Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20079H172 + (ML20079H172)
- ML20079H175 + (ML20079H175)
- ML20079H178 + (ML20079H178)
- ML20079H181 + (ML20079H181)
- 05000305/LER-1983-037-03, /03L-0:on 831213,during Full Power,Svc Water Pump 1A2 Taken Out of Svc.Caused by Packing Leak on Svc Water Strainer.Strainer Repacked & Pump Tested + (ML20079H186)
- ML20079H187 + (ML20079H187)
- ML20079H190 + (ML20079H190)
- ML20079H193 + (ML20079H193)
- ML20079H198 + (ML20079H198)
- 05000285/LER-1983-004-03, Pressure Switches A/PC-742-1 & A/PC-742-2 Found Initiating/Actuating Above 5 Psig.Caused by Instrument Drift.Switches Recalibr + (ML20079H202)
- 05000366/LER-1983-129-03, /03L-0:on 831213,during QA Audit,Diesel Generator Testing Not Scheduled on Staggered Test Basis.Caused by Personnel Error.Diesel Generators Surveillance Scheduled Per Staggered Requirement + (ML20079H207)
- ML20079H208 + (ML20079H208)
- ML20079H209 + (ML20079H209)
- ML20079H212 + (ML20079H212)
- ML20079H214 + (ML20079H214)
- ML20079H217 + (ML20079H217)
- ML20079H223 + (ML20079H223)
- 05000305/LER-1983-036-03, /03L-0:on 831213,shield Bldg Ventilation Fan 1A Failed to Start During Monthly Surveillance Test.Caused by Procedural Error.Charcoal Filter Heat Detector Test Procedure Revised + (ML20079H225)
- BECO-84-012, Notifies That Harrington to Vassallo Misnumbered. Correct Tracking Number Is 83-309 + (ML20079H227)
- ML20079H231 + (ML20079H231)
- ML20079H238 + (ML20079H238)
- ML20079H239 + (ML20079H239)
- ML20079H240 + (ML20079H240)
- ML20079H244 + (ML20079H244)
- ML20079H248 + (ML20079H248)
- ML20079H252 + (ML20079H252)
- 05000254/LER-1991-017-01, :on 910904,B Train CR HVAC Emergency Air Filtration Unit Declared Inoperable Due to Equipment Failure & Inappropriate Heater Performance Criteria.Defective Differential Pressure Indicator Replaced + (ML20079H259)
- ML20079H263 + (ML20079H263)
- ML20079H264 + (ML20079H264)
- ML20079H265 + (ML20079H265)
- ML20079H268 + (ML20079H268)
- ML20079H274 + (ML20079H274)
- ML20079H276 + (ML20079H276)
- ML20079H282 + (ML20079H282)
- ML20079H289 + (ML20079H289)
- ML20079H291 + (ML20079H291)
- ML20079H295 + (ML20079H295)
- ML20079H298 + (ML20079H298)
- ML20079H302 + (ML20079H302)
- ML20079H305 + (ML20079H305)
- ML20079H307 + (ML20079H307)
- ML20079H317 + (ML20079H317)
- ML20079H324 + (ML20079H324)
- ML20079H326 + (ML20079H326)
- ML20079H331 + (ML20079H331)
- 05000302/LER-1983-030-03, During Routine surveillance,once-through Steam Generator a Operating Range Level Recorder Indicated Level Corresponding to 119 Inches, Rendering Recorder Inoperable + (ML20079H332)
- 05000373/LER-1983-154-03, /03L-0:on 831214,while Performing LES-EH-01, Reactor Protection Sys Limit Switch 1C71-N006E,for Turbine Stop Valve 2,found Out of Spec.Caused by Loose Set Screw Coupling Limit Switch to Actuating Arm + (ML20079H337)
- 3F0184-16, Application for Amend to License DPR-72 & Proposed Tech Spec Change Request 106,Rev 1 Re Control of Personnel Access to High Radiation Areas.Certificate of Svc Encl + (ML20079H339)
- ML20079H340 + (ML20079H340)
- ML20079H342 + (ML20079H342)
- ML20079H344 + (ML20079H344)