ML20213F944

From kanterella
Jump to navigation Jump to search
Advises That B Griffin Assigned to Review Region IV Allegation 4-85-A-123 Investigation & Write Independent Rept Evaluating Adequacy of Util Investigation,Per 860214 Telcon. Case Chronology Encl
ML20213F944
Person / Time
Site: Comanche Peak  
Issue date: 02/14/1986
From: Herr R
NRC OFFICE OF INVESTIGATIONS (OI)
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20213F915 List:
References
FOIA-87-91 NUDOCS 8705180052
Download: ML20213F944 (5)


Text

..:.w w.:.

. --n - n het.,-- - - ~a mmw -

a m e*~ ~< 'm*r*+~ --.*~ ~ --

~ ~ -.

~-

,~,

jf 4

UNITED STATES

['

NUCLEAR REGULATORY COMMISSION

,e o

ij OFFICE OF INVESTIGATIONS FIELD OFFICE, REGloN IV h,,,,*

ING N, TEX S 1

February 14, 1986 MEMORANDUM FCR:

Robert D. Martin, Regional Administrator Region IV FROM:

Richard K. Herr, Director Office of Investigations Field Office, Region IV

SUBJECT:

Region IV MEMO DATED JANUARY 31, 1986 RE: REGION IV ALLEGATION 4-85-A-123 On February 14, 1986 at 0950, I received a telephone call from Bill Hutchison, 0IHQ, wherein he advised me that Mr. Hayes has approved 01 assistance to Region IV as requested in subject letter.

I have assigned 01 Investigator Brooks Griffin to review the subject investigation and write an independent report evaluating the adequacy of the utility's investigation.

Mr.-Griffin will coordinate his review with Tom Westerman at CPSES during the week of February 18, 1986.

8705180052 870513 PDR FOIA BAUMAN87-91 PDR

w - - -

.~.. <., ~ :_nww--a n.

. an-~ _~ _.

n

--?

GFFICIAL USE ONLY A-<

CASE CHRONOLOGY FfL IeuMSE R OATE OPENED DPENED BY 4 -n - cv 3 2-m-%

Gr: CRa St.TE ACTivlTT

~2m-u nand Akcid *> re vlw astea uaes J 1~un&O

)Jxs k L

& ~ J7%en i L (6 4 % T k oar k ip,k

~

u nka week' R

kb=l& W x-ts-n

._ fab d a w/ AlaZA a

_ pr/

-. =l/d

.I

. ~~ Y.

{YN?(W

-l-O/N --

N, f_ __ 2.-X N

/3ZV W

~~

_ MlW ZI4 /Olp $ 4

' A caw--

M S

&1

' O./ $_fb4 e

~__

l

]

___.. ~. _.

)

]

j CCTIVITY CCDES L/W e LETTER OR WENO TC

  • TELEPHONE CALL INSP e INSPECTION WTO e ME TING eNV a INVEST 6GAf t0N REP REPORT ISSUED OFFICIAL USE ONLY DO NOT DISCLOSE

---+..-w--

..n-

<- n -,, ~: we wm :cw~ o.o

.e

, w-

+w

~+m.

-~~.n,-

  • f

_r s

esRC FORM 308' U.S. NUCLEAR KEIULAToRY COMMISSION G42)

INVESTIGATION STATUS RECORD 1888TIUCTIONS: This form is to be completed whenever sigmficant activity has occurred relative to a case or et least every 30 days. If no change has occurred during the 30 dey reporting per od, indicate No Change" in the status block. Keep the original with the Case file and send one copy to Headquarters, offee of Investigations.

cast NuwstR CAf tGORY OFFICE O. OPERATING REACTOR S. INDavfDUAL LICENSEE A4-86-003 2

C ' "l3^ClCc'Co,'"

u. uAnRiAtstruet Office of Investigations Field Office, Region IV v.venoom x.oTweR Assicheo Yo susac' COMANCHE PEAK STEAM ELECTRIC STATION:

H. Brooks Griffin ASSIST IN REVIEW OF TUCCO INVESTIGATION STATUS (Specify date, and proncle a bnet description)

An anonymous alleger telephonically contacted the NRC and identified an EBASCO walkdown engineer at Comanche Peak who had created a " climate of fear" among the engineering staff in order to prevent the engineers from identifying certain errors and deficiencies. The alleger hiso notified the utility which conducted an investigation. Region IV requested that OI:RIV assist in reviewing and evaluating the adequacy of the utility's investigation.

ECD: 4/86

/

DATE:

Feb. 28, 1986 - This assist was approved by OI:HQ in Feb. 1986. This case has been completed. Anticipate final report to be completed in March 1986. ECD: 3/86 Resources Available: YES DATE: March 7, 1986 - Aesist closed. Report transmitted to R. Martin, RA, RIV, on this date.

B 2-

A e

INVESTIGATIVE PLAN CASE NUfGER: <d 4' //, - M3 DATE:

2- /y -fg

[ R 6 C C /+V 6 fy d b,q,

[,Gl4f [e )c4,W M D'<I'n/

C TITLE:

PIMT/VEMR: [o w,A d g

[gd IWESTIGATOR: hPW/4

SUMMARY

ghf0 jy JpS g f/g ch.

1. " -

_ ' ;7, fpy;gg 4_y Ma -f 2.

5 h.

5

6. -

-7 8.

9 10.

COMMENTS:

W.

/fA Dl3

., _ _ -. _ ~. ~ ~ - -, - - - -

- - ~ ~ - - - - ~ ~ ~ ~ ~ - - - - - -

y 01Mih UAl A LfilRY FORM e

$Qfbo3 CFACILITY TYPE:

C 90 L/ b/6

  • TYPE F CASE:

, / (PWR)

POWER REACTOR / DOCKET # 09 t/L6 (A) ASSIST

'(NPWR) NON-POWER REACTOR /NAME '

(Q) INQUIRE

(VEND) VENDOR / DOCKET f (I) IllVESTIGATION (MLIC) MATERIAL LICENSE /NAME '

.(OTH) OTHER

/NAME

  • DATE OF RECEIPT:,2 /#-85 cTITLE: (Limit 100 Characters)

Reu,~ J nucoin n a INVESTIG INITIA"L' :

  • LEM 8 ll/

S eCASEJTATUS:

SOURCE OF ALLEGATION:

7

0) OPEN (1) LICENSEE T) TRANSFERRED (2) VENDOR A) CLOSED / ACTIVE (3) CONTRACTOR (C) CLOSED / INACTIVE (4)NRC
5) PUBLIC CFIELD WORK STATUS:

INTERVENOR PN PENDING 7 AN0l1YMOUS

/ FP FIELD WORK IN PROGRESS (8)OTHER FA FIELD WORK IN ABEYANCE (FC FIELD WORK COMPLETE TYPE,0F WRONGD0ING: (See Tl Table for Codes)

(DR DRAFT REPORT (HR HEADQUARTER REVIEW (IFOTHER:

)

(FR) FINAL REPORT ISSUED A.,,,/f y A C@gy yq DESCRIPTION: (Limit 500 Characters)

Udk fdlf C rec < U n Wck

%f;11 i' W l'

& [{bcrSccpy of af lN Se 7

@vf eed frc~

M te V7NNf Sh y S'19 g

Q )pF7 e {ew c ' f S 0

4 COMMENTS / REMARKS: (Limit 500 Characters)

[

[

L.

'3 L

i START DATE:

C2 - /f -ff FIELD OFFICE NUMBER:

ESTIMATED COMPLETION DATE:

~

~

ACTUAL COMPLETION DATE:

ZIP CODE:

ALL RELATED CASES:

REFERRAL:

ED0 (RS) PIGION 5 HQ OIA (R1) REGION 1 D0J (R2) REGION 2 LAW INF (R3) REGION 3 FBI (R4) REGION 4 OTHER cREQUIRED ELEMENT