Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ST-HL-AE-1130, Interim Deficiency Rept Re Containment Spray Ph.Initially Reported on 840821.Corrective Actions to Be Discussed in Final Rept.Next Rept Anticipated by 850111 + (15:41:36, 13 December 2024)
- ML20093C173 + (15:41:40, 13 December 2024)
- ML20093C172 + (15:41:41, 13 December 2024)
- 05000327/LER-1984-051, :on 840911,following Addl Insps of Various safety-related Sys,Fire Watches Established in Compliance W/ App R of 10CFR50.Watch Will Remain in Effect Until Full Compliance Achieved + (15:41:42, 13 December 2024)
- ML20093C164 + (15:41:43, 13 December 2024)
- ML20093C152 + (15:41:44, 13 December 2024)
- ML20093C135 + (15:41:47, 13 December 2024)
- 05000315/LER-1984-021-01, :on 840829,discovered Calibr Constants for Eberline Radiation Monitoring Sys Calculated Incorrectly for Secondary Source.Caused by Error in Procedure.Procedure Changed & Calibr Constants Corrected + (15:41:49, 13 December 2024)
- ML20093C128 + (15:41:50, 13 December 2024)
- 05000275/LER-1984-025, :on 840826,containment Purge Sys Noble Gas Activity Monitors RM-14A & 14-B Inoperable.Caused by Personnel Blocking Containment Isolation Signal from Monitor 14-B While Removing 14-A from Svc for Mod + (15:41:51, 13 December 2024)
- ML20093C116 + (15:41:53, 13 December 2024)
- ML20093C110 + (15:41:54, 13 December 2024)
- ML20093C108 + (15:41:55, 13 December 2024)
- 05000348/LER-1984-018, :on 840211,RHR Sys Trains a & B Made Inoperable.Caused by Sys Being Placed in Recirculation Mode. Both Trains Returned to Normal Lineup + (15:41:57, 13 December 2024)
- ML20093C105 + (15:41:58, 13 December 2024)
- ML20093C104 + (15:42:00, 13 December 2024)
- ML20093C101 + (15:42:02, 13 December 2024)
- ML20093C095 + (15:42:03, 13 December 2024)
- ML20093C099 + (15:42:03, 13 December 2024)
- 05000397/LER-1984-095, :on 840910,during Power Ascension Test,Reactor Scram Occurred.Caused by Test Switch Connected to Reactor Protection Sys Rather than Reactor Pump Trip Logic,Due to Misreading of Test Procedure Drawing + (15:42:05, 13 December 2024)
- ML20093C089 + (15:42:06, 13 December 2024)
- ML20093C085 + (15:42:07, 13 December 2024)
- ML20093C082 + (15:42:08, 13 December 2024)
- ML20093C081 + (15:42:09, 13 December 2024)
- ML20093C080 + (15:42:10, 13 December 2024)
- ML20093C079 + (15:42:11, 13 December 2024)
- RBG-19048, Interim Deficiency Rept DR-240 Re Three Potential Problems W/Random Trip Output of Westinghouse Type SA-1 Differential Relays.Initially Reported on 840828.Interim or Final Status Rept Will Be Provided by 841027 + (15:42:12, 13 December 2024)
- ML20093C073 + (15:42:14, 13 December 2024)
- 05000335/LER-1984-008-02, :on 840828,spurious Containment Isolation Signal Received.Caused by Two Shorted Instrument Bus Wires During Electrical Insp.Signal Reset + (15:42:16, 13 December 2024)
- ML20093C068 + (15:42:17, 13 December 2024)
- ML20093C062 + (15:42:18, 13 December 2024)
- ML20093C057 + (15:42:19, 13 December 2024)
- TAC:43804 + (15:42:20, 13 December 2024)
- ML20093C056 + (15:42:21, 13 December 2024)
- 05000370/LER-1984-019-01, :on 840820,while Filling & Venting Upper Head Injection Sys,Reactor Vessel Head Sight Glass Failed, Releasing RCS Water Into Containment Bldg.Caused by Design Deficiency.Sight Glass Replaced + (15:42:23, 13 December 2024)
- ML20093C044 + (15:42:24, 13 December 2024)
- W3P84-2580, Interim Rept of Significant Const Deficiency 84 Re Tube Track Welding Defects.Rept Reopened to Resolve Issues Referenced in DG Eisenhut .Final Rept Due Approx 841005 + (15:42:24, 13 December 2024)
- ML20093C043 + (15:42:25, 13 December 2024)
- W3P84-2582, Interim Rept of Significant Const Deficiency 101 Re Traceability of Stainless Steel Instrument Tubing.Rept Reopened to Resolve Issues Referenced in DG Eisenhut .Final Rept Due Approx 841005 + (15:42:25, 13 December 2024)
- ML20093C038 + (15:42:26, 13 December 2024)
- 05000397/LER-1984-096, :on 840901,deluge Sys Actuated Due to Steam Leak.Fire Pump & Two pre-action Sys Tripped & Fire Alarm Received for Water Filtration Bldg.Caused by Shut Cooling Water Supply Valve to FP-P-110 Diesel Engine + (15:42:30, 13 December 2024)
- ML20093C030 + (15:42:32, 13 December 2024)
- 05000331/LER-1984-033, :on 840906,electric Fire Pump Failed to Meet Flow Requirements & Plant Exceeded 7-day Limit for Pump Inoperability.Pump Impeller Adjusted to Increase Flow to Meet Requirement + (15:42:34, 13 December 2024)
- ML20093C026 + (15:42:35, 13 December 2024)
- ML20093C025 + (15:42:36, 13 December 2024)
- W3P84-2583, Interim Rept of Significant Const Deficiency 57 Re Inadequate Instrumentation & Control Installations Turnover Documentation.Rept Reopened to Resolve Issues Referenced in DG Eisenhut .Final Rept Due Approx 841005 + (15:42:36, 13 December 2024)
- 05000338/LER-1984-008-02, :on 840901,radial Flaws Discovered During Insp of HX Lap Rings.Caused by Cracking Due to Chloride Induced Stress Corrosion.Stainless Steel Installed at Point of Lap Ring + (15:42:38, 13 December 2024)
- ML20093C012 + (15:42:42, 13 December 2024)
- ML20093C017 + (15:42:42, 13 December 2024)
- ML20093C006 + (15:42:44, 13 December 2024)
- 3F0884-19, Effluent & Waste Disposal Semiannual Rept,Jan-June 1984 + (15:42:45, 13 December 2024)