Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000295/LER-1980-020, Forwards LER 80-020/03L-0 + (07:12:07, 2 January 2025)
- 05000366/LER-1980-063-03, /03L-0:on 800421,w/reactor in Startup/Hot Standby Mode,D/W Torus Temp Recorder Found Inoperable.Caused by Loose Wire on Common Terminal Block on Recorder.Connection Tightened + (07:12:09, 2 January 2025)
- 05000282/LER-1980-014-03, /03L-0:on 800410,during Surveillance Test,One Overpower Delta T Setpoint Was Found to Trip About 70% Above Desired Setpoint.Caused by Intermittent Capacitor.Capacitor Was Replaced + (07:12:11, 2 January 2025)
- 05000366/LER-1980-063, Forwards LER 80-063/03L-0 + (07:12:13, 2 January 2025)
- 05000366/LER-1980-072, Forwards LER 80-072/03L-0 + (07:12:14, 2 January 2025)
- ML19309H592 + (07:12:16, 2 January 2025)
- 05000366/LER-1980-052-03, /03L-0:on 800408,during Maint of Standby Gas Treatment Sys,Power Cables to Heaters & Fans Found Undersized.Caused by Design Error.Cables Will Be Replaced by 800601 + (07:12:18, 2 January 2025)
- 05000282/LER-1980-014, Forwards LER 80-014/03L-0 + (07:12:20, 2 January 2025)
- ML19309H588 + (07:12:22, 2 January 2025)
- ML19309H587 + (07:12:23, 2 January 2025)
- 05000366/LER-1980-071-03, /03L-0:on 800424,during Routine Reactor Startup Activities,Reactor Core Isolation Cooling Leak Detection Logic Power Failure Alarm Was Received.Caused by Component Failure.Inverter Supporting Power Was Replaced + (07:12:25, 2 January 2025)
- ML19309H585 + (07:12:26, 2 January 2025)
- 05000346/LER-1980-033-01, /01T-0:on 800425,determined from Bechtel Study That Bleed Rate for 12 Hydraulic Snubbers Would Be Insufficient to Permit Thermal Growth of Piping During Transient Concurrent W/Locked Snubber + (07:12:27, 2 January 2025)
- 05000366/LER-1980-052, Forwards LER 80-052/03L-0 + (07:12:29, 2 January 2025)
- ML19309H581 + (07:12:30, 2 January 2025)
- ML19309H580 + (07:12:31, 2 January 2025)
- 05000346/LER-1980-033, Forwards LER 80-033/01T-0 + (07:12:32, 2 January 2025)
- 05000366/LER-1980-071, Forwards LER 80-071/03L-0 + (07:12:34, 2 January 2025)
- ML19309H575 + (07:12:35, 2 January 2025)
- ML19309H574 + (07:12:35, 2 January 2025)
- NUREG-0670, Discusses Comments on NUREG-0670, Study of Separation of Functions & Ex Parte Rules in NRC Adjudications for Domestic Licensing. Recommends Approval of Encl Draft Ltr to Senators Ribicoff & Culver + (07:12:39, 2 January 2025)
- 05000366/LER-1980-070-03, /03L-0:on 800422,while Performing Surveillance Procedure HNP-2-3405,reactor Core Isolation Cooling Trip & Throttle Valve Closed When Turbine Speed Reached 2,000 Rpm. Cause Not Identified.Trip & Throttle Valve Reset + (07:12:42, 2 January 2025)
- ML19309H570 + (07:12:44, 2 January 2025)
- ML19309H568 + (07:12:45, 2 January 2025)
- ML19309H569 + (07:12:45, 2 January 2025)
- ML19309H567 + (07:12:47, 2 January 2025)
- 05000366/LER-1980-070, Forwards LER 80-070/03L-0 + (07:12:48, 2 January 2025)
- ML19309H561 + (07:12:59, 2 January 2025)
- 05000295/LER-1980-016-03, /03L-0:on 800325,during Normal Operation,S/G Steam Flow Channel Was Found Reading Lower than Allowable Channel Tolerance.Caused by Excessive Process Noise from Transmitter.Transmitter Replaced & Channel Returned to Svc + (07:13:01, 2 January 2025)
- ML19309H559 + (07:13:02, 2 January 2025)
- ML19309H558 + (07:13:03, 2 January 2025)
- ML19309H557 + (07:13:10, 2 January 2025)
- 05000295/LER-1980-016, Forwards LER 80-016/03L-0 + (07:13:12, 2 January 2025)
- ML19309H554 + (07:13:14, 2 January 2025)
- 05000333/LER-1980-033-03, /03L-0:on 800409,during Normal Operation,Diesel Fire Pump Was Intentionally Made Inoperable for Approx 45 Minutes.Caused by Need to Replace Engine Cooling Heat Exchanger Goose Neck,Corroded Due to Normal Wear & Tear + (07:13:16, 2 January 2025)
- ML19309H552 + (07:13:17, 2 January 2025)
- ML19309H551 + (07:13:18, 2 January 2025)
- ML19309H549 + (07:13:19, 2 January 2025)
- ML19309H548 + (07:13:20, 2 January 2025)
- ML19309H547 + (07:13:21, 2 January 2025)
- 05000333/LER-1980-033, Forwards LER 80-033/03L-0 + (07:13:22, 2 January 2025)
- 05000333/LER-1980-032-04, /04L-0:on 800408,during First Quarter of 1980, Release of Halogens & Particulates w/half-lives of Greater than Eight Days Exceeded Ets.Caused by Packing Leak in RHR Sys.Tightened Packing as Temporary Corrective Action + (07:13:24, 2 January 2025)
- 05000333/LER-1980-032, Forwards LER 80-032/04L-0 + (07:13:26, 2 January 2025)
- ML19309H538 + (07:13:27, 2 January 2025)
- 05000327/LER-1980-031-03, /03L-0:on 800410,during Performance of Surveillance Instruction,Containment Spray Pump Check Valves Reported Leaking.Caused by Const Personnel Error.Disc & Related Parts Were Reinstalled + (07:13:28, 2 January 2025)
- ML19309H535 + (07:13:30, 2 January 2025)
- ML19309H533 + (07:13:31, 2 January 2025)
- ML19309H530 + (07:13:43, 2 January 2025)
- 05000327/LER-1980-031, Forwards LER 80-031/03L-0 + (07:13:45, 2 January 2025)
- ML19309H527 + (07:13:46, 2 January 2025)
- TAC:8595 + (07:13:46, 2 January 2025)