- 05000325/LER-1987-010-01, :on 870430,reactor Protection Sys Tripped. Caused by Spurious Electronic Noise Spike Resulting from Attempts to Withdraw Control Rod.Plant Mod Alleviating Electronic Noise Problem Will Be Installed +
- 05000338/LER-1986-013-01, :on 860813,while at 100% Power,Rcs Unidentified Leakage Found in Excess of Allowable Tech Spec Limits.Caused by Leak in Resistance Temp Detector Loop C Bypass Flow Element.Flow Element Isolated +
- 05000414/LER-1998-004-04, :on 980906,de-energization of Vital Bus & Actuation of LTOP Occurred.Caused by Error During Tagout. Power Was Restored to 2ETB IAW Plant Procedure AP/2/A/5500/ 07 & Individuals Involved Were Counseled Re Subject Error +
- 05000499/LER-1996-003, :on 960828,failure to Fully Meet Requirements of TS Occurred,Due to Discovery of Improperly Installed Jumper on Main Steam Line Pressure Lead/Lag Circuit Card. Personnel Issues Have Been Addressed +
- 05000341/LER-1996-007, :on 960419,RCIC Sys Declared Inoperable Due to Turbine Shaft Gland Leakage.Caused by Steam Leakage Past Seat of RCIC Turbine Steam Admission Valve +
- 05000339/LER-1985-004-01, :on 850318,forced Unit Rampdown from 100% Power Occurred.Caused by Inoperable Emergency Diesel Generator 2J Which Tripped on High Crankcase Pressure & Removed from Svc.Emergency Generator Repaired +
- 05000219/LER-1992-001-01, :on 920312,rept Received Re Sparks from Status Lights for Undervoltage Protection Circuit in Front of 4,160 Volt Emergency Switchgear.Caused by Design of Lamp Sockets & Circuitry.Damaged Wiring & Fuse Replaced +
- 05000333/LER-1994-007-01, :on 941030,unanticipated RCIC Outboard Core Isolation Valve Isolation Signal Received.Caused by Poor Work Practices.Rcic Exhaust Diaphragms Replaced +
- 05000277/LER-1994-008-02, :on 940909,discovered That ECCS & EDG May Have Been TS Inoperable on 940803 When ESW Outlet Valve MO-0498 Closed & Left Unattended,Causing ECT to Overflow.Valve Opened & ECT Level Restored to Normal Range.W/Undated Ltr +
- ML20059J130 +
- PLA-8095, 2023 Annual Radiological Environmental Operating Report (PLA-8095) +
- PLA-8122, Annual Radiological Environmental Operating Report (PLA-8122) +
- 05000346/LER-1984-003-01, :on 840302,w/unit Operating at 99% Power,Msiv Closed,Isolating Steam Side of Steam Generator 2.Caused by Undetected Failed Relay in Safety Instrumentation Channel. Relay Replaced +
- 05000346/LER-1984-003, :on 840302,MSIV 2 Closed,Isolating Steam Side of Steam Generator 2.Caused by Failed Relay in Safety Instrumentation Channel.Msiv Replaced +
- 05000267/LER-1983-054-03, /03L-0:on 831213,emergency Feedwater Supply Header to Loop I Helium Circulators Unavailable to Drive Circulator Water Turbines.Caused by Repair to Safety Relief Valves & Pressure Control Valve +