TAC:44632
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
Results Other: ML19210D033, ML19256G108, ML19260A004, ML19323A503, ML19338E845, ML19350C825, ML20004B900, ML20009F737, ML20039D573 | |
| From | |
MONTHYEARML19260A0041979-10-11011 October 1979
[table view]Advises of NRC Requirements for Auxiliary Feedwater Sys. Generic & plant-specific Requirements Encl ML19210D0331979-11-15015 November 1979 Forwards Response to Re NRC Requirements for Auxiliary Feedwater Sys.Refueling Shutdown Will Commence on 791201.Some Testing Recommendations Will Not Be Scheduled Until Startup Testing Performed ML19256G1081979-12-18018 December 1979 Notifies That Requested Info Re Auxiliary Feedwater Sys Automatic Initiations & Flow Indications to Steam Generators Was Provided During 791213 Site Visit ML19294B2131980-01-22022 January 1980 Forwards Request for Addl Info & Positions Re NRC Requirements for Auxiliary Feedwater Sys.Licensee Must Provide Info That Describes How Auxiliary Feedwater Automatic Initiation Sys Signals Meet Requirements ML19309A8821980-03-25025 March 1980 Forwards Response to NRC 800122 Request for Addl Info Re Requirements for Auxiliary Feedwater Sys.Complete Response Not Available Until Completion of Engineering Evaluation ML19323A5031980-04-14014 April 1980 Forwards Revised Tables 1B-1,2-1 & 3-1 to Util 800325 Response Re Auxiliary Feedwater Sys ML19323C5621980-05-14014 May 1980 Application for Amend 46 to Ol,Providing Proposed Tech Spec Changes.Revisions Include Addition of safety-related Hydraulic Snubbers to Table 3.7-4 & Mod of Surveillance Requirements for Auxiliary Feedwater Sys.Affidavit Encl ML19338E8451980-09-30030 September 1980 Forwards Addl Info on Auxiliary Feedwater Sys,In Response to NRC 800122 Request ML20037C8521981-02-0707 February 1981 Forwards Safety Evaluation of Licensee Implementations of NRC 791011 Recommendations for Auxiliary Feedwater Sys. Responses Satisfy NRC Requirements,W/Exception of Five Items ML19343C4351981-03-20020 March 1981 Application for Amend 59 to License DPR-66,changing App a Tech Specs to Ensure Redundancy of Auxiliary Feedwater Flow During Normal & Accident Conditions.Class III Fee Encl ML19350C8251981-03-27027 March 1981 Informs That Auxiliary Feedwater Sys Can Provide Required Flow for Feedline Rupture & for Main Steam Line Break Inside Containment W/O Operator Intervention for 10 Minutes ML20004B9001981-05-22022 May 1981 Forwards Rept, Auxiliary Feedwater Pumps Presently Installed at Beaver Valley Power Station,Unit 1 ML20009F7371981-07-21021 July 1981 Responds to 810715 Telcon Requesting Util Position Re Primary Plant Demineralized Water Storage Tank Level Transmitters.Both Transmitters Are Seismically Qualified & Powered from Vital Bus 2.No Need to Modify Power Supply ML20039D5731981-12-30030 December 1981 Provides Info Re NUREG-0737 Items Scheduled for Implementation on 820101.Mods Requiring Station Shutdown Will Be Completed During Second Refueling Outage Scheduled 821225 1980-05-14 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:44632&oldid=4806334"