ML15258A404: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
| issue date = 08/27/2015
| issue date = 08/27/2015
| title = Shine Medical Technologies V. 0 - Chapter 07 - Figures 7a2.1-001 Through 7a2.6-002
| title = Shine Medical Technologies V. 0 - Chapter 07 - Figures 7a2.1-001 Through 7a2.6-002
| author name = Bynum R V
| author name = Bynum R
| author affiliation = Shine Medical Technologies, Inc
| author affiliation = Shine Medical Technologies, Inc
| addressee name =  
| addressee name =  
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:Chapter 7 - Instrument & Control Systems Summary Description SHINE Medical Technologies  Rev. 0 Figure 7a2.1 Safety Approach for TSV Shutdown Neutron Flux Detection System TSV Reactivity Protection System(TRPS)Operator Interface DisplaysPower SourceDedicated NO Trip BreakerDedicated NO Trip Breaker A ATarget Solution Vessel(TSV)B BTarget Solution Dump Tank A BTarget SolutionIrradiatedTarget SolutionIU CellBoundaryNeutron Driver(NDAS)TSVInlet Isolation Valves TSVDump ValvesDump Tank Outlet Isolation ValvesWiringDistribution EnclosureControl RoomNeutronFlux Detector x3TSV Process Control System (TPCS)
{{#Wiki_filter:Chapter 7 - Instrument & Control Systems                                                                 Summary Description Figure 7a2.1 Safety Approach for TSV Shutdown Power Source Dedicated NOTrip Breaker Dedicated NOTrip Breaker Neutron Driver (NDAS)
Chapter 7 - Instrument & Control Systems Design of Instrument and Control Systems SHINE Medical Technologies Rev. 0  Figure 7a2.2 I&C System Block Diagram for Irradiation Facility Annunciator Display TSV Reactivity Protection System TRPS Engineered Safety Features Actuaton System (ESFAS A)TSV Process Control System TPCSAnnunciator Display Detail Drill Down Display Event Log AnnuciatorDisplay Detail Drill Down Display Event Log Annunciator Display SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #1 IU Cell #1 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #2 IU Cell #2 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #3 IU Cell #3 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #4 IU Cell #4 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #5 IU Cell #5 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #6 IU Cell #6 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #7 IU Cell #7 SubCritical Assembly System SCAS Neutron Driver Assembly System NDAS Neutron Flux Detection System NFDS #8 IU Cell #8 Safety RelatedProcessControl NonSafety Engineered Safety Features Actuaton System (ESFAS B)Isolated Links Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System SHINE Medical Technologies Rev. 0  Figure 7a2.5 Typical ESF Circuit K1 K2 L1Coil OutputESF A N TPCS ESD PBA1A2 C1 IN 1 SENSE 1 SENSE 2RESET Other Relays in IU Cell Group Relay Monitor Relay OutputRESET PB K1 K2A1A2 SENSE 1 SENSE 2RESET Relay Monitor Relay Output IN 2 ESF A Relay 1 ESF A Relay 2(L+)(O REF)Detector BOUT 2 Detector A OUT 1Other Detectors Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System SHINE Medical Technologies Rev. 0 Figure 7a2.5 Example ESFAS Panel 12" Above Floor0.0 in.3.6 in.6.0 in.12.0 in.16in.29in.42in.3in.IU Cell #1IU Cell #2IU Cell #3IU Cell #4IU Cell #5IU Cell #6IU Cell #7IU Cell #8 1 3 5 7 9 2 4 6 8 10 12 11 1 2 3 4 5 6BubbleTight Inlet Damper Relays 7 8 9 10 11BubbleTight Outlet Damper RelaysPCLS Inlet Isolation Valve RelaysLWPS Inlet Isolation Valve RelaysLWPS Outlet Isolation Valve Relays 12SparePCLS Outlet Isolation Valve RelaysTritium Delivery Isolation Valve RelaysTritium Return Isolation Valve Relays TRPS Input Signal Trip RelaysSpareSpare Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System SHINE Medical Technologies Rev. 0  Figure 7a2.5 ESFAS Manual Operator Panel
Wiring Distribution Enclosure Neutron Flux Detector x3 Target Solution Vessel (TSV)
IU Cell Boundary Target Solution TSV A        B             Dump Valves TSV Inlet Isolation A        B Valves Target Solution Dump Tank A
Dump Tank Outlet Isolation Valves B
Irradiated Target Solution TSV Reactivity                                                                     TSV Process Neutron Flux Protection System                                                                 Control System Detection System (TRPS)                                                                           (TPCS)
Control Room Operator Interface Displays SHINE Medical Technologies                                                                                           Rev. 0


IU Cell #4ESD  AESD  BRESET  ARESET  BTRPPED  ATRPPED  BOVERRIDE AOVERRIDE BBULBCHECKIU Cell #3ESD  AESD  BRESET  ARESET  BTRPPED  ATRPPED  BOVERRIDE AOVERRIDE B BULBCHECKIU Cell #2ESD  AESD  BRESET  ARESET  BTRPPED  ATRPPED  BOVERRIDE AOVERRIDE B BULBCHECKIU Cell #1ESD  AESD  BRESET  ARESET  BTRPPED  ATRPPED  BOVERRIDE AOVERRIDE B BULBCHECKIU Cell #5ESD  AESD  BRESET  ARESET  BTRPPED  ATRPPED  BOVERRIDE AOVERRIDE B BULBCHECKIU Cell #6ESD  AESD  BRESET  ARESET  BTRPPED  ATRPPED  BOVERRIDE AOVERRIDE BBULBCHECKIU Cell #7ESD  AESD  BRESET  ARESET  BTRPPED  ATRPPED  BOVERRIDE AOVERRIDE B BULBCHECKIU Cell #8ESD  AESD  BRESET  ARESET  BTRPPED  ATRPPED  BOVERRIDE AOVERRIDE BBULBCHECK33" AboveGround0.0 in.3.6 in.6.0 in.12.0 in.Tripped IlluminationOverride IlluminationESD Pushbutton Reset PushbuttonCheck Pushbutton19in.27in.39in.7in.4' by 5' Panel Chapter 7 - Instrument & Control Systems Control Console and Display Information SHINE Medical Technologies Rev. 0 Figure 7a2.6 Irradiation Facility Workstation Layout
Chapter 7 - Instrument & Control Systems                                                                                                                                          Design of Instrument and Control Systems Figure 7a2.2 I&C System Block Diagram for Irradiation Facility NonSafety Process Control                                                                    Event Log                                                                          Event Log Annunciator          Detail DrillDown                                            Annunciator          Detail DrillDown Annuciator                                                                        Annunciator Safety                  Display                  Display                                                    Display                Display Related Display                                                                          Display Engineered Safety                  TSV Reactivity                                                                TSV Process Control                    Engineered Safety Features Actuaton                Protection System                            Isolated Links                            System                          Features Actuaton System (ESFASA)                        TRPS                                                                                TPCS                          System (ESFASB)
Neutron Flux          Neutron Flux          Neutron Flux          Neutron Flux            Neutron Flux        Neutron Flux            Neutron Flux            Neutron Flux Detection            Detection            Detection              Detection                Detection          Detection              Detection                Detection System                System                System                System                  System              System                  System                  System NFDS #1              NFDS #2              NFDS #3                NFDS #4                  NFDS #5            NFDS #6                NFDS #7                  NFDS #8 Neutron Driver        Neutron Driver      Neutron Driver          Neutron Driver          Neutron Driver      Neutron Driver          Neutron Driver          Neutron Driver Assembly              Assembly              Assembly              Assembly                Assembly            Assembly                Assembly                Assembly System                System                System                System                  System              System                  System                  System NDAS                  NDAS                  NDAS                  NDAS                    NDAS                NDAS                    NDAS                    NDAS SubCritical          SubCritical          SubCritical          SubCritical            SubCritical        SubCritical            SubCritical            SubCritical Assembly              Assembly              Assembly              Assembly                Assembly            Assembly                Assembly                Assembly System                System                System                System                  System              System                  System                  System SCAS                  SCAS                  SCAS                  SCAS                    SCAS                SCAS                    SCAS                    SCAS IU Cell #1            IU Cell #2            IU Cell #3            IU Cell #4              IU Cell #5          IU Cell #6              IU Cell #7              IU Cell #8 SHINE Medical Technologies                                                                                                                                                                                           Rev. 0


KeyboardKeyboard Keyboard TRPS Fixed Status Display TPCS Fixed Status Display TRPS Alarm/ Event Display TPCS Alarm/ Event Display TRPS HMI Display TPCS HMI Display RICS Status Display RICS Alarm Display RICS HMI Display Chapter 7 - Instrument & Control Systems Control Console and Display Information SHINE Medical Technologies Rev. 0 Figure 7a2.6 Control Room Layout
Chapter 7 - Instrument & Control Systems                                                   Engineered Safety Features Actuation System Figure 7a2.5 Typical ESF Circuit (L+)                                                                                                                              (O REF)
L1                                                                                                                                  N ESD PB    TPCS        Detector A    Detector B A1 ESF A A2                A1 ESF A A2 OUT 1                                Relay 1                    Relay 2 SENSE 1                    SENSE 1 RESET                        RESET SENSE 2                    SENSE 2 OUT 2 Other          Relay                      Relay Detectors        Output                      Output C1 Coil Output ESF A Relay                      Relay IN 1 Monitor                    Monitor K1        K2              K1        K2 IN 2 RESET PB Other Relays in IU Cell Group SHINE Medical Technologies                                                                                                       Rev. 0


Security-Related Information - Withhold under 10 CFR 2.390}}
Chapter 7 - Instrument & Control Systems            Engineered Safety Features Actuation System Figure 7a2.5 Example ESFAS Panel IU Cell #1                      IU Cell #2 1
2 3
4 5
6 7
8 9
10 11 12 IU Cell #3                      IU Cell #4 IU Cell #5                      IU Cell #6 42in.
IU Cell #7                      IU Cell #8                                        29in.
16in.
3in.
12" Above Floor 1 BubbleTight Inlet Damper Relays        7  Tritium Delivery Isolation Valve Relays 2 BubbleTight Outlet Damper Relays      8  Tritium Return Isolation Valve Relays 3 PCLS Inlet Isolation Valve Relays      9  TRPS Input Signal Trip Relays 4 PCLS Outlet Isolation Valve Relays      10 Spare 5 LWPS Inlet Isolation Valve Relays      11 Spare 0.0 in. 3.6 in. 6.0 in.          12.0 in.
6 LWPS Outlet Isolation Valve Relays      12 Spare SHINE Medical Technologies                                                                                  Rev. 0
 
Chapter 7 - Instrument & Control Systems                                                                            Engineered Safety Features Actuation System Figure 7a2.5 ESFAS Manual Operator Panel IU Cell #1                      IU Cell #2                      IU Cell #3                            IU Cell #4 Override Illumination OVERRIDE              OVERRIDE  OVERRIDE              OVERRIDE  OVERRIDE              OVERRIDE        OVERRIDE                  OVERRIDE A                    B          A                    B          A                    B              A                          B Tripped Illumination TRPPED  A            TRPPED  B TRPPED  A            TRPPED  B TRPPED  A            TRPPED  B      TRPPED  A                TRPPED  B ESD Pushbutton ESD  A              ESD  B    ESD  A              ESD  B    ESD  A              ESD  B        ESD  A                    ESD  B Reset Pushbutton RESET  A            RESET  B  RESET  A            RESET  B  RESET  A            RESET  B      RESET  A                  RESET  B Check Pushbutton BULB                            BULB                            BULB                                  BULB CHECK                            CHECK                            CHECK                                  CHECK IU Cell #5                      IU Cell #6                      IU Cell #7                            IU Cell #8 39in.
OVERRIDE              OVERRIDE  OVERRIDE              OVERRIDE  OVERRIDE              OVERRIDE        OVERRIDE                  OVERRIDE A                    B          A                    B          A                    B              A                          B TRPPED  A            TRPPED  B TRPPED  A            TRPPED  B TRPPED  A            TRPPED  B      TRPPED  A                TRPPED  B 4' by 5' Panel          ESD  A              ESD  B    ESD  A              ESD  B    ESD  A              ESD  B        ESD  A                    ESD  B 27in.
RESET  A            RESET  B  RESET  A            RESET  B  RESET  A            RESET  B      RESET  A                  RESET  B 19in.
BULB                            BULB                            BULB                                  BULB CHECK                            CHECK                            CHECK                                  CHECK 7in.
33" Above Ground 0.0 in. 3.6 in. 6.0 in.            12.0 in.
SHINE Medical Technologies                                                                                                                                                      Rev. 0
 
Chapter 7 - Instrument & Control Systems                                                        Control Console and Display Information Figure 7a2.6 Irradiation Facility Workstation Layout TRPS Fixed Status                  TPCS Fixed Status                      RICS Status Display                            Display                          Display TRPS Alarm/ Event                TPCS Alarm/ Event                      RICS Alarm Display                            Display                          Display TRPS HMI                          TPCS HMI                          RICS HMI Display                            Display                          Display Keyboard                            Keyboard                          Keyboard SHINE Medical Technologies                                                                                                      Rev. 0
 
Chapter 7 - Instrument & Control Systems              Control Console and Display Information Figure 7a2.6 Control Room Layout Security-Related Information - Withhold under 10 CFR 2.390 SHINE Medical Technologies                                                              Rev. 0}}

Latest revision as of 06:41, 31 October 2019

Shine Medical Technologies V. 0 - Chapter 07 - Figures 7a2.1-001 Through 7a2.6-002
ML15258A404
Person / Time
Site: SHINE Medical Technologies
Issue date: 08/27/2015
From: Bynum R
Shine Medical Technologies
To:
Office of Nuclear Reactor Regulation
Lynch S
References
SHINE, SHINE.SUBMISSION.22, SHN.PSAR.P, SHN.PSAR.P.10
Download: ML15258A404 (7)


Text

Chapter 7 - Instrument & Control Systems Summary Description Figure 7a2.1 Safety Approach for TSV Shutdown Power Source Dedicated NOTrip Breaker Dedicated NOTrip Breaker Neutron Driver (NDAS)

Wiring Distribution Enclosure Neutron Flux Detector x3 Target Solution Vessel (TSV)

IU Cell Boundary Target Solution TSV A B Dump Valves TSV Inlet Isolation A B Valves Target Solution Dump Tank A

Dump Tank Outlet Isolation Valves B

Irradiated Target Solution TSV Reactivity TSV Process Neutron Flux Protection System Control System Detection System (TRPS) (TPCS)

Control Room Operator Interface Displays SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Design of Instrument and Control Systems Figure 7a2.2 I&C System Block Diagram for Irradiation Facility NonSafety Process Control Event Log Event Log Annunciator Detail DrillDown Annunciator Detail DrillDown Annuciator Annunciator Safety Display Display Display Display Related Display Display Engineered Safety TSV Reactivity TSV Process Control Engineered Safety Features Actuaton Protection System Isolated Links System Features Actuaton System (ESFASA) TRPS TPCS System (ESFASB)

Neutron Flux Neutron Flux Neutron Flux Neutron Flux Neutron Flux Neutron Flux Neutron Flux Neutron Flux Detection Detection Detection Detection Detection Detection Detection Detection System System System System System System System System NFDS #1 NFDS #2 NFDS #3 NFDS #4 NFDS #5 NFDS #6 NFDS #7 NFDS #8 Neutron Driver Neutron Driver Neutron Driver Neutron Driver Neutron Driver Neutron Driver Neutron Driver Neutron Driver Assembly Assembly Assembly Assembly Assembly Assembly Assembly Assembly System System System System System System System System NDAS NDAS NDAS NDAS NDAS NDAS NDAS NDAS SubCritical SubCritical SubCritical SubCritical SubCritical SubCritical SubCritical SubCritical Assembly Assembly Assembly Assembly Assembly Assembly Assembly Assembly System System System System System System System System SCAS SCAS SCAS SCAS SCAS SCAS SCAS SCAS IU Cell #1 IU Cell #2 IU Cell #3 IU Cell #4 IU Cell #5 IU Cell #6 IU Cell #7 IU Cell #8 SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System Figure 7a2.5 Typical ESF Circuit (L+) (O REF)

L1 N ESD PB TPCS Detector A Detector B A1 ESF A A2 A1 ESF A A2 OUT 1 Relay 1 Relay 2 SENSE 1 SENSE 1 RESET RESET SENSE 2 SENSE 2 OUT 2 Other Relay Relay Detectors Output Output C1 Coil Output ESF A Relay Relay IN 1 Monitor Monitor K1 K2 K1 K2 IN 2 RESET PB Other Relays in IU Cell Group SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System Figure 7a2.5 Example ESFAS Panel IU Cell #1 IU Cell #2 1

2 3

4 5

6 7

8 9

10 11 12 IU Cell #3 IU Cell #4 IU Cell #5 IU Cell #6 42in.

IU Cell #7 IU Cell #8 29in.

16in.

3in.

12" Above Floor 1 BubbleTight Inlet Damper Relays 7 Tritium Delivery Isolation Valve Relays 2 BubbleTight Outlet Damper Relays 8 Tritium Return Isolation Valve Relays 3 PCLS Inlet Isolation Valve Relays 9 TRPS Input Signal Trip Relays 4 PCLS Outlet Isolation Valve Relays 10 Spare 5 LWPS Inlet Isolation Valve Relays 11 Spare 0.0 in. 3.6 in. 6.0 in. 12.0 in.

6 LWPS Outlet Isolation Valve Relays 12 Spare SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System Figure 7a2.5 ESFAS Manual Operator Panel IU Cell #1 IU Cell #2 IU Cell #3 IU Cell #4 Override Illumination OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE A B A B A B A B Tripped Illumination TRPPED A TRPPED B TRPPED A TRPPED B TRPPED A TRPPED B TRPPED A TRPPED B ESD Pushbutton ESD A ESD B ESD A ESD B ESD A ESD B ESD A ESD B Reset Pushbutton RESET A RESET B RESET A RESET B RESET A RESET B RESET A RESET B Check Pushbutton BULB BULB BULB BULB CHECK CHECK CHECK CHECK IU Cell #5 IU Cell #6 IU Cell #7 IU Cell #8 39in.

OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE A B A B A B A B TRPPED A TRPPED B TRPPED A TRPPED B TRPPED A TRPPED B TRPPED A TRPPED B 4' by 5' Panel ESD A ESD B ESD A ESD B ESD A ESD B ESD A ESD B 27in.

RESET A RESET B RESET A RESET B RESET A RESET B RESET A RESET B 19in.

BULB BULB BULB BULB CHECK CHECK CHECK CHECK 7in.

33" Above Ground 0.0 in. 3.6 in. 6.0 in. 12.0 in.

SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Control Console and Display Information Figure 7a2.6 Irradiation Facility Workstation Layout TRPS Fixed Status TPCS Fixed Status RICS Status Display Display Display TRPS Alarm/ Event TPCS Alarm/ Event RICS Alarm Display Display Display TRPS HMI TPCS HMI RICS HMI Display Display Display Keyboard Keyboard Keyboard SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Control Console and Display Information Figure 7a2.6 Control Room Layout Security-Related Information - Withhold under 10 CFR 2.390 SHINE Medical Technologies Rev. 0