- 05000293/LER-2004-002, High Pressure Coolant Injection System Fuse Failure While System Inoperable for Planned Maintenance and Testing +
- ML18153A303 +
- ML19325C287 +
- BVY-05-013, January 2005 Monthly Operating Report for the Vermont Yankee Nuclear Power Station +
- ML050530186 +
- ML20115A100 +
- ML20199D031 +
- 05000311/LER-1982-110, Forwards LER 82-110/03L-0.Detailed Event Analysis Encl +
- ML20244E083 +
- ST-HL-AE-3050, Requests Discretionary Enforcement to Provide Temporary Relief from Tech Spec Requirement 3.8.1.1.d +
- BVY-92-104, Monthly Operating Rept for Aug 1992 for Vermont Yankee.W/ +
- ST-HL-AE-4166, Special Rept:On 920630,CR Annunciator Lamp 22M01 Window F-1, Isolation Valve Cubicle Temp High Alarmed.Caused by Train D Cubicle Temp.Investigation Into Root Cause Ongoing +
- ML20058J876 +
- 05000282/LER-1989-012, :on 890804-15,automatic Actuation of Control Room 121 Clean Up Fan & Isolation of Outside Air to Control Room Occurred.Caused by Failure of Chlorine Gas Monitor. Monitors Will Be Sent to Mfg for Testing +
- 05000346/LER-1987-012, :on 870910,inadvertent,inconsequential Trip of Control Rod Drive Breakers in Hot Shutdown Occurred.Caused by Inadequate Surveillance Test Procedure.Change to Procedure Initiated +
- 05000498/LER-1988-036, :on 880607,unmonitored Release of 1,504 Gallons of Liquid Effluent Occurred.Caused by Personnel Error. Responsible Individual Counseled & Incident Reviewed W/ Others Involved W/Radioactive Effluents +
- 05000368/LER-1985-001, :on 850102,during Monthly Surveillance Testing of Plant Protection Sys Channel A,Inadvertent Actuation of Recirculation Actuation Sys Occurred.Caused by Spurious Matrix Logic Signal +
- 05000352/LER-1995-006-01, :on 950828,unusual Event & RPS Actuation Occurred After Reactor Manually Shutdown Due to Leak Into Primary Contaiment & Temporary Loss of Normal Startup Level Control Valve.Conducted All Hands Meeting +
- 05000267/LER-1983-025-03, /03L-0:on 830721-0806,reactor Operated in Degraded Modes of Limiting Condition for Operation 4.2.10.Caused by 830317 High Moisture Scram.Reactor Power Restricted While Helium Purification Sys Removed Impurities +
- 05000331/LER-1994-003, :on 940124,determined That TS Table 3.2-A Action Statement for Off Gas Vent RMs Not Complied W/During Routine Maint on 940119 Due to Improperly Prepared Work Document.License Amend Process Revised +
- 05000287/LER-1981-015, Forwards LER 81-015/01T-0.Detailed Event Analysis Encl +
- ML19345A713 +
- ML19344A426 +
- 05000397/LER-1993-029, :on 930805,discovered Primary Coolant Steam Leak.Caused by Weld Defect.Weld Crack Repaired on 930806. Weld Record for Applicable Weld Also Reviewed & No Discrepancies Identified +
- 05000373/LER-1990-007, :on 900618,during Operating Surveillance,Rcic Turbine Tripped on Mechanical Overspeed.Caused by Contaminated Oil in Lube Oil Sys.Oil Sys Flushed,Oil Changed & Limit Switch Readjusted +
- 05000373/LER-1990-007-07, :on 900618,RCIC Trip on Mechanical Overspeed Occurred During Surveillance Testing.Investigation Into Root Cause of Event Continuing.Actuator Disassembled & Cleaned +