Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20063C545 + (ML20063C545)
- 05000368/LER-1982-024, Forwards LER 82-024/03L-0 + (ML20063C549)
- 05000321/LER-1982-063, Forwards LER 82-063/03L-0 + (ML20063C552)
- ML20063C553 + (ML20063C553)
- 05000328/LER-1982-096, Forwards LER 82-096/03L-0 + (ML20063C557)
- ML20063C562 + (ML20063C562)
- ML20063C569 + (ML20063C569)
- 05000338/LER-1982-049, Forwards LER 82-049/03L-0 + (ML20063C570)
- 05000321/LER-1982-063-03, /03L-0:on 820715,inboard Reactor Water Cleanup Primary Containment Isolation Valve Found Open in Presence of Isolation Signal.Caused by Loose Electrical Connection. Loose Connection Tightened + (ML20063C573)
- ML20063C578 + (ML20063C578)
- ML20063C579 + (ML20063C579)
- ML20063C581 + (ML20063C581)
- 05000328/LER-1982-096-03, /03L-0:on 820720,while in Mode 1,safety Injection Pump Failed to Start W/Handswitch in Start Position.Caused by Improperly Locked Locking Ring on Plug Connector in Back of Handswitch.Connector Cleaned & Reinstalled + (ML20063C582)
- 05000368/LER-1982-024-03, Containment High Range Radiation Monitor 2RITS-8925-Z Failed.Caused by Inadequate Tightening of Power Supply Leads in Instrument Cabinet + (ML20063C587)
- ML20063C588 + (ML20063C588)
- L-82-357, Final Deficiency Rept Re Failure of Instrument Inverters. Initially Reported on 820322.Investigation by Solidstate Controls,Inc Found Choke & Inductor Needed Tuning to Inverter Thermal Stress Requirement.Components Redesigned + (ML20063C593)
- ML20063C595 + (ML20063C595)
- 05000338/LER-1982-049-03, /03L-0:on 820723,w/unit Defueled,Defective/Failed Welds Found in Two Thermal Sleeves.Cause Unknown. Westinghouse Investigating Failure.Thermal Sleeves Will Be Removed During Present Outage + (ML20063C596)
- ML20063C601 + (ML20063C601)
- ML20063C614 + (ML20063C614)
- ML20063C624 + (ML20063C624)
- ML20063C628 + (ML20063C628)
- ML20063C629 + (ML20063C629)
- ML20063C634 + (ML20063C634)
- ML20063C635 + (ML20063C635)
- ML20063C641 + (ML20063C641)
- 05000316/LER-1982-062-03, /03L-0:on 820719,carbon Dioxide Isolation Switch for Cd Diesel Generator Room Discovered in Isolate Position W/No Personnel in Area & No Fire Watch Posted.Caused by Personnel Error.Sys Returned to Normal + (ML20063C649)
- ML20063C650 + (ML20063C650)
- ML20063C657 + (ML20063C657)
- ML20063C669 + (ML20063C669)
- ML20063C673 + (ML20063C673)
- ML20063C676 + (ML20063C676)
- ML20063C677 + (ML20063C677)
- ML20063C679 + (ML20063C679)
- ML20063C688 + (ML20063C688)
- ML20063C689 + (ML20063C689)
- ML20063C690 + (ML20063C690)
- 05000339/LER-1982-049, Forwards LER 82-049/03L-0 + (ML20063C691)
- ML20063C692 + (ML20063C692)
- ML20063C695 + (ML20063C695)
- ML20063C699 + (ML20063C699)
- ML20063C700 + (ML20063C700)
- 05000316/LER-1982-063-03, /03L-0:on 820720,starting Time for 2-HV-CEQ-2 Fan Exceeded Tech Spec Tolerance.Caused by Instrument Repeatability Characteristics.Fan Retested Several Times within Allowable Limits + (ML20063C704)
- ML20063C705 + (ML20063C705)
- ML20063C709 + (ML20063C709)
- 05000339/LER-1994-002, :on 940106,discovered That ASME Code Exam Were Not Performed as Required Due to Failure to Follow Procedure.Held Conference Call to Discuss Relief from Code Requirements + (ML20063C710)
- 05000339/LER-1982-049-03, /03L-0:on 820717,RHR Pump a Removed from Svc.On 820730,suction to RHR Pumps a & B Lost.On 820802,RHR Flow Was Less than 3,000 Gpm & Pump Amps Were Fluctuating.Caused by Inadequate RCS Level at RHR Pump Suction Penetration + (ML20063C714)
- ML20063C716 + (ML20063C716)
- ML20063C717 + (ML20063C717)
- ML20063C721 + (ML20063C721)
- ML20063C722 + (ML20063C722)