Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- B10554, Interim Deficiency Rept Re Cracking of Control Rod Guide Tube Support Pins.Initially Reported on 800405.Westinghouse Evaluating Problem.Next Rept Will Be Provided by 821116 + (15:46:46, 26 May 2025)
- CAC:MF7207 + (15:47:42, 26 May 2025)
- ML20069J456 + (15:48:00, 26 May 2025)
- ML20069J359 + (15:48:11, 26 May 2025)
- HL-4561, Application for Amends to Licenses DPR-57 & NPF-5,revising TS to Allow Testing Planned at Plant to Demonstrate Capability to Operate Plant Up to Core Power Level of 2,558 Mwt + (15:48:16, 26 May 2025)
- ML20069J165 + (15:48:31, 26 May 2025)
- ML20069J045 + (15:48:47, 26 May 2025)
- ML20069H900 + (15:49:03, 26 May 2025)
- 05000254/LER-1982-020, Forwards LER 82-020/03L-0 + (15:49:54, 26 May 2025)
- TAC:49027 + (15:50:53, 26 May 2025)
- 05000346/LER-1979-076-03, Core Flood Tank 1-1 Level Alarm Received.Caused by Faulty Amplifier in Level Transmitter LT-CF3B2,resulting in Incorrect Reading. Amplifier Replaced & Transmitter Recalibr + (15:51:21, 26 May 2025)
- 05000346/LER-1979-076, Forwards Revised LER 79-076/03X-1 + (15:51:23, 26 May 2025)
- 05000338/LER-1982-061-03, /03L-0:on 820917,during Chemistry Log Review, Specific Activity of Primary Coolant Exceeded Tech Specs. Caused by Migration of I-131 Through Pinhole Leaks in Fuel Cladding.Specific Activity Returned to Acceptable Limits + (15:51:36, 26 May 2025)
- 05000338/LER-1982-061, Forwards LER 82-061/03L-0 + (15:51:41, 26 May 2025)
- 05000317/LER-1980-041-01, 5 Minutes After Svc,Water Head Tanks Went from Normal Operating Level to Full,Isophase Bus Duct Cooling Low Flow Alarm Received.Caused by Air Compressor Failure Due to Cracked After Cooler Tubes + (15:51:51, 26 May 2025)
- 05000317/LER-1980-041, Forwards Updated LER 80-041/01X-1 + (15:51:58, 26 May 2025)
- 05000263/LER-1982-016, Forwards LER 82-016/01T-0 + (15:52:00, 26 May 2025)
- ML20069G698 + (15:52:34, 26 May 2025)
- TAC:49704 + (15:53:30, 26 May 2025)
- 05000293/LER-1982-038-03, /03L-0:on 820817,while Starting Up from Cold Shutdown,Reactor Core Isolation Cooling Steam Line High Differential Pressure Alarm Received.Caused by Air in Sensing Lines to Differential Pressure Switches + (15:54:48, 26 May 2025)
- OIG-17-A-08, Status of Recommendations: Audit of the Nuclear Regulatory Commissions Oversight of Source Material Exports to Foreign Countries Dated March 9, 2020 + (15:55:14, 26 May 2025)
- ML20069F278 + (15:55:56, 26 May 2025)
- ML20069F274 + (15:55:58, 26 May 2025)
- ML20069F266 + (15:56:00, 26 May 2025)
- ML20069F047 + (15:56:45, 26 May 2025)
- NUREG-0799, Guidelines for the Preparation of Emergency Operating Procedures.Resolution of Comments on NUREG-0799 + (15:56:58, 26 May 2025)
- 05000282/LER-1982-021, Forwards Revised LER 82-021/03X-1 + (15:57:07, 26 May 2025)
- TXX-9408, Requests Approval of Attached Rev to FSAR Description of Biennial Review of Safety Related Plant Procedures,Which Is Part of Previously Accepted CPSES QA Program.Proposes to Modify Commitment to Perform Biennial Reviews + (15:58:16, 26 May 2025)
- ML20069E327 + (15:58:25, 26 May 2025)
- 05000321/LER-1980-055-01, During Cold shutdown,45 Out of 61 Mechanical Snubbers Found to Be Locked Up.Caused by Corrosion of Snubbers.All But Three Snubbers Replaced W/Pacific Scientific Snubbers + (15:58:40, 26 May 2025)
- 05000321/LER-1980-055, Forwards Updated LER 80-055/01X-2 + (15:58:42, 26 May 2025)
- 05000499/LER-1993-013, :on 930719,inadvertent ESF Actuation Occurred Due to Component Cooling Water Pump Start During Maint Work Activity.Caused by Inadequate Plant Inpact Review.Time Delay Placed in CCW Pump + (15:59:21, 26 May 2025)
- 05000324/LER-1982-131, Supplemental LER 82-131/03L-1:on 821206,one-half Automatic Reactor Scram Signal Received Due to Instrument Downscale Signal from Main Steam Line Radiation Monitor D, 2-D12-RM-K603D.Caused by Disconnection of Instrument Cable + (16:00:25, 26 May 2025)
- ML20069D236 + (16:00:58, 26 May 2025)
- 05000272/LER-1983-011, Forwards LER 83-011/01T-0.Detailed Event Analysis Encl + (16:01:00, 26 May 2025)
- 05000324/LER-1981-022-03, Primary Containment Atmospheric Control Suppression Pool Level Indicator, 2-CAC-LI-2601-3,gave Erratic Indication Level.Caused by Blockage in Water Supply Throttle Valve + (16:01:40, 26 May 2025)
- 05000324/LER-1981-022, Forwards Updated LER 81-022/03L-1 + (16:01:42, 26 May 2025)
- B14825, Provides Proposed Schedule for Resolution of Unresolved Items,Per NRC Transmitting Insp Rept 50-423/93-81 + (16:01:46, 26 May 2025)
- TAC:46832 + (16:02:05, 26 May 2025)
- 05000325/LER-1982-013-03, /03L-0:on 820121,while Cycling HPCI Sys Turbine Steam Supply Outboard PCIV,1-E4-F003,valve Motor Breaker Tripped on Magnetics.Caused by Failure of Valve Motor.Motor Rebuilt.Addl Info Will Be Submitted + (16:02:36, 26 May 2025)
- 05000325/LER-1982-013, Forwards LER 82-013/03L-0 + (16:02:44, 26 May 2025)
- ML20069C226 + (16:02:51, 26 May 2025)
- 05000366/LER-1982-008-03, /03L-0:on 820121,accumulator Alarm 10-39 Sounded & Was Declared Inoperable.Caused by Setpoint Drift.Switch Recalibr & Returned to Svc + (16:02:56, 26 May 2025)
- 05000366/LER-1982-008, Forwards LER 82-008/03L-0 + (16:03:00, 26 May 2025)
- 05000325/LER-1982-017-03, /03L-0:on 820128,E11-F048A Valve Found W/No Indication on RTGB During Normal Operation.Caused by Valve Breaker Magnetic Trip Tripping Breaker W/Valve in Open Position Due to Loose B & C Phase Power Leads + (16:03:05, 26 May 2025)
- LD-82-025, Forwards Sample Environ Test Rept of Type Which Will Be Generated by Use of Topical Rept on Class IE Qualification, CENPD-255.Rept Withheld (Ref 10CFR2.790) + (16:03:07, 26 May 2025)
- 05000325/LER-1982-017, Forwards LER 82-017/03L-0 + (16:03:10, 26 May 2025)
- 05000261/LER-1982-003-01, /01T-0:on 820209,pressurization of Boron Injection Tank Header Pressure Indicator PI-934 Observed Exceeding Psig Required by Tech Specs.Caused by Failure of Operator & Safety Valve SI-857A to Relieve Pressure + (16:03:30, 26 May 2025)
- 05000302/LER-1982-004, Forwards LER 82-004/01T-0 + (16:03:52, 26 May 2025)
- ML20069B899 + (16:04:03, 26 May 2025)
- ML20069B843 + (16:04:15, 26 May 2025)