- 05000361/LER-1983-017-03, /03L-0:on 830124,exam Confirmed Continuing Alarms on Containment High Range Radiation Monitor RI-7820 Were Defeating Function.Caused by 2 R/Hr Setpoint Being Too Close to Normal Reading.Tech Spec Amend to Be Submitted + (16:04:50, 16 December 2024)
- 05000395/LER-1983-011-03, /03L-0:on 830208 & 17,during Mode 1 Operation, Nuclear Sampling Sys Valves 9398 A,B & C Failed to Close. Caused by Limit Switch Failure on One Valve & Crud Buildup on Other Valve Seats.Crud Dislodged.Limit Switches Repaired + (16:04:55, 16 December 2024)
- 05000361/LER-1983-017, Forwards LER 83-017/03L-0 + (16:04:58, 16 December 2024)
- ML20069D126 + (16:04:58, 16 December 2024)
- ML20069D120 + (16:05:00, 16 December 2024)
- 05000333/LER-1993-019, :on 930923,potential Design Inadequacies in Control Room Ventilation Sys Occurred.Caused by Inadequate Design Control & Documentation by Engineering Organizations. CRV Placed in Isolate Mode of Operation + (16:05:02, 16 December 2024)
- 05000302/LER-1983-007-03, /03L-0:on 830209,reactor Bldg Pressure Indicator Discovered Inoperable.Caused by Instrument Drift.Transmitter Recalibr.Pressure Transmitters Will Be Replaced During Next Refueling Outage + (16:05:09, 16 December 2024)
- 05000395/LER-1983-011, Forwards LER 83-011/03L-0.Detailed Event Analyis Encl + (16:05:10, 16 December 2024)
- 05000302/LER-1983-007, Forwards LER 83-007/03L-0 + (16:05:14, 16 December 2024)
- ML20069D099 + (16:05:14, 16 December 2024)
- ML20069D096 + (16:05:15, 16 December 2024)
- ML20069D097 + (16:05:15, 16 December 2024)
- ML20069D087 + (16:05:16, 16 December 2024)
- ML20069D076 + (16:05:17, 16 December 2024)
- 3F0594-15, Responds to NRC Re Violations Noted in Insp Rept 50-302/93-16.Corrective Action:Developing an Operations Study Book Entry + (16:05:18, 16 December 2024)
- ML20069D075 + (16:05:18, 16 December 2024)
- 05000395/LER-1983-012-03, /03L-0:on 830210,flow Indicator for Steam Generator a Feedwater Flow FI-477 Failed Low.Caused by Failure of Power Supply FQY-477.Circuit Board Replaced + (16:05:20, 16 December 2024)
- ST-HL-AE-4798, Responds to NRC Re Violation Noted in Insp Rept 50-498/94-09 Re Separation Betweeen Scaffolding & Equipment. Corrective Actions:Scaffold Cross Member Touching Essential Cooling Water Pump 1A Discharge Piping Adjusted + (16:05:21, 16 December 2024)
- ML20069D057 + (16:05:22, 16 December 2024)
- 05000395/LER-1983-012, Forwards LER 83-012/03L-0.Detailed Event Analysis Encl + (16:05:23, 16 December 2024)
- ML20069D055 + (16:05:23, 16 December 2024)
- ML20069D053 + (16:05:24, 16 December 2024)
- ML20069D049 + (16:05:25, 16 December 2024)
- 05000395/LER-1983-013-03, /03L-0:on 830113 & 19,condensate Storage Tank Level Transmitters LT-3631 & LT-3631A Failed Due to Frozen Instrument Lines.Caused by Temp Sensing Element Not Being Located Per Design Specs.Element Relocated + (16:05:26, 16 December 2024)
- ML20069D042 + (16:05:27, 16 December 2024)
- 05000324/LER-1983-021-03, /03L-0:on 830301,HPCI Sys Declared Inoperable When Instrument 2E41-dPIS-N005 Showed Negative Indication While Redundant Instrument 2E41-dPIS-N004 Indicated Zero.Caused by Instrument drift.N005 Calibr & Returned to Svc + (16:05:29, 16 December 2024)
- NRC-94-4114, Forwards Prorpietary & Nonproprietary Addl Info in Support of Westinghouse Response to RAI 952.44-952-46.Proprietary Info Withheld (Ref 10CFR9.17(a)(4)) + (16:05:30, 16 December 2024)
- 05000395/LER-1983-013, Forwards LER 83-013/03L-0.Detailed Event Analysis Encl + (16:05:31, 16 December 2024)
- ML20069D026 + (16:05:32, 16 December 2024)
- ML20069D017 + (16:05:33, 16 December 2024)
- ML20069D014 + (16:05:33, 16 December 2024)
- ML20069D013 + (16:05:34, 16 December 2024)
- ML20069D009 + (16:05:35, 16 December 2024)
- ML20069D008 + (16:05:35, 16 December 2024)
- ML20069D007 + (16:05:36, 16 December 2024)
- ML20069D002 + (16:05:37, 16 December 2024)
- ML20069D005 + (16:05:37, 16 December 2024)
- ML20069C997 + (16:05:38, 16 December 2024)
- ML20069C982 + (16:05:38, 16 December 2024)
- ML20069C931 + (16:05:47, 16 December 2024)
- ML20069C948 + (16:05:47, 16 December 2024)
- ML20069C922 + (16:05:49, 16 December 2024)
- ML20069C920 + (16:05:49, 16 December 2024)
- ML20069C914 + (16:05:50, 16 December 2024)
- 05000324/LER-1983-021, Forwards LER 83-021/03L-0 + (16:05:51, 16 December 2024)
- ML20069C910 + (16:05:51, 16 December 2024)
- ML20069C902 + (16:05:53, 16 December 2024)
- 05000302/LER-1983-008-03, /03L-0:on 830211,absolute Position Indication for Rod 1,group 1,failed to Indicate +/- 2% Motion.Caused by Failed Reed Switch.Rod Position Verified Via Zone Ref. Position Indicator Tube Containing Faulty Switch Replaced + (16:05:55, 16 December 2024)
- ML20069C899 + (16:05:56, 16 December 2024)
- 05000456/LER-1994-009-02, :on 940425,unexpected Reactor Trip Actuation Occurred Due to Procedural Deficiency W/Procedure Bwop RP-7. Procedure Bwop RP-7 Revised to Identify Fact That Reactor Trip Function Not Disabled by Procedure + (16:05:58, 16 December 2024)
- 05000302/LER-1983-008, Forwards LER 83-008/03L-0 + (16:05:59, 16 December 2024)