- 05000317/LER-1982-041-03, /03L-0:on 820713,channel a High Power,Thermal Margin/Low Pressure & Axial Shape Index Trip Units Bypassed to Allow Failing Hot Leg Temp Element Signal to Be Removed from Reactor Protective Sys.Caused by Changing Temp Element + (03:18:40, 17 December 2024)
- 05000317/LER-1982-041, Forwards LER 82-041/03L-0 + (03:18:41, 17 December 2024)
- 05000305/LER-1982-025-03, /03L-0:on 820716,during Document Review,Waste Disposal Liquid Effluent Monitor Found Indicating Low.Caused by Weak Detection Tube on Monitor.Tube Replaced & Detector Recalibr + (03:18:43, 17 December 2024)
- ML20062N427 + (03:18:44, 17 December 2024)
- ML20062N432 + (03:18:44, 17 December 2024)
- ML20062N421 + (03:18:45, 17 December 2024)
- 05000305/LER-1982-024-03, /03L-0:on 820716,while at Full Power,Overpower Delta T Channel 3 Rod Stop Alarm Observed Cycling in & Out. Caused by Malfunction of Tavg Signal Conditioner Causing Channel to Drift.Spare Signal Box Installed & Calibr + (03:18:47, 17 December 2024)
- LIC-93-0299, Forwards Application for Amend to License DPR-40,revising TS Surveillance Test Frequency from Monthly to Quarterly for Several Channel Functional Tests for RPS & ESF I&Cs,Per GL 93-05,based on NRC Approval of TR CEN-327-A & Tr,Suppl 1 + (03:18:48, 17 December 2024)
- ML20062N417 + (03:18:48, 17 December 2024)
- ML20062N412 + (03:18:49, 17 December 2024)
- ML20062N404 + (03:18:55, 17 December 2024)
- B14716, Requests Relief from ASME Boiler & Pressure Vessel Code Section XI Requirements,Per GL 90-05.Description of Actions Taken by Util to Repair Leak in SWS Piping Line 3SWP-010-028-3 as Alternative to IWA-4000/70005 Repair + (03:18:56, 17 December 2024)
- ML20062N388 + (03:18:56, 17 December 2024)
- JAFP-82-0543, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/82-01.Corrective Actions:Valves 250C & BAS-4 Repositioned to Agree W/Lineup List & Procedures Reviewed for Control of Plant Status + (03:18:58, 17 December 2024)
- ML20062N378 + (03:18:58, 17 December 2024)
- JAFP-82-0850, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/82-06.Corrective Actions:Operator Stationed at Portable Monitor to Continuously Monitor Containment Atmosphere + (03:19:02, 17 December 2024)
- ML20062N361 + (03:19:02, 17 December 2024)
- ML20062N347 + (03:19:03, 17 December 2024)
- ML20062N339 + (03:19:04, 17 December 2024)
- 05000318/LER-1982-021-03, LER-021/03L-0:on 820714,22B Safety Injection Tank Pressure Found Decreased to 197 Psig on 820427.Caused by Loop Isolator Failure.Isolator Replaced + (03:19:06, 17 December 2024)
- 05000328/LER-1981-136-03, /03L-0:on 811112,leak Discovered in Instrument Tubing for 2-PI-68-69 (RCS Wide Range Pressure Loop 3 Hotleg).Caused by Loose Fitting on Tubing.Fitting Tightened. Valves 2-68-548 & 578 Opened + (03:19:08, 17 December 2024)
- 05000328/LER-1981-136, Forwards LER 81-136/03L-0 + (03:19:09, 17 December 2024)
- 05000318/LER-1982-021, Forwards LER 82-021/03L-0 + (03:19:10, 17 December 2024)
- 05000321/LER-1981-123-03, /03L-0:on 811112,w/reactor in Shutdown for Core Reconstitution,High Bearing Temp Alarm Received in a RHR Svc Water Pump Motor.Caused by Mud & Sludge Buildup in Cooling Water Line.Mud & Sludge Removed + (03:19:12, 17 December 2024)
- ML20062N307 + (03:19:12, 17 December 2024)
- ML20062N306 + (03:19:13, 17 December 2024)
- ML20062N304 + (03:19:14, 17 December 2024)
- PLA-1236, Final Deficiency Rept Re Error in Backpressure Calculations for Main Steam Safety Relief Valve Adjusting Ring Settings. Initially Reported on 820714.GE Corrected Calculational Error.Also Reported Per Part 21 + (03:19:14, 17 December 2024)
- ML20062N296 + (03:19:17, 17 December 2024)
- 05000321/LER-1981-123, Forwards LER 81-123/03L-0 + (03:19:20, 17 December 2024)
- ML20062N276 + (03:19:20, 17 December 2024)
- 05000316/LER-1982-061-03, /03L-0:on 820717,while Performing Operability Test,Neither Fuel Oil Transfer Pump for Cd Emergency Diesel Generator Would Pump Fuel Oil to Day Tank.Caused by Failure of Nonoperating Pump Discharge Check Valve to Seat Properl + (03:19:22, 17 December 2024)
- 05000316/LER-1982-060-03, /03L-0:on 820717,during Normal Operation,Train a Heaters for Boron Injection Tank Declared Inoperable While Heater Controls Were Repaired.Caused by Faulty Resistance to Current Converter (R/I).Converter Replaced + (03:19:24, 17 December 2024)
- AECM-81-467, Final Deficiency Rept Re Incorrect Reactor Water Level Measuring Devices Initially Reported 810823.Wide Range Instrumentation Removed & Replaced W/Narrow Range Instrumentation.Also Reported Per Part 21 + (03:19:25, 17 December 2024)
- ML20062N265 + (03:19:26, 17 December 2024)
- 05000373/LER-1982-060-03, /03L-0:on 820717,during Operation of B Control HVAC Train,High Ammonia Level Alarm Went Off Inadvertently. Caused by Broken Tape in Detector.Tape Replaced + (03:19:28, 17 December 2024)
- 05000364/LER-1981-050-03, /03L-0:on 811116,penetration Room Filtration Sys 2A Declared Inoperable Due to Loss of Power to Pressure Differential for 2A Recirculation Fan.Caused by Blown Fuse in Pressure Differential Transmitter Power Supply + (03:19:30, 17 December 2024)
- 05000373/LER-1982-060, Forwards LER 82-060/03L-0 + (03:19:31, 17 December 2024)
- ML20062N250 + (03:19:31, 17 December 2024)
- 05000364/LER-1981-050, Forwards LER 81-050/03L-0 + (03:19:32, 17 December 2024)
- ML20062N239 + (03:19:32, 17 December 2024)
- 05000333/LER-1993-026, :on 931202,HPCI Sys Declared Inoperable Due to Failed Master Trip Unit in Steam Leak Detection Sys.Trip Unit Replaced & HPCI Sys Declared Operable on 931203.W/ + (03:19:34, 17 December 2024)
- ML20062N218 + (03:19:35, 17 December 2024)
- ML20062N216 + (03:19:36, 17 December 2024)
- ML20062N214 + (03:19:37, 17 December 2024)
- 05000373/LER-1993-018-04, :on 931205,closure of Primary Containment Isolation Valves Occurred Due to Failed Logic Card.Logic Card Replaced & Successfully Tested Under WR L25909.Failure Analysis of Card Will Be Performed + (03:19:38, 17 December 2024)
- ML20062N203 + (03:19:40, 17 December 2024)
- 05000366/LER-1981-112-03, /03L-0:on 811117,while Performing Flow Test, Reactor Core Isolation Cooling Sys Isolated on Turbine Exhaust Diaphragm High Pressure.Caused by Damaged Discharge Check Valve Creating Block in Line + (03:19:42, 17 December 2024)
- ML20062N190 + (03:19:43, 17 December 2024)
- ML20062N186 + (03:19:44, 17 December 2024)
- ML20062N183 + (03:19:44, 17 December 2024)
- ML20062N174 + (03:19:45, 17 December 2024)