Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19309H228 + (07:20:35, 2 January 2025)
- ML19309H225 + (07:20:36, 2 January 2025)
- 05000321/LER-1980-037-03, /03L-0:on 800408,during Normal Operations & While Reviewing Surveillance schedule,post-LOCA Monitor Calibr Had Not Been Performed within Interval Required by Tech Specs. Caused by Personnel Oversight.Personnel Change Was Mad + (07:20:37, 2 January 2025)
- ML19309H223 + (07:20:38, 2 January 2025)
- ML19309H221 + (07:20:39, 2 January 2025)
- ML19309H219 + (07:20:40, 2 January 2025)
- ML19309H218 + (07:20:44, 2 January 2025)
- 05000321/LER-1980-037, Forwards LER 80-037/03L-0 + (07:20:45, 2 January 2025)
- ML19309H213 + (07:20:47, 2 January 2025)
- ML19309H215 + (07:20:47, 2 January 2025)
- 05000366/LER-1980-048-03, /03L-0:on 800415,while Checking Wiring Changes Made During Emergency Bus Alternate Supply Breaker Mod, Current Transformer Terminal Block 3 Found Burned at Termination Points.Caused by Loose Connection in Circuit + (07:20:49, 2 January 2025)
- ML19309H210 + (07:20:50, 2 January 2025)
- ML19309H211 + (07:20:50, 2 January 2025)
- ML19309H207 + (07:20:51, 2 January 2025)
- ML19309H209 + (07:20:51, 2 January 2025)
- ML19309H206 + (07:20:53, 2 January 2025)
- 05000366/LER-1980-048, Forwards LER 80-048/03L-0 + (07:20:54, 2 January 2025)
- ML19309H202 + (07:20:56, 2 January 2025)
- 05000366/LER-1980-051-03, /03L-0:on 800409,while Shutdown for Surveillance/ Vent Header Deflector Installation Outage,Dirty Radwaste Discharge Isolation Valve 2G11-F004 Found Leaking in Excess of Spec.Caused by Improper Sealing of Valve Gate + (07:20:57, 2 January 2025)
- 05000336/LER-1980-017-04, /04T-0:on 800424,during Routine Discharge of Waste Gas Decay Tank B,Discharge Flow Recorder Found Inoperable. Discharge Was Stopped.Caused by Dirty Clutch Drive Assembly. Clutch Drive Assembly Cleaned + (07:20:59, 2 January 2025)
- 05000366/LER-1980-051, Forwards LER 80-051/03L-0 + (07:21:00, 2 January 2025)
- 05000336/LER-1980-017, Forwards LER 80-017/04T-0 + (07:21:02, 2 January 2025)
- ML19309H195 + (07:21:03, 2 January 2025)
- ML19309H194 + (07:21:04, 2 January 2025)
- 05000366/LER-1980-046-03, /03L-0:on 800404,during 18-month Surveillance Procedure HNP2-3832,loss of Sys Pressure Was Simulated on Diesel Generator 2C & Bus 2G.Generator Started But Did Not Tie to Bus.Caused by Personnel Error + (07:21:09, 2 January 2025)
- 05000366/LER-1980-046, Forwards LER 80-046/03L-0 + (07:21:10, 2 January 2025)
- ML19309H190 + (07:21:13, 2 January 2025)
- ML19309H189 + (07:21:14, 2 January 2025)
- ML19309H188 + (07:21:14, 2 January 2025)
- ML19309H187 + (07:21:15, 2 January 2025)
- ML19309H186 + (07:21:16, 2 January 2025)
- 05000366/LER-1980-039-01, /01X-1:on 800411,during Normal Operation,Psw & RHR-SW Pump Motor Cooling Water Supply Did Not Meet Single Failure Criterion.Caused by Design Not Specifying Divisional Cooling Water Supply to Pumps + (07:21:18, 2 January 2025)
- ML19309H183 + (07:21:19, 2 January 2025)
- ML19309H182 + (07:21:20, 2 January 2025)
- IR 05000315/1980005 + (07:21:24, 2 January 2025)
- ML19309H180 + (07:21:25, 2 January 2025)
- ML19309H178 + (07:21:26, 2 January 2025)
- 05000366/LER-1980-039, Forwards LER 80-039/01X-1 + (07:21:27, 2 January 2025)
- ML19309H175 + (07:21:32, 2 January 2025)
- ML19309H174 + (07:21:40, 2 January 2025)
- ML19309H172 + (07:21:41, 2 January 2025)
- ML19309H171 + (07:21:43, 2 January 2025)
- 05000321/LER-1980-033-03, /03L-0:on 800402,while Inspecting CST Access Stairway,Cold Joint Between Original Base Slab & Added Slab for Retaining Walls Lacked Watertight Seal.Caused by Const Oversight.Maint Request Issued + (07:21:45, 2 January 2025)
- ML19309H169 + (07:21:45, 2 January 2025)
- 05000321/LER-1980-033, Forwards LER 80-033/03L-0 + (07:21:47, 2 January 2025)
- ML19309H166 + (07:21:48, 2 January 2025)
- ML19309H165 + (07:21:49, 2 January 2025)
- PNO-IV-80-017, site QA Supervisor Notified Resident Inspector of Mechanical Electrical Auxiliary Bldg Tilt.Possibly Caused by Heavier Loading of North End During Const.Condition Will Probably Be Corrected When Uniform Loading Is Achieved + (07:21:51, 2 January 2025)
- ML19309H160 + (07:21:53, 2 January 2025)
- ML19309H159 + (07:21:54, 2 January 2025)
- ML19309H157 + (07:21:55, 2 January 2025)