- ML17326A953 +
- ML19327A940 +
- ML19322A442 +
- ML023510521 +
- ML20087D382 +
- ML20127P239 +
- U-601309, Ro:On 881111,generator Trip W/Reactor Scram Occurred Due to Sudden Pressure Actuation on 1C Main Power Transformer & Fire on Insulator of 1C Main Power Transformer Discovered. Fire Extinguished +
- ML20153H423 +
- BECO-LTR-94-103, Monthly Operating Rept for Aug 1994 for Pilgrim Nuclear Plant +
- 05000155/LER-1989-005-01, :on 890222,resident Inspector Observed Some Degradation on Rubber Seal of Containment Vent Valve.Shift Supervisor Conducted 10CFR50,App J Type B Leak Rate Test & Found Unacceptable Leakage.Caused by Aging +
- 05000219/LER-1987-005, :on 870116,high Flux Reactor Scram Occurred Due to Increased Recirculation Flow.Caused by Starting of Pump W/Discharge Valve Partially Open.Second Scram Occurred Due to Calibr Error.Valves Readjusted +
- 05000440/LER-1997-011, :on 970921,TS Surveillance Test Performance Resulted in Esfas.Caused by Procedure Weakness.Temporarily Revised SVI-B21-T2010 & SVI-B21-T2202 to Allow Completion of Instrument Check Valve Testing +
- 05000331/LER-1987-003, :on 870223,RWCU Sys Isolated on Signal from Room B Differential Temp Switch Located in RWCU Pump Room. Caused by Failure of Redundant Instrumentation. Instrumentation Replaced +
- 05000413/LER-1997-011-02, :on 971230,operators Indentified RCS Leak. Caused by Leakage Through Two Drain Valves,Tightly Closed. Leaking Valves Located & Closed +
- 05000325/LER-1996-007, :on 960609,high Pressure Coolant Injection Sys Declared Inoperable Due to Steam Supply Valve Packing Leak. Refurbished Valve & Corrected Off Center Condition +
- 05000325/LER-1996-007-01, :on 960509,high Pressure Coolant Injection Declared Inoperable.Caused by Degradation of Valve Stem Packing.Valve 1-E41-F001 Repaired & Valve Packing Replaced +
- 05000293/LER-1996-001-01, :on 960312,torus-to-reactor Bldg Vacuum Relief Sys Train B Vacuum Breaker Inoperable Due to Pressure Switch.Replaced micor-switch,tested Pressure Switch Satisfactorily & Returned Vacuum to Svc +
- 05000293/LER-1991-024, :on 911030,loss of Preferred & Secondary Offsite Power Occurred Due to Severe Coastal Storm While Shut Down.Caused by Flashover Switchyard Insulator. Westinghouse Type Relay 62/5 Will Be Replaced +
- ML20087A786 +
- 05000245/LER-1993-012-02, :on 930917,components Supporting Safety Related Function of FWCI Sys Were Not Category 1 or Seismically Qualified.Caused by Failure to Incorporate Sep. Upgrade Mepl for Millstone Unit 1 +
- 05000423/LER-1990-014, :on 900519,manual Reactor Trip Initiated as Result of Anticipated Turbine Trip Due to Condenser Vacuum. Caused by Design Deficiency in That Traveling Screen Capacity Inadequate.Traveling Screen Modified +
- IR 05000324/1981002 +
- 05000346/LER-1980-068-03, /03L-0:on 800901,all Indicators for Meteorological Instrumentation Failed.Caused by Lightning Striking Tower, Resulting in High Voltage Spike in Wind Direction Sensor. Repairs to Tower Sensors and Comstar Computer Completed +
- NUREG-0227, Partial Draft of Nuclear Power Plant Operating Experience - 1978, Section 3.0, Plant Outages. Portions of NUREG-0483, NUREG-0366 & NUREG-0227 (Plant Operating Experience for 1977,1976 & 1974-75,respectively) Encl +
- 05000316/LER-1994-008-01, :on 941211,4B Feedwater Heater Extreme High Level Alarm Received & Turbine Trip Resulted.Cause Related to Configuration of Alternate Drain line.High-high Level Alarm Switches Repaired & Tested +
- ML17139C364 +
- IR 05000275/1987026 +
- 05000249/LER-2002-002, Reactor Scram Due to Main Shaft Oil Pump Failure +
- ML24347A166 +
- 05000423/LER-1998-044, :on 981111,manual Reactor Trip Initiated When Differential Pressure Between a & B CWS Condensers Measured Greater than 2 Inches Water Gauge.Caused by High Levels of Debris Impinging.Modified Procedures +
- 05000277/LER-1991-014, :on 910521,isolation of HPCI Sys Occurred Unexpectedly During Surveillance Test.Caused by Leaking Isolation Valve,Resulting in Pressurization of Switch.Valve Replaced & Test Performed Satisfactorily +