Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19341A744 + (22:25:24, 24 December 2024)
- ML19341A743 + (22:25:33, 24 December 2024)
- IR 05000483/1980028 + (22:25:39, 24 December 2024)
- ML19341A740 + (22:25:45, 24 December 2024)
- ML19341A739 + (22:25:46, 24 December 2024)
- ML19341A736 + (22:25:52, 24 December 2024)
- ML19341A734 + (22:25:58, 24 December 2024)
- ML19341A735 + (22:25:58, 24 December 2024)
- 05000324/LER-1980-116-03, /03L-0:on 801231,pressure Switch 2-E11-PS-N010A Actuated Outside Tech Spec Limits.Caused by Instrument Drift.Switch Recalibr + (22:26:00, 24 December 2024)
- ML19341A732 + (22:26:01, 24 December 2024)
- 05000324/LER-1980-116, Forwards LER 80-116/03L-0 + (22:26:02, 24 December 2024)
- 05000324/LER-1980-118-03, /03L-0:on 801231,position Indication 38-11 Showed Superimposed 3 Over 8 Digit When at Position 48.Caused by Reed Switch Problem in Rod Prototypic Inlet Piping Probe. Problem Will Be Corrected During Next Available Outage + (22:26:04, 24 December 2024)
- 05000324/LER-1980-118, Forwards LER 80-118/03L-0 + (22:26:05, 24 December 2024)
- 05000298/LER-1980-050-03, /03L-0:on 801216,during Surveillance Testing of RHR Motor Operated valves,RHR-MO-25B,loop B Injection Line Inboard Isolation Would Not Open.Caused by Installation Error.Close Torque Switch Was Readjusted + (22:26:07, 24 December 2024)
- ML19341A725 + (22:26:08, 24 December 2024)
- 05000298/LER-1980-050, Forwards LER 80-050/03L-0 + (22:26:09, 24 December 2024)
- 05000254/LER-1980-033-03, /03L-0:on 801217,while Placing Standby Gas Treatment in Normal Standby Operation,Suction Valve MO-1-7503 Failed to Open from Control Room.Caused by Dirty Auxiliary Contacts.Contacts Were Cleaned & Replaced + (22:26:11, 24 December 2024)
- ML19341A720 + (22:26:18, 24 December 2024)
- 05000254/LER-1980-033, Forwards LER 80-033/03L-0 + (22:26:19, 24 December 2024)
- 05000265/LER-1980-038-03, /03L-0:on 801210,series of Six Trips Occurred on 2A Reactor Recirculation Pump Motor Generator Set Field Breaker.Caused by Defective Tachometer Which Controls Pump Speed.Tachometer Was Replaced on 801231 + (22:26:21, 24 December 2024)
- ML19341A716 + (22:26:22, 24 December 2024)
- ML19341A714 + (22:26:28, 24 December 2024)
- ML19341A715 + (22:26:28, 24 December 2024)
- 05000265/LER-1980-038, Forwards LER 80-038/03L-0 + (22:26:30, 24 December 2024)
- ML19341A711 + (22:26:36, 24 December 2024)
- ML19341A709 + (22:26:42, 24 December 2024)
- 05000295/LER-1980-055-03, /03L-0:on 801216,during Normal Operation,Gas Decay Tank Radiation Monitor ORT-PRO2B Was Taken Out of Svc for Maint & Grab Samples Were Not Taken for Two Shifts.Caused by Personnel Oversight.Personnel Reinstructed + (22:26:48, 24 December 2024)
- ML19341A707 + (22:26:49, 24 December 2024)
- 05000295/LER-1980-055, Forwards LER 80-055/03L-0 + (22:26:55, 24 December 2024)
- ML19341A704 + (22:26:56, 24 December 2024)
- ML19341A703 + (22:26:57, 24 December 2024)
- ML19341A701 + (22:27:04, 24 December 2024)
- ML19341A697 + (22:27:12, 24 December 2024)
- ML19341A698 + (22:27:12, 24 December 2024)
- 05000324/LER-1980-114-03, /03L-0:on 801229,low Level Switch 2B21-LIS-NO31D-3 Actuated Outside Tech Specs.Caused by Instrument Drift. Switch Recalibr + (22:27:26, 24 December 2024)
- ML19341A689 + (22:27:32, 24 December 2024)
- 05000324/LER-1980-114, Forwards LER 80-114/03L-0 + (22:27:36, 24 December 2024)
- ML19341A682 + (22:27:40, 24 December 2024)
- ML19341A681 + (22:27:41, 24 December 2024)
- ML19341A680 + (22:27:42, 24 December 2024)
- ML19341A677 + (22:27:43, 24 December 2024)
- ML19341A679 + (22:27:43, 24 December 2024)
- 05000320/LER-1980-057-03, /03L-0:on 801217,during Surveillance Procedure 4303-M10,air Intake Tunnel Chlorine Monitor Found Inoperable.Caused by Dirty Probe Which Reduced Sensitivity. Probe Removed,Cleaned & Returned to Svc + (22:27:51, 24 December 2024)
- ML19341A672 + (22:27:59, 24 December 2024)
- 05000282/LER-1980-038-31, /03L-0:on 801222,during Surveillance Test,One Steam Exclusion Actuation Bistable Tripped Above Tech Spec Limit.Caused by Drift of Foxboro Model 63U-CC-OHDR-F Bistable.Bistable Reinspected & Calibr + (22:28:01, 24 December 2024)
- ML19341A670 + (22:28:07, 24 December 2024)
- 05000298/LER-1980-048-03, /03L-0:on 801121,containment Oxygen Concentration Not Reduced to Less than 4% within 24-h of Placing Reactor in Run Mode.Cause Unknown.Procedures Will Be Revised to Reduce Potential for Recurrence + (22:28:08, 24 December 2024)
- ML19341A668 + (22:28:15, 24 December 2024)
- 05000298/LER-1980-048, Forwards LER 80-048/03L-0 + (22:28:16, 24 December 2024)
- 05000298/LER-1980-049-03, /03L-0:on 801120,MSIV 86A Had Slower Closure Time than Tech Specs Allowed.Cause Unknown.Closing Time Adjusted. Further Evaluations to Be Performed + (22:28:17, 24 December 2024)