TAC:59005
From kanterella
(Redirected from TAC:59006)
Jump to navigation
Jump to search
Request for: Approved, Closed | |
| |
| From | |
MONTHYEARML20087M6171984-03-28028 March 1984
[table view]Forwards Proprietary & Nonproprietary Versions of, Methodology for Addressing Superheated Steam Releases to Ice Condenser Containments. Proprietary Version Withheld (Ref 10CFR2.790) ML20092D9801984-06-15015 June 1984 Informs That Westinghouse Determined Main Steam Line Break in Doghouses Can Cause Steam Generator Tubes to Uncover, Allowing Superheated Steam to Form,Generating Higher Steam Line Exit Temps.Equipment Qualification Based on 330 F ML20090C4421984-07-11011 July 1984 Advises That Confirmatory Item 12, Main Steam Line Break, Reviewed W/Respect to Pending Request to Load Fuel & Perform Precritical Testing.Consequences Less Severe than FSAR Section 15.1.5 Analysis ML20094M9801984-08-0808 August 1984 Forwards Summary Evaluation of Main Steam Line Break Analysis for Both Inside Containment & in Doghouse.Plant Safety Would Not Be Adversely Affected in Event of Design Basis Main Line Break in Doghouse or Inside Containment ML20127L7191985-05-31031 May 1985 Evaluation of Main Steam Line Break in Doghouse ML20127L6971985-06-21021 June 1985 Forwards Evaluation of Main Steam Line Break in Doghouse. Higher Temps Generated in Event of Main Steam Line Break in Doghouse Will Not Affect Capability to Shut Down Main Reactor & Maintain Safe Condition ML20135H8551985-09-16016 September 1985 Forwards Request for Addl Info on 850621 Submittal Re Main Steam Line Break in Doghouse.Response Requested within 60 Days of Ltr Date ML20137C0161985-11-15015 November 1985 Forwards Responses to 850916 Request for Addl Info Re Main Steam Line Break in Doghouse.Heat Transfer Rate Maintained in Excess of Value Calculated W/Combination of Tube Bundle Uncovery & Superheated Steam Heat Transfer ML20206M5621986-08-13013 August 1986 SER Accepting 840808 & 850621 Responses to IE Info Notice 84-90, Main Steam Line Break Effect on Environ Qualification of Equipment. Higher Temp Will Not Preclude Ability to Shut Down Reactor in Safe Shutdown Condition ML20206M5571986-08-13013 August 1986 Forwards SER Accepting 840808 & 850621 Responses to IE Info Notice 84-90, Main Steam Line Break Effect on Environ Qualification of Equipment. Higher Temp Will Not Preclude Ability to Shut Down Reactor in Safe Shutdown Condition 1985-11-15 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:59005&oldid=5485139"