- 05000346/LER-1977-101, Forwards LER 77-101/03L-0 + (21:45:02, 31 December 2024)
- 05000346/LER-1977-106, Forwards LER 77-106/03L-0 + (21:45:04, 31 December 2024)
- 05000346/LER-1977-093, Forwards LER 77-093/03L-0 + (21:45:09, 31 December 2024)
- 05000346/LER-1977-090, Forwards LER 77-090/03L-0 + (21:45:10, 31 December 2024)
- 05000346/LER-1977-086-03, /03L-0:on 771028,safety Features Actuation Sys Channel 4 Radiation Monitor RIS 2007 Failed to Respond to Internal Check Source.Caused by Component Failure.Low Amplifier Board Replaced & Monitor Recalibr + (21:45:12, 31 December 2024)
- 05000346/LER-1977-107, Forwards LER 77-107/03L-0 + (21:45:14, 31 December 2024)
- 05000346/LER-1977-108, Forwards LER 77-108/03L-0 + (21:45:15, 31 December 2024)
- 05000346/LER-1977-086, Forwards LER 77-086/03L-0 + (21:45:17, 31 December 2024)
- 05000346/LER-1977-094-03, /03L-0:on 771116,emergency Ventilation Sys Dampers Pdv 5014A & B Failed to Modulate Correctly to Draw Down Annulus.Caused by Defective Pressure Differential Controller.Dampers Replaced & Sys Retested + (21:45:19, 31 December 2024)
- 05000346/LER-1977-094, Forwards LER 77-094/03L-0 + (21:45:24, 31 December 2024)
- ML19326A481 + (21:45:26, 31 December 2024)
- ML19326A480 + (21:45:27, 31 December 2024)
- 05000346/LER-1977-095-03, /03L-0:on 771127,control Room Ventilation Isolation Damper HV 5311A Failed to Close on Radiation Monitor Trip.Caused by Component Failure.Damper Dismantled & Sealing Surfaces Cleaned & Lubricated + (21:45:28, 31 December 2024)
- ML19326A478 + (21:45:29, 31 December 2024)
- ML19326A477 + (21:45:30, 31 December 2024)
- ML19326A476 + (21:45:32, 31 December 2024)
- ML19326A475 + (21:45:33, 31 December 2024)
- 05000346/LER-1977-095, Forwards LER 77-095/03L-0 + (21:45:37, 31 December 2024)
- ML19326A471 + (21:45:42, 31 December 2024)
- ML19326A470 + (21:45:43, 31 December 2024)
- ML19326A469 + (21:45:45, 31 December 2024)
- 05000346/LER-1977-097-03, /03L-0:on 771129,radiation Monitor Re 2006 Tripped Safety Features Actuation Sys Channel 3 Containment Radiation Due to Sporadic Spiking.Caused by Component Failure in Radiation Detector.Detector Replaced + (21:45:46, 31 December 2024)
- ML19326A467 + (21:45:48, 31 December 2024)
- ML19326A466 + (21:45:49, 31 December 2024)
- ML19326A465 + (21:45:50, 31 December 2024)
- 05000346/LER-1977-097, Forwards LER 77-097/03L-0 + (21:45:51, 31 December 2024)
- ML19326A462 + (21:45:54, 31 December 2024)
- ML19326A461 + (21:45:54, 31 December 2024)
- ML19326A459 + (21:45:55, 31 December 2024)
- ML19326A460 + (21:45:55, 31 December 2024)
- ML19326A457 + (21:45:58, 31 December 2024)
- IR 05000346/1977017 + (21:46:03, 31 December 2024)
- ML19326A455 + (21:46:08, 31 December 2024)
- ML19326A453 + (21:46:10, 31 December 2024)
- ML19326A451 + (21:46:11, 31 December 2024)
- IR 05000346/1977018 + (21:46:13, 31 December 2024)
- ML19326A448 + (21:46:14, 31 December 2024)
- IR 05000346/1975009 + (21:46:15, 31 December 2024)
- ML19326A446 + (21:46:17, 31 December 2024)
- ML19326A445 + (21:46:18, 31 December 2024)
- ML19326A443 + (21:46:18, 31 December 2024)
- ML19326A442 + (21:46:20, 31 December 2024)
- 05000346/LER-1978-031-03, /03L-0:on 780325,control Room Ventilation Air Intake Chlorine Detectors 12-h Channel Check Not Recorded. Caused by Procedural Deficiency.Chlorine Detector Reading Inadvertently Deleted During Reading Sheet Revision 771111 + (21:46:21, 31 December 2024)
- 05000346/LER-1978-031, Forwards LER 78-031/03L-0 + (21:46:23, 31 December 2024)
- 05000346/LER-1978-037-01, /01T-0:on 780430,plant Procedure Violated During Maint Shutdown.Caused by Personnel Error & Procedure Inadequacy.Plant Shutdown & Cooldown Procedure Mod Prepared to Keep RCS Above 280 F If Cooldown Line Isolated + (21:46:25, 31 December 2024)
- 05000346/LER-1978-037, Forwards LER 78-037/01T-0 + (21:46:27, 31 December 2024)
- 05000346/LER-1978-035-03, /03L-0:on 780408,hydrogen Dilution Blower 1-1 Motor Breaker Tripped on Overload During Test Run.Caused by Sticking Suction Check Valve.Valves Cleaned & re-assembled. Check Valve Internals Removal Requested + (21:46:29, 31 December 2024)
- 05000346/LER-1978-035, Forwards LER 78-035/03L-0 + (21:46:31, 31 December 2024)
- 05000346/LER-1978-034-03, /03L-0:on 780326,group 5, Control Rods 11 & 12 Absolute Position Indication Declared Inoperable.Caused Traced to Penetration Area.Updated Rept Will Be Submitted When Exact Cause Determined + (21:46:32, 31 December 2024)
- 05000346/LER-1978-034, Forwards LER 78-034/03L-0 + (21:46:35, 31 December 2024)
- IR 05000346/1972001 + (21:46:37, 31 December 2024)