Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20107J633 + (00:02:00, 26 May 2025)
- ML20107J625 + (00:02:02, 26 May 2025)
- EPID:L-2019-LLR-0100 + (00:02:23, 26 May 2025)
- 05000321/LER-1981-035-03, /03X-1:on 810426,standby Svc Water Sys Would Not Deliver Rated Flow.Caused by Svc Water Isolation Valve 1P41-F402A Not Opening.Valve Repaired & Successfully Retested + (00:03:55, 26 May 2025)
- ML20107H298 + (00:04:02, 26 May 2025)
- ML20107H170 + (00:04:12, 26 May 2025)
- IR 05000272/2020010 + (00:04:17, 26 May 2025)
- 05000247/LER-1983-029-03, /03L-1:on 830720,analysis Revealed Absorption Efficiencies for Methyliodine of 92.9 & 95% in Charcoal Filters.Caused by Change in Acceptance Criteria.Charcoal Replaced + (00:07:43, 26 May 2025)
- ML20107G065 + (00:08:36, 26 May 2025)
- IR 05000219/1973023 + (00:14:10, 26 May 2025)
- IR 05000219/1974013 + (00:19:03, 26 May 2025)
- TAC:48644 + (00:29:36, 26 May 2025)
- ML20107B039 + (00:29:49, 26 May 2025)
- IR 05000219/1973006 + (00:30:24, 26 May 2025)
- ML20107A193 + (00:31:19, 26 May 2025)
- TAC:51613 + (00:31:39, 26 May 2025)
- ML20106J813 + (00:33:00, 26 May 2025)
- ML20106J553 + (00:33:26, 26 May 2025)
- ML20106J132 + (00:33:51, 26 May 2025)
- 05000327/LER-1984-030, :on 840419,high Pressure Connection on Thimble Tube at Seal Table Failed,Resulting in RCS Pressure Boundary Leak & Ejection of Thimble Tube.Caused by Unusual Forces on Assembly by Cleaning Fixture + (00:34:02, 26 May 2025)
- ML20106F616 + (00:36:30, 26 May 2025)
- ML20106E852 + (00:38:33, 26 May 2025)
- TAC:M84223 + (00:41:56, 26 May 2025)
- 05000219/LER-1984-020, :on 840910,power Lost to Buses 1A2 & 1B2, Resulting in Full Scram.Caused by Faulty Overcurrent Device Causing Breaker 1B2M to Trip on Overload Due to Current Surge.Defective Device Replaced & Tested + (00:42:35, 26 May 2025)
- 05000282/LER-1992-010-01, :on 920827,determined That Requirement to Test Steam Explosion Sys Check Dampers Not Met.Caused by Failure to Include Dampers in Surveillance Procedures to Satisfy Ts.Damper Cleaned & Inspected + (00:43:10, 26 May 2025)
- ML20106A469 + (00:45:04, 26 May 2025)
- ML20105D004 + (00:46:16, 26 May 2025)
- ML20105C984 + (00:46:20, 26 May 2025)
- ML20105C825 + (00:46:34, 26 May 2025)
- TAC:53493 + (00:47:07, 26 May 2025)
- TAC:49804 + (00:47:15, 26 May 2025)
- TAC:M74419 + (00:47:28, 26 May 2025)
- TAC:51342 + (00:47:49, 26 May 2025)
- ML20105A482 + (00:50:41, 26 May 2025)
- ML20105A371 + (00:50:59, 26 May 2025)
- RS-20-028, 1 to Updated Safety Analysis Report, CPS TSB + (00:51:23, 26 May 2025)
- ML20104C147 + (00:52:16, 26 May 2025)
- PMNS20200241, Recriticality and Boron Redistribution (Audit Status Update) + (00:52:19, 26 May 2025)
- OIG-15-A-12, OIG Audit Status Update to OIG-15-A-12 04-13-20 + (00:52:31, 26 May 2025)
- 05000499/LER-1992-005, :on 920508,CVI Actuation Occurred Due to Failure in RM-23A Module.Definite Cause of Equipment Failure Has Not Been established.RM-23A Module Replaced & Review of Module Maint History Performed + (00:53:50, 26 May 2025)
- 05000265/LER-1992-020-01, :on 920811,declared RCIC Inoperable Retroactive Due to Failure of Egm/Egr Controller.Component Will Be Sent to Mfg for Insp,Rebuilding & Identification of Exact Problem + (00:54:19, 26 May 2025)
- 05000352/LER-1984-039, :on 841221,reactor Water Cleanup Sys,Reactor Encl & Refuel Floor Ventilation Sys Isolated.Caused by Overvoltage of Static Inverter.Scram Reset + (00:59:01, 26 May 2025)
- 05000413/LER-2020-001, Valid Actuation of the Unit 1 Reactor Protection System and Auxiliary Feedwater System + (00:59:07, 26 May 2025)
- ML20102C148 + (00:59:46, 26 May 2025)
- 05000368/LER-1981-033-04, /04X-1:on 810909,during Mode 1 Operation,Condenser Offgas Radiation Monitor Identified as Having Been Inoperable for 7 Days.Caused by Erratic Radiation Element Signal Due to Moisture build-up in Piping + (00:59:58, 26 May 2025)
- 05000265/LER-1985-001-07, :on 850125,while Performing Weekly turbine- Generator Test,Control Valve 4 fast-closed,causing Reactor Scram.Caused by Worn Bushing on Control Valve Switch Box Actuating Rod.Actuation Rod Replaced + (01:00:03, 26 May 2025)
- 05000280/LER-1985-006, :on 850128,reactor Trip Occurred Due to Differential Pressure anti-motoring Turbine Trip.Caused by Isolation of Exhaust Pressure Sensing Line Root Valve in anti-motoring Instrumentation.Plant Returned to Svc + (01:00:05, 26 May 2025)
- 05000280/LER-1985-004, :on 850127,reactor Tripped Due to Closing of Four Turbine Stop Valves.Caused by Insufficient Consideration of Steam Leakage Effect on Plant Parameters. Plant Parameters Returned to Stable Conditions + (01:00:07, 26 May 2025)
- 05000335/LER-1985-001-01, :on 850125,ECCS Area Ventilation Fan HVE-9B Inadvertently Placed Out of Svc for Maint W/Redundant Fan HVE-9a Already Out of Svc.Cause Unknown.Fan HVE-9B Returned to Svc + (01:00:08, 26 May 2025)
- 05000280/LER-1985-003, :on 850126,reactor Tripped Due to Voltage Transient Induced on Vital Bus I When Momentary Overload Condition Caused Circuit Breaker 13 to Trip Open.Cause Unknown.Plant Returned to Stable Condition + (01:00:10, 26 May 2025)