- NRC-94-4064, Forwards Proprietary & Nonproprietary Versions of AP600 Design Change Description Rept. Proprietary Version Withheld.Proprietary Portion of Document Sent to Westinghouse + (ML20063K055)
- ML20063K057 + (ML20063K057)
- 05000461/LER-1994-001, :on 940115,unexpected Automatic Isolation of RCIC Sys Occurred During Channel Calibr Surveillance Due to Lifting Wrong Thermocouple Lead.Labels That Are More Visible Installed to Thermocouple Terminal Strips + (ML20063K059)
- ML20063K061 + (ML20063K061)
- ML20063K063 + (ML20063K063)
- 05000440/LER-1994-001, :on 940118,sys Containment Isolation Occurred Due to Reactor Cleanup Sys Valve Nest Room High Differential Temp.Caused by Failure of Inlet Temp Switches.Ab Ventilation Sys Fans Inlet & Temp Switches Replaced + (ML20063K065)
- ML20063K067 + (ML20063K067)
- ML20063K070 + (ML20063K070)
- 05000373/LER-1982-082, Forwards LER 82-082/03L-0 + (ML20063K074)
- 0CAN029404, Forwards Primary & Secondary Financial Protection Endorsements Which Reflect Nuclear Liability Coverage for 1994,as Required by 10CFR140.15 + (ML20063K079)
- 05000373/LER-1982-082-03, /03L-0:on 820731,during Performance of LIS-RH-12, Differential Pressure Switch 1E31-N012A Setpoint Exceeded Allowable Value.Caused by Instrument Setpoint Drift.Trending Underway for Barton Models + (ML20063K081)
- 05000277/LER-1982-019-03, /03L-0:on 820725,main Steam Line Radiation Monitors a & C Revealed hi-hi Trip Setpoints Greater than Tech Spec Limit.Caused by Instrument Zero Drift.Monitors Recalibr + (ML20063K084)
- 05000263/LER-1982-007, Forwards LER 82-007/03L-0 + (ML20063K087)
- 05000263/LER-1982-007-03, /03L-0:on 820726,while Attempting to Add Oil to Governor During Monthly Diesel Generator Test,Personnel Changed Adjustment of Governor Shutdown Solenoid.Caused by Personnel Error.New Governor Installed.Procedure Revised + (ML20063K089)
- ML20063K090 + (ML20063K090)
- ML20063K092 + (ML20063K092)
- ML20063K094 + (ML20063K094)
- 05000315/LER-1982-063, Forwards LER 82-063/03L-0 + (ML20063K095)
- ML20063K097 + (ML20063K097)
- 05000271/LER-1982-017, Forwards LER 82-017/03L-0 + (ML20063K099)
- ML20063K100 + (ML20063K100)
- 05000373/LER-1994-001-02, :on 940117,half Scram & Several Isolations & Half Isolations Occurred Due to Failure of Underfrequency Relay Located Inside MG Set.Rps Bus 1B Energized from Alternate Supply + (ML20063K102)
- 05000315/LER-1982-063-03, /03L-0:on 820730,during Surveillance Test on Diesel Generator Load Shedding Relays,Six GE Model NGV-13b 4-kV Bus Degraded Voltage Relays Exceeded Tech Spec Tolerance.Caused by Instrument Drift.Relays Readjusted + (ML20063K103)
- 05000277/LER-1994-001-01, :on 940119,TS Violation Occurred Due to Fire Detection Sys Breaker Open W/No Hourly Firewatch in DG Cardox Room.Closed Breaker & Restored Fire Detection Instrumentation + (ML20063K105)
- 05000316/LER-1982-067, Forwards LER 82-067/03L-0 + (ML20063K106)
- 05000265/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20063K110)
- ML20063K114 + (ML20063K114)
- 05000316/LER-1982-067-03, /03L-0:on 820801,following Unit Shutdown,Rcs Dose Equivalent I-131 Concentration Exceeded steady-state Limit of Tech Spec 3.4.8.Cause Not Stated.Fuel Burnup by Region & Addl Data Encl + (ML20063K118)
- L-94-007, Forwards Revisions 10 & 11 to Security Plan for Point Beach Units 1 & 2.Withheld Per 10CFR1,50,70 & 73 + (ML20063K121)
- 05000265/LER-1982-016-03, /03L-0:on 820729,RHR Svc Water Pump 2-1001-65B, Removed from Svc to Adjust Inboard & Outboard Booster Pump Seal Packing to Stop Minor Leakage.Caused by Seal Packing Wear Due to Abrasives in River Water.Seal Packing Adjusted + (ML20063K122)
- 05000244/LER-1982-017, Forwards LER 82-017/03L-0 + (ML20063K125)
- ML20063K126 + (ML20063K126)
- 05000271/LER-1982-017-03, /03L-0:on 820726,during Regularly Scheduled Surveillance on Drywell High Pressure Scram Isolation Switches,(Op 4311),P.5.5-12B Found Isolated.Cause Not Stated.Pressure Switch Returned to Svc + (ML20063K128)
- 05000244/LER-1982-017-03, /03L-0:on 820803,during Surveillance Testing of RHR Pump B at 100% steady-state Power,Leakage from Mechanical Seal Exceeded Tech Spec Limit,Rendering Pump Inoperable.Caused by Degradation of Seal Due to Normal Wear + (ML20063K138)
- ML20063K143 + (ML20063K143)
- ML20063K148 + (ML20063K148)
- ML20063K158 + (ML20063K158)
- ML20063K159 + (ML20063K159)
- ML20063K161 + (ML20063K161)
- ML20063K168 + (ML20063K168)
- ML20063K170 + (ML20063K170)
- ML20063K180 + (ML20063K180)
- 05000277/LER-1982-018-31, /03L-0:on 820724,while Testing Smoke Detectors in Cable Spreading Room,One Fire Damper Remained Open When Trip Was Initiated.Caused by Improperly Set Solenoid Release Mechanism (Derby Electric Release).Mechanism Reset & Test + (ML20063K181)
- 05000373/LER-1982-081, Forwards LER 82-081/03L-0 + (ML20063K183)
- ML20063K188 + (ML20063K188)
- 05000373/LER-1982-081-03, /03L-0:on 820802,temp Switch IE31-N602A Setpoint Exceeded Tech Spec Limits.Caused by Setpoint Drift. Instrument Recalibr + (ML20063K191)
- TXX-3561, Followup to 820723 Deficiency Rept Re Exterior Wall of Steam Generator Compartment Wall.Void Located in Unit 1 Not Unit 2 + (ML20063K197)
- ML20063K199 + (ML20063K199)
- ML20063K200 + (ML20063K200)
- 05000368/LER-1982-026, Forwards LER 82-026/03L-0 + (ML20063K201)
- ML20063K205 + (ML20063K205)