- ENS 48463 +
- ML17328A885 +
- ML093080466 +
- ML20082S913 +
- ML20151Z380 +
- ML20206E459 +
- ML20066D322 +
- ML20237K398 +
- ML20247A129 +
- ML20217E114 +
- ML20215D326 +
- ML20210H976 +
- ML20210H959 +
- 05000220/LER-2021-002, Isolation of Both Emergency Condensers Due to Loss of UPS 162A +
- 05000458/LER-2020-002, Manual Reactor Scram Due to Reactor Recirculation Pump Trip +
- 05000498/LER-1989-012-01, :on 890506,operation of Control Room Ventilation Sys in Violation of Tech Specs.Caused by Operator Error.Personnel Counseled & Training Initiated.W/ +
- 05000373/LER-1986-027, :on 860628 & 29,control Room B HVAC Sys Ammonia Detector OXY-VC165YA Spuriously Tripped.Caused by Warped Rubber Capstan Roller.Roller Replaced +
- 05000259/LER-1988-020-02, :on 880623,ESF Inadvertently auto-started. Caused by Personnel Error & Procedural Inadequacy.Diesel Generator D Logic Opened & Personnel Counseled +
- 05000338/LER-1988-001, :on 880103,vent Stack a Normal Range Radiation Monitor Declared Inoperable Due to High Indicated Radiation Levels.Caused by Scintillator Tube Shorting to Detector Housing.Scintillator Tube Replaced +
- IR 05000346/1985023 +
- 05000311/LER-1985-008, :on 850502,reactor Trip Occurred.Caused by Main Generator Loss of Field Relay Actuation Due to Incorrect Wiring.Electrical Schematic Revised to Show Proper Wiring Procedure.Relay Rewired +
- ML20127A045 +
- 05000352/LER-1993-004-02, :on 930405,primary Containment & Reactor Vessel Isolation Control Sys Actuation Occurred During Test of NSSSS-refueling Area Ventilation Exhaust Duct.Caused by Personnel Error.Technician Counseled +
- ML20028H325 +
- IR 05000269/1977007 +
- ML24295A361 +
- ML19220C737 +
- 05000311/LER-1991-007-02, :on 910522,channel Failure Occurred.Caused by Equipment Design Concerns.Failed Channel Control Module Replaced & Channel Functional Test Successfully Completed +
- 05000315/LER-1998-042, :on 981023,two RHR Pumps Ran with Unit Depressurized,Contrary to UFSAR Section 9.6.3.2.Caused by Inadequate Communications within Operations Organization. Procedures Have Been Revised.With +
- 05000315/LER-1997-015, :on 970902,discovered That 609 Drumming Room Did Not Meet FSAR Criterion for Monitoring of Fuel & Waste Storage.Interim LER 97-015-00 Retracted +
- 05000316/LER-1990-002, :on 900108,two MSIVs Exhibited Closing Time in Excess of Tech Spec 3.7.1.5 Limit of 5 S.On 900109 & 10, Confirmed That Excessive Condensation Collected on Vent Side.Caused by Inadequate Insulation +
- 05000397/LER-1993-006, :on 930206,manual Reactor Scram Initiated Due to Reactor Recirculation Pump Trip While Operating in Area of Increased Awareness.Caused by Component Design Not within Parameter Limits.Procedures Changed +
- 05000397/LER-1988-016, :on 880518,reactor Protection Sys Actuation Ocurred.Caused by Error in Plant Design.Event Discussed in Mechanics Shop Meeting & Article Describing Event to Be Included in Prefuelling Outage Bulletin +
- IR 05000249/1986006 +
- ML17199F997 +
- ML15239A175 +
- PLA-7985, Annual Radiological Environmental Operating Report +
- 05000374/LER-1998-001, :on 980106,indications,isolations & Alarms Occurred Due to Trip of 2B RPS MG Set Output Breaker & Concurrent Tripping of Electrical Protection Assembly. Replaced Circuit Board Containing Overvoltage Relay +
- 05000353/LER-1991-029-01, On 911223,reactor Containment & Isolation Control Sys Activated.Caused by Failure of PCRVICS Fuse B21 H-F15A.All Sys Responded as Designed.Fuse Replaced & All Isolations Reset +
- 05000333/LER-1995-010-01, :on 950530,TS Required Plant Shutdown Due to Unidentified Leakage Into Drywell.Repacked Valve 02-RWR-52B Using Current Maint Practice of Repacking w/non-asbestos Graphite +