- ML20033B460 + (15:17:20, 20 December 2024)
- ML20033B459 + (15:17:21, 20 December 2024)
- PNO-II-81-106, on 811125,transformer Failure Resulted in 15-minute Loss of Power to Control Room Annunciators. Annunciator Power Restored by Switching to Redundant Power Source.Caused by Primary Winding Fault in Transformer + (15:17:26, 20 December 2024)
- 05000364/LER-1981-048, Forwards LERs 81-041/03L-1 & 81-048/03L-0.W/o LER 81-048/03L-0 + (15:17:27, 20 December 2024)
- ML20033B454 + (15:17:29, 20 December 2024)
- 05000338/LER-1981-078-03, /03L-0:on 811111,axial Flux Difference Deviated More than -5% from Target for More than 12 Minutes.Caused by Rapid Power Reduction Necessitated by Fire on C Main Feedwater Pump.Boration Begun at Increased Rate + (15:17:31, 20 December 2024)
- 05000369/LER-1981-170-03, /03L-0:on 811025,temp Indication for Reactor Coolant Pump 1C Motor Upper Thrust Bearing Exceeded Limit. Apparently Caused by Corrosion on Screw Connections Where Thermocouple Cable Attaches in Terminal Cabinet + (15:17:33, 20 December 2024)
- ML20033B451 + (15:17:35, 20 December 2024)
- ML20033B448 + (15:17:37, 20 December 2024)
- 05000338/LER-1981-078, Forwards LER 81-078/03L-0 + (15:17:39, 20 December 2024)
- 05000369/LER-1981-170, Forwards LER 81-170/03L-0.Detailed Event Analysis Encl + (15:17:41, 20 December 2024)
- ML20033B443 + (15:17:42, 20 December 2024)
- 05000249/LER-1981-034-03, /03L-0:on 811026,source Range Monitor Channels 21 & 22 Found to Trip at Level Exceeding Tech Spec Limit.Caused by Drift of High Alarm Setpoint Potentiometer.Setpoints Adjusted + (15:17:46, 20 December 2024)
- 05000324/LER-1981-120-03, /03L-0:on 811102,core Spray or RHR Pumps Running Annunciator Received & No Abnormalities Found.Caused by Internal Moisture Accumulation Actuating Permissive Pressure Switch.Moisture Removed & Switch Calibr + (15:17:48, 20 December 2024)
- 05000249/LER-1981-034, Fowards LER 81-034/03L-0.Detailed Event Analysis Encl + (15:17:53, 20 December 2024)
- ML20033B435 + (15:17:55, 20 December 2024)
- 05000280/LER-1981-055-03, Both Charging Pump Svc Water Pumps Failed.Caused by Failure of Carbon Steel Cap Screw on One Pump Allowing Impeller to Bind & Shorting Out of Motor Stator Windings of Second Pump + (15:17:56, 20 December 2024)
- 05000324/LER-1981-120, Forwards LER 81-120/03L-0 + (15:17:58, 20 December 2024)
- ML20033B431 + (15:18:00, 20 December 2024)
- 05000280/LER-1981-066-03, /03L-0:on 811027,technical Review Found Not Yet Begun on Design Change Package That Relocated Portions of Yard Firemain Piping.Caused by Project Engineer Administrative Error.Documents Updated + (15:18:01, 20 December 2024)
- 05000324/LER-1981-122-03, /03L-0:on 811029,core Spray or RHR Pumps Running Annunciator Received & No Abnormalities Found.Caused by Inadequate Maint Permitting Corrosion to Actuate Switch & Cause Alarm.Switch Cleaned & Calibr + (15:18:04, 20 December 2024)
- ML20033B428 + (15:18:06, 20 December 2024)
- ML20033B427 + (15:18:07, 20 December 2024)
- 05000280/LER-1981-066, Forwards LER 81-066/03L-0 & Updated LER 81-055/03X-1 + (15:18:09, 20 December 2024)
- ML20033B424 + (15:18:11, 20 December 2024)
- 05000324/LER-1981-122, Forwards LER 81-122/03L-0 + (15:18:13, 20 December 2024)
- IR 05000373/1981016 + (15:18:14, 20 December 2024)
- 05000325/LER-1981-078-03, /03L-0:on 811104,primary Containment Isolation Valve Found Closed w/sealed-in Open Command Signal.Caused by Slight Binding of Valve Stem That Prevented Operator from Opening Valve After Manual Closure + (15:18:16, 20 December 2024)
- ML20033B417 + (15:18:29, 20 December 2024)
- 05000325/LER-1981-078, Forwards LER 81-078/03L-0 + (15:18:31, 20 December 2024)
- ML20033B414 + (15:18:32, 20 December 2024)
- A02055, Responds to NRC Re Violations Noted in IE Insp Repts 50-245/81-11 & 50-336/81-10.Corrective Actions:Waste Concentrator & Radwaste Operating Procedures Will Be Updated,Per Reg Guide 1.33 + (15:18:34, 20 December 2024)
- ML20033B411 + (15:18:36, 20 December 2024)
- IR 05000245/1981011 + (15:18:37, 20 December 2024)
- ML20033B408 + (15:18:42, 20 December 2024)
- ML20033B406 + (15:18:44, 20 December 2024)
- ML20033B405 + (15:18:45, 20 December 2024)
- ML20033B402 + (15:18:47, 20 December 2024)
- 05000325/LER-1981-080-03, /03L-0:on 811107,personnel Airlock Interior Door Leakage Rate Exceeded Limit.Caused by Door Roller Assembly Maladjustment Which Prevented Contact of Door & Door Frame Seating Surfaces.Roller Assembly Adjusted + (15:18:49, 20 December 2024)
- ML20033B400 + (15:18:51, 20 December 2024)
- ML20033B398 + (15:18:52, 20 December 2024)
- 05000324/LER-1981-119-03, /03L-0:on 811029,RHR Relay Logic a Power Failure Occurred Making LPCI Function of a RHR Subsystem Inoperable. Caused by Accidental Shorting to Ground of Instrument Power Supply Lead While Removing Wire from Switch Terminal + (15:18:54, 20 December 2024)
- 05000325/LER-1981-080, Forwards LER 81-080/03L-0 + (15:18:56, 20 December 2024)
- ML20033B394 + (15:18:58, 20 December 2024)
- 05000324/LER-1981-119, Forwards LER 81-119/03L-0 + (15:18:59, 20 December 2024)
- ML20033B390 + (15:19:01, 20 December 2024)
- 05000369/LER-1981-169-03, /03L-0:on 811021,channel 3 Monitoring Loss of Flow in Reactor Coolant Loop C Appeared to Be Out of Calibr & Declared Inoperable.Caused by Malfunctioning Flow Transmitter.Transmitter Replaced & Root Line Leak Repaired + (15:19:03, 20 December 2024)
- ML20033B388 + (15:19:04, 20 December 2024)
- 05000369/LER-1981-169, Forwards LER 81-169/03L-0.Detailed Event Analysis Encl + (15:19:06, 20 December 2024)
- IR 05000352/1981014 + (15:19:07, 20 December 2024)
- ML20033B382 + (15:19:10, 20 December 2024)