- IR 05000382/2017008 (← links)
- ML15202A000 (← links)
- ML14316A207 (← links)
- ML13295A450 (← links)
- ML110060695 (← links)
- ML101740061 (← links)
- ML081070326 (← links)
- LIC-08-0037, Calculation FC05694, Calculation of Minimum Reactor Coolant Time Using Shutdown Cooling System, Attachment 2, Pages 51 Through 90 (← links)
- ML18025B725 (← links)
- ML18065A996 (← links)
- ML18065A919 (← links)
- ML18065A789 (← links)
- ML18065A612 (← links)
- ML051890474 (← links)
- ML20107M581 (← links)
- ML20137H598 (← links)
- ML20141F261 (← links)
- ML20217C310 (← links)
- ML20062H320 (← links)
- 05000333/LER-1989-005-01, :on 890412,HPCI Sys Made Inoperable to Find & Correct Grounded Electrical Circuit.Caused by Accumulation of Conductive Rust/Corrosion Products.Cleaning Provided Satisfactory Repair & Technical Manual Updated (← links)
- 05000366/LER-1988-022-02, :on 880902,during HPCI Testing,Turbine Tripped & Inboard Steam Supply Isolation Valve Closed.Caused by Magnetic Speed Pickup Cable (SPC) Physical Configuration.Spc Repaired & SPC Protection Mechanism Developed (← links)
- 05000317/LER-1998-006, :on 980325,1B DG Failed to Start During Performance of Routine Surveillance Test.Caused by Piece of Nylon in Governors Shutdown Solenoid Valve.Conducted Review (← links)
- 05000250/LER-1986-036, :on 861106,requirements of Tech Spec 3.7 Exceeded When Both Emergency Diesel Generators Declared Out of Svc.Caused by Governor Solenoid Out of Adjustment. Governor Solenoid Properly Adjusted (← links)
- 05000352/LER-1999-008, :on 990623,plant HPCI Failed to Start.Caused by Corrosion Products Which Caused Binding in Hydraulic Actuator.Hydraulic Actuator Was Replaced,Surveillance Test Was Performed & HPCI Was Declared Operable on 990625 (← links)
- 05000317/LER-1997-010, :on 971210,1B EDG Failed to Start During Performance of Routine Surveillance Test.Caused by Piece of Stainless Steel Foreign Matl in Governor Hydraulic Boundaries.Stainless Steel Replaced.With (← links)
- 05000370/LER-1997-002-03, :on 970711,reactor Tripped Due to RCP Motor Failure.Caused by Design/Manufacturing Deficiency Which Existed in Nc Pump Motor.Motor Stator 2D Was Replaced W/Rewound Spare (← links)
- 05000219/LER-1985-020, :on 851111,diesel Generator 1-2 Declared Inoperable When Reverse Power Relay Tripped During Surveillance Test.Caused by Electric Governor Actuator Controller Failure.Controller Replaced (← links)
- 05000327/LER-1997-002-01, :on 970214,TS AOT Exceeded for DG 2A-A.Caused by Mechanical Failure of DG 2A-A Governor Actuator on Engine 2.DG 2A-A Governor Actuators on Both Engines Replaced, Functional Tested & PMT Performed (← links)
- 05000336/LER-1991-009-01, :on 910821,DG Exhibited Erratic Load Control, Resulting in Erratic Load Swings on DG 12 U.Caused by Intermittent Failure of Woodward Governor EG-A Control Unit. Unit Replaced & Full Test Program Conducted (← links)
- 05000293/LER-1996-003, :on 960403,RCICS Made Inoperable Due to Anomalies Noted During Testing.Caused by Malfunctioning Speed Control Sys Hydraulic Actuator (EG-R).EG-R Replaced & Rcics Declared Operable on 960405 (← links)
- 05000336/LER-1991-009, :on 910821,both EDGs Declared Inoperable.Caused by Load Swings Due to Oxidation Buildup on Relay Contacts. Governor Controls Sys on 12U DG & 13U DG Updated W/New Electronic Governor Actuator Controls (← links)
- 05000321/LER-1994-013, :on 941103,false Low Turbine Speed Signal Resulted in Inoperable HPCI Sys.Caused by Failure or Misadjustment of Turbine Magnetic Speed Pickup.Magnetic Speed Pickup Replaced (← links)
- 05000293/LER-1993-013, :on 930530,RCIC Sys Declared Inoperable & 7 Day TS 3.5.D.2 LCO Entered Due to Speed Oscillations Which Occurred After Several Minutes of steady-state Operation. Caused by Actuator Failure.Actuator Replaced (← links)
- 05000423/LER-1994-011-02, :on 940908,manual Reactor Trip Initiated Due to MSIV Failure During part-stroke Test.Solenoid Valve & Number of Pins Replaced & MSIVs Tested Satisfactorily (← links)
- IR 05000423/1981004 (← links)
- ML20009H482 (← links)
- 05000333/LER-1989-019, :on 891031 & 891103,HPCI Sys Declared Inoperable Due to Electrical Ground in Speed Control Circuit.Caused by Buildup of Conductive Corrosion Products. Connector Cleaned & Sys Returned to Svc (← links)
- ML18155A284 (← links)
- ML18066A786 (← links)
- ML18065B036 (← links)
- ML18059B068 (← links)
- 05000348/LER-2015-005-01, Regarding Condition Prohibited by Technical Specifications Due to Turbine Driven Auxiliary Feedwater Design Issue (← links)
- 05000348/LER-2015-005, Regarding Condition Prohibited by Technical Specifications Due to Turbine Driven Auxiliary Feedwater Design Issue (← links)
- 05000334/LER-2014-002, Regarding Turbine Driven Auxiliary Feedwater Pump Governor Oscillations Result in Pump Trip (← links)
- 05000366/LER-2013-003, Regarding HPCI Declared Inoperable Due to Error in Connecting Tubing to a Hydraulic Actuator (← links)
- 05000260/LER-2009-008, Reactor Core Isolation Cooling System Inoperable Longer than Allowed by the Plants Technical Specifications (← links)
- 05000293/LER-2007-002, Emergency Diesel Generator Kilowatt (Kw) Power Oscillations (← links)
- 05000366/LER-2007-005, Regarding High Pressure Coolant Injection System Inoperabe Due to Water Intursion Into the Oil System (← links)
- 05000389/LER-2003-006, Regarding Long-Standing 2C TDAFW Pump Design Issue Resulted in Condition Prohibited by Technical Specifications (← links)
- 05000298/LER-1996-003, :on 960320,single Train RCIC Sys Inoperable Due to Equipment Malfunction.Specific Cause of Failure Could Not Be Determined.Malfunctioning EGM Control Box Was Replaced (← links)