Forwards Geotechnical Design Data,Proposed Tailing Disposal Facility Expansion,Down Mining Co,Ford,Wa & Drawing for Assessment According to State Request for Tech Assistance
ML19309H570
Person / Time
Issue date: 04/28/1980
From: Kerr G
NRC OFFICE OF STATE PROGRAMS (OSP)
To: Scarano R
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML19309H571 List:
References
REF-WM-33 16202, NUDOCS 8005130512
Download: ML19309H570 (2)


Text

  • ~

pa tec 8

0 UNITED STATES gh hg 3

[ *y ).,,(/[$

NUCLEAR REGULATORY COMMISSION

./

.g

,p, l

W ASHING TON. D. C. 20555 8 55 % f APR 2 8 1980 Ref: SA/JF D

~

1980 liEM0RANDUM FOR:

R. Scarano, NMSS

~

,' "Q.w.,, y

  • %s G

FROM:

G. Wayne Kerr, OSP

" " =

'e

SUBJECT:

DAWN MINING COMPANY Attach are 7 copies of "Geotechnical Design Data, Proposed Tailing Disposal Facility Expansion Dawn Mining Company, Ford, Washington and 7 supplemental drawings by Kilborn Engineering.

Drawing No. 9419-13-001, Revision 1.

These documents were submitted, hand carried by L. Gronemyer, by the State of Washington, Radiation Control Section, for assessment according to the State's request for technical assistance on this project.

O G. Wayne serr, Assistant Director for State Agreements Program Office of State Programs

Enclosures:

As stated

';f N'qp 4:g!?o t

eg I m G

~

\\/

'?

FEEEXDPT 16202

e r

DAWN MINING COMPANY PO 00X 25 FOHD W A SHINGTON 99063 April 15, 1980 f1r. Terry Strong Head, Radiation Control Section Health Services Division Department of Social and Health Services P.O. Box 1788 Olympia, WA 98504

Dear fir. Strong:

Persuant to a suggestion made by Mr. R. Will and Mrs. N. Kirmer during the series of meetings held February 27, 28 and 29,1980 between Dawn flining Company, D.S.H.S., D.O.E., E.P. A and N.R.C., this letter is a formal request for an amendment to our present license (WN-1043-1).

This amendment request seeks a approval of a new tailings disposal facility which was originally proposed in Dawn's application for license renewal and accompaning environmental report, both submitted on July 31, 1979.

Since the two previously submitted documents describe the project and its environmental impacts in detail, only new information is sub-mitted at this time.

(In addition, the " Response to E.P.A. Comments on Tailings Disposal Facility", submitted by Dawn on February,1980, con-tained information pertaining to this project.)

Enclosed with this letter are copies of the following:

(1) Three drawings by Kilborn Engineering, LTD showing the latest design of the pit excavation, liner installation and underdrain system.

(2) A Golder Associates report, "Geotechnical Design Data, Proposed Tailings Facility Expansion - Dawn flining Company." which analyses the geotechnical characteristics of the project.

This includes slope design, subdrain stystem, construction materials, bulking factors, permeabilities, etc.

Being mailed seperately and addressed to firs. N. Kirmer are eleven additional copies of this letter and attachments.

Should you or any of your staff have any questions or need addit-ional information on this project please feel free to call on us.

Yours truly, DAWN MINING COMPANY I. E. Thomps % ^

^

J on l

Resident Manager g

Enc.

)

v re FDlp

l _ _ _ _. _ _ _. _.

i

{

GEOTECHtlICAL DESIGli DATA, PROPOSED TAILING DISPOSAL FACILITY EXPAtiSION DAWN MINING COMPANY l

FORD, WASHINGTON 1

i I

1 l

I

.i i

i I

1 i

1 i

l

\\

l l

\\

l l

i 16302 l

793-1158 November 2,1979 Golder Associates

- _