Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20213F889 + (ML20213F889)
- ML20213F890 + (ML20213F890)
- ML20213F892 + (ML20213F892)
- ML20213F894 + (ML20213F894)
- ML20213F895 + (ML20213F895)
- ML20213F898 + (ML20213F898)
- ML20213F900 + (ML20213F900)
- ML20213F901 + (ML20213F901)
- 05000382/LER-1986-023, :on 861020,reactor Tripped Coincident W/ Emergency Feedwater Actuation.Caused by Dropped Control Element Assembly Due to Failed Lower Gripper Hall Effect Sensor on Assembly 21.Sensor Replaced + (ML20213F906)
- IR 05000369/1986030 + (ML20213F908)
- ML20213F909 + (ML20213F909)
- 05000249/LER-1986-018-06, :on 861014,Group V (Isolation Condenser) Containment Isolation Signal Received.Corrective Actions Will Be Considered When Cause Determined + (ML20213F910)
- ML20213F911 + (ML20213F911)
- ML20213F913 + (ML20213F913)
- 05000440/LER-1986-068, :on 861014,16 & 22,RWCU Isolations Occurred Due to High Indicated Differential Flow After Design Problems W/Placement of RWCU Blowdown Line Flow Element.Engineering Design Change to Relocate Element Initiated + (ML20213F914)
- ML20213F920 + (ML20213F920)
- ML20213F921 + (ML20213F921)
- ML20213F923 + (ML20213F923)
- ML20213F925 + (ML20213F925)
- 05000382/LER-1986-022, :on 861020,control Room Isolation Occurred. Caused by Degraded Electrical Connection in Barton Model 765 Flow Transmitter.Transmitter Replaced + (ML20213F926)
- 05000249/LER-1986-017-07, :on 861014,Group I Isolated & Subsequent Reactor Scram Occurred.Caused When Contractor Inadvertently Jarred Msivs.Personnel Counseled + (ML20213F929)
- ML20213F930 + (ML20213F930)
- ML20213F931 + (ML20213F931)
- ML20213F934 + (ML20213F934)
- ML20213F935 + (ML20213F935)
- ML20213F938 + (ML20213F938)
- IA-87-217, Package,Including Morning Rept Re Plant 861209 Rupture of Suction Line on Main Feedwater Unit a & Drawings + (ML20213F940)
- ML20213F940 + (ML20213F940)
- ML20213F944 + (ML20213F944)
- ML20213F946 + (ML20213F946)
- ML20213F948 + (ML20213F948)
- ML20213F951 + (ML20213F951)
- ML20213F952 + (ML20213F952)
- 05000272/LER-1986-019-01, :on 861001,two 2-inch Conduit Penetrations in Svc Water Intake Structure Fire Barrier Wall Discovered Improperly Sealed Per Tech Spec 3.7.11.Cause Undetermined. Penetration Sealed.Investigation Continuing + (ML20213F953)
- ML20213F954 + (ML20213F954)
- ML20213F955 + (ML20213F955)
- ML20213F959 + (ML20213F959)
- ML20213F964 + (ML20213F964)
- ML20213F966 + (ML20213F966)
- ML20213F967 + (ML20213F967)
- IR 05000302/1986036 + (ML20213F971)
- ML20213F973 + (ML20213F973)
- ML20213F975 + (ML20213F975)
- ML20213F976 + (ML20213F976)
- ML20213F977 + (ML20213F977)
- ML20213F980 + (ML20213F980)
- ML20213F981 + (ML20213F981)
- ML20213F982 + (ML20213F982)
- ML20213F988 + (ML20213F988)
- ML20213F989 + (ML20213F989)
- ML20213F990 + (ML20213F990)
- ML20213F991 + (ML20213F991)