- ML20080F308 + (03:15:24, 15 December 2024)
- ML20080F310 + (03:15:24, 15 December 2024)
- 05000271/LER-1983-018-03, /03L-0:on 830809,HPCI Sys Declared Inoperable After Tripping & Resetting Occurred During Vibration Test. Caused by Normal Vibration Loosening Set Screw Holding Piston in Position on Ball & Tappet Holder + (03:15:29, 15 December 2024)
- 05000374/LER-1994-010-08, :on 941214,division 2 ECC & RCIC Initiated Due to Ps Isolation Valve Leak.Action Request Was Initiated to Repair Isolation Valve + (03:15:31, 15 December 2024)
- AECM-83-0561, Part 21 Rept 2 Re Improperly Assembled Automatic Switch Co Spare Part Kits for Scram Pilot Valve Solenoids.Initially Reported on 830804.Investigation Continuing.Final Rept Will Be Provided by 840224 + (03:15:32, 15 December 2024)
- ML20080F298 + (03:15:33, 15 December 2024)
- ML20080F293 + (03:15:34, 15 December 2024)
- ML20080F296 + (03:15:34, 15 December 2024)
- 05000311/LER-1983-041-03, /03L-0:on 830801 & 09,spurious Actuations of Safeguards Equipment Control Sys Channel a Caused Deenergization of Vital Bus 2A.Possibly Caused by near-short Condition on Output Test Panel Terminals + (03:15:36, 15 December 2024)
- 05000321/LER-1983-074-03, /03L-0:on 830815 & 18,filter & Demineralizer Conductivity Recorder 1G31-R601 Indicated Different Value than Tech Specs.Caused by Inoperative & Uncalibr Conductivity Meter,Respectively.Meter Calibr + (03:15:41, 15 December 2024)
- 05000311/LER-1983-042-03, /03L-0:on 830802 & 11,control Rod Position Indicator Channel Indicated Greater than 12 Steps Difference as Compared to Group Demand Indication.Caused by Indicator Reading Low & Signal Conditioner Module Drift + (03:15:43, 15 December 2024)
- 05000281/LER-1983-034-03, /03L-0:on 830813,w/unit at Constant Speed Drive, Periodic Snubber Functional Testing Revealed 23 Snubbers Failed to Meet Required Acceptance Criteria.Caused by Seal Degradation & Scored Piston/Body + (03:15:45, 15 December 2024)
- 05000321/LER-1983-075-03, /03L-0:on 830816,reactor Water Cleanup Sys Differential Flow Transmitter 1G31-NO36 Discovered Out of Calibr.Caused by Setpoint Drift.Transmitter Calibr + (03:15:47, 15 December 2024)
- 05000311/LER-1983-043-03, /03L-0:on 830802 & 07,reactor Coolant Flow Channel I,Number 24 Indicated Excessively High.Caused by Static Shift in Transmitter & Failure of Transmitter Oscillator, Respectively.Transmitter Readjusted + (03:15:49, 15 December 2024)
- ML20080F267 + (03:15:50, 15 December 2024)
- 05000387/LER-1983-114-03, /03L-0:on 830809,at 100% Power,After Preventive Maint,Standby Gas Treatment Sys Train a Started & Fan Tripped on Low Heater Differential Temp.Caused by Maint Directions Supplying Air Flow Signal W/O Flow + (03:15:52, 15 December 2024)
- 05000498/LER-1994-020, :on 941209,determination Made That Combined Total of 66 Breakers Potentially Out of Tolerance.Caused by Misinterpretation of Acceptance Criteria.Molded Case Circuit Breaker Tests Procedure Revised + (03:15:54, 15 December 2024)
- 05000416/LER-1983-150-99, Limiting Condition for Operation Entered When Five fire-rated Floor Penetrations in Auxiliary Bldg Opened to Route Cable.Caused by Issuing Design Change Package 82-4145 + (03:15:56, 15 December 2024)
- ML20080F258 + (03:15:57, 15 December 2024)
- 05000387/LER-1983-110-03, /03L-0:on 830818,wick for Chlorine Detector a (XISH-07802A) in Control Structure Ventilation Sys Discovered Not Dripping Electrolyte Fluid as Required.Caused by Clogged Wick.New O-rings Will Be Installed + (03:15:59, 15 December 2024)
- 05000341/LER-1994-011, :on 941123,erratic Indication Observed for Intermediate Range Monitor E During Testing of SRM C. Caused by Personnel Low Sensitivity of Significance.Screws Replaced & Tightened as Necessary + (03:16:01, 15 December 2024)
- AECM-83-0571, RO 83-080/0:on 830806,fire-rated Door 1A317 Blocked Open to Support Planned Maint Activities.Fire Watches Established Until Door Restored on 830831 + (03:16:02, 15 December 2024)
- ML20080F250 + (03:16:03, 15 December 2024)
- ML20080F245 + (03:16:04, 15 December 2024)
- ML20080F246 + (03:16:04, 15 December 2024)
- ML20080F244 + (03:16:05, 15 December 2024)
- B10885, Final Deficiency Rept SD-36 Re Design & Const of Main Control Board Welds.Initially Reported on 830513.Welds Repaired & Approved by S&W & Reliance.Welds Analyzed by Reliance & Approved by S&W + (03:16:08, 15 December 2024)
- ML20080F241 + (03:16:08, 15 December 2024)
- ML20080F236 + (03:16:11, 15 December 2024)
- ML20080F237 + (03:16:11, 15 December 2024)
- 05000373/LER-1994-015-04, :on 941212,Group 1 MSIV Pci Occurred,Causing Reactor Scram.Caused by Failed Switch.Switch Replaced.W/ + (03:16:19, 15 December 2024)
- ML20080F200 + (03:16:20, 15 December 2024)
- ML20080F198 + (03:16:21, 15 December 2024)
- ML20080F194 + (03:16:22, 15 December 2024)
- ML20080F189 + (03:16:25, 15 December 2024)
- TAC:52013 + (03:16:28, 15 December 2024)
- ML20080F186 + (03:16:30, 15 December 2024)
- ML20080F176 + (03:16:31, 15 December 2024)
- ML20080F175 + (03:16:32, 15 December 2024)
- 05000333/LER-1983-026-03, /03L-0:on 830819,during Special Insp of Main Steam Line Pipe Supports & Restraints Outboard of Containment Msiv,Support Frame Above Trunnion H29-351 Found Bent.Caused by Insufficient Design Clearance + (03:16:33, 15 December 2024)
- JAFP-83-0884, Responds to IE Bulletin 83-03, Check Valve Failures in Raw Water Cooling Sys of Diesel Generators. Emergency Svc Water Pump Discharge Check Valves ESW 1A Had Corroded Threaded Stud.Stud Will Be Replaced + (03:16:35, 15 December 2024)
- ML20080F165 + (03:16:35, 15 December 2024)
- TAC:43020 + (03:16:36, 15 December 2024)
- ML20080F152 + (03:16:37, 15 December 2024)
- ML20080F147 + (03:16:41, 15 December 2024)
- 05000416/LER-1983-082-01, During 18-month Testing, Starting Air Valve for Right Cylinder 8 & Left Bank Cylinder 1 Failed.Caused by Contamination of Atmospheric Vent Lines & Malfunctions of Air Distributor + (03:16:42, 15 December 2024)
- ML20080F144 + (03:16:44, 15 December 2024)
- 05000416/LER-1983-076-03, Two of Four Channels for Containment & Drywell Ventilation Exhaust Radiation Monitor Failed Monthly Surveillance.Caused by Too Restrictive Requirement + (03:16:45, 15 December 2024)
- 05000366/LER-1983-089-03, /03L-0:on 830819,during Consip Delphi Model K-1V Hydrogen & Oxygen Analyzer Ft&C Procedure HNP-2-3882, Analyzers 2P33-POO1A & 2P33-P001B Determined to Be Out of Calibr.Caused by Stuck Diaphragms + (03:16:51, 15 December 2024)
- ML20080F136 + (03:16:52, 15 December 2024)
- U-602384, Response to NRC Re Certain RP & Physical Security Incidents at Plant.Informs That Although Some Incidents Did Occur,No Intent Made to Prevent Employees from Recording Actual Dose + (03:16:53, 15 December 2024)
- RC-95-0009, Comment Supporting Proposed Rule 10CFR21 Re inter-utility Transfer + (03:16:53, 15 December 2024)