Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML17334B364 +
- ML17328A661 +
- ML17328A660 +
- ML18033B252 +
- ML18033B251 +
- ML18033B250 +
- ML20012F680 +
- ML18095A447 +
- ML18095A444 +
- ML18054B553 +
- ML18054B552 +
- ML18054B551 +
- 05000280/LER-1990-001-03, :on 900314,emergency Svc Water Pumps Declared Inoperable Due to Emergency Shutdown Device Being in Tripped Condition.Caused by Procedural & Training Deficiencies. Procedures Changed & Training Enhanced +
- ML111660968 +
- ML111660969 +
- ML20043H043 +
- ML20042E449 +
- ML20042E374 +
- ML20042E193 +
- ML20059C923 +
- PNO-III-90-028, on 900410,dye Penetrant Testing on Inside of Reactor Vessel Head Identified 23 Cracks of Various Dimensions.Licensee Begun Repairing Cracks by Grinding Cracked Areas +
- ML20062B765 +
- ML20058B863 +
- ML20199A684 +
- IR 05000443/1990002 +
- ML20042E077 +
- PNO-I-90-027, on 900410,potential for Unauthorized Individuals Being Granted Unescorted Access at Plant identified.Twenty-two Contractor Employees Denied Access to Protected & Vital Areas Due to Audit +
- 05000424/LER-1990-005, :on 900314,observed That Indicator Lights for Actuation Handswitches for Trains a & B of Fuel Handling Bldg Showed Actuation Occurred.Caused by Personnel Error. Operator Counseled +
- 05000395/LER-1990-002, :on 900318,inadvertent ESF Actuation Occurred When Emergency Start Signal Reset.Caused by Procedure Inadequacy When Emergency Start Signal Still Present on Train B.Sys Operating Procedure Revised +
- ML20042E305 +
- ML20042E406 +
- ML20042E485 +
- ML20034C541 +
- IR 05000293/1990008 +
- 05000354/LER-1990-003-02, :on 900319,reactor Scram Occurred on Low Reactor Level When All Feedwater Pumps Tripped in Response to Loss of Primary & Secondary Condensate Pumps.Caused by Offsite Marsh Fire.Incident Reviewed +
- IR 05000333/1990001 +
- PNO-III-90-027, on 900410,glass Syringe Vial Containing 1 Mci P-32 Reported Missing.Lead Pig Was Wipe Tested on 900406 & Returned to Original Shipping Package.Search Being Conducted.Region III Monitoring Search.State Notified +
- ML20034B330 +
- 05000324/LER-1990-003-03, :on 900312,closure of Main Steam Line Isolation Valves Occurred.Caused by Failure to Reset Half Scram Signal on Channel a Prior to Continuing Test on Channel B of Associated Instrumentation +
- ML20034A341 +
- 2CAN049009, Informs of Change to SAR & NUREG-0737,Item II.E.4.1 Submittal Re Hydrogen Purge Sys +
- ST-HL-AE-3414, Responds to Request for Addl Info Re Plant Probabilistic Safety Assessment Fire Analysis.Class 1,2 & 3 Scenerios Were Subjected to Initial Quantitative Screening Per Applicable Guidelines +
- ML20034A025 +
- 05000304/LER-1990-004-05, :on 900312,monthly Performance Test PT-7 Not Performed on Auxiliary Feedwater Pumps 2B & 2C Prior to Critical Date.Caused by Personnel Error.Pump Operability to Be Verified Prior to Startup from Outage +
- 05000445/LER-1990-004, :on 900312,ESF Actuation Occurred,Resulting in Initiation of Train a Safety Injection W/Flow to Rcs.Caused by Failed Diode on Safeguards Driver Board.Station Procedures Revised +
- 05000254/LER-1990-006-01, :on 900313,tornado Warning for Rock Island County Received on Weather Radio.Station Entered Procedure Qoa 010-10.One Person Substained Minor Injuries & Some Site Damage Sustained.Notification to Be Evaluated +
- 05000324/LER-1990-004-02, :on 900313,manual Reactor Scram Initiated Due to Failure of Safety/Relief Valve to Close During Startup Testing.Caused by Failure of Solenoid Valve.Valve Replaced +
- ML20034A056 +
- ML20033H101 +
- ML20042F878 +