- ML20100N886 + (10:28:37, 13 December 2024)
- ML20100N889 + (10:28:37, 13 December 2024)
- ML20100N884 + (10:28:38, 13 December 2024)
- ML20100N882 + (10:28:39, 13 December 2024)
- ML20100N876 + (10:28:40, 13 December 2024)
- 05000416/LER-1984-051, :on 841102 & 03,two RCIC Isolations Occurred Due to High Flow on RCIC Steam Line.Caused by Water Collected in Elbow Top Loop Seals for Steam Flow Transmitter.Pressure Equalized + (10:28:41, 13 December 2024)
- ML20100N871 + (10:28:42, 13 December 2024)
- ML20100N865 + (10:28:43, 13 December 2024)
- ML20100N862 + (10:28:44, 13 December 2024)
- ML20100N858 + (10:28:45, 13 December 2024)
- ML20100N854 + (10:28:46, 13 December 2024)
- 05000331/LER-1984-040, :on 841104,auxiliary Transformer Failed,Causing Main Generator & Auxiliary Transformer Breakers to Nonessential Buses to Open.Caused by Short Circuit Between Turns in High Voltage Winding of Phase Coil + (10:28:47, 13 December 2024)
- ML20100N849 + (10:28:48, 13 December 2024)
- ML20100N845 + (10:28:49, 13 December 2024)
- 05000454/LER-1984-001-08, :on 841104,hourly Fire Watch Patrol Not Executed in Areas W/Degraded Fire Barriers.Addl Instruction Re Staffing for Fire Watches Provided to Security Supervisors + (10:28:50, 13 December 2024)
- ML20100N832 + (10:28:51, 13 December 2024)
- ML20100N829 + (10:28:52, 13 December 2024)
- ML20100N827 + (10:28:53, 13 December 2024)
- 05000247/LER-1984-021, :on 841002,during Surveillance Test of Svc Water Pumps,Back Leakage Across Check Valves on Discharge Side of Two Pumps Observed.Affected Check Valves Repaired & Tested Satisfactorily + (10:28:54, 13 December 2024)
- ML20100N810 + (10:28:56, 13 December 2024)
- ML20100N815 + (10:28:56, 13 December 2024)
- ML20100N808 + (10:28:57, 13 December 2024)
- ML20100N793 + (10:28:58, 13 December 2024)
- ML20100N790 + (10:28:59, 13 December 2024)
- ML20100N767 + (10:28:59, 13 December 2024)
- BSEP-84-2460, Forwards Monthly Operating Repts for Oct 1984.Gross Thermal Energy Generator Incorrect Due to Apparent Software Problem. Corrected Rept Will Be Forwarded Upon Resolution.Error Does Not Affect Other Rept Parameters + (10:29:00, 13 December 2024)
- ML20100N746 + (10:29:01, 13 December 2024)
- U-602559, Comments on Proposed Rule 10CFR20 Re Unauthorized Use of Licensed Radioactive Matl.Proposes Changes to Wording of Pr + (10:29:02, 13 December 2024)
- ML20100N742 + (10:29:04, 13 December 2024)
- 05000454/LER-1984-003-08, :on 841107,during Initial Core Loading,Signal Spiking Seen on Both Source Range Channels.Source Range Channels Declared Inoperable.Caused by Electrical Noise on Sys or Induced Onto Sys.Fix Being Investigated + (10:29:06, 13 December 2024)
- ML20100N708 + (10:29:07, 13 December 2024)
- ML20100N705 + (10:29:08, 13 December 2024)
- ML20100N701 + (10:29:09, 13 December 2024)
- ML20100N703 + (10:29:09, 13 December 2024)
- ML20100N694 + (10:29:10, 13 December 2024)
- ML20100N696 + (10:29:10, 13 December 2024)
- ML20100N692 + (10:29:11, 13 December 2024)
- ML20100N689 + (10:29:12, 13 December 2024)
- ML20100N684 + (10:29:13, 13 December 2024)
- ML20100N687 + (10:29:13, 13 December 2024)
- ML20100N683 + (10:29:14, 13 December 2024)
- ML20100N680 + (10:29:15, 13 December 2024)
- ML20100N677 + (10:29:16, 13 December 2024)
- ML20100N673 + (10:29:16, 13 December 2024)
- ML20100N671 + (10:29:17, 13 December 2024)
- ML20100N669 + (10:29:18, 13 December 2024)
- ML20100N664 + (10:29:19, 13 December 2024)
- ML20100N665 + (10:29:19, 13 December 2024)
- ML20100N662 + (10:29:20, 13 December 2024)
- ML20100N659 + (10:29:21, 13 December 2024)
- ML20100N657 + (10:29:21, 13 December 2024)