Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19340B270 + (23:46:03, 24 December 2024)
- 05000293/LER-1980-067, Forwards LER 80-067/01T-0 + (23:46:06, 24 December 2024)
- ML19340B266 + (23:46:07, 24 December 2024)
- 05000293/LER-1980-068, Forwards LER 80-068/03L-0 + (23:46:08, 24 December 2024)
- 05000344/LER-1980-020-01, /01T-0:on 801003,following Reactor Trip,Both Trains of Auxiliary Feedwater Pumps Failed to Respond to Automatic Start Signal.Pumps Were Manually Started.Caused by Incorrectly Wired Slave Relay + (23:46:14, 24 December 2024)
- ML19340B257 + (23:46:15, 24 December 2024)
- 05000306/LER-1980-027-03, /03L-0:on 800919,steam Flow Transmitter 2FT-474 Found Reading Low.Caused by Zero Adjustment Shift in Barton Model 384 Differential Pressure Transmitter. Transmitter Recalibr.Transmitters Scheduled to Be Replaced + (23:46:17, 24 December 2024)
- 05000344/LER-1980-020, Forwards LER 80-020/01T-0 + (23:46:20, 24 December 2024)
- 05000327/LER-1980-113-01, /01T-0:on 800926,while Exiting Containment Through Upper Containment Airlock,Employee Allowed Inner Door to Slam & Bounce Back.Latch Then Closed Blocking Door Ajar. Caused by Improper Adjustments on Door Operating Mechanism + (23:46:24, 24 December 2024)
- 05000259/LER-1980-073-01, /01T-0:on 800928,during Steady State Operation, River Water Temp Peaked at 5.1 F Temp Difference.Situation Recurred Next Day.Caused by Incorrect River Temp Rise Predictions.Events Are Random Occurrences + (23:46:27, 24 December 2024)
- 05000338/LER-1980-084-01, /01T-0:on 801002,Westinghouse Notified Util That High Steam Line Flow Setpoints Specified in PLS Document Are Less Conservative than Tech Specs Require.Caused by Calculation Assumptions Not Reflecting Installation + (23:46:28, 24 December 2024)
- 05000306/LER-1980-027, Forwards LER 80-027/03L-0 + (23:46:32, 24 December 2024)
- 05000327/LER-1980-113, Forwards LER 80-113/01T-0 + (23:46:33, 24 December 2024)
- 05000295/LER-1980-042-03, /03L-0:on 800912,area Monitor for Auxiliary Bldg Heating,Ventilation & Air Conditioning Filter Area Found Reading Erratically & Produced Periodic Alarms.Cause Not Determined.Monitor Functionally Tested & Returned to Svc + (23:46:35, 24 December 2024)
- 05000338/LER-1980-084, Forwards LER 80-084/01T-0 + (23:46:37, 24 December 2024)
- 05000295/LER-1980-042, Forwards LER 80-042/03L-0 + (23:46:39, 24 December 2024)
- ML19340B232 + (23:46:40, 24 December 2024)
- 05000324/LER-1980-063-03, /03L-0:on 800918,while Inerting Drywell, Primary Containment Gaseous Analyzer 2-CAC-AT-1259 Found Tracking Improperly.Caused by Instrument Drift.Analyzer Recalibr.Mod Written to Replace Monitors + (23:46:41, 24 December 2024)
- 05000333/LER-1980-076-04, /04T-0:on 801002,environ Radiological Monitoring Revealed Activity in Periphyton Organisms Near Site to Be Greater than Ten Times Control Sample for Co-60.Evaluation Does Not Indicate Significant Environ Impact + (23:46:44, 24 December 2024)
- ML19340B223 + (23:46:45, 24 December 2024)
- 05000324/LER-1980-063, Forwards LER 80-063/03L-0 + (23:46:46, 24 December 2024)
- 05000333/LER-1980-076, Forwards LER 80-076/04T-0 + (23:46:48, 24 December 2024)
- BSEP-80-1731, Ro:In Reviewing Containment Atmospheric Dilution Sys, Determined Relay in Logic Circuit Does Not Meet FSAR Requirements.Operating Procedures Revised to Include Jumpering of Contacts + (23:46:49, 24 December 2024)
- ML19340B215 + (23:46:51, 24 December 2024)
- ML19340B214 + (23:46:52, 24 December 2024)
- 05000267/LER-1980-050-03, /03L-0:on 800915,during Piping Audit,Two Hydraulic Snubbers Installed on Class I Piping Were Not Routinely Tested.Caused by Snubbers Omitted from Testing Table Due to Oversight.Procedure Revised + (23:46:55, 24 December 2024)
- 05000267/LER-1980-050, Forwards LER 80-050/03L-0 + (23:46:58, 24 December 2024)
- 05000295/LER-1979-095-03, /03L-0:on 800718,while Performing Axial Power Distribution Monitoring Sys (Apdms) Surveillance w/P250 Computer,Surveillance Frequency Exceeded Tech Spec Limit by 10 Minutes.Caused by Operator Error + (23:47:00, 24 December 2024)
- ML19340B206 + (23:47:02, 24 December 2024)
- 05000298/LER-1980-035-03, /03L-0:on 800917,during Surveillance Testing, Gasket in Oil Supply to HPCI Stop Valve Actuator Failed, Causing Shutdown of HPCI Sys.Caused by Gasket of Improper Matl Being Used.Gasket Replaced W/Gasket of Proper Matl + (23:47:03, 24 December 2024)
- 05000293/LER-1980-069-01, /01X-0:on 801007,w/unit at 96% Steady State Power, Reactor Vessel 203-3A Safety Relief Valve Opened.Caused by Excessive Nitrogen Supply Pressure.Pressure Resulted in Leakage Through Solenoid Valve Into Valve Diaphragm + (23:47:05, 24 December 2024)
- 05000298/LER-1980-035, Forwards LER 80-035/03L-0 + (23:47:07, 24 December 2024)
- 05000295/LER-1979-095, Forwards LER 79-095/03L-0 + (23:47:10, 24 December 2024)
- IR 05000186/2019202 + (23:47:25, 24 December 2024)
- 05000327/LER-1980-135-01, Ice Condenser Compartment Temp Exceeded Tech Spec Limit of 27 F.Caused by Ice Condenser Inlet Doors Being Open Due to Differential Pressure Created by Both Lower Compartment Doors Being Open + (23:47:29, 24 December 2024)
- ML19340B196 + (23:47:31, 24 December 2024)
- 05000298/LER-1980-034-03, /03L-0:on 800908,during Routine insp,4160-volt Breaker RHR Id Found Not Capable of Closing Automatically. Caused by Failure of GE Magna Blast 4160 Vac Breaker to Charge Rendering Pump Inoperable.Switch Replaced + (23:47:32, 24 December 2024)
- ML19340B193 + (23:47:33, 24 December 2024)
- ML19340B194 + (23:47:33, 24 December 2024)
- 05000298/LER-1980-034, Forwards LER 80-034/03L-0 + (23:47:38, 24 December 2024)
- ML19340B185 + (23:47:40, 24 December 2024)
- ML19340B184 + (23:47:40, 24 December 2024)
- ML19340B182 + (23:47:41, 24 December 2024)
- ML19340B183 + (23:47:41, 24 December 2024)
- ML19340B181 + (23:47:42, 24 December 2024)
- ML19340B180 + (23:47:43, 24 December 2024)
- ML19340B179 + (23:47:44, 24 December 2024)
- IR 05000313/1980014 + (23:47:46, 24 December 2024)
- ML19340B176 + (23:47:47, 24 December 2024)
- ML19340B174 + (23:47:48, 24 December 2024)
- ML19340B175 + (23:47:48, 24 December 2024)