ML18040B084: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
| issue date = 03/06/2018 | | issue date = 03/06/2018 | ||
| title = Attachment - Vogtle Electric Generating Plant Unit 4 Amendment 111 (LAR-17-036) | | title = Attachment - Vogtle Electric Generating Plant Unit 4 Amendment 111 (LAR-17-036) | ||
| author name = Patel C | | author name = Patel C | ||
| author affiliation = NRC/NRO/DNRL/LB4 | | author affiliation = NRC/NRO/DNRL/LB4 | ||
| addressee name = Whitley B | | addressee name = Whitley B | ||
| addressee affiliation = Southern Nuclear Operating Co, Inc | | addressee affiliation = Southern Nuclear Operating Co, Inc | ||
| docket = 05200025, 05200026 | | docket = 05200025, 05200026 | ||
Line 15: | Line 15: | ||
| page count = 10 | | page count = 10 | ||
| project = EPID:L-2017-LLA-0104 | | project = EPID:L-2017-LLA-0104 | ||
| stage = | | stage = Acceptance Review | ||
}} | }} | ||
=Text= | =Text= | ||
{{#Wiki_filter:ATTACHMENT TO LICENSE AMENDMENT NO. 111 | {{#Wiki_filter:ATTACHMENT TO LICENSE AMENDMENT NO. 111 TO FACILITY COMBINED LICENSE NO. NPF-92 DOCKET NO. 52-026 Replace the following pages of the Facility Combined License No. NPF-92 with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change. | ||
C- | Facility Combined License No. NPF-92 REMOVE INSERT 7 7 Appendix C to Facility Combined License No. NPF-92 REMOVE INSERT C-431a C-431a | ||
--- C-431b C-432 C-432 | |||
--- C-432a C-433 C-433 | |||
--- C-433a C-434 C-434 | |||
--- C-434a | |||
}} | |||
(7) Reporting Requirements (a) Within 30 days of a change to the initial test program described in FSAR Section 14, Initial Test Program, made in accordance with 10 CFR 50.59 or in accordance with 10 CFR Part 52, Appendix D, Section VIII, Processes for Changes and Departures, SNC shall report the change to the Director of NRO, or the Directors designee, in accordance with 10 CFR 50.59(d). | |||
(b) SNC shall report any violation of a requirement in Section 2.D.(3), | |||
Section 2.D.(4), Section 2.D.(5), and Section 2.D.(6) of this license within [[estimated NRC review hours::24 hours]]. Initial notification shall be made to the NRC Operations Center in accordance with 10 CFR 50.72, with written follow up in accordance with 10 CFR 50.73. | |||
(8) Incorporation The Technical Specifications, Environmental Protection Plan, and ITAAC in Appendices A, B, and C, respectively of this license, as revised through Amendment No. 111, are hereby incorporated into this license. | |||
(9) Technical Specifications The technical specifications in Appendix A to this license become effective upon a Commission finding that the acceptance criteria in this license (ITAAC) are met in accordance with 10 CFR 52.103(g). | |||
(10) Operational Program Implementation SNC shall implement the programs or portions of programs identified below, on or before the date SNC achieves the following milestones: | |||
(a) Environmental Qualification Program implemented before initial fuel load; (b) Reactor Vessel Material Surveillance Program implemented before initial criticality; (c) Preservice Testing Program implemented before initial fuel load; (d) Containment Leakage Rate Testing Program implemented before initial fuel load; (e) Fire Protection Program | |||
: 1. The fire protection measures in accordance with Regulatory Guide (RG) 1.189 for designated storage building areas (including adjacent fire areas that could affect the storage area) implemented before initial receipt 7 Amendment No. 111 | |||
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 799 3.3.00.07d.i 7.d) Physical separation is maintained Inspections of the as-built Results of the inspection will between Class 1E divisions and raceways that route Class 1E confirm that the separation between Class 1E divisions and non- cables will be performed to between raceways that route Class 1E cables. confirm that the separation Class 1E cables of different between raceways that route divisions, and between Class 1E cables of different raceways that route Class 1E divisions, and between raceways cables and raceways that route that route Class 1E cables and non-Class 1E cables is raceways that route non-Class consistent with the following: | |||
1E cables is consistent with the following: | |||
i) Within the main control i) Within the main control room and remote shutdown room and remote shutdown room (non-hazard areas), the room (non-hazard areas) the minimum separation for minimum separation for low-voltage power cables and low-voltage power cables below is defined by one of the and below meets one of the following: following: | |||
: 1) For configurations 1) For configurations involving open configurations involving open to enclosed configurations configurations to enclosed with low-voltage power configurations with low-cables, the minimum vertical voltage power cables, the separation is 3 inches and the vertical separation is minimum horizontal 3 inches or more and the separation is 1 inch. horizontal separation is 1 inch or more. | |||
: 2) For configurations 2) For configurations that involving an enclosed raceway involve an enclosed raceway and an open raceway with and an open raceway with low-voltage power cables, the low-voltage power cables, minimum vertical separation is the minimum vertical 1 inch if the enclosed raceway separation may be reduced is below the open raceway. to 1 inch if the enclosed raceway is below the open raceway. | |||
: 3) For configurations involving 3) For configurations that enclosed raceways, the involve enclosed raceways, minimum separation is 1 inch in the minimum separation is both horizontal and vertical 1 inch in both horizontal and directions. vertical directions. | |||
C-431a Amendment No. 111 | |||
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria | |||
: 4) For configurations 4) For configurations that involving open configurations, involve open configurations, and an enclosed raceway and and an enclosed raceway an open raceway, with and an open raceway, with instrumentation and control instrumentation and control cables, the minimum cables, the minimum separation is 1 inch in both separation is 1 inch in both horizontal and vertical horizontal and vertical directions. directions. | |||
C-431b Amendment No. 111 | |||
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 800 3.3.00.07d.ii.a 7.d) Physical separation is maintained Inspections of the as-built Results of the inspection will between Class 1E divisions and raceways that route Class 1E confirm that the separation between Class 1E divisions and non- cables will be performed to between raceways that route Class 1E cables. confirm that the separation Class 1E cables of different between raceways that route divisions, and between Class 1E cables of different raceways that route Class 1E divisions, and between raceways cables and raceways that route that route Class 1E cables and non-Class 1E cables is raceways that route non-Class consistent with the following: | |||
1E cables is consistent with the following: | |||
ii.a) Within other plant areas ii.a) Within other plant areas (hazard areas), the minimum inside containment (hazard separation is defined by one of areas), the separation meets the following: one of the following: | |||
: 1) The minimum vertical 1) The vertical separation is separation is 5 feet and the 5 feet or more and the minimum horizontal separation horizontal separation is 3 feet is 3 feet. or more. | |||
: 2) The minimum vertical 2) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches for raceways separation is 6 inches for containing only instrumentation raceways containing only and control and low-voltage instrumentation and control power cables 2/0 AWG. This and low-voltage power cables minimum vertical separation is 2/0 AWG. This minimum 3 inches for the configuration vertical separation may be with a conduit above and reduced to 3 inches for the crossing the open tray at an configuration with a conduit angle equal to or greater than above and crossing the open 45 degrees. tray at an angle equal to or greater than 45 degrees. | |||
: 3) The minimum vertical 3) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches between a conduit separation is 6 inches between and an open configuration for a conduit and an open low- voltage power cables configuration for low- voltage greater than 2/0 AWG but not power cables greater than greater than 750 kcmil. The 2/0 AWG but not greater than vertical separation is 3 inches if 750 kcmil. The vertical a conduit is above and crossing separation may be reduced to an open tray at an angle equal to 3 inches if a conduit is above or greater than 45 degrees. and crossing an open tray at an angle equal to or greater than 45 degrees. | |||
C-432 Amendment No. 111 | |||
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria | |||
: 4) For configurations that 4) For configurations that involve exclusively limited involve exclusively limited energy content cables energy content cables (instrumentation and control), (instrumentation and control), | |||
the minimum vertical separation the minimum vertical is 1 inch and the minimum separation is 1 inch and the horizontal separation is 1 inch. minimum horizontal separation is 1 inch. | |||
: 5) For configurations involving 5) For configurations that an enclosed raceway and an involve an enclosed raceway open raceway with low-voltage and an open raceway with power cables, the minimum low-voltage power cables, the vertical separation is 1 inch if minimum vertical separation the enclosed raceway is below is 1 inch if the enclosed the open raceway. raceway is below the open raceway. | |||
: 6) For configuration involving 6) For configurations that enclosed raceways, the involve enclosed raceways, minimum separation is 1 inch in the minimum vertical and both horizontal and vertical horizontal separation is 1 inch. | |||
directions. | |||
: 7) The minimum vertical 7) The minimum vertical separation is 1 inch and the separation is 1 inch and the minimum horizontal separation minimum horizontal is 1 inch for configurations with separation is 1 inch for a non-safety conduit and a free configurations with a non-air safety cable with low-voltage safety conduit and a free air power cables and below. safety cable with low-voltage power cables and below. | |||
C-432a Amendment No. 111 | |||
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 801 3.3.00.07d.ii.b 7.d) Physical separation is maintained Inspections of the as-built Results of the inspection will between Class 1E divisions and raceways that route Class 1E confirm that the separation between Class 1E divisions and non- cables will be performed to between raceways that route Class 1E cables. confirm that the separation Class 1E cables of different between raceways that route divisions, and between Class 1E cables of different raceways that route Class 1E divisions, and between raceways cables and raceways that route that route Class 1E cables and non-Class 1E cables is raceways that route non-Class consistent with the following: | |||
1E cables is consistent with the following: | |||
ii.b) Within other plant areas ii.b) Within other plant areas (limited hazard areas), the inside the non-radiologically minimum separation is defined controlled area of the auxiliary by one of the following: building (limited hazard areas), the separation meets one of the following: | |||
: 1) The minimum vertical 1) The vertical separation is separation is 5 feet and the 5 feet or more and the minimum horizontal separation horizontal separation is 3 feet is 3 feet. or more. | |||
: 2) The minimum vertical 2) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches for raceways separation is 6 inches for containing only instrumentation raceways containing only and control and low-voltage instrumentation and control power cables 2/0 AWG. This and low-voltage power cables minimum vertical separation is 2/0 AWG. This minimum 3 inches for the configuration vertical separation may be with a conduit above and reduced to 3 inches for the crossing the open tray at an configuration with a conduit angle equal to or greater than 45 above and crossing the open degrees. tray at an angle equal to or greater than 45 degrees. | |||
C-433 Amendment No. 111 | |||
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria | |||
: 3) The minimum vertical 3) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches between a conduit separation is 6 inches between and an open configuration for a conduit and an open low- voltage power cables configuration for low- voltage greater than 2/0 AWG but not power cables greater than greater than 750 kcmil. The 2/0 AWG but not greater than vertical separation is 3 inches if 750 kcmil. The vertical a conduit is above and crossing separation may be reduced to an open tray at an angle equal to 3 inches if a conduit is above or greater than 45 degrees. and crossing an open tray at an angle equal to or greater than 45 degrees. | |||
: 4) For configurations that 4) For configurations that involve exclusively limited involve exclusively limited energy content cables energy content cables (instrumentation and control), (instrumentation and control), | |||
the minimum vertical separation the minimum vertical is 1 inch and the minimum separation is 1 inch and the horizontal separation is 1 inch. minimum horizontal separation is 1 inch. | |||
: 5) For configurations involving 5) For configurations that an enclosed raceway and an involve an enclosed raceway open raceway with low-voltage and an open raceway with power cables, the minimum low-voltage power cables, the vertical separation is 1 inch if minimum vertical separation the enclosed raceway is below is 1 inch if the enclosed the open raceway. raceway is below the open raceway. | |||
: 6) For configuration involving 6) For configurations that enclosed raceways, the involve enclosed raceways, minimum separation is 1 inch in the minimum vertical and both horizontal and vertical horizontal separation is 1 inch directions. | |||
: 7) The minimum vertical 7) The minimum vertical separation is 1 inch and the separation is 1 inch and the minimum horizontal separation minimum horizontal is 1 inch for configurations with separation is 1 inch for a non-safety conduit and a free configurations with a non-air safety cable with low-voltage safety conduit and a free air power cables and below. safety cable with low-voltage power cables and below. | |||
C-433a Amendment No. 111 | |||
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 802 3.3.00.07d.ii.c 7.d) Physical separation is maintained Inspections of the as-built Results of the inspection will between Class 1E divisions and raceways that route Class 1E confirm that the separation between Class 1E divisions and non- cables will be performed to between raceways that route Class 1E cables. confirm that the separation Class 1E cables of different between raceways that route divisions, and between Class 1E cables of different raceways that route Class 1E divisions, and between raceways cables and raceways that route that route Class 1E cables and non-Class 1E cables is raceways that route non-Class consistent with the following: | |||
1E cables is consistent with the following: | |||
ii.c) Within other plant areas ii.c) Within other plant areas (limited hazard areas), the inside the radiologically minimum separation is defined controlled area of the auxiliary by one of the following: building (limited hazard areas), the separation meets one of the following: | |||
: 1) The minimum vertical 1) The vertical separation is separation is 5 feet and the 5 feet or more and the minimum horizontal separation horizontal separation is 3 feet is 3 feet. or more. | |||
: 2) The minimum vertical 2) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches for raceways separation is 6 inches for containing only instrumentation raceways containing only and control and low-voltage instrumentation and control power cables 2/0 AWG. This and low-voltage power cables minimum vertical separation is 2/0 AWG. This minimum 3 inches for the configuration vertical separation may be with a conduit above and reduced to 3 inches for the crossing the open tray at an configuration with a conduit angle equal to or greater than 45 above and crossing the open degrees. tray at an angle equal to or greater than 45 degrees. | |||
C-434 Amendment No. 111 | |||
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria | |||
: 3) The minimum vertical 3) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches between a conduit separation is 6 inches between and an open configuration for a conduit and an open low- voltage power cables configuration for low- voltage greater than 2/0 AWG but not power cables greater than greater than 750 kcmil. The 2/0 AWG but not greater than vertical separation is 3 inches if 750 kcmil. The vertical a conduit is above and crossing separation may be reduced to an open tray at an angle equal to 3 inches if a conduit is above or greater than 45 degrees. and crossing an open tray at an angle equal to or greater than 45 degrees. | |||
: 4) For configurations that 4) For configurations that involve exclusively limited involve exclusively limited energy content cables energy content cables (instrumentation and control), (instrumentation and control), | |||
the minimum vertical separation the minimum vertical is 1 inch and the minimum separation is 1 inch and the horizontal separation is 1 inch. minimum horizontal separation is 1 inch. | |||
: 5) For configurations involving 5) For configurations that an enclosed raceway and an involve an enclosed raceway open raceway with low-voltage and an open raceway with power cables, the minimum low-voltage power cables, the vertical separation is 1 inch if minimum vertical separation the enclosed raceway is below is 1 inch if the enclosed the open raceway. raceway is below the open raceway. | |||
: 6) For configuration involving 6) For configurations that enclosed raceways, the involve enclosed raceways, minimum separation is 1 inch in the minimum vertical and both horizontal and vertical horizontal separation is 1 inch. | |||
directions. | |||
: 7) The minimum vertical 7) The minimum vertical separation is 1 inch and the separation is 1 inch and the minimum horizontal separation minimum horizontal is 1 inch for configurations with separation is 1 inch for a non-safety conduit and a free configurations with a non-air safety cable with low-voltage safety conduit and a free air power cables and below. safety cable with low-voltage power cables and below. | |||
C-434a Amendment No. 111}} |
Latest revision as of 20:25, 7 March 2020
ML18040B084 | |
Person / Time | |
---|---|
Site: | Vogtle |
Issue date: | 03/06/2018 |
From: | Chandu Patel NRC/NRO/DNRL/LB4 |
To: | Whitley B Southern Nuclear Operating Co |
patel c/415-3025 | |
Shared Package | |
ML18040B074 | List: |
References | |
EPID L-2017-LLA-0104, LAR 17-036 | |
Download: ML18040B084 (10) | |
Text
ATTACHMENT TO LICENSE AMENDMENT NO. 111 TO FACILITY COMBINED LICENSE NO. NPF-92 DOCKET NO.52-026 Replace the following pages of the Facility Combined License No. NPF-92 with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.
Facility Combined License No. NPF-92 REMOVE INSERT 7 7 Appendix C to Facility Combined License No. NPF-92 REMOVE INSERT C-431a C-431a
--- C-431b C-432 C-432
--- C-432a C-433 C-433
--- C-433a C-434 C-434
--- C-434a
(7) Reporting Requirements (a) Within 30 days of a change to the initial test program described in FSAR Section 14, Initial Test Program, made in accordance with 10 CFR 50.59 or in accordance with 10 CFR Part 52, Appendix D, Section VIII, Processes for Changes and Departures, SNC shall report the change to the Director of NRO, or the Directors designee, in accordance with 10 CFR 50.59(d).
(b) SNC shall report any violation of a requirement in Section 2.D.(3),
Section 2.D.(4), Section 2.D.(5), and Section 2.D.(6) of this license within 24 hours1 days <br />0.143 weeks <br />0.0329 months <br />. Initial notification shall be made to the NRC Operations Center in accordance with 10 CFR 50.72, with written follow up in accordance with 10 CFR 50.73.
(8) Incorporation The Technical Specifications, Environmental Protection Plan, and ITAAC in Appendices A, B, and C, respectively of this license, as revised through Amendment No. 111, are hereby incorporated into this license.
(9) Technical Specifications The technical specifications in Appendix A to this license become effective upon a Commission finding that the acceptance criteria in this license (ITAAC) are met in accordance with 10 CFR 52.103(g).
(10) Operational Program Implementation SNC shall implement the programs or portions of programs identified below, on or before the date SNC achieves the following milestones:
(a) Environmental Qualification Program implemented before initial fuel load; (b) Reactor Vessel Material Surveillance Program implemented before initial criticality; (c) Preservice Testing Program implemented before initial fuel load; (d) Containment Leakage Rate Testing Program implemented before initial fuel load; (e) Fire Protection Program
- 1. The fire protection measures in accordance with Regulatory Guide (RG) 1.189 for designated storage building areas (including adjacent fire areas that could affect the storage area) implemented before initial receipt 7 Amendment No. 111
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 799 3.3.00.07d.i 7.d) Physical separation is maintained Inspections of the as-built Results of the inspection will between Class 1E divisions and raceways that route Class 1E confirm that the separation between Class 1E divisions and non- cables will be performed to between raceways that route Class 1E cables. confirm that the separation Class 1E cables of different between raceways that route divisions, and between Class 1E cables of different raceways that route Class 1E divisions, and between raceways cables and raceways that route that route Class 1E cables and non-Class 1E cables is raceways that route non-Class consistent with the following:
1E cables is consistent with the following:
i) Within the main control i) Within the main control room and remote shutdown room and remote shutdown room (non-hazard areas), the room (non-hazard areas) the minimum separation for minimum separation for low-voltage power cables and low-voltage power cables below is defined by one of the and below meets one of the following: following:
- 1) For configurations 1) For configurations involving open configurations involving open to enclosed configurations configurations to enclosed with low-voltage power configurations with low-cables, the minimum vertical voltage power cables, the separation is 3 inches and the vertical separation is minimum horizontal 3 inches or more and the separation is 1 inch. horizontal separation is 1 inch or more.
- 2) For configurations 2) For configurations that involving an enclosed raceway involve an enclosed raceway and an open raceway with and an open raceway with low-voltage power cables, the low-voltage power cables, minimum vertical separation is the minimum vertical 1 inch if the enclosed raceway separation may be reduced is below the open raceway. to 1 inch if the enclosed raceway is below the open raceway.
- 3) For configurations involving 3) For configurations that enclosed raceways, the involve enclosed raceways, minimum separation is 1 inch in the minimum separation is both horizontal and vertical 1 inch in both horizontal and directions. vertical directions.
C-431a Amendment No. 111
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria
- 4) For configurations 4) For configurations that involving open configurations, involve open configurations, and an enclosed raceway and and an enclosed raceway an open raceway, with and an open raceway, with instrumentation and control instrumentation and control cables, the minimum cables, the minimum separation is 1 inch in both separation is 1 inch in both horizontal and vertical horizontal and vertical directions. directions.
C-431b Amendment No. 111
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 800 3.3.00.07d.ii.a 7.d) Physical separation is maintained Inspections of the as-built Results of the inspection will between Class 1E divisions and raceways that route Class 1E confirm that the separation between Class 1E divisions and non- cables will be performed to between raceways that route Class 1E cables. confirm that the separation Class 1E cables of different between raceways that route divisions, and between Class 1E cables of different raceways that route Class 1E divisions, and between raceways cables and raceways that route that route Class 1E cables and non-Class 1E cables is raceways that route non-Class consistent with the following:
1E cables is consistent with the following:
ii.a) Within other plant areas ii.a) Within other plant areas (hazard areas), the minimum inside containment (hazard separation is defined by one of areas), the separation meets the following: one of the following:
- 1) The minimum vertical 1) The vertical separation is separation is 5 feet and the 5 feet or more and the minimum horizontal separation horizontal separation is 3 feet is 3 feet. or more.
- 2) The minimum vertical 2) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches for raceways separation is 6 inches for containing only instrumentation raceways containing only and control and low-voltage instrumentation and control power cables 2/0 AWG. This and low-voltage power cables minimum vertical separation is 2/0 AWG. This minimum 3 inches for the configuration vertical separation may be with a conduit above and reduced to 3 inches for the crossing the open tray at an configuration with a conduit angle equal to or greater than above and crossing the open 45 degrees. tray at an angle equal to or greater than 45 degrees.
- 3) The minimum vertical 3) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches between a conduit separation is 6 inches between and an open configuration for a conduit and an open low- voltage power cables configuration for low- voltage greater than 2/0 AWG but not power cables greater than greater than 750 kcmil. The 2/0 AWG but not greater than vertical separation is 3 inches if 750 kcmil. The vertical a conduit is above and crossing separation may be reduced to an open tray at an angle equal to 3 inches if a conduit is above or greater than 45 degrees. and crossing an open tray at an angle equal to or greater than 45 degrees.
C-432 Amendment No. 111
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria
- 4) For configurations that 4) For configurations that involve exclusively limited involve exclusively limited energy content cables energy content cables (instrumentation and control), (instrumentation and control),
the minimum vertical separation the minimum vertical is 1 inch and the minimum separation is 1 inch and the horizontal separation is 1 inch. minimum horizontal separation is 1 inch.
- 5) For configurations involving 5) For configurations that an enclosed raceway and an involve an enclosed raceway open raceway with low-voltage and an open raceway with power cables, the minimum low-voltage power cables, the vertical separation is 1 inch if minimum vertical separation the enclosed raceway is below is 1 inch if the enclosed the open raceway. raceway is below the open raceway.
- 6) For configuration involving 6) For configurations that enclosed raceways, the involve enclosed raceways, minimum separation is 1 inch in the minimum vertical and both horizontal and vertical horizontal separation is 1 inch.
directions.
- 7) The minimum vertical 7) The minimum vertical separation is 1 inch and the separation is 1 inch and the minimum horizontal separation minimum horizontal is 1 inch for configurations with separation is 1 inch for a non-safety conduit and a free configurations with a non-air safety cable with low-voltage safety conduit and a free air power cables and below. safety cable with low-voltage power cables and below.
C-432a Amendment No. 111
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 801 3.3.00.07d.ii.b 7.d) Physical separation is maintained Inspections of the as-built Results of the inspection will between Class 1E divisions and raceways that route Class 1E confirm that the separation between Class 1E divisions and non- cables will be performed to between raceways that route Class 1E cables. confirm that the separation Class 1E cables of different between raceways that route divisions, and between Class 1E cables of different raceways that route Class 1E divisions, and between raceways cables and raceways that route that route Class 1E cables and non-Class 1E cables is raceways that route non-Class consistent with the following:
1E cables is consistent with the following:
ii.b) Within other plant areas ii.b) Within other plant areas (limited hazard areas), the inside the non-radiologically minimum separation is defined controlled area of the auxiliary by one of the following: building (limited hazard areas), the separation meets one of the following:
- 1) The minimum vertical 1) The vertical separation is separation is 5 feet and the 5 feet or more and the minimum horizontal separation horizontal separation is 3 feet is 3 feet. or more.
- 2) The minimum vertical 2) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches for raceways separation is 6 inches for containing only instrumentation raceways containing only and control and low-voltage instrumentation and control power cables 2/0 AWG. This and low-voltage power cables minimum vertical separation is 2/0 AWG. This minimum 3 inches for the configuration vertical separation may be with a conduit above and reduced to 3 inches for the crossing the open tray at an configuration with a conduit angle equal to or greater than 45 above and crossing the open degrees. tray at an angle equal to or greater than 45 degrees.
C-433 Amendment No. 111
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria
- 3) The minimum vertical 3) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches between a conduit separation is 6 inches between and an open configuration for a conduit and an open low- voltage power cables configuration for low- voltage greater than 2/0 AWG but not power cables greater than greater than 750 kcmil. The 2/0 AWG but not greater than vertical separation is 3 inches if 750 kcmil. The vertical a conduit is above and crossing separation may be reduced to an open tray at an angle equal to 3 inches if a conduit is above or greater than 45 degrees. and crossing an open tray at an angle equal to or greater than 45 degrees.
- 4) For configurations that 4) For configurations that involve exclusively limited involve exclusively limited energy content cables energy content cables (instrumentation and control), (instrumentation and control),
the minimum vertical separation the minimum vertical is 1 inch and the minimum separation is 1 inch and the horizontal separation is 1 inch. minimum horizontal separation is 1 inch.
- 5) For configurations involving 5) For configurations that an enclosed raceway and an involve an enclosed raceway open raceway with low-voltage and an open raceway with power cables, the minimum low-voltage power cables, the vertical separation is 1 inch if minimum vertical separation the enclosed raceway is below is 1 inch if the enclosed the open raceway. raceway is below the open raceway.
- 6) For configuration involving 6) For configurations that enclosed raceways, the involve enclosed raceways, minimum separation is 1 inch in the minimum vertical and both horizontal and vertical horizontal separation is 1 inch directions.
- 7) The minimum vertical 7) The minimum vertical separation is 1 inch and the separation is 1 inch and the minimum horizontal separation minimum horizontal is 1 inch for configurations with separation is 1 inch for a non-safety conduit and a free configurations with a non-air safety cable with low-voltage safety conduit and a free air power cables and below. safety cable with low-voltage power cables and below.
C-433a Amendment No. 111
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria 802 3.3.00.07d.ii.c 7.d) Physical separation is maintained Inspections of the as-built Results of the inspection will between Class 1E divisions and raceways that route Class 1E confirm that the separation between Class 1E divisions and non- cables will be performed to between raceways that route Class 1E cables. confirm that the separation Class 1E cables of different between raceways that route divisions, and between Class 1E cables of different raceways that route Class 1E divisions, and between raceways cables and raceways that route that route Class 1E cables and non-Class 1E cables is raceways that route non-Class consistent with the following:
1E cables is consistent with the following:
ii.c) Within other plant areas ii.c) Within other plant areas (limited hazard areas), the inside the radiologically minimum separation is defined controlled area of the auxiliary by one of the following: building (limited hazard areas), the separation meets one of the following:
- 1) The minimum vertical 1) The vertical separation is separation is 5 feet and the 5 feet or more and the minimum horizontal separation horizontal separation is 3 feet is 3 feet. or more.
- 2) The minimum vertical 2) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches for raceways separation is 6 inches for containing only instrumentation raceways containing only and control and low-voltage instrumentation and control power cables 2/0 AWG. This and low-voltage power cables minimum vertical separation is 2/0 AWG. This minimum 3 inches for the configuration vertical separation may be with a conduit above and reduced to 3 inches for the crossing the open tray at an configuration with a conduit angle equal to or greater than 45 above and crossing the open degrees. tray at an angle equal to or greater than 45 degrees.
C-434 Amendment No. 111
Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No. ITAAC No. Design Commitment Inspections, Tests, Analyses Acceptance Criteria
- 3) The minimum vertical 3) The minimum vertical separation is 12 inches and the separation is 12 inches and the minimum horizontal separation minimum horizontal is 6 inches between a conduit separation is 6 inches between and an open configuration for a conduit and an open low- voltage power cables configuration for low- voltage greater than 2/0 AWG but not power cables greater than greater than 750 kcmil. The 2/0 AWG but not greater than vertical separation is 3 inches if 750 kcmil. The vertical a conduit is above and crossing separation may be reduced to an open tray at an angle equal to 3 inches if a conduit is above or greater than 45 degrees. and crossing an open tray at an angle equal to or greater than 45 degrees.
- 4) For configurations that 4) For configurations that involve exclusively limited involve exclusively limited energy content cables energy content cables (instrumentation and control), (instrumentation and control),
the minimum vertical separation the minimum vertical is 1 inch and the minimum separation is 1 inch and the horizontal separation is 1 inch. minimum horizontal separation is 1 inch.
- 5) For configurations involving 5) For configurations that an enclosed raceway and an involve an enclosed raceway open raceway with low-voltage and an open raceway with power cables, the minimum low-voltage power cables, the vertical separation is 1 inch if minimum vertical separation the enclosed raceway is below is 1 inch if the enclosed the open raceway. raceway is below the open raceway.
- 6) For configuration involving 6) For configurations that enclosed raceways, the involve enclosed raceways, minimum separation is 1 inch in the minimum vertical and both horizontal and vertical horizontal separation is 1 inch.
directions.
- 7) The minimum vertical 7) The minimum vertical separation is 1 inch and the separation is 1 inch and the minimum horizontal separation minimum horizontal is 1 inch for configurations with separation is 1 inch for a non-safety conduit and a free configurations with a non-air safety cable with low-voltage safety conduit and a free air power cables and below. safety cable with low-voltage power cables and below.
C-434a Amendment No. 111