Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20083K729 + (ML20083K729)
- ML20083K730 + (ML20083K730)
- ML20083K734 + (ML20083K734)
- ML20083K735 + (ML20083K735)
- ML20083K736 + (ML20083K736)
- ML20083K737 + (ML20083K737)
- ML20083K738 + (ML20083K738)
- 05000277/LER-1978-050-03, /03L-0 on 781221:during Routine Surveillance Test, Time to Reach Rated V & Hz for E2 Diesel Was 11 Seconds, & 13 Seconds for E3 Diesel.Probably Due to Faulty Woodward Governor + (ML20083K747)
- ML20083K749 + (ML20083K749)
- ML20083K750 + (ML20083K750)
- 05000366/LER-1979-005, Forwards LER 79-005/03L-0 + (ML20083K751)
- ML20083K758 + (ML20083K758)
- ML20083K759 + (ML20083K759)
- 05000285/LER-1978-046, Forwards LER 78-046/03L-0 + (ML20083K760)
- ML20083K764 + (ML20083K764)
- 05000366/LER-1979-005-03, /03L-0 on 790103:under Frequency Trip Setpoint Found at 54.1HZ for Motor Generator Set A.Caused by pre-op Test on Sys.Surveillance Test HNP-2-3456 Contains Setpoint More Conservative than Tech Specs + (ML20083K766)
- ML20083K774 + (ML20083K774)
- ML20083K775 + (ML20083K775)
- ML20083K781 + (ML20083K781)
- ML20083K782 + (ML20083K782)
- ML20083K788 + (ML20083K788)
- 05000285/LER-1978-046-03, /03L-0 on 781227:during Operation,A Small Leak Developed at Weld on Charging Pump CH-1A Connection to Demineralized Water Line.Caused by Vibration of Piping in Svc.Crack Was Ground Out & Rewelded + (ML20083K789)
- 05000456/LER-1995-004-05, :on 950409,RT Occurred Due to Failed Capacitor in Firing Card That Caused Loss of Vital AC Instrument Bus 11.Replaced Firing Board in Instrument Inverter W/New One + (ML20083K790)
- ML20083K793 + (ML20083K793)
- ML20083K794 + (ML20083K794)
- ML20083K798 + (ML20083K798)
- 05000361/LER-1995-005, :on 950406,loss of Pressurizer Level Occurred Due to Valve Alignment Error.Terminated Event at 0207 When Licensee Reclosed mini-flow Isolation Valves + (ML20083K799)
- ML20083K803 + (ML20083K803)
- 05000306/LER-1978-024, Forwards LER 78-024/03L-0 + (ML20083K805)
- ML20083K806 + (ML20083K806)
- 05000361/LER-1995-006, :on 950406,RCS Dissolved Oxygen Found Out of Specification.Caused by Failure to Follow Procedure.Returned Oxygen Level to Below TS Steady State Limit by Addition of Hydrazine + (ML20083K810)
- ML20083K811 + (ML20083K811)
- ML20083K814 + (ML20083K814)
- 05000267/LER-1979-001, Forwards LER 79-001/03L-0 + (ML20083K817)
- ML20083K821 + (ML20083K821)
- 05000366/LER-1979-006, Forwards LER 79-006/03L-0 + (ML20083K825)
- 05000361/LER-1995-008, :on 950412,TS 3.0.3 Entry Occurred Due to Inoperable Containment Emergency Cooling Fans.Removed Fan Immediately Upon Discovery + (ML20083K828)
- 05000306/LER-1978-024-03, /03L-0 on 781226:Loop a Steam Flow Transmitter 2FT-464 Had Drifted Such That High Steam Flow Setpoint Would Have Occurred at 1.07x10 Lb/H.Caused by Instrument Drift in Barton Model 384 Differential Pressure Transmitter + (ML20083K832)
- 05000267/LER-1979-001-03, /03L-0 on 790102:total Primary Coolant Oxidant Concentration Exceeded 10 Vol Ppm While Core Average Outlet Temp Was Greater than 1200 F.Caused by Low Temp Absorber Heatup,Releasing Oxidant to Primary Coolant + (ML20083K836)
- 05000374/LER-1995-007-02, :on 950411,division 2 ESF Actuation Occurred Due to Instrument Ref Line Pressure Spike.Closed Injection Valve 2E12-F042C & Secured 2A DG + (ML20083K837)
- 05000366/LER-1979-006-03, /03L-0 on 790102:reactor Pressure Instrument Ft&C, Relay 2B21-K34A Failed to Operate W/Actuation of 2B21-N021A. Caused by Open Coil + (ML20083K840)
- 05000341/LER-1995-004, :on 950409,unexpected Reactor Water Level 2 & ESF Actuations Occurred After Planned Scram.Caused by Selection of Parameters Used in Post Scram FW Logic Mod Per Engineering Design Package 9207 Installed During RF04 + (ML20083K844)
- ML20083K845 + (ML20083K845)
- ML20083K846 + (ML20083K846)
- 05000325/LER-1978-090, Forwards LER 78-090/03L-0 + (ML20083K848)
- 05000325/LER-1978-090-03, /03L-0 on 781230:reactor Vessel Conductivity Exceeded 24-h Limit Due to Organic Compound in Condensate Storage Tank + (ML20083K857)
- ML20083K858 + (ML20083K858)
- ML20083K859 + (ML20083K859)
- 05000325/LER-1978-085, Forwards LER 78-085/03L-0 + (ML20083K867)
- ML20083K870 + (ML20083K870)
- ML20083K872 + (ML20083K872)