Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20129C227 + (ML20129C227)
- 05000328/LER-1985-009-02, :on 850503,reactor Tripped Due to Main Turbine Trip.Caused by Main Generator Trip Due to Loss of Both Stator Cooling Water Pumps.Point Connector Removed & Wiring Inspected + (ML20129C229)
- ML20129C230 + (ML20129C230)
- LIC-96-0163, Forwards Application for Amend of Operating License DPR-40 & Tech Spec 4.3.2, Reactor Core & Control to Allow Use of Either Zircaloy or ZIRLO Cladding & Proposed Addl Ref to WCAP-12610 in TS 5.9.5b + (ML20129C232)
- ML20129C235 + (ML20129C235)
- ML20129C238 + (ML20129C238)
- ML20129C239 + (ML20129C239)
- ML20129C241 + (ML20129C241)
- PNO-IV-96-051, on 960920,radioactive Object Found at Scrap Yard.Nucor Representatives Stated Object Had Been Secured at Facility & That No Nucor Staff Had Touched or Come in Contact W/Object + (ML20129C243)
- ML20129C244 + (ML20129C244)
- IA-84-780, Forwards Listing of Util Responses to Generic Ltr 82-22 Re Economic & Worker Safety Aspects of Steam Generator Tube Degradation Problem.Supporting Documentation Encl + (ML20129C244)
- ML20129C245 + (ML20129C245)
- RBG-21406, Responds to Violations Noted in Insp Rept 50-458/85-23. Corrective Actions:Temp Indicating Device Being Used Per S&W Mechanical Test Procedure 1.MPGEN.003 + (ML20129C246)
- ML20129C247 + (ML20129C247)
- ML20129C248 + (ML20129C248)
- ML20129C249 + (ML20129C249)
- B11599, Forwards USGS Info Re SEP Topic II-3.B, Flooding Potential & Protection Requirements, Per 850530 Request.Info Consists of Connecticut River Rating Table at Bodkin Rock & Indicates That Stage Elevation Affected by Tidal Effects Up to 8.0 Ft + (ML20129C252)
- ML20129C253 + (ML20129C253)
- ML20129C256 + (ML20129C256)
- ML20129C259 + (ML20129C259)
- ML20129C260 + (ML20129C260)
- ML20129C261 + (ML20129C261)
- ML20129C262 + (ML20129C262)
- ML20129C266 + (ML20129C266)
- ML20129C270 + (ML20129C270)
- ML20129C271 + (ML20129C271)
- IR 05000334/1985016 + (ML20129C272)
- B15884, Responds to NRC Re Violations Noted in Insp Repts 50-245/96-05,50-336/96-05 & 50-423/96-05.Corrective Actions: Added TS Section 6.8.4 to Schedule of Next TS Audit & Counseled Audit Team Leader Re Effective Communication + (ML20129C274)
- ML20129C275 + (ML20129C275)
- ML20129C276 + (ML20129C276)
- ML20129C278 + (ML20129C278)
- ML20129C279 + (ML20129C279)
- ML20129C281 + (ML20129C281)
- ML20129C282 + (ML20129C282)
- ML20129C283 + (ML20129C283)
- ML20129C284 + (ML20129C284)
- ML20129C285 + (ML20129C285)
- RBG-21-572, Forwards Revs to FSAR & Proposed Tech Specs,Per Changes to Design Spec Data Sheets & Installation of New Rosemount Transmitters for Review + (ML20129C287)
- ML20129C288 + (ML20129C288)
- ML20129C289 + (ML20129C289)
- ST-HL-AE-1293, Forwards Responses to Main Cooling Reservoir Action Items Discussed in 850402 Meeting,Including Results from Supplemental Tests/Borings in Area Near Embankment Station 40 + 00 + (ML20129C294)
- ML20129C295 + (ML20129C295)
- ML20129C296 + (ML20129C296)
- IR 05000298/1985012 + (ML20129C297)
- PNO-III-85-054B, on 850702,newly Hired Mgt Employee Found Carrying .380 Caliber Handgun in Briefcase.On 850710,util Completed Investigation of Incident,Concluding Individual Did Not Represent Threat.Employee Fired on 850702 + (ML20129C298)
- ML20129C299 + (ML20129C299)
- ML20129C301 + (ML20129C301)
- 0CAN078501, Responds to Generic Ltr 85-07 Re Integrated Living Schedule Concept.Agrees W/Concept as Means of Assuring Timely Implementation of Necessary Plant Mods But Does Not Want to Incorporate Schedule Into OL + (ML20129C302)
- RBG-21684, Responds to Re Outstanding Tech Spec Issues. Interrupting Capability of Motor Contactors Test at Value Equal to Approx Locked Rotor Current of Associated Motors + (ML20129C303)
- ML20129C306 + (ML20129C306)
- ML20129C308 + (ML20129C308)