- ML20052A682 + (13:32:42, 18 December 2024)
- ML20052A679 + (13:32:51, 18 December 2024)
- ML20052A677 + (13:32:52, 18 December 2024)
- IR 05000305/1981027 + (13:32:53, 18 December 2024)
- ML20052A673 + (13:32:55, 18 December 2024)
- 05000364/LER-1982-010-03, /03L-0:on 820226,instrumentation Loop Associated w/LI-474 (Steam Generator a Level Indicator) Declared Inoperable.Caused by Loss of Necessary Level in Ref Leg While Steam Generator Not in Svc.Leg Refilled + (13:32:56, 18 December 2024)
- ML20052A670 + (13:33:01, 18 December 2024)
- ML20052A669 + (13:33:02, 18 December 2024)
- ML20052A668 + (13:33:03, 18 December 2024)
- 05000364/LER-1982-009-03, /03L-0:on 820228,instrumentation Loop Associated w/FT-474 (Steam Generator a Flow Transmitter) Declared Inoperable.Caused by Leaking Equalizing Valve.Valve Stem Repaired + (13:33:04, 18 December 2024)
- ML20052A665 + (13:33:06, 18 December 2024)
- ML20052A664 + (13:33:08, 18 December 2024)
- 05000364/LER-1982-008-03, /03L-0:on 820226,instrumentation Loop Associated w/LI-485 (Steam Generator B Level Indication) Declared Inoperable When Reading Was Out of Tolerance W/Other Channels.Caused by Obstruction in Ref Leg + (13:33:09, 18 December 2024)
- ML20052A662 + (13:33:10, 18 December 2024)
- 05000364/LER-1982-005-03, /03L-0:on 820226,4160-volt B Train Ac Electrical Power Circuit Declared Inoperable When Emergency Bus 2G de-energized.Bus 2G de-energized When Breaker 2-DG15 Opened. Cause Under Investigation + (13:33:11, 18 December 2024)
- ML20052A659 + (13:33:12, 18 December 2024)
- 05000348/LER-1982-013-03, /03L-0:on 820317,containment Atmosphere Activity Monitors R-11 (Particulate Monitor) & R-12 (Gaseous Monitor) Declared Inoperable Due to Failure of Vacuum Pump.Caused by Failed Outboard Pump.Filter & Gasket Replaced + (13:33:16, 18 December 2024)
- ML20052A656 + (13:33:18, 18 December 2024)
- PNO-II-82-042, on 820417,fire Discovered in Steam Generator Repair Bldg Located Near Unit 1.Both Reactors Not Affected by Fire.Fire Extinguished by Surry County Fire Dept & Plant Fire Brigade.Cause Not Known + (13:33:20, 18 December 2024)
- 05000348/LER-1982-013, Forwards LER 82-013/03L-0 + (13:33:24, 18 December 2024)
- ML20052A649 + (13:33:25, 18 December 2024)
- ML20052A647 + (13:33:26, 18 December 2024)
- ML20052A644 + (13:33:29, 18 December 2024)
- 05000369/LER-1982-022-03, /03L-0:on 820310,while in Mode 5,procedure Review Revealed Pressurizer 1 Power Operated Relief Valve (PORV) Had Not Been Timed.Procedure Change on 800915 Failed to Include PORV for Time Test.Procedure Changed + (13:33:30, 18 December 2024)
- PNO-II-82-047, on 820423,licensee Shut Down Plant to Begin Refueling & Inservice Insp Outage.During Outage,Util Will Inspect Steam Generators for Possible Internal Auxiliary Feedwater Header Damage Similar to Davis-Besse + (13:33:33, 18 December 2024)
- 05000369/LER-1982-022, Forwards LER 82-022/03L-0 + (13:33:34, 18 December 2024)
- 05000321/LER-1982-020-03, /03L-0:on 820318,oil Leak Found on Reactor Core Isolation Cooling Turbine Outboard Bearing Housing.Caused by Clogged Drain Orifice Inside Bearing Housing.Orifice Cleared + (13:33:36, 18 December 2024)
- 05000321/LER-1982-020, Forwards LER 82-020/03L-0 + (13:33:43, 18 December 2024)
- ML20052A632 + (13:33:44, 18 December 2024)
- 05000338/LER-1982-008-01, /01T-0:on 820329,Westinghouse Determined That Six Output Slave Relays Did Not Have Qualified Latching Mechanisms.Caused by Use of Two Different Types of Latches. Latching Mechanisms Will Be Replaced + (13:33:45, 18 December 2024)
- ML20052A627 + (13:33:50, 18 December 2024)
- 05000338/LER-1982-008, Forwards LER 82-008/01T-0 + (13:33:52, 18 December 2024)
- ML20052A624 + (13:33:53, 18 December 2024)
- ML20052A621 + (13:33:55, 18 December 2024)
- ML20052A620 + (13:33:56, 18 December 2024)
- 05000338/LER-1982-006-03, /03L-0:on 820305,during Mode 1 at 100% Power,A Svc Water Return Header from Units 1 & 2 Charging Pumps & Air Compressors Were Isolated to Repair Pinhole Leak in Return Line.Caused by Aggressive Water Corrosion + (13:33:57, 18 December 2024)
- ML20052A617 + (13:33:58, 18 December 2024)
- 05000321/LER-1982-012-03, /03L-0:on 820211,HPCI Auxiliary Oil Pump Failed to Perform During Procedure HNP-1-3318,HPCI, Hydraulic Oil Piping Moisture Protection. Cause Not Positively Identified.Suspected Components Replaced + (13:34:00, 18 December 2024)
- ML20052A615 + (13:34:01, 18 December 2024)
- ML20052A614 + (13:34:02, 18 December 2024)
- 05000338/LER-1982-006, Forwards LER 82-006/03L-0 + (13:34:03, 18 December 2024)
- 05000321/LER-1982-012, Forwards LER 82-012/03L-0 + (13:34:05, 18 December 2024)
- ML20052A607 + (13:34:06, 18 December 2024)
- ML20052A606 + (13:34:07, 18 December 2024)
- 05000321/LER-1982-016-03, /03L-0:on 820213,while Performing Routine Surveillance,Sample Pump for Fission Product Monitors Found Inoperable.Caused by Blown Fuse.Fuse Replaced & Sys Returned to Svc + (13:34:08, 18 December 2024)
- ML20052A604 + (13:34:09, 18 December 2024)
- 05000321/LER-1982-016, Forwards LER 82-016/03L-0 + (13:34:10, 18 December 2024)
- ML20052A601 + (13:34:11, 18 December 2024)
- ML20052A600 + (13:34:12, 18 December 2024)
- ML20052A599 + (13:34:13, 18 December 2024)