- ML20073J488 + (13:12:36, 26 May 2025)
- ML20073J480 + (13:12:38, 26 May 2025)
- 05000281/LER-1983-009-03, /03L-0:on 830308,during Routine Walkdown,Breaker for Heat Tracing Circuit 2 Panel 9 Found Tripped.Caused by Section of Circuit 2 Being Wired Incorrectly.Wiring Problem Corrected + (13:12:41, 26 May 2025)
- 05000338/LER-1983-005-03, /03L-0:on 830313,individual Rod Position Indication for Rod G-13 in Shutdown Bank a Deviated from Group Demand Position.Caused by Instrument Drift.Problem Generic to Westinghouse Analog Position Indication Sys + (13:12:42, 26 May 2025)
- ML20073J321 + (13:12:53, 26 May 2025)
- ML20073J132 + (13:13:37, 26 May 2025)
- ML20073J085 + (13:13:41, 26 May 2025)
- ML20073J075 + (13:13:43, 26 May 2025)
- ML20073J029 + (13:13:50, 26 May 2025)
- ML20073J021 + (13:13:52, 26 May 2025)
- ML20073H982 + (13:13:57, 26 May 2025)
- ML20073H772 + (13:15:09, 26 May 2025)
- TAC:M84076 + (13:15:12, 26 May 2025)
- TAC:49707 + (13:15:16, 26 May 2025)
- 05000414/LER-1994-004-03, :on 940830,missed Inservice Valve Stroke Time for Valves 2KC82B & 2NM200B Were Discovered During Engineering Self Assessment.Caused by Work Practices.Revised Affected Procedures + (13:16:21, 26 May 2025)
- 05000361/LER-1994-004, :on 940619,HPSI Pump P017 Was Removed from Service & Declared Inoperable.Caused by Incomplete & Inadequate Evaluation of Work Planned for P017 & ME417.All Equipment Personnel Have Received Training + (13:16:27, 26 May 2025)
- A830012, Responds to Generic Ltr 82-33,Suppl 1 to NUREG-0737, Requirements for Emergency Response Capability. Overall Strategy for Implementation of Requirements Discussed. Proposed Implementation Schedule Forwarded + (13:16:32, 26 May 2025)
- ML20073H237 + (13:16:42, 26 May 2025)
- 05000311/LER-1983-002, Forwards LER 83-002/03L-0.Detailed Event Analysis Encl + (13:17:07, 26 May 2025)
- ML20073H005 + (13:17:22, 26 May 2025)
- ML20073F768 + (13:19:42, 26 May 2025)
- 05000282/LER-1993-007, :on 930413,feedwater System Revealed That Certain Feedwater Valves Required to Mitigate Consequences of Accident Were Not Included in Insp.Caused by Personnel Error.All Valves Will Be Tested + (13:20:23, 26 May 2025)
- 05000499/LER-1993-006, :on 930217,TS Violated Due to Train a Cold Leg Injection MOV Being Inoperable for Greaterthan 72 H.Adequacy of Programmatic Controls Re Operability Determination Evaluated & Enhancements Made + (13:21:02, 26 May 2025)
- TXX-9108, Rev 4 to Technical Requirements Manual + (13:21:07, 26 May 2025)
- ML20073E654 + (13:21:28, 26 May 2025)
- 05000260/LER-1991-006, :on 910329,unplanned Reactor Protection Sys Actuation Occurred During Average Power Range Monitor B Drifted High & Exceeded Setpoint.Caused by Unexpected Failure.Affected Components Replaced + (13:21:35, 26 May 2025)
- TXX-9110, Provides Response to Re Violations Noted in Insp Repts 50-445/90-47 & 50-446/90-47.Corrective Actions:Plant Took Several Actions to Ensure Proper Preparation of Facility Scaling Calculations,Including Appropriate Unit + (13:21:40, 26 May 2025)
- TAC:42511 + (13:21:55, 26 May 2025)
- TAC:73771 + (13:22:00, 26 May 2025)
- ML20073D254 + (13:23:50, 26 May 2025)
- ML20073C847 + (13:24:43, 26 May 2025)
- TXX-9417, Requests Exemption from Submittal Schedule of Periodic Updates to FSAR Required by 10CFR50.71(e).Informs That Requested Exemption Would Require Periodic Updates Annually or Once Per Fuel Cycle + (13:26:23, 26 May 2025)
- 05000346/LER-1981-073-03, Neither Position Indicating Light on Valve AF608 Lit Due to Source Breaker BE1150 to MCCE11E Left Open.Caused by Const Worker Bumping Switch + (13:26:51, 26 May 2025)
- ML20073B517 + (13:27:05, 26 May 2025)
- ML20073B363 + (13:27:25, 26 May 2025)
- ML20073A010 + (13:29:22, 26 May 2025)
- 05000317/LER-1981-083-03, Relief Valve on Waste Evaporator Condensate Recovery Tank Lifted.Caused by Gas Analyzer Components Exposed to Moisture.Analyzer Cabinets Redesigned & Environmentally Qualified + (13:30:05, 26 May 2025)
- 05000317/LER-1981-083, Forwards Updated LER 81-083/03X-1 + (13:30:12, 26 May 2025)
- ST-HL-AE-4879, Responds to NRC Re Violation Noted in Insp Rept 50-498/94-17.Corrective Actions:Required Flow Through Essential Chiller Essential CW Outlet Bypass Valve Verified for Units 1 & 2 150 Ton & 300 Ton Essential Chillers + (13:30:30, 26 May 2025)
- 05000387/LER-1983-035-03, /03L-0:on 830228,4 H Surveillance of RCS Unidentified Leakage Not Performed Due to Inoperability of One of Two Drywell Floor Drain Sump Level Monitoring Devices at One of Two Sys Channels.Pump a Used to Pump Sump + (13:31:45, 26 May 2025)
- ML20072U356 + (13:32:02, 26 May 2025)
- 05000316/LER-1981-027-03, Reactor Trip Occurred. Caused by Failed C-2 Capacitor & Blown Fuse.Fuse & Capacitor Replaced + (13:32:37, 26 May 2025)
- 05000316/LER-1981-027, Forwards Updated LER 81-027/03X-2 + (13:32:40, 26 May 2025)
- TAC:49198 + (13:33:48, 26 May 2025)
- ML20072T126 + (13:34:10, 26 May 2025)
- 05000259/LER-1980-011-01, Analysis Indicated Potential Loss of Primary Containment During Hot Standby. Caused by Not Considering Probability of LOCA in Initial Plant Design.Mods to Ductwork Completed + (13:34:24, 26 May 2025)
- 05000259/LER-1980-011, Forwards Updated LER 80-011/01X-5 + (13:34:25, 26 May 2025)
- L-75-474, Interim Deficiency Rept Re Leaking Field Welds on Lines. Investigation Still in Progress.Next Rept Expected by 751031 + (13:35:42, 26 May 2025)
- L-76-186, Forwards Info Requested in 760505 Telcon Re Mechanical Snubber Failures + (13:35:50, 26 May 2025)
- L-76-245, Informs That safety-related Hydraulic Pipe Restraints Located Outside Containment Passed 760530 Insp + (13:35:54, 26 May 2025)
- ML20072S446 + (13:35:56, 26 May 2025)