Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ENS 44710 +
- ML12004A014 +
- ML17331A902 +
- ML100610448 +
- ML092230129 +
- ML19208B836 +
- 05000267/LER-1980-005, Forwards LER 80-005/03L-0 +
- ML19309D802 +
- ML050960327 +
- ML050880391 +
- ML050490405 +
- ML20082S913 +
- ML20078P409 +
- ML20129G167 +
- ML20154B096 +
- IR 05000454/1986013 +
- ML20207J032 +
- ML20215B194 +
- ML20215B097 +
- 2CAN078906, Monthly Operating Rept for June 1989 for Arkansas Nuclear One,Unit 2 +
- 05000245/LER-1989-015, :on 890602,reactor Scram Occurred During Startup Due to Condenser Low Vacuum.Caused by Personnel Error.Operations Dept Instruction 1-OPS-2.01 Revised.Event Discussed in Detail W/Operators Involved +
- 05000341/LER-1998-002, :on 980220,inadvertent Load Shed of ESF Bus 72E During Performance of Surveillance Test Resulting in ESF Actuations Occurred.Caused by Inadequate Procedure Rev. Power Was Restored to Affected Loads by 1344 Hrs on 980220 +
- 05000397/LER-1986-023, :on 860710,reactor Scram Occurred Following Opening of Incorrect Circuit Breaker During Electrical Ground Isolation.Caused by Personnel Error.Engineer Drawing & Circuit Breaker Labeling Will Be Changed +
- 05000269/LER-1998-018, :on 981209,identified Potential for Loss of Essential Siphon Vacuum Sys.Caused by Design Oversight. Procedure Revised.With +
- 05000336/LER-1988-004-01, :0n 880126,inadvertent ESF Actuation Occurred. Caused by Personnel Error.Testing Suspended & Equipment Disconnected & Retest Procedure Revised to Provide Step by Step Details on Checking Isolation Transformer +
- 05000341/LER-1985-042, :on 850722,emergency Equipment Cooling & Svc Water Sys Automatically Started in Response to Low Differential Pressure Condition.Cause Undetermined +
- 05000254/LER-1996-023-01, :on 961124,CR Emergency Filtration Sys Failed to Maintain Required Airflow Due to Cognitive Personnel Error.Instrument Loop for Gauge Fi 1/2-5795-307 Calibr +
- 05000269/LER-1994-005-03, :on 941005,containment Isolation Valve 1RC-7 Rendered Technically Inoperable Due to Change Mgt.Valves 1RC-5 & 6 Closed & Electrically Deactivated & Mechanical Maint Team Involved Counseled +
- 05000346/LER-1978-028-03, /03L-0:on 780318,channel 1 Steam Generator 1-1 Declared Inoperable.Caused by Water in Level Transmitter SP09B8 Connecting Box Due to Steam Leak.Connection Box Cleaned & Dried.Waterproof Fitting Will Be Installed +
- 05000272/LER-2077-027-01, Loss of Vital Bus +
- 05000316/LER-2077-005, Re Failure of 600 Volt Buses to Be Energized by Emergency Diesel Generators Due to Personnel Error & Equipment Failure +
- 05000281/LER-1987-005-03, :on 871014 Electrician Inadvertently Completed Flood Protection Circuit Causing Two of Four Condenser Circulating Water Inlet Valves to Close.Caused by Personnel Error.Procedure Written for Maint Personnel +
- 05000400/LER-1987-019, :on 870412,manual Plant Trip Initiated Due to Loss of Feedwater Trains & Decreasing Steam Generator Levels.Caused by Condensate Pump High Temp Trip.Pressure & Steam Generator Levels Restored +
- 05000397/LER-1993-006, :on 930206,manual Reactor Scram Initiated Due to Reactor Recirculation Pump Trip While Operating in Area of Increased Awareness.Caused by Component Design Not within Parameter Limits.Procedures Changed +
- 05000373/LER-2014-003, Regarding Secondary Containment Inoperable Due to Interlock Doors Open +
- ML14184B070 +
- 05000395/LER-1993-002, :on 930318,determined 1 Percent of SG Tubes Defective.Caused by Pwscc.Defective Tubes Plugged +