Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML17058A955 +
- ML17058A956 +
- NRC Generic Letter 1991-07 +
- ML18095A907 +
- NRC Generic Letter 91-07, GI-23, "Reactor Coolant Pump Seal Failures" and Its Possible Effect on Station Blackout +
- ML20024H137 +
- ML20077C654 +
- ML20077A485 +
- ML20073Q065 +
- ML20073M937 +
- ML20073J025 +
- ML20073H861 +
- ML20073H652 +
- ML20073H468 +
- ML20073H416 +
- ML20073H391 +
- ML20073H274 +
- ML20091A717 +
- ML20091A363 +
- PNO-IV-91-013, on 910502,secretary of Licensee Security Manager Inadvertently Admitted Loaded Derringer Into Protected Area as She Entered Site on 910502.Employee Later Remembered Weapon in Purse & Reported Event to Security +
- ML20266E308 +
- ML20262D596 +
- 3F0591-01, Submits Addl Info Re 900406 Tech Spec Change Request 181 Covering once-through Steam Generator Tube Sleeving,Per NRC 910104 Request.Qualification Performed for Alloy 690 Patterned After Alloy 600 Sleeve Qualification +
- RBG-34939, Forwards EA-PT-91-0003-M, River Bend Station Plant Transient Analysis Methodology, for Review & Approval +
- RBG-34-927, Corrects Typos in 910411 Application for Amend to License NPF-47,changing Tech Specs 4.0.5,3.4.3.1 & 3.4.3.2 Per Generic Ltr 88-01 Re Inservice Insp of Piping Susceptible to IGSCC +
- ML20206S861 +
- ML20199A750 +
- 05000324/LER-1991-002-03, :on 910402,IRM D Spiked Upscale During Dc Ground Isolation Procedures Causing Full RPS Trip.Rps Trip Reset After Circuit Breaker Closed,Metal Oxide Varistors Installed & Adverse Condition Rept Issued +
- 05000328/LER-1991-002, :on 910211,required Fire Watch Not Established During Maint Svc to Fire Protection Panel O-L-630 Due to Weaknesses in Methods for Removing Fire Protection equipment.PHYSI-13 Procedure Will Be Revised +
- 05000440/LER-1991-010, :on 910401,failure of Reactor Recirculation Pump Resulted in Shutdown of Plant.Caused by Component Malfunction.Contractor Replaced & Recirculation Pump Verified to Operate Properly in Low Speed +
- 05000364/LER-1991-002, :on 910409,reactor Manually Tripped Following Loss of Operating Steam Generator Feedwater Pump.Caused by Failed Eh Fluid Supply Line Coupling & Loss of Eh Fluid.Eh Tubing Repaired +
- ML20024H346 +
- ML20073J869 +
- ML20024H039 +
- ML18095A916 +
- ML18057A887 +
- ML18009A896 +
- L-91-125, Responds to NRC Ltr Re Weaknesses Identified in Insp Rept 50-250/OL-91-01.Corrective Actions:Epip 20101, Duties of Emergency Coordinator, Will Be Revised to Further Clarify Desired Emergency Classification for Specific Scenario +
- L-91-108, Responds to NRC 900919 Request for Addl Info Re Util Rept, NTH-TR-01, Retran Model Clarification - Decrease in Heat Removal by Secondary Sys +
- ML17305B529 +
- IR 05000244/1991008 +
- ML16259A260 +
- ML14184A826 +
- ML14184A828 +
- ML16148B002 +
- ML17223B180 +
- ML17305B525 +
- ML17329A015 +
- ML18095A918 +
- TAC:73102 +