ML072080045: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(2 intermediate revisions by the same user not shown)
Line 3: Line 3:
| issue date = 07/27/2007
| issue date = 07/27/2007
| title = NRC Generic Letter 2006-01: Steam Generator Tube Integrity and Associated Technical Specifications
| title = NRC Generic Letter 2006-01: Steam Generator Tube Integrity and Associated Technical Specifications
| author name = Mozafari B L
| author name = Mozafari B
| author affiliation = NRC/NRR/ADRO/DORL/LPLII-2
| author affiliation = NRC/NRR/ADRO/DORL/LPLII-2
| addressee name = Stall J A
| addressee name = Stall J
| addressee affiliation = Florida Power & Light Co
| addressee affiliation = Florida Power & Light Co
| docket = 05000389
| docket = 05000389
| license number = NPF-016
| license number = NPF-016
| contact person = Mozafari B L, NRR/ADRO/DORL, 415-2020
| contact person = Mozafari B, NRR/ADRO/DORL, 415-2020
| case reference number = GL-06-001, TAC MD0105
| case reference number = GL-06-001, TAC MD0105
| document type = Letter
| document type = Letter
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:July 27, 2007Mr. J. A. StallSenior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, FL 33408-0420
{{#Wiki_filter:July 27, 2007 Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, FL 33408-0420


==SUBJECT:==
==SUBJECT:==
ST. LUCIE, UNIT 2 - NRC GENERIC LETTER 2006-01: STEAMGENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NO. MD0105)
ST. LUCIE, UNIT 2 - NRC GENERIC LETTER 2006-01: STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NO. MD0105)


==Dear Mr. Stall:==
==Dear Mr. Stall:==


On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter(GL) 2006-01, "Steam Generator [SG] Tube Integrity and Associated Technical Specifications
On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2006-01, Steam Generator [SG] Tube Integrity and Associated Technical Specifications
[TSs]" (see Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity. By letter dated February 17, 2006, Florida Power and Light Company, the licensee for St. Lucie,Unit 2, submitted a response to GL 2006-01 (ADAMS Accession No. ML060530640). This response provided a regulatory commitment to submit a request to modify the SG portion of the TSs. By application to the NRC dated May 25, 2006, the licensee requested changes to the TSs for St. Lucie, Unit 2, to adopt the alternative TS requirements for ensuring SG tube integrity (ML061510346). The new TSs were modeled after Technical Specification Task Force (TSTF)
[TSs] (see Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity.
Traveler, TSTF-449, "Steam Generator Tube Integrity" (ML051090200). By letters dated January 22, 2007 (ML070250070) and April 16, 2007 (ML071210531), the licensee provided the NRC supplements to the original application. On May 29, 2007, the NRC staff issued Amendment No. 147 to the St. Lucie, Unit 2, Facility Operating License that approved the new SG TSs (ML071490483).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC No. MD0105. If you have any questions regarding this letter, please contact me at 301-415-2020.Sincerely, /RA/Brenda L. Mozafari, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-389 cc: See next page  
By letter dated February 17, 2006, Florida Power and Light Company, the licensee for St. Lucie, Unit 2, submitted a response to GL 2006-01 (ADAMS Accession No. ML060530640). This response provided a regulatory commitment to submit a request to modify the SG portion of the TSs. By application to the NRC dated May 25, 2006, the licensee requested changes to the TSs for St. Lucie, Unit 2, to adopt the alternative TS requirements for ensuring SG tube integrity (ML061510346). The new TSs were modeled after Technical Specification Task Force (TSTF)
Traveler, TSTF-449, Steam Generator Tube Integrity (ML051090200). By letters dated January 22, 2007 (ML070250070) and April 16, 2007 (ML071210531), the licensee provided the NRC supplements to the original application. On May 29, 2007, the NRC staff issued Amendment No. 147 to the St. Lucie, Unit 2, Facility Operating License that approved the new SG TSs (ML071490483).
The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC No. MD0105. If you have any questions regarding this letter, please contact me at 301-415-2020.
Sincerely,
                                                      /RA/
Brenda L. Mozafari, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-389 cc: See next page


ML060530640). This response provided a regulatory commitment to submit a request to modify the SG portion of the TSs. By application to the NRC dated May 25, 2006, the licensee requested changes to the TSs for St. Lucie, Unit 2, to adopt the alternative TS requirements for ensuring SG tube integrity (ML061510346). The new TSs were modeled after Technical Specification Task Force (TSTF)
ML060530640). This response provided a regulatory commitment to submit a request to modify the SG portion of the TSs. By application to the NRC dated May 25, 2006, the licensee requested changes to the TSs for St. Lucie, Unit 2, to adopt the alternative TS requirements for ensuring SG tube integrity (ML061510346). The new TSs were modeled after Technical Specification Task Force (TSTF)
Traveler, TSTF-449, "Steam Generator Tube Integrity" (ML051090200). By letters dated January 22, 2007 (ML070250070) and April 16, 2007 (ML071210531), the licensee provided the NRC supplements to the original application. On May 29, 2007, the NRC staff issued Amendment No. 147 to the St. Lucie, Unit 2, Facility Operating License that approved the new SG TSs (ML071490483).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC No. MD0105. If you have any questions regarding this letter, please contact me at 301-415-2020.Sincerely, /RA/Brenda L. Mozafari, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-389cc: See next page DISTRIBUTION
Traveler, TSTF-449, Steam Generator Tube Integrity (ML051090200). By letters dated January 22, 2007 (ML070250070) and April 16, 2007 (ML071210531), the licensee provided the NRC supplements to the original application. On May 29, 2007, the NRC staff issued Amendment No. 147 to the St. Lucie, Unit 2, Facility Operating License that approved the new SG TSs (ML071490483).
:PUBLICLPL2-2 R/FRidsNrrDorlLpl2-2RidsNrrPMBMozafariRidsNrrLABClayton (Hard Copy)RidsOgcRpRidsAcrsAcnwMailCenterRidsNrrDciCsgbRidsRgn2MailCenterRidsNrrDorlDprADAMS ACCESSION NO: ML072080045OFFICELPL2-2/PMLPL2-2/LANRR/CSGB/BCLPL2-2/BCNAMEBMozafariBClaytonAHiserTBoyce/LRaghavan forDATE 07/27/200707/27/200707/27/200707/27/2007 Florida Power and Light CompanyST. LUCIE PLANT cc:Mr. William E. Webster Vice President, Nuclear Operations, South Region Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Senior Resident Inspector   St. Lucie Plant U.S. Nuclear Regulatory Commission P.O. Box 6090 Jensen Beach, Florida 34957 Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 M. S. Ross, Managing Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420
The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC No. MD0105. If you have any questions regarding this letter, please contact me at 301-415-2020.
 
Sincerely,
Marjan Mashhadi, Senior Attorney Florida Power & Light Company 801 Pennsylvania Avenue, NW.
                                                              /RA/
Suite 220 Washington, DC 20004Mr. Douglas Anderson               County Administrator St. Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982    
Brenda L. Mozafari, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-389 cc: See next page DISTRIBUTION:
 
PUBLIC                        LPL2-2 R/F          RidsNrrDorlLpl2-2          RidsNrrPMBMozafari RidsNrrLABClayton (Hard Copy) RidsOgcRp          RidsAcrsAcnwMailCenter    RidsNrrDciCsgb RidsRgn2MailCenter            RidsNrrDorlDpr ADAMS ACCESSION NO: ML072080045 OFFICE LPL2-2/PM                LPL2-2/LA              NRR/CSGB/BC          LPL2-2/BC NAME BMozafari                  BClayton              AHiser              TBoyce/
Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741Mr. Gordon L. Johnston Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida  34957-2000Mr. Christopher R. CostanzoPlant General Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957Mr. Terry PattersonLicensing Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida  34957Don E. GrissetteVice President, Nuclear Training and Performance Improvement Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420Mr. Rajiv S. KundalkarVice President - Nuclear Technical Services Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420Mr. J. KammelRadiological Emergency Planning Administrator Department of Public Safety 6000 Southeast Tower Drive Stuart, Florida 34997Mr. Bill ParksOperations Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000Mr. Seth B. DustonTraining Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida  34957-2000}}
LRaghavan for DATE      07/27/2007            07/27/2007            07/27/2007          07/27/2007 Florida Power and Light Company    ST. LUCIE PLANT cc:
Mr. William E. Webster             Mr. Christopher R. Costanzo Vice President, Nuclear Operations, Plant General Manager South Region                       St. Lucie Nuclear Plant Florida Power & Light Company       6351 South Ocean Drive P.O. Box 14000                     Jensen Beach, Florida 34957 Juno Beach, FL 33408-0420 Mr. Terry Patterson Senior Resident Inspector           Licensing Manager St. Lucie Plant                    St. Lucie Nuclear Plant U.S. Nuclear Regulatory Commission 6351 South Ocean Drive P.O. Box 6090                       Jensen Beach, Florida 34957 Jensen Beach, Florida 34957 Don E. Grissette Craig Fugate, Director             Vice President, Nuclear Training Division of Emergency Preparedness and Performance Improvement Department of Community Affairs     Florida Power & Light Company 2740 Centerview Drive               P.O. Box 14000 Tallahassee, Florida 32399-2100     Juno Beach, FL 33408-0420 M. S. Ross, Managing Attorney       Mr. Rajiv S. Kundalkar Florida Power & Light Company      Vice President - Nuclear Technical Services P.O. Box 14000                      Florida Power & Light Company Juno Beach, FL 33408-0420          P.O. Box 14000 Juno Beach, FL 33408-0420 Marjan Mashhadi, Senior Attorney Florida Power & Light Company       Mr. J. Kammel 801 Pennsylvania Avenue, NW.       Radiological Emergency Suite 220                               Planning Administrator Washington, DC 20004                Department of Public Safety 6000 Southeast Tower Drive Mr. Douglas Anderson               Stuart, Florida 34997 County Administrator St. Lucie County                   Mr. Bill Parks 2300 Virginia Avenue               Operations Manager Fort Pierce, Florida 34982         St. Lucie Nuclear Plant 6351 South Ocean Drive Mr. William A. Passetti, Chief     Jensen Beach, Florida 34957-2000 Department of Health Bureau of Radiation Control         Mr. Seth B. Duston 2020 Capital Circle, SE, Bin #C21   Training Manager Tallahassee, Florida 32399-1741    St. Lucie Nuclear Plant 6351 South Ocean Drive Mr. Gordon L. Johnston              Jensen Beach, Florida 34957-2000 Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000}}

Latest revision as of 12:26, 13 March 2020

NRC Generic Letter 2006-01: Steam Generator Tube Integrity and Associated Technical Specifications
ML072080045
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 07/27/2007
From: Mozafari B
NRC/NRR/ADRO/DORL/LPLII-2
To: Stall J
Florida Power & Light Co
Mozafari B, NRR/ADRO/DORL, 415-2020
References
GL-06-001, TAC MD0105
Download: ML072080045 (4)


Text

July 27, 2007 Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, FL 33408-0420

SUBJECT:

ST. LUCIE, UNIT 2 - NRC GENERIC LETTER 2006-01: STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NO. MD0105)

Dear Mr. Stall:

On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2006-01, Steam Generator [SG] Tube Integrity and Associated Technical Specifications

[TSs] (see Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity.

By letter dated February 17, 2006, Florida Power and Light Company, the licensee for St. Lucie, Unit 2, submitted a response to GL 2006-01 (ADAMS Accession No. ML060530640). This response provided a regulatory commitment to submit a request to modify the SG portion of the TSs. By application to the NRC dated May 25, 2006, the licensee requested changes to the TSs for St. Lucie, Unit 2, to adopt the alternative TS requirements for ensuring SG tube integrity (ML061510346). The new TSs were modeled after Technical Specification Task Force (TSTF)

Traveler, TSTF-449, Steam Generator Tube Integrity (ML051090200). By letters dated January 22, 2007 (ML070250070) and April 16, 2007 (ML071210531), the licensee provided the NRC supplements to the original application. On May 29, 2007, the NRC staff issued Amendment No. 147 to the St. Lucie, Unit 2, Facility Operating License that approved the new SG TSs (ML071490483).

The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC No. MD0105. If you have any questions regarding this letter, please contact me at 301-415-2020.

Sincerely,

/RA/

Brenda L. Mozafari, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-389 cc: See next page

ML060530640). This response provided a regulatory commitment to submit a request to modify the SG portion of the TSs. By application to the NRC dated May 25, 2006, the licensee requested changes to the TSs for St. Lucie, Unit 2, to adopt the alternative TS requirements for ensuring SG tube integrity (ML061510346). The new TSs were modeled after Technical Specification Task Force (TSTF)

Traveler, TSTF-449, Steam Generator Tube Integrity (ML051090200). By letters dated January 22, 2007 (ML070250070) and April 16, 2007 (ML071210531), the licensee provided the NRC supplements to the original application. On May 29, 2007, the NRC staff issued Amendment No. 147 to the St. Lucie, Unit 2, Facility Operating License that approved the new SG TSs (ML071490483).

The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC No. MD0105. If you have any questions regarding this letter, please contact me at 301-415-2020.

Sincerely,

/RA/

Brenda L. Mozafari, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-389 cc: See next page DISTRIBUTION:

PUBLIC LPL2-2 R/F RidsNrrDorlLpl2-2 RidsNrrPMBMozafari RidsNrrLABClayton (Hard Copy) RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrDciCsgb RidsRgn2MailCenter RidsNrrDorlDpr ADAMS ACCESSION NO: ML072080045 OFFICE LPL2-2/PM LPL2-2/LA NRR/CSGB/BC LPL2-2/BC NAME BMozafari BClayton AHiser TBoyce/

LRaghavan for DATE 07/27/2007 07/27/2007 07/27/2007 07/27/2007 Florida Power and Light Company ST. LUCIE PLANT cc:

Mr. William E. Webster Mr. Christopher R. Costanzo Vice President, Nuclear Operations, Plant General Manager South Region St. Lucie Nuclear Plant Florida Power & Light Company 6351 South Ocean Drive P.O. Box 14000 Jensen Beach, Florida 34957 Juno Beach, FL 33408-0420 Mr. Terry Patterson Senior Resident Inspector Licensing Manager St. Lucie Plant St. Lucie Nuclear Plant U.S. Nuclear Regulatory Commission 6351 South Ocean Drive P.O. Box 6090 Jensen Beach, Florida 34957 Jensen Beach, Florida 34957 Don E. Grissette Craig Fugate, Director Vice President, Nuclear Training Division of Emergency Preparedness and Performance Improvement Department of Community Affairs Florida Power & Light Company 2740 Centerview Drive P.O. Box 14000 Tallahassee, Florida 32399-2100 Juno Beach, FL 33408-0420 M. S. Ross, Managing Attorney Mr. Rajiv S. Kundalkar Florida Power & Light Company Vice President - Nuclear Technical Services P.O. Box 14000 Florida Power & Light Company Juno Beach, FL 33408-0420 P.O. Box 14000 Juno Beach, FL 33408-0420 Marjan Mashhadi, Senior Attorney Florida Power & Light Company Mr. J. Kammel 801 Pennsylvania Avenue, NW. Radiological Emergency Suite 220 Planning Administrator Washington, DC 20004 Department of Public Safety 6000 Southeast Tower Drive Mr. Douglas Anderson Stuart, Florida 34997 County Administrator St. Lucie County Mr. Bill Parks 2300 Virginia Avenue Operations Manager Fort Pierce, Florida 34982 St. Lucie Nuclear Plant 6351 South Ocean Drive Mr. William A. Passetti, Chief Jensen Beach, Florida 34957-2000 Department of Health Bureau of Radiation Control Mr. Seth B. Duston 2020 Capital Circle, SE, Bin #C21 Training Manager Tallahassee, Florida 32399-1741 St. Lucie Nuclear Plant 6351 South Ocean Drive Mr. Gordon L. Johnston Jensen Beach, Florida 34957-2000 Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000