- ML19242D280 + (18:14:56, 4 January 2025)
- 05000295/LER-1979-044-99, /99x-0 on 790608:operators Manually Initiated Safety Injection After False Steam Pressure Differential Signals Caused Control Room Safety Injection Annunciation. Caused by Waterhammer Shock in Steam Generator Loop D + (18:14:58, 4 January 2025)
- ML19242D278 + (18:14:59, 4 January 2025)
- 05000295/LER-1979-044, Forwards LER 79-044/99X-0 + (18:15:00, 4 January 2025)
- ML19242D275 + (18:15:01, 4 January 2025)
- 05000304/LER-1979-040-03, /03L-0 on 790724:steam Generator Level 2L-538 Indicated 20% Higher than Other Channels for Steam Generator D.Caused by Faulty Power Supply,Model 4111085-001.Power Supply Replaced W/Calibr Spare + (18:15:03, 4 January 2025)
- ML19242D273 + (18:15:04, 4 January 2025)
- 05000263/LER-1979-015, Forwards LER 79-015/03L-0 + (18:15:09, 4 January 2025)
- ML19242D271 + (18:15:11, 4 January 2025)
- ML19242D270 + (18:15:13, 4 January 2025)
- 05000304/LER-1979-040, Forwards LER 79-040/03L-0 + (18:15:15, 4 January 2025)
- ML19242D266 + (18:15:17, 4 January 2025)
- 05000334/LER-1979-020-01, /01T-0 on 790724:during Insp,Inoperable Pipe Hanger Baseplate Observed.Caused by Improper Installation of Concrete Expansion Anchors in Baseplate Due to Lack of Formal Procedures During Initial Installation + (18:15:18, 4 January 2025)
- ML19242D264 + (18:15:19, 4 January 2025)
- ML19242D263 + (18:15:19, 4 January 2025)
- ML19242D262 + (18:15:20, 4 January 2025)
- ML19242D260 + (18:15:21, 4 January 2025)
- ML19242D259 + (18:15:22, 4 January 2025)
- ML19242D257 + (18:15:22, 4 January 2025)
- ML19242D256 + (18:15:23, 4 January 2025)
- ML19242D254 + (18:15:24, 4 January 2025)
- ML19242D252 + (18:15:24, 4 January 2025)
- 05000304/LER-1979-036-03, /03T-0 on 790703:while Boric Acid Tank Was Recirculating Unit 2 Boron Injection Tank,Boron Concentration Was Found to Be 11.2%,0.3% Above Tech Spec Max.Caused by Leakage from RCS + (18:15:26, 4 January 2025)
- 05000334/LER-1979-020, Forwards LER 79-020/01T-0 + (18:15:28, 4 January 2025)
- 05000304/LER-1979-036, Forwards LER 79-036/03T-0 + (18:15:30, 4 January 2025)
- 05000348/LER-1978-024-03, /03L-1 on 780408:while Changing Turbine Governor Valve Control,Load Rejection of Approx 170 MW Resulted in Momentary Temp Average Increase.Control Rods Automatically Initiated & Average Reduced + (18:15:31, 4 January 2025)
- ML19242D243 + (18:15:33, 4 January 2025)
- ML19242D239 + (18:15:34, 4 January 2025)
- 05000348/LER-1978-024, Forwards Updated LER 78-024/03L-1 + (18:15:35, 4 January 2025)
- L-79-173, Forwards Supplementary Response to IE Bulletin 79-06A Re Operating Procedures for Transients & Accidents + (18:15:36, 4 January 2025)
- ML19242D235 + (18:15:39, 4 January 2025)
- ML19242D232 + (18:15:40, 4 January 2025)
- ML19242D231 + (18:15:40, 4 January 2025)
- ML19242D229 + (18:15:41, 4 January 2025)
- ML19242D230 + (18:15:41, 4 January 2025)
- ML19242D228 + (18:15:42, 4 January 2025)
- ML19242D226 + (18:15:46, 4 January 2025)
- ML19242D224 + (18:15:47, 4 January 2025)
- ML19242D222 + (18:15:52, 4 January 2025)
- ML19242D220 + (18:15:53, 4 January 2025)
- ML19242D219 + (18:15:54, 4 January 2025)
- 05000366/LER-1979-086-03, /03L-0 on 790730:HPCI Sys Declared Inoperable When 2E41-F041 Valve Failed to Close When Initiated from Control Switch.Valve Failure Caused by Burned Motor.New Motor & Pinion Key Installed & Tested Satisfactorily + (18:15:57, 4 January 2025)
- 05000366/LER-1979-086, Forwards LER 79-086/03L-0 + (18:16:01, 4 January 2025)
- ML19242D212 + (18:16:03, 4 January 2025)
- TAC:13204 + (18:16:05, 4 January 2025)
- ML19242D211 + (18:16:06, 4 January 2025)
- 05000254/LER-1979-023-03, /03L-0 on 790717:high Pressure Switch in Safety Relief Valve Controller Found Inoperable During Reactor High Pressure Automatic Blowdown Functional test,QIS-40.Caused by Loosened Lead Wire from Switch to Terminal + (18:16:09, 4 January 2025)
- ML19242D209 + (18:16:35, 4 January 2025)
- ML19242D208 + (18:16:36, 4 January 2025)
- ML19242D206 + (18:16:37, 4 January 2025)
- ML19242D205 + (18:16:38, 4 January 2025)