- PNO-I-90-005A, updates Notification of Malfunction of Source Transfer Tube in Remote Afterloading Brachytherapy Irradiator.Licensee Informed Region of Two Addl Incidents Involving Same Afterloader That Also Occurred on 900118 + (03007854)
- IR 05000810/2009003 + (03008048)
- PNO-I-85-077, on 851008,radiographer Received Whole Body Dose of 15.5 Rem.Caused by Failure to Retract 100-Ci Ir-192 Source to Shielded Position in Exposure Device.Radiographer Removed from Radiation Work for Remainder of Quarter + (03008168)
- ML18197A382 + (03008181)
- PNO-I-97-011, on 970214,misadministration Involving Diagnostic Dose of I-131 Occurred.Referring Physician Reportedly Decided Not to Inform Patient,Because of Patient Advanced Age & Medical Condition + (03008184)
- PNO-I-88-044, on 880414,radiological Control Personnel Found Leaking Tritium Light Source,Containing 10 Curies of Activity Subject to X-ray Exam W/O Authority or Radiological Controls.Facility Shut Down Immediately on 880414 + (03008220)
- PNO-III-97-007A, on 970127,missing or Lost Devices at Army Facilities Update made.NRC-licensed Activities Conducted Under Licenses by Military Installation Coordinated & Supervised by Licensees Facility in Rock Island,Il + (03008220)
- PNO-III-87-142, on 871121,licensee Employee Allegedly Forced Out of Car,Containing Troxler Moisture Density Gauge in Trunk,At Gunpoint at Fast Food Restaurant in Detroit,Mi. Theft Reported to Police + (03008223)
- PNO-III-82-056, on 820620,truck Containing Troxler Soil Moisture Density Gauge Was Stolen from Job Site in Detroit. Gauge Contains One 8-mCi Cs-137 Source & One 40-mCi Am-241 Source.Sources Locked in Shielded Position + (03008223)
- PNO-III-97-023, on 970306,patient Administered 10 Mci of I-131 for Hyperthyroidism Instead of Prescribed Dosage of 20 Mci of I-131.Nuclear Medicine Technologist Did Not Check Written Directive Prior to Administering Dosage + (03008298)
- ML18162A137 + (03008325)
- ML18197A200 + (03008325)
- PNO-I-90-019, on 900306,containers Holding Ba-133,Cs-137 & Co-57 Found at Site of Demolition of Bldg Formerly Known as Licensee Facility.Licensee Agreed to Cease Demolition in Former Nuclear Medicine Areas & Post Security Guard + (03008449)
- PNO-V-90-048, on 901126,diagnostic Misadministration Occurred w/73 Yr Old Patient Given 250 Mci of Tc99m.Patient Hospitalized & Being Administered Thyroid Blocking Agents + (03008456)
- PNO-V-90-042A, on 901102,contamination of Hosp Labs & Public Areas Noted.Nrc Confirmed Licensee Monitoring Indicating That Contamination Removed to Acceptable Levels & Posed No Health Hazard to Workers or General Public + (03008456)
- PNO-V-90-042, on 901102,contamination Found in Eight Labs & Public Areas,Involving Unknown Amount of P-32.Licensee in Process of Decontaminating Labs & Assessing Contamination + (03008456)
- PNO-III-94-003, on 940119,patient Was Administered Sodium Iodide I-131 Capsule Containing 9.1 Mci Rather than Prescribed 15 Mci.Caused by Technician Erroneously Assuming Vial Contained Only One Capsule + (03008523)
- ML18213A122 + (03008561)
- ML18212A331 + (03008561)
- PNO-I-97-076, on 971211,unshielded 10 Mci Eu-152 Sealed Source Found in Back of Federal Express Truck in Id Falls, Id.Source Retrieved & Placed Into Shielded Container & Placed in Secured Storage by DOE + (03008562)
- ML18204A117 + (03008599)
- PNO-I-88-032A, on 880317,fire Occurred.Two Gas Chromatographs Containing Radioactive Matl Completely Burned.Cause Under Investigation.Licensee Will Develop Plan for Safely Removing Radioactive Matl Before re-entering Bldg + (03008666)
- PNO-I-88-032, on 880317,explosion & Fire Reported at Licensee Facility.Three Deaths & One Injury Reported.Licensed Matl Not Believed to Be Involved.Region I Preparing Press Release + (03008666)
- ML19281D003 + (03008681)
- PNO-III-99-013, on 990318,licensee Removed Gynecological Radiation Treatment Device from Patient & Found That One of Two 27.5 Mci Cs-137 Sealed Sources Was Missing.Patient Has Been Informed of Misadministration + (03008699)
- PNO-IV-89-072, on 891221,darkroom Encl of Licensee Vehicle, Containing 75 Ci Ir-192 Source,Blown from Truck Bed During 40-50 Mph Winds.Insp Revealed No Apparent Damage to Locking Mechanism or Fittings for Control Cables or Guide Tubes + (03008719)
- PNO-I-83-043, on 830430,Troxler Gauge 34-ll-B,containing Approx 40 Mci Am-241 Damaged at Const Site.Caused by Accidentally Cracking Gauge Case W/Backhoe Bucket.Wipes Taken & Analyzed.Gauge Shipped to Manufacturer for Repair + (03008778)
- ML18240A076 + (03008783)
- PNO-III-86-026A, on 860320,two Lab Areas Determined Contaminated W/Tritium.Labs Locked Pending Decontamination. Investigation Continuing.Inspector Will Meet W/Concerned Students & State of Mi Will Be Informed + (03008783)
- PNO-III-86-026B, on 850803 & 1217 & 860126,licensee Researcher Received Tritium Overexposure.Caused by Tritium Entering Lab from Hood Where Experiment Performed.Main Lab Remains Secured Pending Completion of Decontamination + (03008783)
- PNO-III-86-026, individual May Have Received 9,500 Mpc H While Using 5 Ci Tritiated Water.Confirmatory Action Ltr Will Be Sent Documenting Agreement to Temporarily Remove Researcher & Restrict Access + (03008783)
- PNO-I-86-046, on 860627,two Packages Containing Two Dose Units of 20 Mci Xe-133 & One Dose Unit of 12 Mci Ga-67 Fell Out of Truck During Transport.Matl Believed to Be in Inaccessible Dense Underbrush.Safety Hazard Minimal + (03008971)
- PNO-I-87-021, on 870313,delivery Vehicle Carrying Radioactive Matl from Mallinckrodt,Inc & Medi-Physics Slid Off Road. Radiation Survey Found No Leakage or Radioactive Contamination.Packages Recovered & Taken to Destinations + (03000001)
- PNO-I-87-081, on 870819,inspectors Learned That Licensee Had Been Operating walk-in Irradiator Since Late May 1987 W/O Radiation Detector.Cause Not Stated.All Isomedix Irradiators Will Be Inspected + (03008985)
- ML18190A496 + (03009049)
- PNO-I-85-081, on 851022,missing 50-mCi Cs-137 Brachytherapy Source Reported.Source Possibly Removed from Premises by Laundry Servicer.State of Nj Informed + (03009062)
- PNO-I-85-074, wastes Containing I-125,H-3,I-131,Cl-36 & P-32 Lost.Untrained Custodial Worker Entered Labs & Emptied Wastes Into Normal Trash Compactor.Waste Removed & Disposed of in Saugus,Ma + (03009062)
- ML18233A434 + (03009152)
- PNO-IV-88-064, on 880804,licensee Physicist Reported Therapy Misadministration Involving Four Cs-137 Implant Sources of Combined 260 Mci Implanted Into 72 Yr Old Patient.Patient Demented & Removed Sources.No Effects on Patient Noted + (03009152)
- PNO-II-93-070, on 931206,two Cs-137 Sources of Total 60 Mci Inserted Into Patient Via Vaginal Applicator.Later Girdle Holding Sources in Place Was Replaced.On 971207 Nurse Saw Sources Outside Patient.Region II to Perform Special Insp + (03009164)
- Press Release-I-05-007, NRC Officials to Meet with Pennsylvania Hospital to Discuss Oversight of Radiation Safety Program + (03009176)
- PNO-III-99-017, on 990402,medical Misadministration Occurred, When Patient Received Single Fraction Radiation Dose of 200 Rads to Head Area with Theratron Co-60 Teletherapy Unit Containing Nominal 13,000 Ci.Licensee Notified NRC + (03009222)
- ML18221A316 + (03009259)
- ML18206A188 + (03009345)
- ML18205A603 + (03009366)
- ML18197A290 + (03009376)
- PNO-III-92-014, on 920316,licensee Reported Teletherapy Misadministration Which Occurred on 920224,in Which Patient Received Radiation Dose of 180 Rads to Wrong Side of Chest. Region III Will Conduct Special Insp During Wk of 920323 + (03009376)
- ML18191B107 + (03009398)
- ML18233A364 + (03009486)
- ML18233A363 + (03009486)
- PNO-III-97-066, on 970813,nurse Observed That Tandem Had Moved Partially Out of Position.Nurse Immediately Contacted RSO & Authorized User Physician.Patient Immediately Notified of Misadministration + (03009491)
- ML18206A703 + (03009516)
- ML18206A675 + (03009516)
- ML18205A495 + (03009516)