Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20260D257 + (Reference Logic Diagram Swithgear Breaker Control 480V Service. Actual Drawing NUMBER:6Z-01-9-Z-40422 1)
- ML20261L974 + (Reference Logic Diagram:Mcc Starter Control)
- ML20261L852 + (Reference Logic Diagram:Mcc Starter Control)
- ML20261L948 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L943 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L965 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L926 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L933 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L937 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L952 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L958 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L587 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L533 + (Reference Logic Diagram:Motor Operated Valve)
- ML20261L543 + (Reference Logic Diagram:Motor Operated Valve)
- ML20260B139 + (Reference Logic Diagram:Switchgear Breaker Control 4.16 Kv ESF Service)
- ML20261L970 + (Reference Logic Diagram:Switchgear Breaker Control 4.16kV BOP Service)
- ML20261L980 + (Reference Logic Diagram:Switchgear Breaker Control 4.16kV M/U Rsvr)
- ML20261L836 + (Reference Logic Diagram:Switchgear Breaker Control 480V Service)
- ML20260B135 + (Reference Logic Diagram:Switchgear Breaker Control 480V Service)
- ML20261L602 + (Reference Logic Diagram:Switchgear Feeder Breaker Control 13.8 Kv Service)
- ML20260D210 + (Reference Logic Diaram Switchgear Breaker Control 4.16 Kv ESF Service. Actual Drawing NUMBER:4Z-01-9-Z-40402 1)
- ML20077M416 + (Reference Manual for the Contain 1.1 Code for Containment Severe Accident Analysis)
- ML20079Q811 + (Reference Materials for Nondestructive Assay of Special Nuclear Materials,Vol 1:Uranium Oxide Plus Graphite Powder)
- ML20261E967 + (Reference Plant Site Arrangement Single Unit.No Drawing Date)
- ML20039F812 + (Reference Repository Definition,Granite)
- ML20039F823 + (Reference Repository Definition,Shale)
- ML19284D392 + (Reference Simulator Inspection Report for Information)
- ML23354A260 + (Reference Simulator Inspection Request for Information)
- 05000289/FIN-2008004-02 + (Reference Test Conditions for MU-P-1B Not Established in Accordance with ASME OM Code)
- ML061420377 + (Reference Text for the Radwaste System)
- ML18219A728 + (Reference to Circular 76-05 Dated 10/7/1976 Regarding Hydraulic Shock and Sway Suppressors Manufactured by Itt Grinnell. APS Do Not Have Any of These Shock and Suppressors)
- ML18219A738 + (Reference to IE Bulletin 77-01, Arizona Public Service Co. Is Presently in the Process of Procuring Electrical Equipment, and Will Ensure No Ite Relays of the Type Described Are Used)
- ML18219A734 + (Reference to IE Bulletin 77-05 Which Discussed Failures of Certain Electrical Connectors Assemblies, Engineers of Arizona Public Service Co. Verified That There Are No Connectors of This Type Are Used)
- ML19095A219 + (Reference to Meeting of 5/10/1978, Furnishing Information Related to Completed Inspection of Unit 1 Outside Recirculation Spray Pump)
- ML19098B313 + (Reference to NRC Letter of 5/27/1975 Re VEPCOs Proposed Change to Tech Spec Involving Modification of High Steam Flow Points, Advising Meeting Has Been Scheduled on 6/13/1975 for Further Discussion)
- ML18127A545 + (Reference to Telephone Call of 5/16/1978, Enclosed Is Additional Information from Florida Power & Light Concerning Interruption of Off-Site Power to St. Lucie Plant on 5/14/1978)
- ML11301A222 + (Reference: Combined Heat and Power Effective Energy Solutions for a Sustainable Future)
- ML11301A225 + (Reference: Ohio Energy Fact Sheet)
- ML11301A236 + (Reference: Photovoltaic Solar Resource of the United States)
- ML11241A211 + (Reference: S0123-VI-1 0.1)
- ML11301A230 + (Reference: State Energy Consumption Estimates 1960 Through 2009)
- ML11301A239 + (Reference: Wind Resource Estimates Developed by Aws Truepower LLC for Windnavigator)
- ML20012G605 + (Referenced Simulator Certification Suppl Rept)
- ML060940258 + (References Associated with Request for Amendment to Unit 1 Facility Operating License Under Exigent Circumstances to Allow Use of Compensatory Measures During Certain Reactor Coolant Pump Operation)
- ML060970375 + (References Associated with Request for Amendment to Unit 1 Facility Operating License Under Exigent Circumstances to Allow the Use of Compensatory Measures During Certain Reactor Coolant Pump Operation)
- ML20148D826 + (References Comments in Matter of cross-examination of Consultants to ACRS at Licensing Proc Be Decided as Soon as Possible.Comm Will Consider the Matter on a Generic Basis Since Bd Agrees That It Is a top-level Policy Question)
- ML17083A222 + (References Indicating That Review of Equipment & Sys Uncovered Over 150 Violations of Separation Criteria. Requests plant-wide Field Audit of Installed Electric Equipment & Sys to Determine Conformance to Criteria)
- ML20134A694 + (References Info Recently Received by NRC Re Leaking Sources in Hauni Richmond Gauges,Six strontium-90 Sealed Sources Contained in Devices (Model 60-01-DR) Given Positive Leak Test Results.Response to Issued Raised Requested)
- ML19257B857 + (References NRC Re Continued Review of Containment Purge & Vent Valves.Forwards Request for Addl Info)
- ML19257B860 + (References NRC Re Continued Review of Containment Purge & Vent Valves.Forwards Request for Addl Info)
- ML13070A477 + (References Provided to Candidates 2012 Written Exam)