Section 6.3.2 Primary Coolant Watei                                      For early indication of fuel cladding failure and estimate of extent of damage.
CONTAINMENT:
Containment Pressure      10 psia pressure to      B,C    ANS-4.5, Sections 6.2.5, 6.3.3, 6.3.4, 3 times design press-           and 6.3.5 ure 2 for concrete; 4.          For indication of the integrity of the times design pressure            primary or secondary system pressure for steel                        boundaries. To indicate the potential for leakage from the containment; to indicate integrity of the containment.
Containment Atmos-        40*F to 400*F            E      For indication of the performance of the phere Temperature                                          containment cooling system and adequate mixing.
Containment Hydrogen      0 to 10%                 B,C  ANS-4.5, Sections 6.2.5 and 6.3.5 Concentration            (capable of operating           For indication of the need, and to meas-from 10 IDsia to                ure the performance of the containment maximum cdesign press-         hydrogen recombiner.
ure 2 Containment Isola-        Closed-not closed         B,D   ANS-4.5, Section 6.2.3 tion Valve Position                                      To indicate the status of containment isolation and to provide information on the status of valves in process lines which could carry radioactive materials out of containment.
1.97-15
 
TABLE 2 - PWR VARIABLES continued    -
Measured Variable              Range I Type I
r Type Puroose CONTAINMENT CONTINUED:
Containment Sump        Narrow range (sump)        BC  For indication of leakage within the Water Level              Wide range (bottom of           containment and to assure adequate in-containment to 600,000          ventory for performance of the ECCS.
gallon level equiva-lent)
High Range Contain-     1 to 107 R/hr (60 keV      B,C  For implementation of GDC 64 and to help ment Area Radiation      to 3 MeV photons                identify if an accident has degraded be-with +20% accuracy for          yond calculated values and to indicate photons of 0.1 to 3            its magnitude to determine action to MeV)[107 R/hr for pho-           protect the public.
tons is approximately equivalent to 108 rads per hour for betas and photons]
SECONDARY SYSTEMiS:
Steam Generator        From pressure for          D    For indication of integrity of the sec-Pressure               safety valve setting            ondary system, and an indication of cap-to plus 20% of safety          ability for decay heat removal.
valve setting Steam Generator Level  From tube sheet to        D    For indication of. integrity of the sec-separators                      ondary system, and an indication of cap-ability for decay heat removal.
Auxiliary Feedwater      0 to 110% design flow1    D    To indicate an adequate source of water Flow                                                    to each steam generator upon loss of main feedwater.
Main Feedwater Flow      0 to 110% design flow 1        To indicate an adequate source of water E
to each steam generator.
Safety/Relief Valve      Closed-not closed         B,D To Indicate integrity of secondary Positions or Main                                        system (vis--a-vis pipe break).
Steam Flow Radiation in Condenser    10-7 to 105  Ci/cc Air Removal System                                        To indicate leakage from the primary to the secondary system and measure of noble gas release rate to atmosphere.
Radioactivity in Efflu-  10-7 to lo05 ;1Ci/cc      B,C  An indication of release from the ent from Steam Gener-secondary system and measure of noble ator Safety Relief Valves or Atmospheric                                    gas release rate to atmosphere.
Dump Valves 1.97-16
 
TABLE 2 - POR VARIABLES con Olued -                           .
Measured Variable              Range            Type                  Purcose-
                            ;                    ;I;o T
AUXILIARY SYSTEMS:
Containment Spray      O to 110% design flow2          For indication of system operation.
D Flow Flow in HPI System    0 to 110% design flow'          For indication of system operation.
D Flow in LPI System      0 to 110% design flow1          For indication of system operation.
D Emergency Coolant      Top to bottom                  To determine the amount of water dis-Water Storage Tank                                D charged by the ECCS. This provides in-Level                                                  dication of the nature of the accident, indication of the performance of the ECCS, and indication of the necessity for operator action.
Accumulator Tank        Top to bottom                  To indicate whether the tanks have in-Level                                              D jected to the reactor coolant system.
Accumulator Isolation  Closed-not closed              To indicate state of the isolation Valve Positions                                    D valves. (Per Regulatory Guide 1.47)
RHR System Flow         0 to 110% design flow1          For indication of system operation.
D RER Heat Exchanger     320 F to 3500 F                For indication of system operation.
D Out Temperature Component Cooling       320 F to 200*F                  For indication of system ope.ration D
Water Temperature Component Cooling       0 to 110% design flow1          For indication of system operation.
D Water Flow Flow in UHS Loop       0 to 110% design flow1          For indication of system operation.
D Temperature in Ulti-    30°F to 1500 F                  For indication of system operation.
D mate Heat Sink Loop Ultimate Heat Sink     Plant specific            D    To ensure adequate source of cooling Level                                                  water.
Eeat Removal by the     Plant specific                  to indicate system operation B
Containment Fan Coolers Boric Acid Charging     0 to 110% design flow1    B    To provide indication of reactor cooling Flow                                                    and inventory control and maintain ade-quate concentration for shutdown margin.
1.97-17
 
TABLE 2 -
S PWR VARIABLES continued    -
0 Measured Variable                Ranqe            Tvop                    Plirmnen
_ _      -          fI  --  I                  - -.- ~W41 AUXILIARY SYSTEMS CONTINUED:
Letdown Flow            0 to 110% design flowl        D    For indication of reactor coolant inven-tory control and boron concentration control.
Sump Level in Spaces    To corresponding level            To monitor environmental conditions of of Equipment Required                                D of safety equipment                equipment in closed spaces.
for Safety              failure RADWASTE SYSTEMS:
High Level Radioactive Top to bottom                      Available volume to store primary coolant-Liquid Tank Level                                    E Radioactive Gas Hold-   0 to 150% of design              Available capacity to store waste gases.
up Tank Pressure        pressure 2 VENTILATION SYSTEMS:
Emergency Ventilation  Open-closed status          D      To ensure proper ventilation under Damper Position                                            accident conditions.
Temperature of Space    300 F to 180°F              D      To monitor environmental conditions of in Vicinity of Equip-                                      equipment in closed spaces.
ment Required for Safety POWER SUPPLIES:
Status of Class IE      Voltages and currents      D      To ensure an adequate source of electric Power Supplies and                                          power for safety systems.
Systems Status of Non-Class      Voltages and currents                indicate an adequate source of elec-K      It lE Power Supplies                                          tric power.
and Systems 1.97-18
 
TABLE 2 - PWR VARIABLES continued -                                 .
Measured Variable                   Ranqe I                         I Tvoe T v o-e Piirnmca I ma -P RADIATION EXPOSURE RATES INSIDE BUILDINGS OR AREAS WHERE ACCESS IS REQUIRED TO SERVICE SAFET7 RELATED EQUIPMENT Radiation Exposure          10-1 to 104 R/hr for              For measurement of high-range radiation Rates                      photons                          exposure rates at various locations.
(permanently install-ed monitors)
AIRBORNE RADIOACTIVE MAT.
ERIALS RELEASED FROM THE PLANT:
Effluent Radioactiv-        (Normal plus accident            ANS-4.5 Section 6.2.6 ity - Noble Gases          range for noble gas)              To provide operator with information
        -Containment            -7 to 105 .Ci/cc                regarding release of radioactive noble Xe-133 calibration              gases on a continuous basis.
        -Secondary Contain-    10-7 to 104 11Ci/cc ment                    Xe-133 calibration
        -Auxiliary Building    10-7 to 103 uCi/cc including building containing primary system gases, eg.
waste gas decay tank
        .Other Release        10-7 to 102 vICi/cc Points (including fuel handling area    (permanently install-if separage from      ed monitors) auxiliary building Effluent Radioactiv-                                         To provide the operator with information ity - High Range                                              regarding release of radioactive halogens Radiohalogens and and particulates. Continuous collection Particulates of representative samples followed by
    -Untreated Effluents      10-3 to 102 4Ci/cc                monitoring (measurements) of samples for radiohalogens and for particulates.
    .HEPA Filters, min-       '0-3 to 10    .Ci/cc imum of 2" of TEDA impregnated char-coal, non-ESF sys-tems
    .HEPA Filters, min-     10-3 to 1    .Ci/cc imuni of 4" of TEDA impregnated char-      (permanently install-coal, ESF systems      ed monitors) 1.97-19
 
TABLE 2 - PWR VARIABLES con*ued -
Measured Variable                  Rance_          I Tvn0a
* oe I   _   _ __     __I _ _ _ ,, A- I
* u I uz e AIRBORNE RADIOACTIVE MAT-ERIALS RELEASED FROM THE PLANT CONTINUED:
* u I uz e AIRBORNE RADIOACTIVE MAT-ERIALS RELEASED FROM THE PLANT CONTINUED:
Environs Radioactiv-ity -High Range Exposure Rate Environs Radioactiv-ity -Radiohalogens and Particulates AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM THE PLANT CONTINUED:
Environs Radioactiv-    lO3 to 102 R/hr                    For estimating release rates of radio-ity - High Range         (60 keV to 3 MeV)                  active materials released during an Exposure Rate                                                 accident from unidentified release paths (permanently install-ed monitors)                        (not covered by effluent monitors) -
Plant and Environs Radioactivity (portable instruments lO3 to 102 R/hr (60 keV to 3 MeV)(permanently install-ed monitors)10-9 to 10-3 4Ci/cc for both radiohalogens and particulates (permanently install-ed monitors)Normal Range 0.1 to 104 mR/hr photons 10-9 to O14 4C4/cc particulates 10-9 to 10-4 UCi/cc iodine High Range 0.1 to 104 R/hr photo-as 0.1 to 104 rads/hr betas and low energy photons lO-channel gamra-ray spectrometer E For estimating release rates of radio-active materials released during an accident from unidentified release paths (not covered by effluent monitors)
continuous readout capability, approxi-mately 16 to 20 locations - site de-pendent.
-continuous readout capability, approxi-mately 16 to 20 locations
Environs Radioactiv-      10-9 to 10-3 4Ci/cc         E      For estimating releases rates of radio ity - Radiohalogens      for both radiohalogens             active materials released during an and Particulates          and particulates                   accident from unidentified release oaths (permanently install-               (not covered by effluent monitors).
-site de-pendent.For estimating releases rates of radio active materials released during an accident from unidentified release oaths (not covered by effluent monitors).
ed monitors)                       Continuous collection of representative samples followed by monitoring (measure-ments) of the samples. (Approximately 16 to 20 locations)
Continuous collection of representative samples followed by monitoring (measure-ments) of the samples. (Approximately 16 to 20 locations)
AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM THE PLANT CONTINUED:
During and following an accident, to mc-.itor radiation and airborne radioactivi concentrations in many areas throughout the facility where is impractical to install stationary monitors capable of covering both normal and accident level: During and following an accident to rap-idly scope the composition or ga-a-emitting sources.1.97-20 I Tvn0a Rance* oe TABLE 2 -PWR VARIABLES contoed -Measured Variable POST-ACCIDENT SAMPLING CAPABILITY:
Plant and Environs    Normal Range                            During and following an accident, to mc-.
Primary Coolant Sumps Containment Air POST-ACCIDENT ANALYSIS CAPABILITY (ONSITE): ifETEOROLOGY:
Radioactivity            0.1 to 104 mR/hr                     itor radiation and airborne radioactivi (portable instruments photons                                  concentrations in many areas throughout 10-9 to O14 4C4/cc                   the facility where        is impractical to particulates                         install stationary monitors capable of covering both normal and accident level:
Wind Direction Wind Speed Vertical Temperature Difference Precipitation I I- -j 'Al IJS.JQ, I -As required based on Reg Guide 1.4 guide-lines 1.2.3.4.S.gamma-ray spectrum pH hydrogen oxygen boron 0 to 360° (+/-5' accur-acy with a deflection of 15G. Starting speed 0.45 mps (1 mph)0 to 30 mps (67 mph)(*0.22 mps (0.5 mph)accuracy for wind spee less that 11 mps (25 m ph), with a starting threshold of less than 0.45 mps (1 mph)-90F to +9 0 F accuracy per intervals (+/-0.3 0 F 164 foot Recording rain gage with range sufficient to assure accuracy of total accumulation within iO% of record-ed value -0.01" resolution ZWA E E I Provide means for safe and convenient sampling.
10-9 to 10-4 UCi/cc iodine High Range 0.1 to 104 R/hr photo-as 0.1 to 104 rads/hr betas and low energy photons lO-channel gamra-ray                   During and following an accident to rap-spectrometer                         idly scope the composition or ga-a-emitting sources.
These provisions should include: 1. shielding to .maintain radiation doses ALARA, 2. sample containers with container-sampling port connector comnatibili
1.97-20
'3. capability of sampling under primary system pressure and negative pressur 4. handling and transport capability, a: 5. pre-arrangement for analysis and interpretation.
 
For determining affluent transport direc-tion for emergency planning, dose assess-ment, and source estimates.
TABLE 2 - PWR VARIABLES contoed -
For determining effluent travel speed anc dilution for emergency planning,, doses assessments and source estimates.
Measured Variable                Range              Tvaho                        pi1on I      I-                           - j                      'Al IJS.JQ, POST-ACCIDENT SAMPLING    I-CAPABILITY:
For determining effluent diffusion rates for emergency planning, dose assessments and source estimates.
Primary Coolant          As required based on        ZWA        Provide means for safe and convenient Sumps                    Reg Guide 1.4 guide-                   sampling. These provisions should Containment Air          lines                                  include:
For determining effluent transport and ground deposition for emergency planning.Notes for Table 2 -(1) Design flow -the maximum flow anticipated in normal operation.
: 1. shielding to .maintain radiation doses ALARA,
(2) Design pressure -that value corresponding to AS1LE code values which are obtained at or below code allowable material design stress values.1. 97-21 Range Tvaho pi 1on ,
: 2. sample containers with container-POST-ACCIDENT ANALYSIS        1. gamma-ray spectrum CAPABILITY (ONSITE):                                                      sampling port connector comnatibili '
TABLE 3 -BWR VARIABLES Measured Variable CORE: Control Rod Position Neutron Flux REACTOR COOLANT SYSTEM: RCS Pressure Coolant Level in the Reactor Main Steamline Flow Main Steamline Isola-tion Valves' Leakage Control System Press-ure Primary System Safety Relief Valve Posi-tions including ADS or Flow Through or Pressure in Valve Lines Radiation Level in Coolant Range I -. i Full in in or not full 1 c/s to 1% power (at least one fission counter)15 psia to 2000 psig Bottom of core support plate to above top of discharge plenum 0 to 120% design flow 1 0 to 15" of water 0 to 5 psid Closed-not closed or 0 to 30 psig 10 pCi/g D B B,C B B B B,D to 10 Ci/g C Provide positive indication that the control rods are fully inserted.(Minimum of 2 hours after accident)ANS-4.5, Section 6.2.2 For indication of approach to criticality ANS-4.5, Sections 6.2.3, 6.2.4, 6.3.3 and 6.3.5 For indication of an accident and to in-dicate that actions must be taken to mitigate an event.ANS-4.5, Section 6.2.3 For indication of fuel submergency for a LOCA event.To provide an indication of the integrity of the pressure boundary.To provide an indication of the pressure boundary and containment integrity.
: 2. pH                                  3. capability of sampling under primary
By these measurements the operator knows if there is a path open for loss of cool-ant and that an event may be in progress.ANS-4.5, Section 6.3.2 For early indication of fuel cladding failure and estimate of extent of damage.1.97-22 0.Ty pe Puirnnos
: 3. hydrogen                                system pressure and negative pressur
: TABLE 3 -BWR VARIABLES continued
: 4. oxygen                              4. handling and transport capability, a:
-Measured Variable CONTAINMENT:
S. boron                                5. pre-arrangement for analysis and interpretation.
Primary Containment Pressure Containment and Dry-well Hydrogen Concentration Containment Isolation Valve Position£Suppression Pool Water Level Suppression Pool Water Temperature Drywell Pressure Drywell Drain Sumps Level (Identified and Unidentified Leakage)High Range Contain-ment Area Radiation Range 10 psia pressure to 3 times design press-ure 2 for concrete; 4 times design pressure for steel 0 to 10%(capability of oper-ating from 12 psia to maximum design press-ure 2 Closed-not closed Top of vent to top of weir well 50 0 F to 250 0 F 12 psia to 3 psig o to 110% design pressure Bottom to top 1 to 107 R/hr (60 keV to 3 MeV pho-tons with +/-20% acc-uracy for photons of 0.1 to 3 MeV)[ 10'R/hr for photons is approximately equiva-lent to 108 rads/hr for betas and photons]T -Ir--o BC B,C B,D B 3 B E B,C B,C ANS-4.5, Sections 6.2.5, 6.3.3, 6.3.4, and 6.3.5 For indication of the intergrity of the primary containment pressure boundary;to indicate the potential for leakage from the containment.
ifETEOROLOGY:
ANS-4.5, Sections 6.2.5, and 6.3.5 For indication of the need for, and a measurement of the performance of the containment hydrogen recombiner and to verify the operation of the mixing system ANS-4.5, Section 6.2.5 To indicate the status of containment isolation and to provide information on the status of valves in process lines which could carry radioactive materials out of containment.
Wind Direction           0 to 360° (+/-5' accur-         E        For determining affluent transport direc-acy with a deflection                  tion for emergency planning, dose assess-of 15G. Starting speed                  ment, and source estimates.
ANS-4.5, Section 6.3.3 To assure proper temperature~for NPSH of ECCS. To verity the operation of the makup system.ANS-4.5. Section 6.3.3 Diagnosis of impact of accident on dr7-well structure.
0.45 mps (1 mph)
ANS-4.5, Section 6.3.3 To help identify if an accident has de-graded beyond calculated values and in-dicate its magnitude and to determine action to protect the public.1.97-23 Type Purnosp TABLE 3 -8WR VARIABLES contin 9 d -Measured Variable I Range POWER CONVERSION SYSTEMS Main Feedwater Flow Condensate Storage Tank Level AUXILIARY SYSTEMS: Containment Spray Flow Steam Flow to RCIC RCIC Flow RHR System Flow RHR Heat Exchanger Outlet Temperature Service Cooling Water Temperature Service Cooling Water Flow Flow in UHS Loop Temperature in Ulti-mate Heat Sink Loop Ultimate Heat Sink Level -SLCS Storage Tank Level Sump Level in Spaces of Equipment Required for Safety O to 110% design flow 1 Bottom to top O to i10% design flow 1 O to 110% design flowl 0 to 0 to 32 0 F 110% design flow 1 110% design flow 1 to 350 0 F 32 0 F to 200 0 F O to 0 to 30 0 F Tvoe v tI E E D 110% design flow 1 110% design flow 1 to 150 0 F Plant specific Bottom to top To corresponding level of safety equipment failure To indicate an adequate source of water to the reactor.To indicate available water for core cooling.For indication of system operation.
Wind Speed              0 to 30 mps (67 mph)                   For determining effluent travel speed anc
To verify that adequate steam is avail-able for the system to perform its function.For indication of system operation.
(*0.22 mps (0.5 mph)                   dilution for emergency planning,, doses accuracy for wind spee                 assessments and source estimates.
For indication of system operation.
less that 11 mps (25 m ph), with a starting threshold of less than 0.45 mps (1 mph)
For indication of system operation.
                            -90F to +90 F (+/-0.3 0 F Vertical Temperature Difference              accuracy per 164 foot E      I For  determining effluent diffusion rates for emergency planning, dose assessments intervals                              and source estimates.
For indication of system For For For indication indication indication of of of system sys tem system operation.
Precipitation          Recording rain gage                      For determining effluent transport and with range sufficient                    ground deposition for emergency planning.
o ai operation.
to assure accuracy of total accumulation within iO% of record-ed value - 0.01" resolution Notes for Table 2 -
operation.
(1) Design flow -  the maximum flow anticipated in normal operation.
operation.
(2) Design pressure - that value corresponding to AS1LE code values which are obtained at or below code allowable material design stress values.
To ensure adequate source of cooling water.To provide indication of inventory fcr boron injection for shutdown.To monitor potential for failure of equipment in closed spaces due to flooding.1.97-24 Piironca TABLE 3 -BWR VARIABLES co nued -Measured Variable RADWASTE SYSTEMS: High Radioactivity Liquid Tank Level Charcoal Delay Gas System Gas Flow or Radioactivity Level VENTILATION SYSTEMS: Emergency Ventilatioi Damper Position Temperature of in Vicinity of pment Required Safety Space Equi-for POWER SUPPLIES: Status of Class lE Power Supplies and Systems Status of Non-Class lE Power Supplies and Systems RADIATION EXPOSURE RATES INSIDE BUILDINGS OR AREAS WHERE ACCESS IS REQUIRED TO SERVICE SAFETY RELATED EQUIP-MENT: Radiation Zxposure Rates Range; --d __I -_ _ _ .I I I I Top to bottom As required Open-closed status 30 0 F to 130 0 F Voltages and currents Voltages and currents 101- to 10 R/hr for photons (permanently install-ed monitors)Available volume to store primarv coolant.To monitor performance of system.To ensure proper ventilation under accident conditions.
: 1. 97-21
To monitor environmental conditions of equipment in closed spaces.To ensure an adequate source power for safety systems of electric To indicate an adequage source of electric power.For measurement of high-range radiation exposure rates 2a various locations.
 
1.97-25 Type Piurnnca TABLE 3 -BWR VARIABLES coriued -Measured Variable AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM THE PLANT: Effluent Radioactiv-ity -Noble Gases.Containment Exhaust Vent and St andby Gas Treatment Sys-tem Vent-Other Release Points [including fuel handling bui-lding, auxiliary building, and tur-bine building]Effluent Radioactiv-ity -High Range Radiohalogens and Particulates.Untreated EffluentE.HEPA Filters, min-imum of 2" *of TEDA impregnated char-coal, non-ESF sys-tems.HEPA Filters, min-imum of 4" of TEDAi impregnated char-coal, ESF systems Environs Radioactiv-ity -High Range Exposure Rate Environs Radioactiv-ity -Radiohalogens and Particulates Range (Normal plus accident range for noble gas)10-7 to 105 llCi/cc Xe-133 calibration l0-7 to Xe-133 102 PCi/cc calibration (permanently install-ed monitors)10-3 to 102 lCi/cc 10-3 to 10 vCi/cc 10-3 to 1 PCi/cc (permanently install-ed monitors)10-3 to 102 R/hr (60 keV to 3 MeV)(permanently install-ed monitors)10-9 to 10-3 Ci/cc for both radiohalogens and particulates (permanently install-ed monitors)Type E E Pu ro as e ANS-4.5, Section 6.2.6 To provide operator with information re-garding release of radioactive noble gases on a continuous basis.To provide the operator with information regarding release of radioactive halogens and particulates.
0                                    .
Continuous collection of representative samples followed by monitoring (measurements) of samples for radiohalogens and for particulates.
TABLE 3 - BWR VARIABLES Measured Variable              Range            Ty pe                    Puirnnos I                            -. i CORE:
For estimating release rates of radio-active materials released during an accident from unidentified release paths (not covered by effluent monitors)
Control Rod Position  Full in or not full        D      Provide positive indication that the in                                control rods are fully inserted.
-continuous readout capability, approxi-mately 16 to 20 locations
(Minimum of 2 hours after accident)
-site de-pendent.For estimating releases rates of radio-active materials released during an accident from unidentified release paths (not covered by effluent monitors).
Neutron Flux            1 c/s to 1% power        B      ANS-4.5, Section 6.2.2 (at least one fission            For indication of approach to criticality counter)
Continuous collection of representative samples followed by monitoring (measure-ments) of the samples. (Approxi ately 16 to 20 locations)
REACTOR COOLANT SYSTEM:
: 1. 97-26 Puroose TABLE 3 -BWR VARIABLES co ued -Measured Variable AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM1 THE PLANT CONTINUED:
RCS Pressure            15 psia to 2000 psig      B,C    ANS-4.5, Sections 6.2.3, 6.2.4, 6.3.3 and 6.3.5 For indication of an accident and to in-dicate that actions must be taken to mitigate an event.
Plant and Environs Radioactivity (portable instruments POST-ACCIDENT SAMPLING CAPABILITY:
Coolant Level in the    Bottom of core support    B      ANS-4.5, Section 6.2.3 Reactor                plate to above top of             For indication of fuel submergency for discharge plenum                 a LOCA event.
Primary Coolant Suppression Pool Containment Air POST-ACCIDENT ANALYSIS CAPABILITY (ONSITE): METEOROLOGY:
Main Steamline Flow    0 to 120% design flow1    B      To provide an indication of the integrity of the pressure boundary.
Wind Direction Wind Speed Range Normal Ranae 0.1 to 10mR/hr photons 10-9 to 10-4 11Ci/cc particulates 10-9 to 10-4 4Ci/cc iodine High Range 0.1 to 104 R/hr photons 0.1 to 104 rads/hr betas and low energy photons 100-channel gamma-ray spectrometer As required based on Reg Guide 1.3 guide-lines 1.-2 .3 .4.gamma-ray spectrum pH hydrogen oxygen 0 to 360° (+/-50 accur-acy with a deflection of 150. Starting speed 0.45 mps (1 mph)0 to 30 mps (67 mph)(+/-0.22 mps (0.5 mph)accuracy for wind speeI less that 11 mps (25 m on), with a starting threshold of less than 0.45 mps (1 mph)Type E N/A N/A E E S Pu ro Os e During and following an accident, to mon-itor radiation and airborne radioactivity concentrations in many areas throughout the facility where is impractical to install stationary monitors capable of covering both normal and accident levels.During and following an accident to rap-idly scope the composition of gamma-emitting sources.Provide.means for safe and convenient sampling.
Main Steamline Isola-  0 to 15" of water         B      To provide an indication of the pressure tion Valves' Leakage    0 to 5 psid                       boundary and containment integrity.
These provisions should include: 1. shielding to maintain radiation doses ALARA, 2. sample containers with container-sampling port connector compatibility.
Control System Press-ure Primary System Safety  Closed-not closed         B,D    By these measurements the operator knows Relief Valve Posi-                or                     if there is a path open for loss of cool-tions including ADS    0 to 30 psig                     ant and that an event may be in progress.
: 3. capability of sampling under primary system pressure and negative pressure 4. handling and transport capability, ark 5. pre-arrangement for analysis and interpretation.
or Flow Through or Pressure in Valve Lines Radiation Level in      10 pCi/g  to 10 Ci/g     C       ANS-4.5, Section 6.3.2 Coolant                                                  For early indication of fuel cladding failure and estimate of extent of damage.
For determining affluent transport direc-tion for emergency planning, dose assess-ment, and source estimates.
1.97-22
For determining effluent travel speed and dilution for emergency planning,, doses assessments and source estimates.
 
1.97-27 Puroose TABLE 3 -8WR VARIABLES cifinued -Measured Variable MEETEOROLOGY CONTINUED:
TABLE 3 - BWR VARIABLES continued -
Vertical Temperature Difference Precipitation Range 0 I__ _ _ _ _ __ -I -I WI U CZ I-9*F to +9 0 F (tO.307 accuracy per 164 foot intervals Recording rain gage with range sufficient to assure accuracy of total accumulation within 1O% of record-ed value -0.01" resolution E For determining effluent diffusion rates for emergency planning, dose assessment C and source estimates.
Measured Variable              Range          Type                  Purnosp
For determining effluent transport and ground deposition for emergency planning Notes for Table 3 -(1) Design flow -the maximum flow anticipated in normal operation.(z) Design pressure -that value corresponding to ASM code values which are obtained at or below code allowable material design scress values.1. 97-28 IT/Os of1'M en ft 0 0 ANS-4. 5 Draft 3 September, DRAFT CAUTION NOTICE: This Standard is being prepared or reviewed and has not been approved by ANS. It is subject to revision or withdrawal before issue.DRAFT American National Standard FUNCTIONAL REQUIRE1ENTS FOR POST ACCIDENT MONITORING CAPABILITY FOR THE CONTROL ROOM OPERATOR OF A NUCLEAR POWER GENERATING STATION Assigned Correspondent
                                      -          T                          Ir--o CONTAINMENT:
-T. F. Timmons Westinghouse Electric Corporation Power Systems Company P.O. Box 355, MNC-410 Pittsburgh, PA 15230 1979 09 Writing Group ANS 4.5 Standards Committee NUPPSCO Secretariat ANS 0 0 TABLE OF CONTENTS FOREWORD 1.0 Introduction 2.0 Scope 3.0 Definition 4.0 Discussion 5.0 Design Basis 6.0 Design Criteria -Phase I and Phase II FOREWORD ANS 4 established Working Group 4.5 in late July 1979 to prepare a draft standard on Accident Monitoring Instrumentation which would complement other standards, but be broader in nature by including economic consid-erations.
Primary Containment    10 psia pressure to       BC  ANS-4.5, Sections 6.2.5, 6.3.3, 6.3.4, Pressure                3 times design press-          and 6.3.5 ure2 for concrete; 4          For indication of the intergrity of the times design pressure          primary containment pressure boundary; for steel                      to indicate the potential for leakage from the containment.
Two primary objectives were 1) to address that instrumenta-tion which permits the operator to monitor expected parameter changes in the accident period, and 2) to address extended range instrumentation deemed appropriate for the possibility of encountering previously unforeseen events.ANS 4.5 began work on July 30th and met for 13 working days in a seven week period. In addition, a Design Criteria subgroup met for two days in this same period.As presented, this draft standard provides: 1. a list of functions to be performed (design basis section 5.0)2. a framework to determine those variables to be monitored (design basis section 5.0)3. an identification of three time periods of interest (definitions 3.0)4. an identification of four variable types (definitions 3.0)5. a delineation of applicable design criteria for the variables to be monitored (design criteria section 6.0)No identification of specific Type A monitored variables is provided in this standard.
Containment and Dry-    0 to 10%                  B,C  ANS-4.5, Sections 6.2.5, and 6.3.5 well Hydrogen          (capability of oper-          For indication of the need for, and a Concentration          ating from 12 psia to          measurement of the performance of the maximum design press-         containment hydrogen recombiner and to ure 2                          verify the operation of the mixing system Containment Isolation   Closed-not closed        B,D  ANS-4.5, Section 6.2.5 Valve Position                                         To indicate the status of containment isolation and to provide information on the status of valves in process lines which could carry radioactive materials out of containment.
Recommendations for Type 3 and Type C monitored vari-ables are provided in Section 6.0.i The significant issues in the development of this standard have been: 1. the scope of the document in terms of applicability to the control room operator or the plant operator (licensee).
                      £ Suppression Pool        Top of vent to top of   B    ANS-4.5, Section 6.3.3 Water Level            weir well Suppression Pool        500 F to 2500 F         3   To assure proper temperature~for NPSH of Water Temperature                                      ECCS. To verity the operation of the makup system.
The work group chose a control room operator scope.2. the pre-planned operator actions designated by the accident analyses in Chapter 15 of a plant's FSAR and the not previously planned operator action that may be required during unforeseen events. The Working Group established Type A instrumentation for the former, and Type B or C instrumentation for the latter.3. The monitoring of actual fission product barrier integrity and the potential for breach of a given barrier. The work group chose monitoring of actual breach for the fuel, reactor coolant system, and containment barrier, but only the potential breach of the con-tainment barrier.4. the degree of alignment of accident monitoring instrumentation with IEEE Class .E (ANS Class EC-3) and whether an intermediate class is needed between 1E and non-1E.5. whether a list of variables should be included as an appendix to the standard: a. a list of only Type C parameters
Drywell Pressure        12 psia to 3 psig        B    ANS-4.5. Section 6.3.3 o to 110% design        E    Diagnosis of impact of accident on dr7-pressure                      well structure.
Drywell Drain Sumps    Bottom to top            B,C  ANS-4.5, Section 6.3.3 Level (Identified and Unidentified Leakage)
High Range Contain-     1 to 107 R/hr            B,C  To help identify if an accident has de-ment Area Radiation    (60 keV to 3 MeV pho-          graded beyond calculated values and in-tons with +/-20% acc-            dicate its magnitude and to determine uracy for photons of          action to protect the public.
0.1 to 3 MeV)[ 10' R/hr for photons is approximately equiva-lent to 108 rads/hr for betas and photons]
1.97-23
 
TABLE 3 - 8WR VARIABLES contin9 d -
Measured Variable      I          Range            Tvoe                    Piironca v  tI POWER CONVERSION SYSTEMS Main Feedwater Flow      O to 110% design flow1  E        To indicate an adequate source of water to the reactor.
Condensate Storage      Bottom to top            E        To indicate available water for core Tank Level                                                cooling.
AUXILIARY SYSTEMS:
Containment Spray        O to i10% design flow1  D      For indication of system operation.
Flow Steam Flow to RCIC      O to 110% design flowl          To verify that adequate steam is avail-able for the system to perform its function.
RCIC Flow                0 to 110% design flow 1           For indication of system operation.
RHR System Flow         0 to 110% design flow1            For indication of system operation.
RHR Heat Exchanger       32 0 F to 350 0 F                For indication of system operation.
Outlet Temperature Service Cooling         320 F to 2000 F                  For indication of system operation.
Water Temperature o ai Service Cooling         O to 110% design flow1            For indication of system operation.
Water Flow Flow in UHS Loop         0 to 110% design flow 1          For indication of sys tem operation.
Temperature in Ulti-     30 0 F to 150 0 F                For indication of system operation.
mate Heat Sink Loop Ultimate Heat Sink       Plant specific                    To ensure adequate source of cooling Level         -                                           water.
SLCS Storage Tank       Bottom to top                    To provide indication of inventory fcr Level                                                     boron injection for shutdown.
Sump Level in Spaces     To corresponding level          To monitor potential for failure of of Equipment Required   of safety equipment              equipment in closed spaces due to for Safety              failure                          flooding.
1.97-24
 
TABLE 3 - BWR VARIABLES co        nued -
Measured Variable                Range                Type                    Piurnnca
                          ;      -    __I
_  _    _    - d    .- I I                                I    I RADWASTE SYSTEMS:
High Radioactivity        Top to bottom                        Available volume to store primarv Liquid Tank Level                                              coolant.
Charcoal Delay Gas        As required                          To monitor performance of system.
System Gas Flow or Radioactivity Level VENTILATION SYSTEMS:
Emergency Ventilatioi    Open-closed status                  To ensure proper ventilation under Damper Position                                                accident conditions.
Temperature of Space      300 F to 1300 F                     To monitor environmental conditions of in Vicinity of Equi-                                          equipment in closed spaces.
pment Required for Safety POWER SUPPLIES:
Status of Class lE      Voltages and currents                To ensure an adequate source of electric Power Supplies and                                            power for safety systems Systems Status of Non-Class      Voltages and currents                To indicate an adequage source of lE Power Supplies                                            electric power.
and Systems RADIATION EXPOSURE RATES INSIDE BUILDINGS OR AREAS WHERE ACCESS IS REQUIRED TO SERVICE SAFETY RELATED EQUIP-MENT:
Radiation Zxposure        101- to 10 R/hr for                  For measurement of high-range radiation Rates                    photons                              exposure rates 2a various locations.
(permanently install-ed monitors) 1.97-25
 
TABLE 3 - BWR VARIABLES coriued -
Measured Variable              Range              Type                Puroose Pu ro as e AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM THE PLANT:
Effluent Radioactiv-    (Normal plus accident          ANS-4.5, Section 6.2.6 ity - Noble Gases        range for noble gas)          To provide operator with information re-
    .Containment Exhaust                                  garding release of radioactive noble 10-7 to 105 llCi/cc Vent and St andby                                    gases on a continuous basis.
Xe-133 calibration Gas Treatment Sys-tem Vent
    -Other Release        l0-7 to 102 PCi/cc Points [including      Xe-133 calibration fuel handling bui-lding, auxiliary      (permanently install-building, and tur-   ed monitors) bine building]
Effluent Radioactiv-                                E  To provide the operator with information ity - High Range                                       regarding release of radioactive halogens Radiohalogens and                                       and particulates. Continuous collection Particulates                                            of representative samples followed by
    .Untreated EffluentE                                  monitoring (measurements) of samples for 10-3 to 102 lCi/cc radiohalogens and for particulates.
    .HEPA Filters, min-    10-3 to 10 vCi/cc imum of 2" *of TEDA impregnated char-coal, non-ESF sys-tems
    .HEPA Filters, min-    10-3 to 1 PCi/cc imum of 4" of TEDAi impregnated char-     (permanently install-ed monitors) coal, ESF systems Environs Radioactiv-     10-3 to 102 R/hr              For estimating release rates of radio-ity - High  Range      (60 keV to 3 MeV)              active materials released during an Exposure Rate                                          accident from unidentified release paths (permanently install-ed monitors)                  (not covered by effluent monitors) -
continuous readout capability, approxi-mately 16 to 20 locations - site de-pendent.
Environs Radioactiv-     10-9 to 10-3 Ci/cc        E  For estimating releases rates of radio-ity - Radiohalogens      for both radiohalogens        active materials released during an and Particulates        and particulates              accident from unidentified release paths (permanently install-         (not covered by effluent monitors).
ed monitors)                  Continuous collection of representative samples followed by monitoring (measure-ments) of the samples.    (Approxi ately 16 to 20 locations)
: 1. 97-26
 
TABLE 3 - BWR VARIABLES co    ued -
Measured Variable              Range             Type                  Puroose Pu ro Os e AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM1 THE PLANT CONTINUED:
Plant and Environs     Normal Ranae                E  During and following an accident, to mon-Radioactivity          0.1 to 10mR/hr                itor radiation and airborne radioactivity (portable instruments photons                        concentrations in many areas throughout the facility where        is impractical to 10-9 to 10-4 11Ci/cc particulates install stationary monitors capable of covering both normal and accident levels.
10-9 to 10-4 4Ci/cc iodine High Range 0.1 to 104 R/hr photons 0.1 to 104 rads/hr betas and low energy photons 100-channel gamma-ray          During and following an accident to rap-spectrometer                  idly scope the composition of gamma-emitting sources.
POST-ACCIDENT SAMPLING CAPABILITY:
Primary Coolant        As required based on      N/A Provide.means for safe and convenient Suppression Pool        Reg Guide 1.3 guide-           sampling. These provisions should Containment Air        lines                          include:
: 1. shielding to maintain radiation doses ALARA,
: 2. sample containers with container-POST-ACCIDENT ANALYSIS    1.- gamma-ray spectrum    N/A    sampling port connector compatibility.
CAPABILITY (ONSITE):      2. pH                          3. capability of sampling under primary
: 3. hydrogen                        system pressure and negative pressure
: 4. oxygen                      4. handling and transport capability, ark
: 5. pre-arrangement for analysis and interpretation.
METEOROLOGY:
Wind Direction        0 to 360° (+/-50 accur-       E  For determining affluent transport direc-acy with a deflection          tion for emergency planning, dose assess-of 150. Starting speed          ment, and source estimates.
0.45 mps (1 mph)
Wind Speed            0 to 30 mps (67 mph)       E  For determining effluent travel speed and
(+/-0.22 mps (0.5 mph)            dilution for emergency planning,, doses accuracy for wind speeI  S    assessments and source estimates.
less that 11 mps (25 m on), with a starting threshold of less than 0.45 mps (1 mph) 1.97-27
 
TABLE 3 - 8WR VARIABLES cifinued -
0 Measured Variable              Range             I__IT/Os
                                                      - _I -_ _ I_  __
of1'M en WI  U ft CZ I
MEETEOROLOGY CONTINUED:
Vertical Temperature    -9*F to +90 F (tO.307                    For determining effluent diffusion rates Difference              accuracy per 164 foot                    for emergency planning, dose assessment C intervals                                and source estimates.
Precipitation          Recording rain gage          E          For determining effluent transport and with range sufficient                    ground deposition for emergency planning to assure accuracy of total accumulation within 1O% of record-ed value - 0.01" resolution Notes for Table 3 -
(1) Design flow - the maximum flow anticipated in normal operation.
(z) Design pressure - that value corresponding to ASM code values which are obtained at or below code allowable material design scress values.
: 1. 97-28
 
0                                 0 ANS-4. 5 Draft 3 September, 1979 DRAFT CAUTION NOTICE: This Standard is being prepared or reviewed and has not been approved by ANS. It is subject to revision or withdrawal before issue.
09 DRAFT American National Standard FUNCTIONAL REQUIRE1ENTS FOR POST ACCIDENT MONITORING CAPABILITY FOR THE CONTROL ROOM OPERATOR OF A NUCLEAR POWER GENERATING STATION Assigned Correspondent
                  - T. F. Timmons Westinghouse Electric Corporation Power Systems Company P.O. Box 355, MNC-410 Pittsburgh, PA 15230 Writing Group ANS 4.5 Standards Committee NUPPSCO Secretariat ANS
 
0                          0 TABLE OF CONTENTS FOREWORD 1.0    Introduction 2.0    Scope 3.0    Definition 4.0    Discussion 5.0    Design Basis 6.0    Design Criteria - Phase I and Phase II
 
FOREWORD ANS 4 established Working Group 4.5 in late July 1979 to prepare a draft standard on Accident Monitoring Instrumentation which would complement other standards, but be broader in nature by including economic consid-erations. Two primary objectives were 1) to address that instrumenta-tion which permits the operator to monitor expected parameter changes in the accident period, and 2) to address extended range instrumentation deemed appropriate for the possibility of encountering previously unforeseen events.
ANS 4.5 began work on July 30th and met for 13 working days in a seven week period. In addition, a Design Criteria subgroup met for two days in this same period.
As presented, this draft standard provides:
: 1. a list of functions to be performed (design basis section 5.0)
: 2. a framework to determine those variables to be monitored (design basis section 5.0)
: 3. an identification of three time periods of interest (definitions 3.0)
: 4. an identification of four variable types (definitions 3.0)
: 5. a delineation of applicable design criteria for the variables to be monitored (design criteria section 6.0)
No identification of specific Type A monitored variables is provided in this standard. Recommendations for Type 3 and Type C monitored vari-ables are provided in Section 6.0.
i
 
The significant issues in the development of this standard have been:
: 1. the scope of the document in terms of applicability to the control room operator or the plant operator (licensee). The work group chose a control room operator scope.
: 2. the pre-planned operator actions designated by the accident analyses in Chapter 15 of a plant's FSAR and the not previously planned operator action that may be required during unforeseen events. The Working Group established Type A instrumentation for the former, and Type B or C instrumentation for the latter.
: 3. The monitoring of actual fission product barrier integrity and the potential for breach of a given barrier. The work group chose monitoring of actual breach for the fuel, reactor coolant system, and containment barrier, but only the potential breach of the con-tainment barrier.
: 4. the degree of alignment of accident monitoring instrumentation with IEEE Class .E(ANS Class EC-3) and whether an intermediate class is needed between 1E and non-1E.
: 5. whether a list of variables should be included as an appendix to the standard:
: a. a list of only Type C parameters
: b. a list of Type A, 3, C and 0 parameters
: b. a list of Type A, 3, C and 0 parameters
: 6. the definition of instrument types 3 and 0 and whether these types should be included in the standard.The membership of the Working Group is as follows: L. Stanley, Chairman T. Timmons, Vice Chairman and Correspondent ii
: 6. the definition of instrument types 3 and 0 and whether these types should be included in the standard.
: 0. Scmmers E. Wenzinger 0. Lambert R. Bauerle J. Castanes M. Wolpert H. Mumford X. Polanski E. Oowling Additional input has been provided to the Working Group by industry, university, and government participants throughout the meetings.
The membership of the Working Group is as follows:
The Work Group is very appreciative of this assistance.
L. Stanley, Chairman T. Timmons, Vice Chairman and Correspondent ii
A iii 1.0 introduction The Code of Federal Regulations requires that instrumentation be provided to monitor variables and systems over their anticipated ranges for acci-dent conditions as appropriate to assure adequate safety. The purpose of this standard is to establish criteria for the selection of that instru-mentation.
: 0. Scmmers E. Wenzinger
These criteria are based on the sequence and duration of the phases through which an accident progresses.
: 0. Lambert R. Bauerle J. Castanes M. Wolpert H. Mumford X. Polanski E. Oowling Additional input has been provided to the Working Group by industry, university, and government participants throughout the meetings. The Work Group is very appreciative of this assistance.
The control room operator may have different information requirements for each phase of an accident.This standard presents criteria for monitoring the response of the plant to design basis events. It also presents criteria for monitoring the integrity of fission product barriers under conditions which have degraded beyond the design bases. This fission product barrier monitoring is con-sidered to be an extra set of instrumentation beyond that required for satisfactorily monitoring accident scenarios postulated in the plant safety analysis.Throughout these criteria, three verbs have been used to indicate the degree of rigor intended by the specific criterion.
A iii
The word "shall" is used to denote a requirement; the word "should" to denote a recommenda-tion; and the word "may" to denote permission, neither a requirement nor a recommendation.
 
1 2.0 SCOPE This standard contains criteria for determining the variables to be moni-tored by the control room operator, as required for safety, during the course of an accident and during the long-term stable shutdown phase fol-lowing the accident.
1.0   introduction The Code of Federal Regulations requires that instrumentation be provided to monitor variables and systems over their anticipated ranges for acci-dent conditions as appropriate to assure adequate safety. The purpose of this standard is to establish criteria for the selection of that instru-mentation. These criteria are based on the sequence and duration of the phases through which an accident progresses. The control room operator may have different information requirements for each phase of an accident.
Also included are criteria for determining the requirements for the equipment used to monitor those variables.
This standard presents criteria for monitoring the response of the plant to design basis events. It also presents criteria for monitoring the integrity of fission product barriers under conditions which have degraded beyond the design bases. This fission product barrier monitoring is con-sidered to be an extra set of instrumentation beyond that required for satisfactorily monitoring accident scenarios postulated in the plant safety analysis.
The scope of the standard is limited to onsite environment and process monitoring.
Throughout these criteria, three verbs have been used to indicate the degree of rigor intended by the specific criterion. The word "shall" is used to denote a requirement; the word "should" to denote a recommenda-tion; and the word "may" to denote permission, neither a requirement nor a recommendation.
Emergency preparedness planning is, or 'will be, covered by other standards.
1
2 3.0 OEFINITIONS Phase I That portion of the accident extending from the initiation of the accident to that point at which the plant is in a con-trolled condition.
 
Phase II That portion of the accident extending from the time at which the plant is in a controlled condition to that point at which personnel access to the location of the accident is possible.Phase III That portion of the accident extending from the time at which personnel access to the location of the accident is possible to the time at which the plant has returned to operating status or been decommissioned.
2.0   SCOPE This standard contains criteria for determining the variables to be moni-tored by the control room operator, as required for safety, during the course of an accident and during the long-term stable shutdown phase fol-lowing the accident. Also included are criteria for determining the requirements for the equipment used to monitor those variables.
Type A Instruments  
The scope of the standard is limited to onsite environment and process monitoring. Emergency preparedness planning is, or 'will be, covered by other standards.
-Those instruments which provide the information required to permit the control room operator to take the pre-planned manual actions to accomplish safe plant shutdown for design basis accident events and to maintain long term plant-stability.
2
Type B Those instruments which provide to the control room operator information to monitor the process of accomplishing critical safety functions, i.e., reactivity control, core cooling, maintaining reactor coolant system integrity, maintaining containment integrity and radioactive effluent control.Type C Those instruments that indicate in the control room (1) the extent to which parameters, which have the potential for causing a breach of the final fission product barrier (i.e., the containment), have exceeded the design basis values, or (2) that a fission product barrier (i.e., fuel clad, reactor coolant pressure boundary or the containment) has been breached.3 Type 0 Those instruments which indicate to the control room operator the performance of individual safety systems.Design Basis Accident Events Those events postulated in the plant safety analyses, any one of which may occur during the lifetime of a particular plant, excluding those events which are expected to occur during a calendar year for a particular plant;and those events that are not expected to occur but are postulated in the plant safety analyses because their consequences would include the poten-tial for the release of significant amounts of radioactive material.4 4.0 DISCUSSION It is the philosophy of this Standard that instrumentation is required to monitor plant performance during and after an accident.
 
The purposes of the accident monitoring instrumentation are enumerated in Section 5.0, Design Basis. This Standard specifies the plant safety functions to be performed and the criteria to be used by the designer in selecting the variables to be monitored.
3.0 OEFINITIONS Phase I   That portion of the accident extending from the initiation of the accident to that point at which the plant is in a con-trolled condition.
Phase II That portion of the accident extending from the time at which the plant is in a controlled condition to that point at which personnel access to the location of the accident is possible.
Phase III That portion of the accident extending from the time at which personnel access to the location of the accident is possible to the time at which the plant has returned to operating status or been decommissioned.
Type A     Instruments - Those instruments which provide the information required to permit the control room operator to take the pre-planned manual actions to accomplish safe plant shutdown for design basis accident events and to maintain long term plant-stability.
Type B   Those instruments which provide to the control room operator information to monitor the process of accomplishing critical safety functions, i.e., reactivity control, core cooling, maintaining reactor coolant system integrity, maintaining containment integrity and radioactive effluent control.
Type C   Those instruments that indicate in the control room (1) the extent to which parameters, which have the potential for causing a breach of the final fission product barrier (i.e.,
the containment), have exceeded the design basis values, or (2) that a fission product barrier (i.e., fuel clad, reactor coolant pressure boundary or the containment) has been breached.
3
 
Type 0     Those instruments which indicate to the control room operator the performance of individual safety systems.
Design Basis Accident Events Those events postulated in the plant safety analyses, any one of which may occur during the lifetime of a particular plant, excluding those events which are expected to occur during a calendar year for a particular plant; and those events that are not expected to occur but are postulated in the plant safety analyses because their consequences would include the poten-tial for the release of significant amounts of radioactive material.
4
 
4.0 DISCUSSION It is the philosophy of this Standard that instrumentation is required to monitor plant performance during and after an accident. The purposes of the accident monitoring instrumentation are enumerated in Section 5.0, Design Basis. This Standard specifies the plant safety functions to be performed and the criteria to be used by the designer in selecting the variables to be monitored.
Certain concepts have been established to aid the system designer in the selection of variables to monitor the course of an accident and to arrive at appropriate design criteria for instruments to monitor these variables.
Certain concepts have been established to aid the system designer in the selection of variables to monitor the course of an accident and to arrive at appropriate design criteria for instruments to monitor these variables.
4.1 Planned Versus Unolanned Operator Actions The plant safety analysis defines the accident scenarios from which the safety system design bases and the planned or anticipated operator actions are derived. Accident monitoring instrumentation is provided to permit the operator to take required actions to address these analyzed.situations.
4.1 Planned Versus Unolanned Operator Actions The plant safety analysis defines the accident scenarios from which the safety system design bases and the planned or anticipated operator actions are derived. Accident monitoring instrumentation is provided to permit the operator to take required actions to address these analyzed.
However, instrumentation must also be provided for unplanned situations, (i.e., to ensure that, should plant conditions evolve differently than predicted by the safety analysis, the operator has sufficient information to monitor the course of the event). Instru-mentation must also be provided to indicate to the operator if fission product barrier integrity has degraded beyond the prescribed limits of the Safety Analysis.4.2 Variable Types Four classifications of variables have been identified.
situations. However, instrumentation must also be provided for unplanned situations, (i.e., to ensure that, should plant conditions evolve differently than predicted by the safety analysis, the operator has sufficient information to monitor the course of the event). Instru-mentation must also be provided to indicate to the operator if fission product barrier integrity has degraded beyond the prescribed limits of the Safety Analysis.
Operator manual actions during accidents included in the plant safety analysis are anticipated or pre-planned.
4.2 Variable Types Four classifications of variables have been identified. Operator manual actions during accidents included in the plant safety analysis are anticipated or pre-planned. Those variables that provide information needed by the operator to perform these manual actions are designated 5
Those variables that provide information needed by the operator to perform these manual actions are designated 5
 
Type A. Those variables needed to assess that the plant safety functions are being accomplished, as identified in the plant safety analysis, are designated Type S. Variables used to monitor for the actual gross breach of one of the fission product barriers or the potential breach of the final fission product barrier (containment) are designated Type C. Type C variables used to monitor the potential breach of containment have an arbitrarily-determined, extended range. The fourth classification, Type D, consists of those variables monitored to ascertain that the safety systems are performing as designed.
Type A. Those variables needed to assess that the plant safety functions are being accomplished, as identified in the plant safety analysis, are designated Type S. Variables used to monitor for the actual gross breach of one of the fission product barriers or the potential breach of the final fission product barrier (containment) are designated Type C. Type C variables used to monitor the potential breach of containment have an arbitrarily-determined, extended range. The fourth classification, Type D, consists of those variables monitored to ascertain that the safety systems are performing as designed. Type 0 variables are less important than Types A, B and C for accident monitoring since safety system per-formance only infers safety function accomplishment. Type 0 variables and instruments are not considered to be within the scope of Accident Monitoring Instrumentation. Guidance on the selection of Type 0 vari-ables and the specification of appropriate design criteria are not given in this standard. This guidance is provided in standards for design of safety systems (e.g. IEEE-603, ANSI N1S.2, etc). The four classifica-tions are not mutually exclusive in that a given variable (or instrument) may be included in one or more types. This differentiation by variable type is intended only to guide the designer in his selection of accident monitoring variables and applicable criteria.
Type 0 variables are less important than Types A, B and C for accident monitoring since safety system per-formance only infers safety function accomplishment.
4.3   Accident Phases The typical accident sequence has been subdivided into three phases:
Type 0 variables and instruments are not considered to be within the scope of Accident Monitoring Instrumentation.
Phase I covers the initial portion of the accident, Phase II covers the stable long-term cooling portion of the accident up to the time where personnel access is possible, and Phase III addresses the period follow-ing personnel access to the accident area. This sub-division has been made so that variable selection and design criteria application can reflect the differing conditions which characterize these three phases.
Guidance on the selection of Type 0 vari-ables and the specification of appropriate design criteria are not given in this standard.
For example, Phase I can be anticipated to be of relatively short dura-tion, having relatively severe plant conditions, and allowing no person-nel access to the accident area. Phase II is expected to be of longer duration, to require a significant number of operator actions, under milder plant conditions, but with still no personnel access to the acci-dent area. Phase III is expected to be of even longer duration where 6
This guidance is provided in standards for design of safety systems (e.g. IEEE-603, ANSI N1S.2, etc). The four classifica-tions are not mutually exclusive in that a given variable (or instrument) may be included in one or more types. This differentiation by variable type is intended only to guide the designer in his selection of accident monitoring variables and applicable criteria.4.3 Accident Phases The typical accident sequence has been subdivided into three phases: Phase I covers the initial portion of the accident, Phase II covers the stable long-term cooling portion of the accident up to the time where personnel access is possible, and Phase III addresses the period follow-ing personnel access to the accident area. This sub-division has been made so that variable selection and design criteria application can reflect the differing conditions which characterize these three phases.For example, Phase I can be anticipated to be of relatively short dura-tion, having relatively severe plant conditions, and allowing no person-nel access to the accident area. Phase II is expected to be of longer duration, to require a significant number of operator actions, under milder plant conditions, but with still no personnel access to the acci-dent area. Phase III is expected to be of even longer duration where 6 personnel access is possible.
 
Oifferent design criteria are then appro-priate for each of the three phases. In this Standard, guidance and criteria are provided for Phases i and Ii.7 5.0 Oesign Basis The plant designer shall perform and document an analysis to select acci-dent monitoring instruments.
personnel access is possible. Oifferent design criteria are then appro-priate for each of the three phases. In this Standard, guidance and criteria are provided for Phases i and Ii.
He shall identify instruments required by his design to enable the control room operator to: A. Perform pre-planned manual actions.B. Ascertain the performance of: (1) Reactivity control (2) Reactor core cooling (3) Reactor coolant system integrity (4) Containment integrity (5) Radioactive effluent control C. Ascertain the extent to which parameters, which have the potential for causing a breach of the containment, have exceeded the design basis values and to ascertain that a fission product barrier (i.e. fuel clad, reactor coolant system pressure boundary or the containment) has been breached.5.1 Variable Selection for Phases I and II The process for selection of the Accident'Monitoring Instrumentation vari-ables shall include: 5.1.1 For Type A 1) Identification of the postulated accidents for which manual action is required.2) Identification of planned operator actions 3) Identification of the monitored variables needed for planned operator actions.a 5.1.2 For Type B 1) identification of the monitored variables that provide the most direct indication needed to assess the accomplish-ments of: a. Reactivity Control b. Reactor Core Cooling c. Reactor Coolant System Integrity d. Containment Integrity e. Radioactive Effluent Control Guidance on the selection of these variables is provided in Section 6.0.5.1.3 For Type C 1) Identification of the monitored variables that provide the most direct indication of a gross breach of a fission product barrier or of an approach to breach of the con-taimment.
7
These instruments may have extended ranges.Guidance on the selection of these variables is provided in Section 6.0.5.1.4 Phase III Access Prior to the termination of Phase II, the ability to gain access to the location of the accident must be determined.
 
Instrumentation that indicates when conditions are acceptable for personnel access shall be identified.
5.0 Oesign Basis The plant designer shall perform and document an analysis to select acci-dent monitoring instruments. He shall identify instruments required by his design to enable the control room operator to:
5.2 PERFORMANCE REQUIREMENTS FOR PHASES I ANO I: The process for determining performance requirements of Accident Moni-toring Instrumentation shall include, as a minimum, the following con-siderations:
A. Perform pre-planned manual actions.
9 5.2.1 For Types A and 8 1) Identification of 2) Identification of 3) Identification of 4) Identification of ment is needed.5) Identification of ment must operate.the the the the expected range of the process variable.required accuracy of measurement.
B. Ascertain the performance of:
required response characteristics.
(1) Reactivity control (2) Reactor core cooling (3) Reactor coolant system integrity (4) Containment integrity (5) Radioactive effluent control C. Ascertain the extent to which parameters, which have the potential for causing a breach of the containment, have exceeded the design basis values and to ascertain that a fission product barrier (i.e. fuel clad, reactor coolant system pressure boundary or the containment) has been breached.
time interval during which the measure-the local environment in which the instru-5.2.2 For Type C The performance requirements for these instruments are arbitrary.
5.1   Variable Selection for Phases I and II The process for selection of the Accident'Monitoring Instrumentation vari-ables shall include:
Guidance on these requirements is provided in Section 6.0.10 6.0 DESIGN CRITERIA 6.1 GENERAL DESIGN CRITERIA 6.1.1 SEISMIC QUALIFICATIONS Accident monitoring instrumentation that is to be seismically qualified shall be qualified according to IEEE Standard 344-1975.
5.1.1   For Type A
The instrumenta-tion shall be qualified to continue to function within the required accuracy following, but not necessarily during, a safe shutdown earth-quake. Vibration loads which occur as a result of plant system operation during any phase for which the instrument is required shall be considered.
: 1) Identification of the postulated accidents for which manual action is required.
6.1.2 DURATION Accident monitoring instrumentation shall be qualified for the length of time its function is required.
: 2) Identification of planned operator actions
Unless other times can be justified, Phase II instrumentation shall be qualified to function for not less than 100 days. A shorter time may be acceptable if instrumentation equipment replacement or repair can be accomplished within an acceotable out-of-service time, taking into consideration the environment where the equip-ment is located.6.1.3 DIRECT MEASUREMENT To the extent practical, accident monitoring instrumentation inputs shall be from sensors that directly measure the desired variables.
: 3) Identification of the monitored variables needed for planned operator actions.
6.1.4 MINIMIZING MEASUREMENTS To the extent practical, the same instruments shall be used for accident monitoring as are used for the normal operations of the plant to enable the operator to use, during an accident situation, instruments with which he is most familiar.
a
However, where the required range of accident moni-toring instrumentation results in a loss of instrumentation sensitivity in the normal operating rance, separate instruments shall be used.11 6.1.5 INSTALLATION Permanently installed instrument equipment is required for those instru-ments required to function during Phase I. Permanently installed instru-mentation systems need not be provided for those functions required only for Phases II and III providing it can be demonstrated that the instru-ment components can be installed when required, considering the local environment.
 
6.1.6 INSTRUMENTATION LOCATION AND IDENTIFICATION Accident monitoring instrumentation shall be located accessible to the operator and be distinguishable from other displays so that in an acci-dent situation, the operator can rapidly identify the accident monitoring instrumentation.
5.1.2   For Type B
6.1.7 EQUIPMENT REPAIR, The accident monitoring instrumentation shall be designed to facilitate timely recognition, location, replacement, and repair or adjustment of malfunctioning equipment.  
: 1) identification of the monitored variables that provide the most direct indication needed to assess the accomplish-ments of:
-6.1.8 TEST AND CALIBRATION 6.1.3.1 Test Capability shall be provided for testing, with a high degree of confi-dence, the operational availability of each instrument channel during plant operation.
: a. Reactivity Control
This may be accomplished in various ways, for example: 1. By observing the effect of perturbing the monitored variable.2. By observing the effect of introducing and varying, as appropriate, a substitute inout to the sensor of the same nature as the measured variable.12
: b. Reactor Core Cooling
: 3. By cross-checking between channels that bear a known relationship to.each other.Where testing during reactor operation is not possible, it must be shown that there is no practical way of implementing such a requirement without adversely affecting plant safety or operability.
: c. Reactor Coolant System Integrity
In addition, it must be shown that the probability of a failure of the component which is not periodically tested is acceptably low and that such testing can be rou-tinely performed when the reactor is shut down.6.1.8.2 Calibration Capability shall be provided for calibration of each instrument channel during normal plant operation or during shutdown as determined by the required interval between calibrations.
: d. Containment Integrity
Equipment that does not require periodic calibration is exempt from this requirement.
: e. Radioactive Effluent Control Guidance on the selection of these variables is provided in Section 6.0.
5.1.9 DIVERSITY Diversity is preferred in fufilling redundancy requirements.
5.1.3   For Type C
5.1.10 REDUNDANT READOUT AMBIGUITY Where a disagreement between redundant displays could lead the operator to defeat or fail to accomplish a required safety function, additional information shall be provided to allow the operator to deduce the actual conditions that are required for him to perform his role. This may be accomplished by providing an independent channel which monitors a dif-ferent variable bearing a known relationship to the redundant channel or by providing an additional independent channel of instrumentation of the same variable or by providing the capability for the operator to perturb the measured variable and determine by observation of the response which instrumentation display has failed.13
: 1) Identification of the monitored variables that provide the most direct indication of a gross breach of a fission product barrier or of an approach to breach of the con-taimment. These instruments may have extended ranges.
* 0 6.2 TYPE B INSTRUMENTS 6.2.1 GENERAL REQUIREMENTS  
Guidance on the selection of these variables is provided in Section 6.0.
-The number of instruments used shall be only that minimum set needed to adequately monitor the accomplishment of the following functions:
5.1.4 Phase III Access Prior to the termination of Phase II, the ability to gain access to the location of the accident must be determined. Instrumentation that indicates when conditions are acceptable for personnel access shall be identified.
: a. Reactivity Control b. Reactor Core Cooling c. Reactor Coolant System Integrity d. Containment Integrity e. Radioactive Effluent Control Type 3 instruments provide control room indication beyond that which may be required for any preplanned operator action and as such constitute an extra set of instrumentation which results in an additional layer of protection.
5.2 PERFORMANCE REQUIREMENTS FOR PHASES I ANO I:
6.2.2 VARIABLES FOR REACTIVITY CONTROL MONITORING The measured variable shall indicate the accomplishment of control of reactivity in the core. The measured variable should be neutron flux.The range of measurement should extend from one count per second on the source range instrument to the intermediate range instrument value cor-responding to 1.5. of full reactor power. This range is intended to encompass all neutron flux levels at which the core can be subcritical.
The process for determining performance requirements of Accident Moni-toring Instrumentation shall include, as a minimum, the following con-siderations:
6.2.3 VARIABLES FOR CORE COOLING MONITORING The measured variables shall indicate the accomplishment of core cool-ing. For the PWR, the measured variables should be TH, TC, pres-surizer level, and pressurizer pressure.
9
For the BWR, the measured variable should be reactor vessel water level. Incore thermocouple monitoring should be considered for inclusion as a desireable variable to ascertain cooling.14 6.2.4 VARIABLES FOR REACTOR COOLANT SYSTEM INTEGRITY The measured variable shall indicate the accomplishment of RCS inte-grity. The measured variable should be primary system pressure.6.2.5 VARIABLES FOR CONTAINMENT INTEGRITY The measured variables shall indicate the accomplishment of containment integrity.
 
The measured variables should be containment hydrogen con-centration, containment pressure and containment isolation valve posi-tions..6.2.6 VARIABLES FOR RADIOACTIVE EFFLUENT CONTROL The measured variables shall indicate the accomplishment of radioactive effluent control. The measured variables should be noble gas monitoring of the identified plant release points.6.3 TYPE C INSTRUMENTS 6.3.1 Type C instruments shall meet the following criteria: 5.3.1.1 The number of instruments used shall be only that minimum set needed to adequately monitor the three barriers;6.3.1.2- Each measurement shall be as direct as possible;6.3.1.3 Any chosen measurement shall detect a gross breach of one or more barriers (i.e., > 1 percent fuel clad failure, a RCS pressure boundary breach producing a loss of reactor coolant inventory in excess of the normal makeup capability, a con-tainment breach capable of producing radiation releases in excess of 10 CFR 100 at the site boundary using TID-14844 source terms); the ranges established for Type C instruments are not mechanistically related to a postulated accident scenario.15 6.3.1.4 During the period of need for Type C instruments, no other failures shall be assumed in the analysis beyond the assumed breach of a barrier coincident with loss of off-site power;0.3.2 Fuel Clad Barrier Monitoring 6.3.2.1 The measured variable shall detect and alarm the breach of the fuel clad barrier (i.e., > 1 percent fuel clad failure);6.3.2.2 Operator sampling of reactor coolant shall be used as the means to verify the measured variable alarm.6.3.2.3 The measured variable should be reactor coolant system radia-tion. The instrument range should be equivalent to the fuel clad gap activity corresponding to 0.5% to 5% failed fuel. A narrow accuracy band for this measured variable is not signi-ficant in achieving this function; for example, +50%, to +100%accuracy of reading should be acceptable.
5.2.1 For Types A and 8
instrument tran-sient response should be compatible with its recorder.5.3.3 Reactor Coolant System Pressure Boundary Monitoring 6.3.3.1 The measured variable(s) shall detect and alarm a breach of the reactor coolant system that produces a loss of coolant inventory in excess of normal makeup capability.
: 1) Identification of   the expected range of the process variable.
The spectrum of RCS pressure boundary breaches extends up to and includes the largest double-ended pipe break.0.3.3.2 The means used to detect RCS pressure boundary breach should include one RCS pressure boundary variable and one containment variable over the full spectrum of break sizes.6.3.3.3 The measured PWR variables should be RCS pressure and contain-ment pressure.
: 2) Identification of   the required accuracy of measurement.
The instrument range should be the design pressure plus a specified margin (< 1O%). Normal instrument accuracy is acceptable for these monitors.
: 3) Identification of   the required response characteristics.
instrument tran-sient response should be compatible with its recorder.16 6.3.3.4 The measured BWR variables should be drywell pressure and containment sump level. The instrument range should be design values plus a specified margin (< 10%). Normal instrument accuracy is acceptable for these monitors.
: 4) Identification of   the time interval during which the measure-ment is needed.
Instrument tran-sient response should be compatible with its recorder.6.3.4 Containment Pressure Boundary Monitoring 6.3.4.1 The measured variable(s) shall detect and alarm a breach of the containment pressure boundary that is capable of producing radiation releases in excess of 10 CFR 100 at the site boundary using TID-14844 source terms.0.3.4.2 The means used to detect containment pressure boundary breach should include containment pressure (BWR and PWR), environs radiation monitoring for gross gamma (PWR), and secondary containment air space radiation monitoring for gross gamma (BWR).6.3.4.3 The instrument range for containment pressure should be design pressure plus a specified margin (< 10%). Normal instrument accuracy is acceptable for this monitor. Instrument transient response should be compatible with its recorder.6.3.4.4 The instrument range for environs radiation monitoring should be 10-3 to 102 R/hr. The instrument range for secondary containment air space radiation monitoring should correspond to the 10 CFR 100 value for off-site doses. Instrument accuracy should be + 1/2 decade (100 Kev-3 Mev). Instrument transient response should be compatible with its recorder.6.3.5 Potential Breach of the Final Fission Product Barrier 6.3.5.1 The measured variables should be containment pressure, con-tainment hydrogen concentration, and RCS pressure for indicating the potential for causing a breach of the final fission product barrier (i.e., containment).
: 5) Identification of   the local environment in which the instru-ment must operate.
17 0 0 5.3.5.2 An arbitrary range of 3 times design pressure for concrete and 4 times design pressure for steel should be used for contain-ment pressure.
5.2.2 For Type C The performance requirements for these instruments are arbitrary.
Instrument accuracy should be + 10% of span.Instrument transient response should be compatible with its recorder.6.3.5.3 An arbitrary range of 0-10 volume percent hydrogen should be used for containment hydrogen concentration.
Guidance on these requirements is provided in Section 6.0.
Instrument accuracy should be + 10% of span. Instrument transient response should be compatiable with its recorder.6.3.5.4 An arbitrary range of 1.5 times design pressure should be used for RCS pressure.
10
Instrument accuracy should be + 10% of span. Instrument transient response should be compatible with its recorder.6.3.6 INSTRUMENT QUALIFICATION 6.3.6.1 Type C instruments shall be qualified in the same manner as Type A instruments except: 6.3.5.1.1 For purposes of equipment qualification, the assumed maximum value of the monitored parameter shall be the value equal to the maximum range for the instrument.
 
The monitored parameter shall be assumed to approach this peak by extrapolating the most severe initial ramp associated with the Design Basis Accidents.
6.0 DESIGN CRITERIA 6.1 GENERAL DESIGN CRITERIA 6.1.1   SEISMIC QUALIFICATIONS Accident monitoring instrumentation that is to be seismically qualified shall be qualified according to IEEE Standard 344-1975. The instrumenta-tion shall be qualified to continue to function within the required accuracy following, but not necessarily during, a safe shutdown earth-quake. Vibration loads which occur as a result of plant system operation during any phase for which the instrument is required shall be considered.
The decay for this parameter shall be considered proportional to the decay for this parameter associated with the Design Basis Accidents.
6.1.2   DURATION Accident monitoring instrumentation shall be qualified for the length of time its function is required. Unless other times can be justified, Phase II instrumentation shall be qualified to function for not less than 100 days. A shorter time may be acceptable if instrumentation equipment replacement or repair can be accomplished within an acceotable out-of-service time, taking into consideration the environment where the equip-ment is located.
No additional qualification margin needs to be added to the extended range parameter.
6.1.3   DIRECT MEASUREMENT To the extent practical, accident monitoring instrumentation inputs shall be from sensors that directly measure the desired variables.
See figure 6.3-1. All environmental envelopes except that per-taining to the parameter measured by the instrument shall be those associated with the Design Basis Accidents.
6.1.4   MINIMIZING MEASUREMENTS To the extent practical, the same instruments shall be used for accident monitoring as are used for the normal operations of the plant to enable the operator to use, during an accident situation, instruments with which he is most familiar. However, where the required range of accident moni-toring instrumentation results in a loss of instrumentation sensitivity in the normal operating rance, separate instruments shall be used.
5.4 SPECIFIC DESIGN CRITERIA Design Criteria specific to particular accident phases and variable types are presented in Table 6.4-1.18 TABLE 6.4.1 DESIGN CRITERIA CRITERION l.. Qualify seismically to IEEE 344-75 (operate after SSE)2. Meet single failure per IEEE 379-77 3. Qualify environmen-tally to IEEE 323-74 4. Consider loss of off-site power 5. Power source, 6. Out of service interval-prior to accident 7. Otit of service inter-val -during accident PHASE 1 VARIABLE TYPE B A Yes Yes Yes Yes Yes Yes Yes Yes Emergency (2) .None Emerg.(2)None C No No A Yes Yes Yes(l)Yes Emerg.<72 fir(3)<2 hir Yes Yes Emerg.(2)(2)PHASE II VARIABLE TYPE B No Yes Yes No Normal(6)(2)(2)C No No Yes U )No Normal (6).<72 fIrs 3)<2 hIrs 0 0 TABLE 6.4-1 (Continued)
11
DESIGLN CRITERIA P11ASE 1 VARIABLE TYPE CRITERION A B 8. Portable instrumenta-No No t iol 9. Level of quality ANSI N45.2 ANSI t assurance 10. Display type(4) Continuous Contif 11. Display method Recording(5)
 
Record 12. Identification as Yes Yes accident monitoring type 13. Periodic Test per Yes Yes IEEE-338-1977 NOTES: (1) See Paragraph 6.3.6 of this Standard.(2) IEEE 279-1971 Paragraph 4.11 Exemuption C No(7)445.2 luou s di ng A Yes ANSI N45.2 Continuous Indicator Yes Yes ANSI N45.2 Continuous Recording(5)
6.1.5   INSTALLATION Permanently installed instrument equipment is required for those instru-ments required to function during Phase I. Permanently installed instru-mentation systems need not be provided for those functions required only for Phases II and III providing it can be demonstrated that the instru-ment components can be installed when required, considering the local environment.
Yes Yes PHASE I I VARIABLE TYPE B Yes ANSI N45.2 Continuous Indicator Yes Yes C Yes ANSI N45.2 On demand Indicator Yes Yes I NOTES TO TABLE 6.4-1 (Continued) 3? Based on normal tech spec requirements on out-of-service safety systems.4 Continuous indication or recording displays a given variable at all times; intermittent indication or recording displays a given variable periodically; on demand indication or recording displays a given variable only when requested.
6.1.6   INSTRUMENTATION LOCATION AND IDENTIFICATION Accident monitoring instrumentation shall be located accessible to the operator and be distinguishable from other displays so that in an acci-dent situation, the operator can rapidly identify the accident monitoring instrumentation.
(5) Where trend or transient information is essential to planned operator actions.(6) May be manually connected to emergency buss (7) Radiation monitoring outside containment may be portable.-4 Figure 6.3-1.Typical Environmental Qualification Envelope for Type C Instruments e- --t I I I i I I I I I k7 Assumied Parameter Environment
6.1.7   EQUIPMENT REPAIR, The accident monitoring instrumentation shall be designed to facilitate timely recognition, location, replacement, and repair or adjustment of malfunctioning equipment.         -
---3,rDesiqn Basis Accident Timee.Parameter 0 4}}
6.1.8   TEST AND CALIBRATION 6.1.3.1   Test Capability shall be provided for testing, with a high degree of confi-dence, the operational availability of each instrument channel during plant operation. This may be accomplished in various ways, for example:
: 1. By observing the effect of perturbing the monitored variable.
: 2. By observing the effect of introducing and varying, as appropriate, a substitute inout to the sensor of the same nature as the measured variable.
12
: 3. By cross-checking between channels that bear a known relationship to.
each other.
Where testing during reactor operation is not possible, it must be shown that there is no practical way of implementing such a requirement without adversely affecting plant safety or operability. In addition, it must be shown that the probability of a failure of the component which is not periodically tested is acceptably low and that such testing can be rou-tinely performed when the reactor is shut down.
6.1.8.2   Calibration Capability shall be provided for calibration of each instrument channel during normal plant operation or during shutdown as determined by the required interval between calibrations. Equipment that does not require periodic calibration is exempt from this requirement.
5.1.9   DIVERSITY Diversity is preferred in fufilling redundancy requirements.
5.1.10   REDUNDANT READOUT AMBIGUITY Where a disagreement between redundant displays could lead the operator to defeat or fail to accomplish a required safety function, additional information shall be provided to allow the operator to deduce the actual conditions that are required for him to perform his role. This may be accomplished by providing an independent channel which monitors a dif-ferent variable bearing a known relationship to the redundant channel or by providing an additional independent channel of instrumentation of the same variable or by providing the capability for the operator to perturb the measured variable and determine by observation of the response which instrumentation display has failed.
13
* 0 6.2   TYPE B INSTRUMENTS 6.2.1   GENERAL REQUIREMENTS           -
The number of instruments used shall be only that minimum set needed to adequately monitor the accomplishment of the following functions:
: a. Reactivity Control
: b. Reactor Core Cooling
: c. Reactor Coolant System Integrity
: d. Containment Integrity
: e. Radioactive Effluent Control Type 3 instruments provide control room indication beyond that which may be required for any preplanned operator action and as such constitute an extra set of instrumentation which results in an additional layer of protection.
6.2.2   VARIABLES FOR REACTIVITY CONTROL MONITORING The measured variable shall indicate the accomplishment of control of reactivity in the core. The measured variable should be neutron flux.
The range of measurement should extend from one count per second on the source range instrument to the intermediate range instrument value cor-responding to 1.5. of full reactor power. This range is intended to encompass all neutron flux levels at which the core can be subcritical.
6.2.3   VARIABLES FOR CORE COOLING MONITORING The measured variables shall indicate the accomplishment of core cool-ing. For the PWR, the measured variables should be TH, TC, pres-surizer level, and pressurizer pressure. For the BWR, the measured variable should be reactor vessel water level. Incore thermocouple monitoring should be considered for inclusion as a desireable variable to ascertain cooling.
14
 
6.2.4   VARIABLES FOR REACTOR COOLANT SYSTEM INTEGRITY The measured variable shall indicate the accomplishment of RCS inte-grity. The measured variable should be primary system pressure.
6.2.5   VARIABLES FOR CONTAINMENT INTEGRITY The measured variables shall indicate the accomplishment of containment integrity. The measured variables should be containment hydrogen con-centration, containment pressure and containment isolation valve posi-tions..
6.2.6   VARIABLES FOR RADIOACTIVE EFFLUENT CONTROL The measured variables shall indicate the accomplishment of radioactive effluent control. The measured variables should be noble gas monitoring of the identified plant release points.
6.3         TYPE C INSTRUMENTS 6.3.1       Type C instruments shall meet the following criteria:
5.3.1.1     The number of instruments used shall be only that minimum set needed to adequately monitor the three barriers; 6.3.1.2-   Each measurement shall be as direct as possible; 6.3.1.3     Any chosen measurement shall detect a gross breach of one or more barriers (i.e., > 1 percent fuel clad failure, a RCS pressure boundary breach producing a loss of reactor coolant inventory in excess of the normal makeup capability, a con-tainment breach capable of producing radiation releases in excess of 10 CFR 100 at the site boundary using TID-14844 source terms); the ranges established for Type C instruments are not mechanistically related to a postulated accident scenario.
15
 
6.3.1.4 During the period of need for Type C instruments, no other failures shall be assumed in the analysis beyond the assumed breach of a barrier coincident with loss of off-site power; 0.3.2   Fuel Clad Barrier Monitoring 6.3.2.1 The measured variable shall detect and alarm the breach of the fuel clad barrier (i.e., > 1 percent fuel clad failure);
6.3.2.2 Operator sampling of reactor coolant shall be used as the means to verify the measured variable alarm.
6.3.2.3 The measured variable should be reactor coolant system radia-tion. The instrument range should be equivalent to the fuel clad gap activity corresponding to 0.5% to 5% failed fuel. A narrow accuracy band for this measured variable is not signi-ficant in achieving this function; for example, +50%, to +100%
accuracy of reading should be acceptable. instrument tran-sient response should be compatible with its recorder.
5.3.3   Reactor Coolant System Pressure Boundary Monitoring 6.3.3.1 The measured variable(s) shall detect and alarm a breach of the reactor coolant system that produces a loss of coolant inventory in excess of normal makeup capability. The spectrum of RCS pressure boundary breaches extends up to and includes the largest double-ended pipe break.
0.3.3.2 The means used to detect RCS pressure boundary breach should include one RCS pressure boundary variable and one containment variable over the full spectrum of break sizes.
6.3.3.3 The measured PWR variables should be RCS pressure and contain-ment pressure. The instrument range should be the design pressure plus a specified margin (< 1O%). Normal instrument accuracy is acceptable for these monitors. instrument tran-sient response should be compatible with its recorder.
16
 
6.3.3.4 The measured BWR variables should be drywell pressure and containment sump level. The instrument range should be design values plus a specified margin (< 10%). Normal instrument accuracy is acceptable for these monitors. Instrument tran-sient response should be compatible with its recorder.
6.3.4   Containment Pressure Boundary Monitoring 6.3.4.1 The measured variable(s) shall detect and alarm a breach of the containment pressure boundary that is capable of producing radiation releases in excess of 10 CFR 100 at the site boundary using TID-14844 source terms.
0.3.4.2 The means used to detect containment pressure boundary breach should include containment pressure (BWR and PWR), environs radiation monitoring for gross gamma (PWR), and secondary containment air space radiation monitoring for gross gamma (BWR).
6.3.4.3 The instrument range for containment pressure should be design pressure plus a specified margin (< 10%). Normal instrument accuracy is acceptable for this monitor. Instrument transient response should be compatible with its recorder.
6.3.4.4 The instrument range for environs radiation monitoring should be 10-3 to 102 R/hr. The instrument range for secondary containment air space radiation monitoring should correspond to the 10 CFR 100 value for off-site doses. Instrument accuracy should be + 1/2 decade (100 Kev-3 Mev). Instrument transient response should be compatible with its recorder.
6.3.5   Potential Breach of the Final Fission Product Barrier 6.3.5.1 The measured variables should be containment pressure, con-tainment hydrogen concentration, and RCS pressure for indicating the potential for causing a breach of the final fission product barrier (i.e., containment).
17
 
0                                 0 5.3.5.2   An arbitrary range of 3 times design pressure for concrete and 4 times design pressure for steel should be used for contain-ment pressure. Instrument accuracy should be + 10% of span.
Instrument transient response should be compatible with its recorder.
6.3.5.3   An arbitrary range of 0-10 volume percent hydrogen should be used for containment hydrogen concentration. Instrument accuracy should be + 10% of span. Instrument transient response should be compatiable with its recorder.
6.3.5.4   An arbitrary range of 1.5 times design pressure should be used for RCS pressure. Instrument accuracy should be + 10% of span. Instrument transient response should be compatible with its recorder.
6.3.6     INSTRUMENT QUALIFICATION 6.3.6.1   Type C instruments shall be qualified in the same manner as Type A instruments except:
6.3.5.1.1 For purposes of equipment qualification, the assumed maximum value of the monitored parameter shall be the value equal to the maximum range for the instrument. The monitored parameter shall be assumed to approach this peak by extrapolating the most severe initial ramp associated with the Design Basis Accidents. The decay for this parameter shall be considered proportional to the decay for this parameter associated with the Design Basis Accidents. No additional qualification margin needs to be added to the extended range parameter. See figure 6.3-1. All environmental envelopes except that per-taining to the parameter measured by the instrument shall be those associated with the Design Basis Accidents.
5.4       SPECIFIC DESIGN CRITERIA Design Criteria specific to particular accident phases and variable types are presented in Table 6.4-1.
18
 
TABLE 6.4.1 DESIGN CRITERIA PHASE 1                          PHASE II VARIABLE TYPE                    VARIABLE TYPE CRITERION                   A        B              C        A      B            C Yes                                Yes    No            No l.. Qualify seismically to IEEE 344-75 Yes            No 0
(operate after SSE)
: 2. Meet single failure     Yes      Yes            No        Yes    Yes          No per IEEE 379-77
: 3. Qualify environmen-     Yes      Yes            Yes(l)    Yes    Yes          Yes U )
tally to IEEE 323-74
: 4. Consider loss of         Yes      Yes            Yes        Yes    No            No off-site power 0
: 5. Power source,           Emergency Emerg.        Emerg. Emerg. Normal(6)    Normal (6).
: 6. Out of service interval (2)    .  (2)            <72 fir(3) (2)    (2)          <72 fIrs  3)
    - prior to accident
: 7. Otit of service inter- None      None          <2 hir    (2)    (2)          <2 hIrs val - during accident
 
TABLE 6.4-1     (Continued)
DESIGLN CRITERIA P11ASE 1                                  PHASE I I VARIABLE TYPE                             VARIABLE TYPE CRITERION                    A                B               C            A             B            C
: 8. Portable instrumenta-    No              No              INo(7)        Yes         Yes           Yes tiol
: 9. Level of quality          ANSI N45.2     ANSI t445.2    ANSI N45.2   ANSI N45.2   ANSI N45.2   ANSI N45.2 assurance
: 10. Display type(4)           Continuous      Contifluou s    Continuous    Continuous  Continuous    On demand
: 11. Display method            Recording(5)   Recorddi ng      Indicator    Recording(5) Indicator    Indicator
: 12. Identification as        Yes            Yes              Yes          Yes          Yes          Yes accident monitoring type
: 13. Periodic Test per        Yes            Yes            Yes          Yes          Yes          Yes IEEE-338-1977 NOTES:  (1) See Paragraph 6.3.6 of this Standard.
(2) IEEE 279-1971 Paragraph 4.11 Exemuption
 
NOTES TO TABLE 6.4-1 (Continued) 3? Based on normal tech spec requirements on out-of-service safety systems.
4 Continuous indication or recording displays a given variable at all times; intermittent indication or recording displays a given variable periodically; on demand indication or recording displays a given variable only when requested.
(5) Where trend or transient information is essential to planned operator actions.
(6) May be manually connected to emergency buss (7) Radiation monitoring outside containment may be portable.
-4
 
4 Figure 6.3-1. Typical Environmental Qualification Envelope for Type C Instruments e-  -    -      t I                  I Parameter          I                  i    k7 Assumied Parameter Environment I                    I I
I                       I
                                                    ---3,rDesiqn Basis Accident 0
Timee.}}

Latest revision as of 13:44, 22 March 2020

Proposed Revision 2 to Regulatory Guide 1.97, Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Plant and Environs Conditions During and Following an Accident, Draft 1
ML080390415
Person / Time
Site: Watts Bar  Tennessee Valley Authority icon.png
Issue date: 10/15/1979
From:
American National Standards Institute (ANSI)
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 7912060569
Download: ML080390415 (55)


Text

3 Draft 1 October 15, 1979 PROPOSED REVISION 2 TO REGULATORY GUIDE 1.97 INSTRUMENTATION FOR LIGHT-WATER-COOLED NUCLEAR POWER PLANTS TO ASSESS PLANT AND ENVIRONS CONDITIONS DURING AND FOLLOWING AN ACCIDENT A. INTRODUCTION Criterion 13, "Instrumentation and Control," of Appendix A, "General Design Criteria for Nuclear Power Plants," to 10 CFR Part 50, "Licensing of Production and Utilization Facilities," includes a requirement that instrumentation be provided to monitor variables and systems for accident conditions as appropriate to ensure adequate safety.

Criterion 19, "Control Room," of Appendix A to 10 CFR Part 50 includes a requirement that a control room be provided from which actions can be taken to maintain the nuclear power unit in a safe condition under accident conditions, including loss-of-coolant accidents and that equipment at appropriate locations outside the control room be provided with a design capability for prompt hot shutdown of the reactor including necessary instrumentation.

Criterion 64, "Monitoring Radioactivity Releases," of Appendix A to 10 CFR Part 50 includes a requirement that means be provided for monitoring the reactor containment atmosphere, spaces containing components for recirculation of loss-of-coolant accident fluid, effluent discharge paths, and the plant environs for radioactivity that may be released from postulated accidents.

This guide describes a method acceptable to the NRC staff for complying with the Commission's regulations to provide instrumentation to monitor plant variables and systems during and following an accident in a light-water-cooled nuclear power plant.

1.97-1 aK

B. DISCUSSION Indications of plant variables and status of systems important to safety are required by the plant operator (licensee) during accident situations to (1) provide information required to permit the operator to take pre-planned manual actions to accomplish safe plant shutdown; (2) determine whether the reactor trip, engineered-safety-feature systems, and manually initiated systems are performing their intended functions, i.e., reactivity control, core cooling, maintaining reactor coolant system integrity, and maintaining containment integrity; (3) provide information to the operator that will enable him to determine the potential for causing a breach of the barriers to radioactivity release (i.e.,

fuel cladding, reactor coolant pressure boundry and containment) and if a barrier has been breached; (4) furnish data for deciding on the need to take unplanned action if an automatic or manually initiated safety system is not functioning properly or the plant is not responding properly to the safety systems in operation; (5) allow for early indication of the need to initiate action necessary to protect the public and for an estimate of the magnitude of the impending threat.

At the start of an accident, it may be difficult for the operator to deter-mine immediately what accident has occurred or is occurring and, therefore, determine the appropriate response. For this reason, reactor trip and certain other safety actions (e.g., emergency core cooling actuation, containment isola-tion, or depressurization) have been designed to be performed automatically during the initial stages of an accident. Instrumentation is also provided to indicate information about plant parameters required to enable the operation of manually initiated safety systems and other appropriate operator actions involv-ing systems important to safety.

1.97-2

  • S Instrumentation is also needed to provide information about some plant parameters that will alert the operator to conditions that have degraded beyond those postulated in the accident analysis so that the operator can take actions that are available to mitigate the consequences. It is not intended that the operator be encouraged to circumvent systems important to safety prematurely, but that he be adequately informed in order that unplanned actions can be taken when necessary.

Examples of serious events that could threaten safety if conditions degrade beyond those assumed in the Final Safety Analysis Report are loss-of-coolant accidents (LOCAs), overpressure transients, ATWSs reactivity excursions, and releases of radioactive materials. Such events require that the operator under-stand, in a short time period, the ability of the barriers to limit radioactivity release, i.e., the potential for breach of a barrier, or an actual breach of a barrier by an accident in progress.

It is essential that the required instrumentation be capable of surviving the accident environment in which it is located for the length of time its func-tion is required as defined by ANS-4.-5, Section 3.0. It could therefore either be designed to withstand the accident environment or be protected by a local protected environment. If the environment surrounding an instrument component is the same for accident and normal operating conditions (e.g., some instrumen-tation components outside of containment or those in the main control room powered by a Class lE source), the instrumentation components need no special environmental qualification.

It is important that accident-monitoring instrumentation components and their mounts that cannot be located in other than non-Seismic Category I build-ings be conservatively designed for the intended service.

1.97-3

Parameters selected for accident monitoring can be selected so as to permit relatively few instruments to provide the essential information needed by the operator for postaccident monitoring. Further, it is prudent that a limited number of those parameters (e.g., containment pressure, primary system pressure) be monitored by instruments qualified to more stringent environmental require-ments and with ranges that extend well beyond that which the selected parameters can attain under limiting conditions. It is essential that the range selections not be arbitrary but sufficiently high that the instruments will always be on-scale; for example, a range for the containment pressure monitor extending to the burst pressure of the containment in order that the operator will not be blind as to the level of containment pressure. Provisions of such instruments are important so that responses to corrective actions can be observed and the need for, and magnitude of, further actions determined. On the other hand, we should also make sure that when a range is extended, the sensitivity and accu-racy of the instrument are within acceptable limits.

Normal power plant instrumentation remaining functional for all accident conditions can provide indication, records, and (with certain types of instru-ments) time-history responses for many parameters important to following the course of the accident. Therefore, it is prudent to select the required accident-monitoring instrumentation from the normal power plant instrumentation to enable the operator to use, during accident situations, instruments with which he is most familiar. Since some accidents impose severe operating requirements on instrumen-tation components, it may be necessary to upgrade those instrumentation components to withstand the more severe operating conditions and to measure greater variations of monitored variables that may be associated with the accident if they are to be 1.97-4

used for both accident and normal operation. However, it is essential that instru-mentation so upgraded does not compromise the accuracy and sensitivity required for normal operation. In some cases this will necessitate use of overlapping ranges of instruments to monitor the required range of the parameter to be monitored.

Draft Standard ANS-4.5, "Functional Requirements for Post Accident Monitoring Capability for the Control Room Operator of a Nuclear Power Generating Station,"

dated September 1979, delineates criteria for determining the variables to be monitored by the control room operator, as required for safety, during the course of an accident and during the long-term stable shutdown phase followng an accident.

Draft Standard ANS-4.5 was prepared by ANS 4 Working Group 4.5 with two primary objectives, (1) to address that instrumentation which permits the operator to monitor expected parameter changes in an accident period, and (2) to address extended range instrumentation deemed appropriate for the possibility of encounter-ing previously unforeseen events.

The standard defines four classifications of variable types for the purpose of aiding the designer in his selection of accident monitoring instrumentation and applicable criteria. (A fifth type (Type E) has been added by this regula-tory guide.) The types are, (1) Type A - those variables that provide-informa-tion needed for pre-planned operator actions, (2) Type B - those variables that provide information to indicate whether plant safety functions are being accom-plished, (3) Type C - those variables that provide information to indicate the potential for being breached or the actual breach of the barriers to fission product release, i.e., fuel cladding, primary coolant pressure boundary., and containment, (4) Type D - those variables that provide information to indicate the performance of individual safety systems, and (5) Type E - those variables to be monitored as required to provide defense-in-depth and for diagnosis and 1.97-5

other useful purposes. Type A variables have not been included in the listings of variables to be measured because they are plant specific and will depend upon the operations that the designer chooses for pre-planned manual action.

The five classifications are not mutually exclusive in that a given variable (or instrument) may be included in one or more types, as well as for normal power plant operation. Where such multiple listing occurs, it is essential that instrumentation be capable of meeting the most stringent requirements.

The time phases (Phases I, II, & III) delineated in ANS-4.5 are not speci-fied for each variable in this regulatory guide. These considerations are plant specific. It is important that the required instrumentation survive the accident environment and function as long as the information it provides is needed by the plant operator.

C. REGULATORY POSITION The criteria, requirements, and recommendations contained in Draft Standard ANS-4.5, "Functional Requirements for Post Accident Monitoring Capability for the Control Room Operator of a Nuclear Power Generating Station," dated September 1979, are considered by the NRC staff to be generally acceptable for providing instrumentation to monitor variables and systems for accident condi-tions and for monitoring the reactor containment, spaces containing components for recirculation of loss-of-coolant accident fluids, effluent discharge paths, and the plant environs for radioactivity that may be released during and follow-ing an accident from a nuclear power plant subject to the following:

(1) Section 2.0 of ANSI-4.5, defines the scope of the standard as contain-ing criteria for determining the variables to be monitored by the control room operator during and following an accident that will need some operator action.

1.97-6

Consideration should be given to the additional requirements (e.g., emergency planning) of variables to be monitored by the plant operator (licensee) during and following an accident. Instrumentation selected for use by the plant opera-tor for monitoring conditions of the plant are useful in an emergency situation and for other purposes and therefore should be factored into the emergency plans action level criteria.

(2) In Section 3.0 of ANS-4.5, the definition of "Type C" includes two items, (1) and (2). Item (1) includes those instruments that indicate the extent to which parameters, which indicate the potential for a breach in the containment, have exceeded the design basis values. In conjunction with the parameters that indicate the potential for a breach in the containment, the parameters that have the potential for causing a breach in the fuel cladding (e.g., core exit temperature) and the reactor coolant pressure boundary (e.g.,

reactor coolant pressure) should also be included. References to Type C instru-ments, and associated parameters to be measured, in Draft Standard ANS-4.5 should include this expanded definition, e.g., Section 4.2, Section 5.0c, Section 5.1.3, Section 5.2.2, Section 6.3.

(3) Section 3.0 of ANS-4.5 defines design basis accident events. In conjunction with the design basis accident events delineated in the standard, those events which are expected to occur one or more times during the life of a nuclear power unit and include but are not limited to loss of power to all recirculating pumps, tripping of the turbine generator set, isolation of the main condenser, and loss of all offsite power, should be included.

(4) Section 4.2 of ANS-4.5, discusses the various types of variables.

With regard to the discussion of Type D variables, Type 0 variables and instru-ments are within the scope of Accident Monitoring Instrumentation, although 1.97-7

they are not addressed in Oraft Standard ANS-4.5. They are, however, along with an additional type, Type E, included in this regulatory guide. (See Tables 1, 2 and 3)

(5) Section 5.2.1(5) of ANS-4.5 pertains to the delineation of the local environment in which instruments must operate. Section 5.2.1(5) should be understood to require identification of the range of the local physical and electrical environments (e.g., normal, abnormal, accident, and post-accident) in which all of the various instrumentation components are required to operate (e.g., sensors, cables, signal conditioning equipment, indicators).

(6) Section 5.2.2 of ANS-4.5 pertains to the performance requirements for Type C instrumentation. In conjunction with Section 5.2.2, there should be:.

(1) Identification of the range of the process variable. (Note -

the range selected should extend well beyond that which the variable value can attain under limiting conditions)

(2) Identification of the required accuracy of measurement (3) Identification of the required response characteristics (4) Identification of the time interval beginning with initiation of an accident to as long as the measurement is needed (5) Identification of the local environment (including energy supply) in which the various instrumentation components are required to operate.

(7) Section 6.1.1 of ANS-4.5, pertains to seismic qualification criteria.

In conjunction with Section 6.1.1, those instrumentation components which should be seismically qualified are identified in Table 1 of this regulatory guide.

(8) Section 6.1.1 of ANS-4.5, pertains, in part, to the consideration of vibrational loads. TIn conjunction with Section 6.1.1, those instrumentation 1.97-8

components which are subjected to vibrational loads that occur as a result of plant system operation during any phase for which the instrumentation is required should be qualified to function during and/or following such vibrational loads.

(9) Section 6.1.2 of ANS-4.5, pertains to the duration that instrumentation is qualified to function. In conjunction with Section 6.1.2, Phase II instrumen-tation should be qualified to function for not less than 200 days unless a shorter time, based on need or component accessability for replacement or repair, can be justified.

(10) Section 6.1.6 of ANS-4.5 pertains to instrumentation location and identification. In conjunction with Section 6.1.6, accident monitoring instru-mentation displays should be located in direct view of the plant operator and be distinguished from other displays. Other accident monitoring instrumentation components should be accessible to the plant operator for maintenance and repair although this may not be possible for some components in some accident conditions.

(11) Section 6.2.1 of ANS-4.5 pertains to general requirements for Type B instruments. In conjunction with Section 6.2.1, Type B instruments are essen-tial to meeting the requirements of Criterion 13 and Criterion 64 of Appendix A to 10 CFR Part 50 and are not considered to be an "extra set of instruments which result in an additional layer of protection." Type B instruments are essential to the monitoring of variables and systems during accident conditions and in following the course of an accident.

(12) Section 6.2.2, 6.2.3, 6.2.4, 6.2.5, 6.2.6, 6.3.2, 6.3.3, 6.3.4, and 6.3.5 of ANS-4.5 pertain to variables and variable ranges for monitoring. In conjunction with the above sections, Tables 1, 2 and 3 of this regulatory guide (which includes those parameters mentioned in the above sections) should be used in developing the minimum set of instruments and their respective ranges for accident monitoring instrumentation for each nuclear power plant.

1.97-9

(13) Sections 6.3.2.3, 6.3.3.3, 6.3.3.4, 6.3.4.3, 6.3.4.4, 6.3.5.2, 6.3.5.3, and 6.3.5.4 of ANS-4.5 pertain, in part, to instrument transient response and relate this to compatability with recorder capabilities. In conjunction with the above sections, the transient response requirements of each measurement should be determined on a case-by-case basis by analysis of the event and operator response capabilities.

(14) Sections 6.3.3.3, 6.3.3.4, and 6.3.4.3 of ANS-4.5, pertain, in part, to measurement accuracy. In conjunction with the above sections, the accuracy of each measurement should be consistent with the requirements as established by analysis of the event being monitored.

(15) Section 6.3.6.1.1 ANS-4.5 pertains, in part, to the qualification of Type C instrumentation components. In conjunction with Section 6.3.6.1.1, the environmental envelope for qualification should be the extreme value of each environmental parameter, except the variable being monitored, as determined by the accident analysis for all accidents evaluated in the safety analysis of the plant.

(16) Table 6.4.1 of ANS-4.5 pertains to design criteria for accident monitoring instrumentation. In conjunction with Table 6.4.1, the provisions as indicated in Table 1 of this regulatory guide should be used.

D. IMPLEMENTATION This proposed revision has been released to encourage public participation in its development. Except in those cases in which an applicant proposes an acceptable alternative method for complying with specified portions of the Commission's regulations, the method to be described in the active guide reflect-ing public comments will be used in the evaluation of the following applica-tions that are docketed after the implementation date to be specified in the guide:

1. 97-10
  • 0 P
1. Preliminary Design Approval (PDA) applications and Preliminary Duplicate Design Approval (PDA) applications.
2. Final Design Approval, Type 2 (FDA-2), applications and Final Duplicate Design Approval, Type 2 (FDDA-2), applications.
3. Manufacturing License (ML) applications.
4. Construction Permit (CP) applications except for those portions of CP applications that reference standard designs (i.e., PDA, FDA-1, FDA-2, PDDA, FDDA-1, FDDA-2, or ML) or that reference qualified base plant designs under the replication option.

In addition, the NRC staff intends to implement part or all of this guide for all operating plants, plants under construction, all PDA's and FDA's, all PDDA's and all FDDA's which may involve additions, elimination, or modification of structures, systems, or components of the facility after the construction permit, or design approval has been issued. All backfitting decisions in accordance with the positions stated in this guide will be determined by the staff on a case-by-case basis.

The implementation date of this guide will in no case be earlier than

1. 97-11
  • TABLE 1 - DESIGN CRITERIA' 0 CRITERIA INSTRUMENTATION TYPES 2 A B C D E
1. Seismic Qualification yes yes yes no per Reg Guide 1.100 no
2. Single Failure Criteria yes yes yes no per Reg Guide 1.53 no
3. Environmental Qualification yes yes yes3 yes per Reg Guide 1.89 no4
4. Consider loss of off-site yes yes yes yes yes power
5. Power source Emr5 CB6 CB6 Emr 5 Emrs
6. Out of service interval 7 7 7 before accident 8 13
7. Portable no no no10 no10 nolo
8. Quality assurance level 11 11 11 11 11
9. Display type 12 Con 13 Con 13 Con 13 OD14 OD14.
10. Display method Rec 15 Rec1 6 Rec 1 6 Ind17 Ind7, 18
11. Unique identification yes yes yes no no
12. Periodic testing per yes yes yes yes no Reg Guide 1.118 NOTES for Table 1: (1) Unless different specifications are given in this regulatory guide, the specifications in ANSI N320-1979, "Performance Specif 'ications for Reactor Emergency Radiological Monitoring Instru mentation," apply to the high-range containment area monito rs, area exposure rate monitors in other buildings, efflueent and environmental monitors, and portable instruments for measuring radiation or radioactivity.

(2) Type A - Those instruments which provide information required to take pre-planned manual actions.

Type B - Those instruments which provide information to monitor the process of accomplishing critical safety functions.

Type C - Those instruments that indicate the potential for breach-ing or the actual breach of the barriers to fission pro-duct release.

Type D - Those instruments that indicate the performance of in-dividual safety systems.

Type E - Those instruments that provide information for defense-in-depth and for diagnosis or other useful purposes.

1.97-12

0 NOTES for Table 1 continued: (3) -See Paragraph 6.3.6 of Draft Standard ANS-4.5.

(4) Qualified to the conditions of fts operation.

(s) Emergency power source.

(6) Critical Instrument Buss - Class 1E Power.

(7) IEEE 279-1971 Paragraph 4.11, "Exemption".

(8) Based on normal tech spec requirements on out-of-service for the safety system it serves.

(9) Not necessary to include in tech specs.

(10) Radiation monitoring outside containment may be portable if as designated.

(11) Level of quality assurance per 10 CFR Part 50, Appendix B.

(12) Continuous indication or recording displays a given variable at all times; intermittent indi-cation or recording displays a given variable periodically; on demand indication or recording displays a given variable only when requested.

13 ) Continuous display.

(14) Indication on demand.

(15) Where trend or transient information is essential to planned operator actions.

(16) Recording.

(1?) Dial or digital indication.

CIS) Effluent release monitors require recording, in-cluding effluent radioactivity monitors, environs exposure rate monito-rs, and meteorology monitors.

1.97-13

TABLE 2 - P':!R VIARIABLES 0

Measured Variable Rance Tvne I D. *t -

-- § Buy-  ! r puz CORE

Core Exit Temperature 150 0 F to 2300aF B,C ANS-4.5, Section 6.2.3 Provide incore temperature measurements to identify localized hot areas.

(Approximately 50 measurements)

Control Rod Position Full in or not full D Provide positive indication that the con-in trol rods are fully inserted.

(Minimum 5 days after accident)

Neutron Flux 1 c/s to 1% power E ANS-4.5, Section 6.2.2 (at least one fission For indication of approach to criticality.

counter)

REACTOR COOLANT SYSTEM:

RCS Hot Leg Temper- 150 0 F to 750aF ANS-4.5, Section 6.2.3 ature To aid in determining reactor system sub-cooling and to provide indication of natural circulation.

RCS Cold Leg Temper- 130*F to 7500 F B ANS-4.5, Section 6.2.3 ature To provide indication of natural circula-tion; to provide input for heat balance calculations; for direct indication of ECCS injection.

RCS Pressure 15 psia to 4000 psig BC AVNS-4.5, Sections 6.2.3 and 6.2.4 For indication of an accident and to in-dicate that actions must be taken to mitigate an event.

Pressurizer Level Bottom tangent to B,D ANS-4.5, Section 6.2.3 top tangent Level indication is required to assure proper operation of the pressurizer and to assure safe operation of heaters. It is also used in conjunction with changes in reactor pressure to determine leak and void sizes.

Degree of Subcooling 200OF subcooiing to For indication of margin in core cooling 3 50 F superheat and the need for emergency coolant addi-tions or reductions as the margin changes and to obviate the necessity to consuit steam tables.

1.97-14

TABLE 2 - PWR VARIABLES continued -

Measured Variable Range Typee Piirnnose

-- 1 P urwnw REACTOR COOLANT SYSTEM CONTINUED:

Reactor Coolant Loop 0 to 120%)) des B,D To provide indication that the core is Flow -20% to 20%J' flogw being cooled.

Primary System Safety Closed-not closed B,D By these measurements the operator knows Relief Valve Posi- if there is a path open for loss of cool-tions or Flow Through ant and that an event may be in progress.

or Pressure In Relief Valve Lines Radiation Level in 10 uCi/g to 10 Ci/g C ANS-4.5, Section 6.3.2 Primary Coolant Watei For early indication of fuel cladding failure and estimate of extent of damage.

CONTAINMENT:

Containment Pressure 10 psia pressure to B,C ANS-4.5, Sections 6.2.5, 6.3.3, 6.3.4, 3 times design press- and 6.3.5 ure 2 for concrete; 4. For indication of the integrity of the times design pressure primary or secondary system pressure for steel boundaries. To indicate the potential for leakage from the containment; to indicate integrity of the containment.

Containment Atmos- 40*F to 400*F E For indication of the performance of the phere Temperature containment cooling system and adequate mixing.

Containment Hydrogen 0 to 10% B,C ANS-4.5, Sections 6.2.5 and 6.3.5 Concentration (capable of operating For indication of the need, and to meas-from 10 IDsia to ure the performance of the containment maximum cdesign press- hydrogen recombiner.

ure 2 Containment Isola- Closed-not closed B,D ANS-4.5, Section 6.2.3 tion Valve Position To indicate the status of containment isolation and to provide information on the status of valves in process lines which could carry radioactive materials out of containment.

1.97-15

TABLE 2 - PWR VARIABLES continued -

Measured Variable Range I Type I

r Type Puroose CONTAINMENT CONTINUED:

Containment Sump Narrow range (sump) BC For indication of leakage within the Water Level Wide range (bottom of containment and to assure adequate in-containment to 600,000 ventory for performance of the ECCS.

gallon level equiva-lent)

High Range Contain- 1 to 107 R/hr (60 keV B,C For implementation of GDC 64 and to help ment Area Radiation to 3 MeV photons identify if an accident has degraded be-with +20% accuracy for yond calculated values and to indicate photons of 0.1 to 3 its magnitude to determine action to MeV)[107 R/hr for pho- protect the public.

tons is approximately equivalent to 108 rads per hour for betas and photons]

SECONDARY SYSTEMiS:

Steam Generator From pressure for D For indication of integrity of the sec-Pressure safety valve setting ondary system, and an indication of cap-to plus 20% of safety ability for decay heat removal.

valve setting Steam Generator Level From tube sheet to D For indication of. integrity of the sec-separators ondary system, and an indication of cap-ability for decay heat removal.

Auxiliary Feedwater 0 to 110% design flow1 D To indicate an adequate source of water Flow to each steam generator upon loss of main feedwater.

Main Feedwater Flow 0 to 110% design flow 1 To indicate an adequate source of water E

to each steam generator.

Safety/Relief Valve Closed-not closed B,D To Indicate integrity of secondary Positions or Main system (vis--a-vis pipe break).

Steam Flow Radiation in Condenser 10-7 to 105 Ci/cc Air Removal System To indicate leakage from the primary to the secondary system and measure of noble gas release rate to atmosphere.

Radioactivity in Efflu- 10-7 to lo05 ;1Ci/cc B,C An indication of release from the ent from Steam Gener-secondary system and measure of noble ator Safety Relief Valves or Atmospheric gas release rate to atmosphere.

Dump Valves 1.97-16

TABLE 2 - POR VARIABLES con Olued - .

Measured Variable Range Type Purcose-

;I;o T

AUXILIARY SYSTEMS:

Containment Spray O to 110% design flow2 For indication of system operation.

D Flow Flow in HPI System 0 to 110% design flow' For indication of system operation.

D Flow in LPI System 0 to 110% design flow1 For indication of system operation.

D Emergency Coolant Top to bottom To determine the amount of water dis-Water Storage Tank D charged by the ECCS. This provides in-Level dication of the nature of the accident, indication of the performance of the ECCS, and indication of the necessity for operator action.

Accumulator Tank Top to bottom To indicate whether the tanks have in-Level D jected to the reactor coolant system.

Accumulator Isolation Closed-not closed To indicate state of the isolation Valve Positions D valves. (Per Regulatory Guide 1.47)

RHR System Flow 0 to 110% design flow1 For indication of system operation.

D RER Heat Exchanger 320 F to 3500 F For indication of system operation.

D Out Temperature Component Cooling 320 F to 200*F For indication of system ope.ration D

Water Temperature Component Cooling 0 to 110% design flow1 For indication of system operation.

D Water Flow Flow in UHS Loop 0 to 110% design flow1 For indication of system operation.

D Temperature in Ulti- 30°F to 1500 F For indication of system operation.

D mate Heat Sink Loop Ultimate Heat Sink Plant specific D To ensure adequate source of cooling Level water.

Eeat Removal by the Plant specific to indicate system operation B

Containment Fan Coolers Boric Acid Charging 0 to 110% design flow1 B To provide indication of reactor cooling Flow and inventory control and maintain ade-quate concentration for shutdown margin.

1.97-17

TABLE 2 -

S PWR VARIABLES continued -

0 Measured Variable Ranqe Tvop Plirmnen

_ _ - fI -- I - -.- ~W41 AUXILIARY SYSTEMS CONTINUED:

Letdown Flow 0 to 110% design flowl D For indication of reactor coolant inven-tory control and boron concentration control.

Sump Level in Spaces To corresponding level To monitor environmental conditions of of Equipment Required D of safety equipment equipment in closed spaces.

for Safety failure RADWASTE SYSTEMS:

High Level Radioactive Top to bottom Available volume to store primary coolant-Liquid Tank Level E Radioactive Gas Hold- 0 to 150% of design Available capacity to store waste gases.

up Tank Pressure pressure 2 VENTILATION SYSTEMS:

Emergency Ventilation Open-closed status D To ensure proper ventilation under Damper Position accident conditions.

Temperature of Space 300 F to 180°F D To monitor environmental conditions of in Vicinity of Equip- equipment in closed spaces.

ment Required for Safety POWER SUPPLIES:

Status of Class IE Voltages and currents D To ensure an adequate source of electric Power Supplies and power for safety systems.

Systems Status of Non-Class Voltages and currents indicate an adequate source of elec-K It lE Power Supplies tric power.

and Systems 1.97-18

TABLE 2 - PWR VARIABLES continued - .

Measured Variable Ranqe I I Tvoe T v o-e Piirnmca I ma -P RADIATION EXPOSURE RATES INSIDE BUILDINGS OR AREAS WHERE ACCESS IS REQUIRED TO SERVICE SAFET7 RELATED EQUIPMENT Radiation Exposure 10-1 to 104 R/hr for For measurement of high-range radiation Rates photons exposure rates at various locations.

(permanently install-ed monitors)

AIRBORNE RADIOACTIVE MAT.

ERIALS RELEASED FROM THE PLANT:

Effluent Radioactiv- (Normal plus accident ANS-4.5 Section 6.2.6 ity - Noble Gases range for noble gas) To provide operator with information

-Containment -7 to 105 .Ci/cc regarding release of radioactive noble Xe-133 calibration gases on a continuous basis.

-Secondary Contain- 10-7 to 104 11Ci/cc ment Xe-133 calibration

-Auxiliary Building 10-7 to 103 uCi/cc including building containing primary system gases, eg.

waste gas decay tank

.Other Release 10-7 to 102 vICi/cc Points (including fuel handling area (permanently install-if separage from ed monitors) auxiliary building Effluent Radioactiv- To provide the operator with information ity - High Range regarding release of radioactive halogens Radiohalogens and and particulates. Continuous collection Particulates of representative samples followed by

-Untreated Effluents 10-3 to 102 4Ci/cc monitoring (measurements) of samples for radiohalogens and for particulates.

.HEPA Filters, min- '0-3 to 10 .Ci/cc imum of 2" of TEDA impregnated char-coal, non-ESF sys-tems

.HEPA Filters, min- 10-3 to 1 .Ci/cc imuni of 4" of TEDA impregnated char- (permanently install-coal, ESF systems ed monitors) 1.97-19

TABLE 2 - PWR VARIABLES con*ued -

Measured Variable Rance_ I Tvn0a

  • oe I _ _ __ __I _ _ _ ,, A- I
  • u I uz e AIRBORNE RADIOACTIVE MAT-ERIALS RELEASED FROM THE PLANT CONTINUED:

Environs Radioactiv- lO3 to 102 R/hr For estimating release rates of radio-ity - High Range (60 keV to 3 MeV) active materials released during an Exposure Rate accident from unidentified release paths (permanently install-ed monitors) (not covered by effluent monitors) -

continuous readout capability, approxi-mately 16 to 20 locations - site de-pendent.

Environs Radioactiv- 10-9 to 10-3 4Ci/cc E For estimating releases rates of radio ity - Radiohalogens for both radiohalogens active materials released during an and Particulates and particulates accident from unidentified release oaths (permanently install- (not covered by effluent monitors).

ed monitors) Continuous collection of representative samples followed by monitoring (measure-ments) of the samples. (Approximately 16 to 20 locations)

AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM THE PLANT CONTINUED:

Plant and Environs Normal Range During and following an accident, to mc-.

Radioactivity 0.1 to 104 mR/hr itor radiation and airborne radioactivi (portable instruments photons concentrations in many areas throughout 10-9 to O14 4C4/cc the facility where is impractical to particulates install stationary monitors capable of covering both normal and accident level:

10-9 to 10-4 UCi/cc iodine High Range 0.1 to 104 R/hr photo-as 0.1 to 104 rads/hr betas and low energy photons lO-channel gamra-ray During and following an accident to rap-spectrometer idly scope the composition or ga-a-emitting sources.

1.97-20

TABLE 2 - PWR VARIABLES contoed -

Measured Variable Range Tvaho pi1on I I- - j 'Al IJS.JQ, POST-ACCIDENT SAMPLING I-CAPABILITY:

Primary Coolant As required based on ZWA Provide means for safe and convenient Sumps Reg Guide 1.4 guide- sampling. These provisions should Containment Air lines include:

1. shielding to .maintain radiation doses ALARA,
2. sample containers with container-POST-ACCIDENT ANALYSIS 1. gamma-ray spectrum CAPABILITY (ONSITE): sampling port connector comnatibili '
2. pH 3. capability of sampling under primary
3. hydrogen system pressure and negative pressur
4. oxygen 4. handling and transport capability, a:

S. boron 5. pre-arrangement for analysis and interpretation.

ifETEOROLOGY:

Wind Direction 0 to 360° (+/-5' accur- E For determining affluent transport direc-acy with a deflection tion for emergency planning, dose assess-of 15G. Starting speed ment, and source estimates.

0.45 mps (1 mph)

Wind Speed 0 to 30 mps (67 mph) For determining effluent travel speed anc

(*0.22 mps (0.5 mph) dilution for emergency planning,, doses accuracy for wind spee assessments and source estimates.

less that 11 mps (25 m ph), with a starting threshold of less than 0.45 mps (1 mph)

-90F to +90 F (+/-0.3 0 F Vertical Temperature Difference accuracy per 164 foot E I For determining effluent diffusion rates for emergency planning, dose assessments intervals and source estimates.

Precipitation Recording rain gage For determining effluent transport and with range sufficient ground deposition for emergency planning.

to assure accuracy of total accumulation within iO% of record-ed value - 0.01" resolution Notes for Table 2 -

(1) Design flow - the maximum flow anticipated in normal operation.

(2) Design pressure - that value corresponding to AS1LE code values which are obtained at or below code allowable material design stress values.

1. 97-21

0 .

TABLE 3 - BWR VARIABLES Measured Variable Range Ty pe Puirnnos I -. i CORE:

Control Rod Position Full in or not full D Provide positive indication that the in control rods are fully inserted.

(Minimum of 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> after accident)

Neutron Flux 1 c/s to 1% power B ANS-4.5, Section 6.2.2 (at least one fission For indication of approach to criticality counter)

REACTOR COOLANT SYSTEM:

RCS Pressure 15 psia to 2000 psig B,C ANS-4.5, Sections 6.2.3, 6.2.4, 6.3.3 and 6.3.5 For indication of an accident and to in-dicate that actions must be taken to mitigate an event.

Coolant Level in the Bottom of core support B ANS-4.5, Section 6.2.3 Reactor plate to above top of For indication of fuel submergency for discharge plenum a LOCA event.

Main Steamline Flow 0 to 120% design flow1 B To provide an indication of the integrity of the pressure boundary.

Main Steamline Isola- 0 to 15" of water B To provide an indication of the pressure tion Valves' Leakage 0 to 5 psid boundary and containment integrity.

Control System Press-ure Primary System Safety Closed-not closed B,D By these measurements the operator knows Relief Valve Posi- or if there is a path open for loss of cool-tions including ADS 0 to 30 psig ant and that an event may be in progress.

or Flow Through or Pressure in Valve Lines Radiation Level in 10 pCi/g to 10 Ci/g C ANS-4.5, Section 6.3.2 Coolant For early indication of fuel cladding failure and estimate of extent of damage.

1.97-22

TABLE 3 - BWR VARIABLES continued -

Measured Variable Range Type Purnosp

- T Ir--o CONTAINMENT:

Primary Containment 10 psia pressure to BC ANS-4.5, Sections 6.2.5, 6.3.3, 6.3.4, Pressure 3 times design press- and 6.3.5 ure2 for concrete; 4 For indication of the intergrity of the times design pressure primary containment pressure boundary; for steel to indicate the potential for leakage from the containment.

Containment and Dry- 0 to 10% B,C ANS-4.5, Sections 6.2.5, and 6.3.5 well Hydrogen (capability of oper- For indication of the need for, and a Concentration ating from 12 psia to measurement of the performance of the maximum design press- containment hydrogen recombiner and to ure 2 verify the operation of the mixing system Containment Isolation Closed-not closed B,D ANS-4.5, Section 6.2.5 Valve Position To indicate the status of containment isolation and to provide information on the status of valves in process lines which could carry radioactive materials out of containment.

£ Suppression Pool Top of vent to top of B ANS-4.5, Section 6.3.3 Water Level weir well Suppression Pool 500 F to 2500 F 3 To assure proper temperature~for NPSH of Water Temperature ECCS. To verity the operation of the makup system.

Drywell Pressure 12 psia to 3 psig B ANS-4.5. Section 6.3.3 o to 110% design E Diagnosis of impact of accident on dr7-pressure well structure.

Drywell Drain Sumps Bottom to top B,C ANS-4.5, Section 6.3.3 Level (Identified and Unidentified Leakage)

High Range Contain- 1 to 107 R/hr B,C To help identify if an accident has de-ment Area Radiation (60 keV to 3 MeV pho- graded beyond calculated values and in-tons with +/-20% acc- dicate its magnitude and to determine uracy for photons of action to protect the public.

0.1 to 3 MeV)[ 10' R/hr for photons is approximately equiva-lent to 108 rads/hr for betas and photons]

1.97-23

TABLE 3 - 8WR VARIABLES contin9 d -

Measured Variable I Range Tvoe Piironca v tI POWER CONVERSION SYSTEMS Main Feedwater Flow O to 110% design flow1 E To indicate an adequate source of water to the reactor.

Condensate Storage Bottom to top E To indicate available water for core Tank Level cooling.

AUXILIARY SYSTEMS:

Containment Spray O to i10% design flow1 D For indication of system operation.

Flow Steam Flow to RCIC O to 110% design flowl To verify that adequate steam is avail-able for the system to perform its function.

RCIC Flow 0 to 110% design flow 1 For indication of system operation.

RHR System Flow 0 to 110% design flow1 For indication of system operation.

RHR Heat Exchanger 32 0 F to 350 0 F For indication of system operation.

Outlet Temperature Service Cooling 320 F to 2000 F For indication of system operation.

Water Temperature o ai Service Cooling O to 110% design flow1 For indication of system operation.

Water Flow Flow in UHS Loop 0 to 110% design flow 1 For indication of sys tem operation.

Temperature in Ulti- 30 0 F to 150 0 F For indication of system operation.

mate Heat Sink Loop Ultimate Heat Sink Plant specific To ensure adequate source of cooling Level - water.

SLCS Storage Tank Bottom to top To provide indication of inventory fcr Level boron injection for shutdown.

Sump Level in Spaces To corresponding level To monitor potential for failure of of Equipment Required of safety equipment equipment in closed spaces due to for Safety failure flooding.

1.97-24

TABLE 3 - BWR VARIABLES co nued -

Measured Variable Range Type Piurnnca

- __I

_ _ _ - d .- I I I I RADWASTE SYSTEMS:

High Radioactivity Top to bottom Available volume to store primarv Liquid Tank Level coolant.

Charcoal Delay Gas As required To monitor performance of system.

System Gas Flow or Radioactivity Level VENTILATION SYSTEMS:

Emergency Ventilatioi Open-closed status To ensure proper ventilation under Damper Position accident conditions.

Temperature of Space 300 F to 1300 F To monitor environmental conditions of in Vicinity of Equi- equipment in closed spaces.

pment Required for Safety POWER SUPPLIES:

Status of Class lE Voltages and currents To ensure an adequate source of electric Power Supplies and power for safety systems Systems Status of Non-Class Voltages and currents To indicate an adequage source of lE Power Supplies electric power.

and Systems RADIATION EXPOSURE RATES INSIDE BUILDINGS OR AREAS WHERE ACCESS IS REQUIRED TO SERVICE SAFETY RELATED EQUIP-MENT:

Radiation Zxposure 101- to 10 R/hr for For measurement of high-range radiation Rates photons exposure rates 2a various locations.

(permanently install-ed monitors) 1.97-25

TABLE 3 - BWR VARIABLES coriued -

Measured Variable Range Type Puroose Pu ro as e AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM THE PLANT:

Effluent Radioactiv- (Normal plus accident ANS-4.5, Section 6.2.6 ity - Noble Gases range for noble gas) To provide operator with information re-

.Containment Exhaust garding release of radioactive noble 10-7 to 105 llCi/cc Vent and St andby gases on a continuous basis.

Xe-133 calibration Gas Treatment Sys-tem Vent

-Other Release l0-7 to 102 PCi/cc Points [including Xe-133 calibration fuel handling bui-lding, auxiliary (permanently install-building, and tur- ed monitors) bine building]

Effluent Radioactiv- E To provide the operator with information ity - High Range regarding release of radioactive halogens Radiohalogens and and particulates. Continuous collection Particulates of representative samples followed by

.Untreated EffluentE monitoring (measurements) of samples for 10-3 to 102 lCi/cc radiohalogens and for particulates.

.HEPA Filters, min- 10-3 to 10 vCi/cc imum of 2" *of TEDA impregnated char-coal, non-ESF sys-tems

.HEPA Filters, min- 10-3 to 1 PCi/cc imum of 4" of TEDAi impregnated char- (permanently install-ed monitors) coal, ESF systems Environs Radioactiv- 10-3 to 102 R/hr For estimating release rates of radio-ity - High Range (60 keV to 3 MeV) active materials released during an Exposure Rate accident from unidentified release paths (permanently install-ed monitors) (not covered by effluent monitors) -

continuous readout capability, approxi-mately 16 to 20 locations - site de-pendent.

Environs Radioactiv- 10-9 to 10-3 Ci/cc E For estimating releases rates of radio-ity - Radiohalogens for both radiohalogens active materials released during an and Particulates and particulates accident from unidentified release paths (permanently install- (not covered by effluent monitors).

ed monitors) Continuous collection of representative samples followed by monitoring (measure-ments) of the samples. (Approxi ately 16 to 20 locations)

1. 97-26

TABLE 3 - BWR VARIABLES co ued -

Measured Variable Range Type Puroose Pu ro Os e AIRBORNE RADIOACTIVE MATERIALS RELEASES FROM1 THE PLANT CONTINUED:

Plant and Environs Normal Ranae E During and following an accident, to mon-Radioactivity 0.1 to 10mR/hr itor radiation and airborne radioactivity (portable instruments photons concentrations in many areas throughout the facility where is impractical to 10-9 to 10-4 11Ci/cc particulates install stationary monitors capable of covering both normal and accident levels.

10-9 to 10-4 4Ci/cc iodine High Range 0.1 to 104 R/hr photons 0.1 to 104 rads/hr betas and low energy photons 100-channel gamma-ray During and following an accident to rap-spectrometer idly scope the composition of gamma-emitting sources.

POST-ACCIDENT SAMPLING CAPABILITY:

Primary Coolant As required based on N/A Provide.means for safe and convenient Suppression Pool Reg Guide 1.3 guide- sampling. These provisions should Containment Air lines include:

1. shielding to maintain radiation doses ALARA,
2. sample containers with container-POST-ACCIDENT ANALYSIS 1.- gamma-ray spectrum N/A sampling port connector compatibility.

CAPABILITY (ONSITE): 2. pH 3. capability of sampling under primary

3. hydrogen system pressure and negative pressure
4. oxygen 4. handling and transport capability, ark
5. pre-arrangement for analysis and interpretation.

METEOROLOGY:

Wind Direction 0 to 360° (+/-50 accur- E For determining affluent transport direc-acy with a deflection tion for emergency planning, dose assess-of 150. Starting speed ment, and source estimates.

0.45 mps (1 mph)

Wind Speed 0 to 30 mps (67 mph) E For determining effluent travel speed and

(+/-0.22 mps (0.5 mph) dilution for emergency planning,, doses accuracy for wind speeI S assessments and source estimates.

less that 11 mps (25 m on), with a starting threshold of less than 0.45 mps (1 mph) 1.97-27

TABLE 3 - 8WR VARIABLES cifinued -

0 Measured Variable Range I__IT/Os

- _I -_ _ I_ __

of1'M en WI U ft CZ I

MEETEOROLOGY CONTINUED:

Vertical Temperature -9*F to +90 F (tO.307 For determining effluent diffusion rates Difference accuracy per 164 foot for emergency planning, dose assessment C intervals and source estimates.

Precipitation Recording rain gage E For determining effluent transport and with range sufficient ground deposition for emergency planning to assure accuracy of total accumulation within 1O% of record-ed value - 0.01" resolution Notes for Table 3 -

(1) Design flow - the maximum flow anticipated in normal operation.

(z) Design pressure - that value corresponding to ASM code values which are obtained at or below code allowable material design scress values.

1. 97-28

0 0 ANS-4. 5 Draft 3 September, 1979 DRAFT CAUTION NOTICE: This Standard is being prepared or reviewed and has not been approved by ANS. It is subject to revision or withdrawal before issue.

09 DRAFT American National Standard FUNCTIONAL REQUIRE1ENTS FOR POST ACCIDENT MONITORING CAPABILITY FOR THE CONTROL ROOM OPERATOR OF A NUCLEAR POWER GENERATING STATION Assigned Correspondent

- T. F. Timmons Westinghouse Electric Corporation Power Systems Company P.O. Box 355, MNC-410 Pittsburgh, PA 15230 Writing Group ANS 4.5 Standards Committee NUPPSCO Secretariat ANS

0 0 TABLE OF CONTENTS FOREWORD 1.0 Introduction 2.0 Scope 3.0 Definition 4.0 Discussion 5.0 Design Basis 6.0 Design Criteria - Phase I and Phase II

FOREWORD ANS 4 established Working Group 4.5 in late July 1979 to prepare a draft standard on Accident Monitoring Instrumentation which would complement other standards, but be broader in nature by including economic consid-erations. Two primary objectives were 1) to address that instrumenta-tion which permits the operator to monitor expected parameter changes in the accident period, and 2) to address extended range instrumentation deemed appropriate for the possibility of encountering previously unforeseen events.

ANS 4.5 began work on July 30th and met for 13 working days in a seven week period. In addition, a Design Criteria subgroup met for two days in this same period.

As presented, this draft standard provides:

1. a list of functions to be performed (design basis section 5.0)
2. a framework to determine those variables to be monitored (design basis section 5.0)
3. an identification of three time periods of interest (definitions 3.0)
4. an identification of four variable types (definitions 3.0)
5. a delineation of applicable design criteria for the variables to be monitored (design criteria section 6.0)

No identification of specific Type A monitored variables is provided in this standard. Recommendations for Type 3 and Type C monitored vari-ables are provided in Section 6.0.

i

The significant issues in the development of this standard have been:

1. the scope of the document in terms of applicability to the control room operator or the plant operator (licensee). The work group chose a control room operator scope.
2. the pre-planned operator actions designated by the accident analyses in Chapter 15 of a plant's FSAR and the not previously planned operator action that may be required during unforeseen events. The Working Group established Type A instrumentation for the former, and Type B or C instrumentation for the latter.
3. The monitoring of actual fission product barrier integrity and the potential for breach of a given barrier. The work group chose monitoring of actual breach for the fuel, reactor coolant system, and containment barrier, but only the potential breach of the con-tainment barrier.
4. the degree of alignment of accident monitoring instrumentation with IEEE Class .E(ANS Class EC-3) and whether an intermediate class is needed between 1E and non-1E.
5. whether a list of variables should be included as an appendix to the standard:
a. a list of only Type C parameters
b. a list of Type A, 3, C and 0 parameters
6. the definition of instrument types 3 and 0 and whether these types should be included in the standard.

The membership of the Working Group is as follows:

L. Stanley, Chairman T. Timmons, Vice Chairman and Correspondent ii

0. Scmmers E. Wenzinger
0. Lambert R. Bauerle J. Castanes M. Wolpert H. Mumford X. Polanski E. Oowling Additional input has been provided to the Working Group by industry, university, and government participants throughout the meetings. The Work Group is very appreciative of this assistance.

A iii

1.0 introduction The Code of Federal Regulations requires that instrumentation be provided to monitor variables and systems over their anticipated ranges for acci-dent conditions as appropriate to assure adequate safety. The purpose of this standard is to establish criteria for the selection of that instru-mentation. These criteria are based on the sequence and duration of the phases through which an accident progresses. The control room operator may have different information requirements for each phase of an accident.

This standard presents criteria for monitoring the response of the plant to design basis events. It also presents criteria for monitoring the integrity of fission product barriers under conditions which have degraded beyond the design bases. This fission product barrier monitoring is con-sidered to be an extra set of instrumentation beyond that required for satisfactorily monitoring accident scenarios postulated in the plant safety analysis.

Throughout these criteria, three verbs have been used to indicate the degree of rigor intended by the specific criterion. The word "shall" is used to denote a requirement; the word "should" to denote a recommenda-tion; and the word "may" to denote permission, neither a requirement nor a recommendation.

1

2.0 SCOPE This standard contains criteria for determining the variables to be moni-tored by the control room operator, as required for safety, during the course of an accident and during the long-term stable shutdown phase fol-lowing the accident. Also included are criteria for determining the requirements for the equipment used to monitor those variables.

The scope of the standard is limited to onsite environment and process monitoring. Emergency preparedness planning is, or 'will be, covered by other standards.

2

3.0 OEFINITIONS Phase I That portion of the accident extending from the initiation of the accident to that point at which the plant is in a con-trolled condition.

Phase II That portion of the accident extending from the time at which the plant is in a controlled condition to that point at which personnel access to the location of the accident is possible.

Phase III That portion of the accident extending from the time at which personnel access to the location of the accident is possible to the time at which the plant has returned to operating status or been decommissioned.

Type A Instruments - Those instruments which provide the information required to permit the control room operator to take the pre-planned manual actions to accomplish safe plant shutdown for design basis accident events and to maintain long term plant-stability.

Type B Those instruments which provide to the control room operator information to monitor the process of accomplishing critical safety functions, i.e., reactivity control, core cooling, maintaining reactor coolant system integrity, maintaining containment integrity and radioactive effluent control.

Type C Those instruments that indicate in the control room (1) the extent to which parameters, which have the potential for causing a breach of the final fission product barrier (i.e.,

the containment), have exceeded the design basis values, or (2) that a fission product barrier (i.e., fuel clad, reactor coolant pressure boundary or the containment) has been breached.

3

Type 0 Those instruments which indicate to the control room operator the performance of individual safety systems.

Design Basis Accident Events Those events postulated in the plant safety analyses, any one of which may occur during the lifetime of a particular plant, excluding those events which are expected to occur during a calendar year for a particular plant; and those events that are not expected to occur but are postulated in the plant safety analyses because their consequences would include the poten-tial for the release of significant amounts of radioactive material.

4

4.0 DISCUSSION It is the philosophy of this Standard that instrumentation is required to monitor plant performance during and after an accident. The purposes of the accident monitoring instrumentation are enumerated in Section 5.0, Design Basis. This Standard specifies the plant safety functions to be performed and the criteria to be used by the designer in selecting the variables to be monitored.

Certain concepts have been established to aid the system designer in the selection of variables to monitor the course of an accident and to arrive at appropriate design criteria for instruments to monitor these variables.

4.1 Planned Versus Unolanned Operator Actions The plant safety analysis defines the accident scenarios from which the safety system design bases and the planned or anticipated operator actions are derived. Accident monitoring instrumentation is provided to permit the operator to take required actions to address these analyzed.

situations. However, instrumentation must also be provided for unplanned situations, (i.e., to ensure that, should plant conditions evolve differently than predicted by the safety analysis, the operator has sufficient information to monitor the course of the event). Instru-mentation must also be provided to indicate to the operator if fission product barrier integrity has degraded beyond the prescribed limits of the Safety Analysis.

4.2 Variable Types Four classifications of variables have been identified. Operator manual actions during accidents included in the plant safety analysis are anticipated or pre-planned. Those variables that provide information needed by the operator to perform these manual actions are designated 5

Type A. Those variables needed to assess that the plant safety functions are being accomplished, as identified in the plant safety analysis, are designated Type S. Variables used to monitor for the actual gross breach of one of the fission product barriers or the potential breach of the final fission product barrier (containment) are designated Type C. Type C variables used to monitor the potential breach of containment have an arbitrarily-determined, extended range. The fourth classification, Type D, consists of those variables monitored to ascertain that the safety systems are performing as designed. Type 0 variables are less important than Types A, B and C for accident monitoring since safety system per-formance only infers safety function accomplishment. Type 0 variables and instruments are not considered to be within the scope of Accident Monitoring Instrumentation. Guidance on the selection of Type 0 vari-ables and the specification of appropriate design criteria are not given in this standard. This guidance is provided in standards for design of safety systems (e.g. IEEE-603, ANSI N1S.2, etc). The four classifica-tions are not mutually exclusive in that a given variable (or instrument) may be included in one or more types. This differentiation by variable type is intended only to guide the designer in his selection of accident monitoring variables and applicable criteria.

4.3 Accident Phases The typical accident sequence has been subdivided into three phases:

Phase I covers the initial portion of the accident, Phase II covers the stable long-term cooling portion of the accident up to the time where personnel access is possible, and Phase III addresses the period follow-ing personnel access to the accident area. This sub-division has been made so that variable selection and design criteria application can reflect the differing conditions which characterize these three phases.

For example, Phase I can be anticipated to be of relatively short dura-tion, having relatively severe plant conditions, and allowing no person-nel access to the accident area. Phase II is expected to be of longer duration, to require a significant number of operator actions, under milder plant conditions, but with still no personnel access to the acci-dent area. Phase III is expected to be of even longer duration where 6

personnel access is possible. Oifferent design criteria are then appro-priate for each of the three phases. In this Standard, guidance and criteria are provided for Phases i and Ii.

7

5.0 Oesign Basis The plant designer shall perform and document an analysis to select acci-dent monitoring instruments. He shall identify instruments required by his design to enable the control room operator to:

A. Perform pre-planned manual actions.

B. Ascertain the performance of:

(1) Reactivity control (2) Reactor core cooling (3) Reactor coolant system integrity (4) Containment integrity (5) Radioactive effluent control C. Ascertain the extent to which parameters, which have the potential for causing a breach of the containment, have exceeded the design basis values and to ascertain that a fission product barrier (i.e. fuel clad, reactor coolant system pressure boundary or the containment) has been breached.

5.1 Variable Selection for Phases I and II The process for selection of the Accident'Monitoring Instrumentation vari-ables shall include:

5.1.1 For Type A

1) Identification of the postulated accidents for which manual action is required.
2) Identification of planned operator actions
3) Identification of the monitored variables needed for planned operator actions.

a

5.1.2 For Type B

1) identification of the monitored variables that provide the most direct indication needed to assess the accomplish-ments of:
a. Reactivity Control
b. Reactor Core Cooling
c. Reactor Coolant System Integrity
d. Containment Integrity
e. Radioactive Effluent Control Guidance on the selection of these variables is provided in Section 6.0.

5.1.3 For Type C

1) Identification of the monitored variables that provide the most direct indication of a gross breach of a fission product barrier or of an approach to breach of the con-taimment. These instruments may have extended ranges.

Guidance on the selection of these variables is provided in Section 6.0.

5.1.4 Phase III Access Prior to the termination of Phase II, the ability to gain access to the location of the accident must be determined. Instrumentation that indicates when conditions are acceptable for personnel access shall be identified.

5.2 PERFORMANCE REQUIREMENTS FOR PHASES I ANO I:

The process for determining performance requirements of Accident Moni-toring Instrumentation shall include, as a minimum, the following con-siderations:

9

5.2.1 For Types A and 8

1) Identification of the expected range of the process variable.
2) Identification of the required accuracy of measurement.
3) Identification of the required response characteristics.
4) Identification of the time interval during which the measure-ment is needed.
5) Identification of the local environment in which the instru-ment must operate.

5.2.2 For Type C The performance requirements for these instruments are arbitrary.

Guidance on these requirements is provided in Section 6.0.

10

6.0 DESIGN CRITERIA 6.1 GENERAL DESIGN CRITERIA 6.1.1 SEISMIC QUALIFICATIONS Accident monitoring instrumentation that is to be seismically qualified shall be qualified according to IEEE Standard 344-1975. The instrumenta-tion shall be qualified to continue to function within the required accuracy following, but not necessarily during, a safe shutdown earth-quake. Vibration loads which occur as a result of plant system operation during any phase for which the instrument is required shall be considered.

6.1.2 DURATION Accident monitoring instrumentation shall be qualified for the length of time its function is required. Unless other times can be justified, Phase II instrumentation shall be qualified to function for not less than 100 days. A shorter time may be acceptable if instrumentation equipment replacement or repair can be accomplished within an acceotable out-of-service time, taking into consideration the environment where the equip-ment is located.

6.1.3 DIRECT MEASUREMENT To the extent practical, accident monitoring instrumentation inputs shall be from sensors that directly measure the desired variables.

6.1.4 MINIMIZING MEASUREMENTS To the extent practical, the same instruments shall be used for accident monitoring as are used for the normal operations of the plant to enable the operator to use, during an accident situation, instruments with which he is most familiar. However, where the required range of accident moni-toring instrumentation results in a loss of instrumentation sensitivity in the normal operating rance, separate instruments shall be used.

11

6.1.5 INSTALLATION Permanently installed instrument equipment is required for those instru-ments required to function during Phase I. Permanently installed instru-mentation systems need not be provided for those functions required only for Phases II and III providing it can be demonstrated that the instru-ment components can be installed when required, considering the local environment.

6.1.6 INSTRUMENTATION LOCATION AND IDENTIFICATION Accident monitoring instrumentation shall be located accessible to the operator and be distinguishable from other displays so that in an acci-dent situation, the operator can rapidly identify the accident monitoring instrumentation.

6.1.7 EQUIPMENT REPAIR, The accident monitoring instrumentation shall be designed to facilitate timely recognition, location, replacement, and repair or adjustment of malfunctioning equipment. -

6.1.8 TEST AND CALIBRATION 6.1.3.1 Test Capability shall be provided for testing, with a high degree of confi-dence, the operational availability of each instrument channel during plant operation. This may be accomplished in various ways, for example:

1. By observing the effect of perturbing the monitored variable.
2. By observing the effect of introducing and varying, as appropriate, a substitute inout to the sensor of the same nature as the measured variable.

12

3. By cross-checking between channels that bear a known relationship to.

each other.

Where testing during reactor operation is not possible, it must be shown that there is no practical way of implementing such a requirement without adversely affecting plant safety or operability. In addition, it must be shown that the probability of a failure of the component which is not periodically tested is acceptably low and that such testing can be rou-tinely performed when the reactor is shut down.

6.1.8.2 Calibration Capability shall be provided for calibration of each instrument channel during normal plant operation or during shutdown as determined by the required interval between calibrations. Equipment that does not require periodic calibration is exempt from this requirement.

5.1.9 DIVERSITY Diversity is preferred in fufilling redundancy requirements.

5.1.10 REDUNDANT READOUT AMBIGUITY Where a disagreement between redundant displays could lead the operator to defeat or fail to accomplish a required safety function, additional information shall be provided to allow the operator to deduce the actual conditions that are required for him to perform his role. This may be accomplished by providing an independent channel which monitors a dif-ferent variable bearing a known relationship to the redundant channel or by providing an additional independent channel of instrumentation of the same variable or by providing the capability for the operator to perturb the measured variable and determine by observation of the response which instrumentation display has failed.

13

  • 0 6.2 TYPE B INSTRUMENTS 6.2.1 GENERAL REQUIREMENTS -

The number of instruments used shall be only that minimum set needed to adequately monitor the accomplishment of the following functions:

a. Reactivity Control
b. Reactor Core Cooling
c. Reactor Coolant System Integrity
d. Containment Integrity
e. Radioactive Effluent Control Type 3 instruments provide control room indication beyond that which may be required for any preplanned operator action and as such constitute an extra set of instrumentation which results in an additional layer of protection.

6.2.2 VARIABLES FOR REACTIVITY CONTROL MONITORING The measured variable shall indicate the accomplishment of control of reactivity in the core. The measured variable should be neutron flux.

The range of measurement should extend from one count per second on the source range instrument to the intermediate range instrument value cor-responding to 1.5. of full reactor power. This range is intended to encompass all neutron flux levels at which the core can be subcritical.

6.2.3 VARIABLES FOR CORE COOLING MONITORING The measured variables shall indicate the accomplishment of core cool-ing. For the PWR, the measured variables should be TH, TC, pres-surizer level, and pressurizer pressure. For the BWR, the measured variable should be reactor vessel water level. Incore thermocouple monitoring should be considered for inclusion as a desireable variable to ascertain cooling.

14

6.2.4 VARIABLES FOR REACTOR COOLANT SYSTEM INTEGRITY The measured variable shall indicate the accomplishment of RCS inte-grity. The measured variable should be primary system pressure.

6.2.5 VARIABLES FOR CONTAINMENT INTEGRITY The measured variables shall indicate the accomplishment of containment integrity. The measured variables should be containment hydrogen con-centration, containment pressure and containment isolation valve posi-tions..

6.2.6 VARIABLES FOR RADIOACTIVE EFFLUENT CONTROL The measured variables shall indicate the accomplishment of radioactive effluent control. The measured variables should be noble gas monitoring of the identified plant release points.

6.3 TYPE C INSTRUMENTS 6.3.1 Type C instruments shall meet the following criteria:

5.3.1.1 The number of instruments used shall be only that minimum set needed to adequately monitor the three barriers; 6.3.1.2- Each measurement shall be as direct as possible; 6.3.1.3 Any chosen measurement shall detect a gross breach of one or more barriers (i.e., > 1 percent fuel clad failure, a RCS pressure boundary breach producing a loss of reactor coolant inventory in excess of the normal makeup capability, a con-tainment breach capable of producing radiation releases in excess of 10 CFR 100 at the site boundary using TID-14844 source terms); the ranges established for Type C instruments are not mechanistically related to a postulated accident scenario.

15

6.3.1.4 During the period of need for Type C instruments, no other failures shall be assumed in the analysis beyond the assumed breach of a barrier coincident with loss of off-site power; 0.3.2 Fuel Clad Barrier Monitoring 6.3.2.1 The measured variable shall detect and alarm the breach of the fuel clad barrier (i.e., > 1 percent fuel clad failure);

6.3.2.2 Operator sampling of reactor coolant shall be used as the means to verify the measured variable alarm.

6.3.2.3 The measured variable should be reactor coolant system radia-tion. The instrument range should be equivalent to the fuel clad gap activity corresponding to 0.5% to 5% failed fuel. A narrow accuracy band for this measured variable is not signi-ficant in achieving this function; for example, +50%, to +100%

accuracy of reading should be acceptable. instrument tran-sient response should be compatible with its recorder.

5.3.3 Reactor Coolant System Pressure Boundary Monitoring 6.3.3.1 The measured variable(s) shall detect and alarm a breach of the reactor coolant system that produces a loss of coolant inventory in excess of normal makeup capability. The spectrum of RCS pressure boundary breaches extends up to and includes the largest double-ended pipe break.

0.3.3.2 The means used to detect RCS pressure boundary breach should include one RCS pressure boundary variable and one containment variable over the full spectrum of break sizes.

6.3.3.3 The measured PWR variables should be RCS pressure and contain-ment pressure. The instrument range should be the design pressure plus a specified margin (< 1O%). Normal instrument accuracy is acceptable for these monitors. instrument tran-sient response should be compatible with its recorder.

16

6.3.3.4 The measured BWR variables should be drywell pressure and containment sump level. The instrument range should be design values plus a specified margin (< 10%). Normal instrument accuracy is acceptable for these monitors. Instrument tran-sient response should be compatible with its recorder.

6.3.4 Containment Pressure Boundary Monitoring 6.3.4.1 The measured variable(s) shall detect and alarm a breach of the containment pressure boundary that is capable of producing radiation releases in excess of 10 CFR 100 at the site boundary using TID-14844 source terms.

0.3.4.2 The means used to detect containment pressure boundary breach should include containment pressure (BWR and PWR), environs radiation monitoring for gross gamma (PWR), and secondary containment air space radiation monitoring for gross gamma (BWR).

6.3.4.3 The instrument range for containment pressure should be design pressure plus a specified margin (< 10%). Normal instrument accuracy is acceptable for this monitor. Instrument transient response should be compatible with its recorder.

6.3.4.4 The instrument range for environs radiation monitoring should be 10-3 to 102 R/hr. The instrument range for secondary containment air space radiation monitoring should correspond to the 10 CFR 100 value for off-site doses. Instrument accuracy should be + 1/2 decade (100 Kev-3 Mev). Instrument transient response should be compatible with its recorder.

6.3.5 Potential Breach of the Final Fission Product Barrier 6.3.5.1 The measured variables should be containment pressure, con-tainment hydrogen concentration, and RCS pressure for indicating the potential for causing a breach of the final fission product barrier (i.e., containment).

17

0 0 5.3.5.2 An arbitrary range of 3 times design pressure for concrete and 4 times design pressure for steel should be used for contain-ment pressure. Instrument accuracy should be + 10% of span.

Instrument transient response should be compatible with its recorder.

6.3.5.3 An arbitrary range of 0-10 volume percent hydrogen should be used for containment hydrogen concentration. Instrument accuracy should be + 10% of span. Instrument transient response should be compatiable with its recorder.

6.3.5.4 An arbitrary range of 1.5 times design pressure should be used for RCS pressure. Instrument accuracy should be + 10% of span. Instrument transient response should be compatible with its recorder.

6.3.6 INSTRUMENT QUALIFICATION 6.3.6.1 Type C instruments shall be qualified in the same manner as Type A instruments except:

6.3.5.1.1 For purposes of equipment qualification, the assumed maximum value of the monitored parameter shall be the value equal to the maximum range for the instrument. The monitored parameter shall be assumed to approach this peak by extrapolating the most severe initial ramp associated with the Design Basis Accidents. The decay for this parameter shall be considered proportional to the decay for this parameter associated with the Design Basis Accidents. No additional qualification margin needs to be added to the extended range parameter. See figure 6.3-1. All environmental envelopes except that per-taining to the parameter measured by the instrument shall be those associated with the Design Basis Accidents.

5.4 SPECIFIC DESIGN CRITERIA Design Criteria specific to particular accident phases and variable types are presented in Table 6.4-1.

18

TABLE 6.4.1 DESIGN CRITERIA PHASE 1 PHASE II VARIABLE TYPE VARIABLE TYPE CRITERION A B C A B C Yes Yes No No l.. Qualify seismically to IEEE 344-75 Yes No 0

(operate after SSE)

2. Meet single failure Yes Yes No Yes Yes No per IEEE 379-77
3. Qualify environmen- Yes Yes Yes(l) Yes Yes Yes U )

tally to IEEE 323-74

4. Consider loss of Yes Yes Yes Yes No No off-site power 0
5. Power source, Emergency Emerg. Emerg. Emerg. Normal(6) Normal (6).
6. Out of service interval (2) . (2) <72 fir(3) (2) (2) <72 fIrs 3)

- prior to accident

7. Otit of service inter- None None <2 hir (2) (2) <2 hIrs val - during accident

TABLE 6.4-1 (Continued)

DESIGLN CRITERIA P11ASE 1 PHASE I I VARIABLE TYPE VARIABLE TYPE CRITERION A B C A B C

8. Portable instrumenta- No No INo(7) Yes Yes Yes tiol
9. Level of quality ANSI N45.2 ANSI t445.2 ANSI N45.2 ANSI N45.2 ANSI N45.2 ANSI N45.2 assurance
10. Display type(4) Continuous Contifluou s Continuous Continuous Continuous On demand
11. Display method Recording(5) Recorddi ng Indicator Recording(5) Indicator Indicator
12. Identification as Yes Yes Yes Yes Yes Yes accident monitoring type
13. Periodic Test per Yes Yes Yes Yes Yes Yes IEEE-338-1977 NOTES: (1) See Paragraph 6.3.6 of this Standard.

(2) IEEE 279-1971 Paragraph 4.11 Exemuption

NOTES TO TABLE 6.4-1 (Continued) 3? Based on normal tech spec requirements on out-of-service safety systems.

4 Continuous indication or recording displays a given variable at all times; intermittent indication or recording displays a given variable periodically; on demand indication or recording displays a given variable only when requested.

(5) Where trend or transient information is essential to planned operator actions.

(6) May be manually connected to emergency buss (7) Radiation monitoring outside containment may be portable.

-4

4 Figure 6.3-1. Typical Environmental Qualification Envelope for Type C Instruments e- - - t I I Parameter I i k7 Assumied Parameter Environment I I I

I I

---3,rDesiqn Basis Accident 0

Timee.