- ML20086R951 + (06:33:17, 14 December 2024)
- 05000280/LER-1977-007-03, /03L:on 770215,safety Valve SV-MS-101A Lifted Prematurely at Approx 950 Psi,Below Normal Setpoint of 1,085 Psi.Caused by Torque Limiting Device Setting Low Causing Drift.Safety Valves Reset + (06:33:19, 14 December 2024)
- 05000280/LER-1977-008-03, /03L:on 770220,when Recirculation Halted to Replace Leaking Diaphragm in Valves 1-CH-98,150 Mwe/H Rampdown Initiated.Draphragm Failure Caused by Valve Overtightening When Shutting + (06:33:21, 14 December 2024)
- LD-84-009, Forwards Interface Requirements Re Block Valves on Atmospheric Dump Valves to Close Out Confirmatory Item 2 of Sser 2 Re Steam Generator Tube Rupture Analysis + (06:33:22, 14 December 2024)
- ML20086R941 + (06:33:23, 14 December 2024)
- 05000280/LER-1977-009-03, /03L:on 770219,chemical Addition Tank Discharge Valve MOV-CS-102A Position Indicating Lights Extinguished. Caused by Incorrectly Wired Switch.Maint Procedure Revised + (06:33:24, 14 December 2024)
- ML20086R935 + (06:33:25, 14 December 2024)
- ML20086R934 + (06:33:26, 14 December 2024)
- NRC-84-0037, Advises of Design Changes Instituted as Result of NRC Fire Protection Review.Addl Sprinkler Heads Will Be Installed in Auxiliary Bldg West Corridors at 2,000 Ft & 1,974 Ft Elevations + (06:33:27, 14 December 2024)
- ML20086R923 + (06:33:27, 14 December 2024)
- 05000280/LER-1977-010-03, /03L:on 770328,high Steam Flow Relay FC-485-XA Malfunctioned.Caused by Foreign Matl Impregnating Bf Relay. Debris Removed + (06:33:29, 14 December 2024)
- ML20086R914 + (06:33:30, 14 December 2024)
- ML20086R911 + (06:33:30, 14 December 2024)
- ML20086R908 + (06:33:31, 14 December 2024)
- 05000281/LER-1977-001-03, /03L:on 770118,recirculation Flow from Boric Acid Tank B Ceased.Caused by Broken Coupling Between Motor & Pump on Transfer Pump 1-CH-P-20.Coupling Repaired + (06:33:33, 14 December 2024)
- ML20086R903 + (06:33:34, 14 December 2024)
- ML20086R897 + (06:33:35, 14 December 2024)
- ML20086R899 + (06:33:35, 14 December 2024)
- 05000458/LER-1995-005-02, :on 950627,HPCS Pump Breaker Tripped During Surveillance Testing.Cause of Failure Not Identified.Breaker Internals,Prop Springs & Closing Latch Spring Inspected.W/ + (06:33:38, 14 December 2024)
- 05000259/LER-1995-001-04, :on 950629,EECW Pump Auto Started During Performance of SI as Result of Jumpering Wrong Relay Contacts Due to Personnel Error.Field Wiring for EECW Pump B1 Modified + (06:33:40, 14 December 2024)
- 05000281/LER-1977-002-03, /03L:on 770126,ability to Maintain Recirculation Between Boric Acid Tank & Boron Injection Tank Lost.Caused by Obstruction in Line from Tank C to Transfer Pumps. Line Back Flushed + (06:33:42, 14 December 2024)
- ML20086R882 + (06:33:43, 14 December 2024)
- TXX-9145, Responds to NRC Re Violations Noted in Insp Rept 50-445/91-56 on 911028-1101.Corrective Actions:Review of Preservice Insp Data Continues to Be Performed & Exams Performed in Second Direction on Reactor Vessel Nuts + (06:33:44, 14 December 2024)
- ML20086R869 + (06:33:44, 14 December 2024)
- ML20086R867 + (06:33:45, 14 December 2024)
- 05000281/LER-1977-003-03, /03L:on 770209,loop C Cold Protection Channel T-432 Failed.Caused by Malfunction of Span Potentiometer in Low Level Amplifier TM-2-432.Amplifier Replaced W/Shop Spare + (06:33:47, 14 December 2024)
- ML20086R863 + (06:33:48, 14 December 2024)
- ML20086R864 + (06:33:48, 14 December 2024)
- ML20086R862 + (06:33:49, 14 December 2024)
- 05000354/LER-1995-013, :on 950627,discovered Condidtion Prohibited by TS Due to Missed Surveillance in Accordance W/Requirements of TS 4.0.5.Surveillance Considered Overdue as of 950427. Surveillance Scheduling Sys Updated + (06:33:51, 14 December 2024)
- 05000333/LER-1983-060-03, Incorrect Motor Actuator Installed on RHR Suppression Pool Outboard Isolation Valve During Maint Activities.Cause Not Stated.Replacement Actuator Installed on 840119 + (06:33:54, 14 December 2024)
- ML20086R856 + (06:33:55, 14 December 2024)
- ML20086R855 + (06:33:56, 14 December 2024)
- ML20086R851 + (06:33:57, 14 December 2024)
- A03616, Submits Info Re NUREG-0737,Items II.E.1.2, Safety Grade Auxiliary Feedwater Sys Initiation & Flow Indication & II.K.3.3, Reporting of Safety & Relief Valve Failures & Challenges, Per Util & Generic Ltr 82-16 + (06:33:59, 14 December 2024)
- ML20086R847 + (06:33:59, 14 December 2024)
- 05000306/LER-1995-003-02, :on 950626,unplanned auto-start of AFW Pump Occurred Due to Faulty Adjustment of Curcuit Breaker Cell Switch.Mechanical Linkage to Cell Switch in Question Adjusted & Visual Checks Made of Contact Wipe + (06:34:02, 14 December 2024)
- ML20086R839 + (06:34:03, 14 December 2024)
- ML20086R838 + (06:34:04, 14 December 2024)
- ML20086R837 + (06:34:04, 14 December 2024)
- RBG-17-089, Interim Deficiency Rept DR-134 Re Four Lines Located at Outlet of Each RHR Sys HX Shell.Investigation Incomplete. Next Status Rept Will Be Submitted by 840425 + (06:34:05, 14 December 2024)
- ML20086R834 + (06:34:07, 14 December 2024)
- ML20086R829 + (06:34:15, 14 December 2024)
- ML20086R825 + (06:34:16, 14 December 2024)
- 05000458/LER-1995-006-02, :on 950627,identified Electrical Containment Penetration Overcurrent Protection Device Not Adequately Tested Due to Inadequate Development & Implementation of Historic Mod request.ENG-3-033 Revised + (06:34:19, 14 December 2024)
- ML20086R822 + (06:34:21, 14 December 2024)
- ML20086R823 + (06:34:21, 14 December 2024)
- 05000423/LER-1995-013-01, :on 950628,determined That an IST Surveillance Had Lapsed on C Charging Sys Pump & Discharge Check Valve. Caused by Inadequate Procedures.Surveillances Performed & Procedures Revised + (06:34:24, 14 December 2024)
- 0CAN079504, Forwards Summary of Items That Require Rev or Will No Longer Be Implemented Due to Alternate Controls.Submittal Contains No New Commitments + (06:34:28, 14 December 2024)
- NRC-84-0036, Provides Data Supporting Preservice Insp Relief Request Re Random Component & Piping Welds,Per Util .Listed Welds Require Partial Relief from Section XI Volumetric Exam Requirements + (06:34:29, 14 December 2024)
- ML20086R806 + (06:34:30, 14 December 2024)